MAURY USCG vessel records Sign in
← All vessels

QUIST TEUS

QUIST TEUS is a 1981 offshore supply vessel. The Coast Guard has recorded 26 inspections since 1981, most recently in April 2007, along with 29 deficiencies and 1 casualty investigation in 2002.

Records from 1981 to 2007. Most recent: inspection, 28 April 2007.

Built
1981
Last inspected
28 April 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8016304 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HO2357
Flag
PANAMA
—
Maury page id
psix-52627

Inspections, by type

…with no type recorded4
Years with a record 14 calendar years (1981–2007)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it180 - Regulatory (Subpart C or D), Net Ton
242 - Convention (Subpart B), Net Ton
264 - Regulatory (Subpart C or D), Gross Ton
807 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WBP7477MMSI not assigned · cancelled · compulsorily equipped · granted 6 February 1998, cancelled 4 December 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 26

28 April 2007 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 2917538
12 December 2002 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1718095
9 December 2002 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1716679
13 August 2002 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1700928
4 January 2002 Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1475468
30 November 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075821
18 April 2001 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447067
28 August 2000 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 821635
24 August 2000 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054246
27 June 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408554
21 June 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 881070
21 April 1999 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1404755
9 July 1998 Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1372313
3 May 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1375392
8 April 1997 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1368154
21 April 1996 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422673
20 July 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 877483
8 April 1995 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444968
8 November 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1172414
14 June 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025073
15 April 1993 MARPOL Annex II Examination · COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358169
18 March 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 833371
21 July 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1332087
16 June 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1001010
26 July 1985 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 989519
9 July 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969899

Deficiency record · 29

Stability › Watertight Integrity › General
Issued 9 December 2002 Resolved
REPAIR WATER TIGHT HATCH ON PORT SIDE. HATCH HAS SEVERAL HOLES FROM WASTAGE. LEGACY COMPONENT DESC: HATCH
Action required: 705 - Other - as specified
Due 9 January 2003
Resolved 28 April 2007
Stability › Watertight Integrity › General
Issued 9 December 2002 Resolved
MAKE PERMANENT REPAIRS TO AFT WATERTIGHT BULKHEAD IN GALLEY. LEGACY COMPONENT DESC: GALLEY BULKHEAD
Action required: 705 - Other - as specified
Due 9 January 2003
Resolved 28 April 2007
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 9 December 2002 Resolved
REPAIR EMERGENCY LIGHT IN ENGINEROOM PASSAGEWAY.
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 28 April 2007
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 9 December 2002 Resolved
PAINT OT RENEW PORT AFT LIFERING ON MAIN DECK.
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2003
Resolved 28 April 2007
Stability › Watertight Integrity › General
Issued 9 December 2002 Resolved
GOUGE AND REWELD PORT MAIN DECK EXHAUST TRUCK DAMAGED AREA IWO PORT ENGINERROM ESCAPE WATER TIGHT DOOR. LEGACY COMPONENT DESC: PORT AFT EXHAUST TRUNK
Action required: 705 - Other - as specified
Due 9 January 2003
Resolved 28 April 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 9 December 2002 Resolved
INSTALL FLAME SCREEN IN SEWAGE VENT.
Action required: 705 - Other - as specified
Due 9 January 2003
Resolved 28 April 2007
Operations/Management › Drills/Instruction › Fire
Issued 9 December 2002 Resolved
CONDUCT FIRE AND ABANDON SHIPS DRILLS TO SATISFY SIP AUDIT. LEGACY COMPONENT DESC: FIRE & ABANDON SHIP
Action required: 17 - Rectify deficiencies prior to departure
Due 9 January 2003
Resolved 28 April 2007
Construction/Loadline › Hull › Hull Plating
Issued 9 December 2002 Resolved
MAKE PERMANENT REPAIRS TO AFT BULKHEAD IWO PORT AND STARBOARD SHAFT AREAS. CONDUCT UT TESTS ON BOTTOM PLATING UNDER BOTH SHAFTS IN PRESENCE OF A COAST GUARD INSPECTOR. MAKE PERMANENT REPAIRS TO ALL CONCERNED AREAS.
Action required: 705 - Other - as specified
Due 9 January 2003
Resolved 28 April 2007
Stability › Watertight Integrity
Issued 12 December 2001 Resolved
WTD,s are out of adjustment. LEGACY COMPONENT DESC: Watertight doors
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 December 2001
Fire Fighting
Issued 27 June 2000 Resolved
PROVIDE FIRE CONTROL PLAN AS PER 46CFR 91-55.5 (d).
Condition: Unknown
Due 27 June 2000
Resolved 27 June 2000
Documentation
Issued 21 April 1999 Resolved
PROVIDE CURRENT NAUTICAL PUBLICATIONS AND CHARTS._x001C_
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Fire Fighting
Issued 21 April 1999 Resolved
PROVIDE 2 FIREMAN'S OUTFITS IAW 46 CFR 96.35.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Lifesaving
Issued 21 April 1999 Resolved
INSTALL LIFERAFT LAUNCHING ARRANGEMENT FOR BOTH LIFERAFTS PORT & STBD.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Lifesaving
Issued 21 April 1999 Resolved
PROVIDE RESCUE BOAT IAW 46 CFR 133.135, 133.160 & 133.175 OR DISTRICT 8 POLICY LETTER AS AN ALTERNATIVE. PROVIDED COPY TO VESSEL REP.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Lifesaving
Issued 21 April 1999 Resolved
PROVIDE LIFERAFT EMBARKATION LADDERS.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Documentation
Issued 21 April 1999 Resolved
PROVIDE UPDATED FIRE & SAFETY PLAN TO INCLUDE NEW IMO SYMBOLOGY.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Documentation
Issued 9 July 1998 Resolved
PROVIDE DOCUMENTS FOR TWO (2) CERTIFICATED LIFEBOATMEN IAW COI, WITH PROPERSTCW ENDORSEMENTS.
Condition: Unknown
Due 9 July 1998
Resolved 9 July 1998
Deck/Cargo
Issued 9 July 1998 Resolved
PROVIDE PROPER RELIEF VALVES FOR P-TANKS, M.A.W.P. IS 40 PSI.
Condition: Unknown
Due 9 July 1998
Resolved 9 July 1998
Construction/Loadline
Issued 8 April 1995 Resolved
CONDUCT ULTRASONIC TESTING TO AREA AROUND HOLE IN INBOARD BULKHEAD (COMMON TO AFT TUNNEL) OF #4 STBD BALLAST TANK. CROP WASTED AREA BACK TO GOOD METALAND INSERT WITH APRROPRIATE SIZED PLATE (18" X 18" MINIMUM). MAKE UT READINGS AND REPAIR AVAILABLE TO ATTENDING USCG INSPECTOR OR ABS SURVEYOR.
Condition: Unknown
Due 23 April 1995
Resolved 27 April 1995
Deck/Cargo
Issued 8 April 1995 Resolved
MAKE DRY BULK CARGO TANKS (PRESSURE TANKS) AVAILABLE FOR INTERNAL EXAMINATION AT NEXT SCHEDULED DRYDOCKING.
Condition: Unknown
Due 8 April 1995
Resolved 8 April 1995
Construction/Loadline
Issued 8 April 1995 Resolved
REATTACH INTERNAL FRAMING WHERE SEPARATED IN PORT AND STARBOARD #4 BALLAST TANKS. MAKE REPAIRS AVAILABLE FOR EXAMINATION BY ABS SURVEYOR OR USCG MARINE INSPECTOR.
Condition: Unknown
Due 23 April 1995
Resolved 27 April 1995
Deck/Cargo
Issued 8 April 1995 Resolved
REPLACE OR RESET AND SEAL TWO INAPPROPRIATE P-TANK RELIEF VALVES WITH 42PSIG SET RELIEF VALVES WITH AT LEAST DESIGN CFM CAPACITY. PROVIDE LETTEROF SATISFACTORY COMPLETION TO [name withheld] TO BE REPLACED OR RESET PRIOR TO PRESSURIZING TANKS.
Condition: Unknown
Due 8 May 1995
Resolved 27 April 1995
Construction/Loadline
Issued 8 April 1995 Resolved
REMOVE DOUBLER PLATE FROM INBOARD BULKHEAD OF #4 STBD BALLAST TANK. CROP DAMAGED AREA TO GOOD METAL AND INSERT AS APPROPRIATE. MAKE REPAIR AVAILABLE FOR EXAMINATION BY ABS SURVEYOR OR USCG INSPECTOR.
Condition: Unknown
Due 23 April 1995
Resolved 27 April 1995
Construction/Loadline
Issued 8 April 1995 Resolved
CONDUCT ULTRASONIC TESTING TO HOLED AREA IN STBD SIDE BULKHEAD IN STEERING SPACE (COMMON TO AFT PEAK OR #5 STBD BALLAST TANK). CROP WASTED AREA BACK TO GOOD METAL AND INSERT AS APPROPRIATE. MAKE UT READINGS AND REPAIRS AVAILABLE FOR EXAMINATION BY ATTENDING USCG INSPECTOR OR ABS SURVEYOR.
Condition: Unknown
Due 23 April 1995
Resolved 27 April 1995
Construction/Loadline
Issued 8 April 1995 Resolved
REATTACH OR SCRIBE IN NEW PLATE TO SECURE PARTED SWASH BULKHEAD TO INBOARD BULKHEAD IN #4 STBD BALLAST TANK. AFFECTED SWASH BULKHEAD IS IN LINE WITH TORN AREA UNDER DOUBLER ON BULKHEAD (ITEM #3). MAKE REPAIRS AVAILABLE FOR EXAMINATION BY ABS SURVEYOR OR USCG INSPECTOR.
Condition: Unknown
Due 23 April 1995
Resolved 27 April 1995
Navigation
Issued 14 June 1994 Resolved
REPAIR RELAY IN NAVIGATION LIGHT PANEL FOR ANCHOR LIGHT.
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Engineering
Issued 14 June 1994 Resolved
REPAIR OR REPLACE INOPERATIVE SHAFT TACHOMETERS FOR PORT & STBD MAIN ENGINES ON BRIDGE.
Condition: Unknown
Due 14 June 1994
Resolved 14 June 1994
Fire Fighting
Issued 26 July 1985 Resolved
TO REMOVE THE OILER REQUIREMENT FROM THE CERTIFICATE OF INSPECTION, THE FIRE MAIN PRESSURE GAGE MUST BE MADE OPERABLE AT THE BRIDGE.
Condition: Unknown
Due 26 July 1985
Resolved 26 July 1985
Lifesaving
Issued 26 July 1985 Resolved
PROVIDE A LINE THROWING GUN AND ITS EQUIPMENT.
Condition: Unknown
Due 26 July 1985
Resolved 26 July 1985

Casualty record · 1

13 August 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1700928
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

QUIST TIDE (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record