MAURY USCG vessel records
← All vessels

USL 499

USL 499 is a 1977 tank barge. The Coast Guard has recorded 39 inspections since 1981, most recently in April 2002, along with 7 deficiencies.

Records from 1981 to 2002. Most recent: inspection, 18 April 2002.

Built
1977
Last inspected
18 April 2002
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 18 April 2002
…with no type recorded14
Operational controls None recorded without a removal date
Years with a record 22 calendar years (1981–2002)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-52630

Documentation record

Tonnage as PSIX records it1384 - Regulatory (Subpart C or D), Gross Ton
1384 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 39

18 April 2002 Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1606472
23 April 2001 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1065826
1 September 2000 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 822816
12 May 2000 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 818443
27 May 1999 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1406498
11 May 1998 COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1128908
8 May 1997 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1101271
8 April 1997 Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1104418
11 March 1997 Hull Examination · COI Inspection · Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1101751
11 October 1996 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1374761
15 November 1995 COI Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1188527
30 November 1994 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1398166
23 March 1994 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1166110
23 March 1994 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1167755
28 February 1994 Deficiency Check
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 853756
30 November 1993 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1414216
24 August 1993 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 494311
16 February 1993 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1436722
28 October 1992 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 533417
2 March 1992 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 506811
10 January 1992 Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 954762
4 December 1991 Re-Inspection
Physical examination · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 1264523
11 July 1991 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 441206
12 October 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1228057
17 September 1990 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 453700
13 February 1990 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1228629
4 December 1989 Type not recorded
No type recorded · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 495876
24 April 1989 Examination of Repairs
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1198092
16 December 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347624
1 March 1988 Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1336896
1 July 1987 Type not recorded
No type recorded · MSO HUNTINGTON · USCG Heartland District (CGD-H) · Activity 456754
5 January 1987 Hull Examination · COI Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1311435
3 February 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 988215
13 February 1985 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1282331
3 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971532
29 November 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278917
6 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965283
19 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271762
2 July 1981 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 968631

Deficiency record · 7

Deck/Cargo
Issued 8 May 1997 Resolved
PROCEED TO ALSPIN, IL, TO OFFLOAD CARGO. PRIOR TO NEXT CARGO OPERATION PROCEED TO HOUSTON, TX, GAS FREE AND MAKE PERMANENT REPAIRS TO #3 PORT CARGO TANK AFT BULKHEAD LEAK TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 May 1997
Resolved 8 May 1997
Deck/Cargo
Issued 8 April 1997 Resolved
PROCEED TO ALSPIN, IL TO OFFLOAD CARGO. PRIOR TO NEXT CARGO OPERTION PROCEED TO HOUSTON, TX, GAS FREE AND MAKE PERMANENT REPAIRS TO #3 PORT CARGO TANK AFT BULKHEAD LEAK TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 April 1997
Resolved 8 April 1997
Documentation
Issued 11 October 1996 Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION AS REQUIRED BY 46 CFR 67.7.
Condition: Unknown
Due 11 October 1996
Resolved 11 October 1996
Construction/Loadline
Issued 28 February 1994 Resolved
PRIOR TO RELOADING CARGO, DEWATER AND DETERMINE SOURCE OF WATER LEAKAGE INTO THE STERN BOX VOID. PERMANENT REPAIR IS TO BE EFFECTED TO THE AREA INWAY OF THE LEAK.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Deck/Cargo
Issued 4 December 1991 Resolved
PRIOR TO LOADING CARGO, PROVIDE PROOF OF ANNUAL HYDROSTATIC TEST OF CARGO PIPING.
Condition: Unknown
Due 4 December 1991
Resolved 4 December 1991
Unknown
Issued 6 October 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL USL 499, DN583135.
Condition: Unknown
Due 6 October 1983
Resolved 6 October 1983
Deck/Cargo
Issued 6 October 1983 Resolved
HYDROSTATICALLY TEST CARGO PIPING TO AT LEAST 1.5 TIMES MAWP PROVIDE EVIDENCE OF SATISFACTORY TEST TO [name withheld], LA
Condition: Unknown
Due 6 October 1983
Resolved 6 October 1983

Ownership record