Records from 2016 to 2026. Most recent: inspection, 20 April 2026.
Documentation record
Registered dimensions (L × B × D)41.2 ft × 14.4 ft × 6.1 ft
Registered tonnagegross 27 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERMONS BOAT YARD · TARPON SPRINGS FL, UNITED STATES · built 1979
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton
21 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 19
20 April 2026
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8349534
9 April 2026
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8345129
15 April 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8112191
1 May 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7904152
28 March 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7886221
16 July 2023
Type not recorded
No type recorded · Station Kings Point · USCG Northeast District (CGD-NE) · Activity 7744080
14 April 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7668025
13 April 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7430053
4 April 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7424242
30 April 2021
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7183330
18 June 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6965613
27 April 2020
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6989736
13 May 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6682817
11 October 2018
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6559521
26 April 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6436240
18 April 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6394339
9 May 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6142360
2 May 2016
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5867579
26 April 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5862652
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 20 April 2026
Resolved
"To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date." MI observed FCC Radio Station call sign and EPIRB call sign not the same. Update EPIRB call sign to reflect correct information within 14 days.
47 CFR 80.1061(f)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 29 April 2026
Resolution: EPIRB Call sign now registered with correct call sign.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 20 April 2026
Resolved
"As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible; U.S. Coast Pilot or similar publication; Coast Guard Light List..." MI observed charts, light list, and coast pilot to not be up-to-date. Replace with up-to-date copies within 30 days.
46 CFR 184.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2026
Resolved 28 April 2026
Resolution: All publication and charts up-to-date.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2026
Resolved
"Placards containing instructions for the donning and use of the life jackets aboard the vessel must be posted in conspicuous places that are regularly accessible and visible to the crew and passengers." MI observed no life jacket donning placard posted. Rectify within 30 days.
46 CFR 185.516
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2026
Resolved 28 April 2026
Resolution: Placard installed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 9 April 2026
Resolved
MI's observed crack on the port quarter suggesting delamination. Sand down to good FRP and Reglass.
Action required: 705 - Other - as specified
Resolved 14 April 2026
Resolution: Vsl master reported with photos of rectified def.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 1 May 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1)Charts...Vessel did not have the appropriate charts up-to-date at inspeciton.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2024
Resolved 8 May 2024
Resolution: Recieved evidence of new chart purchase
Lifesaving › Lifefloat › Netting
Issued 26 April 2018
Resolved
Repair life float basket on both life Floats, the vessel will be restricted to LBS route until complete.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 11 October 2018
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 3 May 2016
Resolved
Conduct DAPI Audit
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 June 2016
Resolved 3 June 2016
Resolution: DAPI audit conducted
Operations/Management › Pollution › Control of Discharge of Sewage
Issued 3 May 2016
Resolved
Secure sewage OVBD valve IAW 33 CFR 159
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 May 2016
Resolved 13 May 2016
Resolution: Operator removed sewage ovbd discharge valve handle.
Electrical › Lighting (service) › Lighting Fixture
Issued 3 May 2016
Resolved
Install light covers for light fixtures in pilot house and head.
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 13 May 2016
Resolution: Operator replaced light fixtures with proper fixtures.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 May 2016
Resolved
All electical connection smust be made in a junction box. Make all connections in junction box.
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 3 June 2016
Resolution: Vessel has a plan in place to repair electrical system by next inspection.
Lifesaving › Lifefloat › Paddle
Issued 3 May 2016
Resolved
Paddles on LF must be tethered to LF
Action required: 705 - Other - as specified
Due 6 May 2016
Resolved 13 May 2016
Resolution: Paddles lashed to life float.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 3 May 2016
Resolved
Install proper cable for batteries. Remove all welding cable.
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 15 May 2016
Resolution: Operator installed proper marine grade battery cable.
Fire Fighting › Remote Fuel Shutoff › General
Issued 3 May 2016
Resolved
F/O shutoff valve must be accesibl w/o providing air to fire
Action required: 705 - Other - as specified
Due 15 May 2016
Resolved 15 May 2016
Resolution: Operator installed 6 inch access ports in bench seat to allow closure of fuel valves.
Electrical › Electric Supply System (service) › Battery Charger
Issued 3 May 2016
Resolved
Make proper connections for batttery charger.
Action required: 705 - Other - as specified
Due 15 May 2016
Resolved 4 June 2016
Resolution: Connections made with pressure type connectors.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 3 May 2016
Resolved
Update emergency instructions to reflect appropriate actions.
Action required: 705 - Other - as specified
Due 15 May 2016
Resolved 15 May 2016
Resolution: Removed "jump overboard" portion of man overboard drill in emergency instructions.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 May 2016
Resolved
All electrical equipment in metal housing must be bonded together and connected to a common grounding plate.
Action required: 705 - Other - as specified
Due 1 June 2016
Resolved 3 June 2016
Resolution: External light fixtures grounded properly.
Navigation › Piloting/Steering › Marine Charts
Issued 2 May 2016
Resolved
Onboard charts, pubs and coast pilot out of date. Provide up-to-date nautical pubs and charts.
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2016
Resolved 13 May 2016
Resolution: Operator provided proof of new charts and coast pilot.