Records from 1982 to 1984. Most recent: inspection, 31 December 1984.
Documentation record
Registered dimensions (L × B × D)180.1 ft
Registered tonnagegross 764 / net 764
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilt 1957
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsNot recorded
DocumentationInvalid
Service, as the file records itMobile Offshore Drilling Unit
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it764 - Regulatory (Subpart C or D), Net Ton
764 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 8
31 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977764
21 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280442
22 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973395
29 December 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280099
15 March 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1279910
11 January 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277753
27 August 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277439
21 May 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272512
Unknown
Issued 29 December 1983
Resolved
THE FOLLOWING DEFICIENCY IS FOR THE ODECO SEVEN, DN274965.
Condition: Unknown
Due 29 December 1983
Resolved 29 December 1983
Lifesaving
Issued 21 May 1982
Resolved
PROPERLY ATTACH WEAK LINKS FOR BOTH LIFERAFTS. (46 CFR 108.505)
Condition: Unknown
Due 21 May 1982
Resolved 21 May 1982
Lifesaving
Issued 21 May 1982
Resolved
PROVIDE WATERTIGHT BRACKETS AND PAINTERS OF LINE (1/2 DIAMETER BY 3 X DISTANCE FROM RAFT TO WATER FOR ALL LIFERAFTS. (33 CFR 144)
Condition: Unknown
Due 21 May 1982
Resolved 21 May 1982
Lifesaving
Issued 21 May 1982
Resolved
PROVIDE FIVE (5) CARTRIDGES, ONE (1) PROJECTILE, ONE (1) SERVICE LINE AND ONE (1) AUXILIARY LINE FOR LINE THROWING GUN. (46 CFR 108.517)
Condition: Unknown
Due 21 May 1982
Resolved 21 May 1982
Navigation
Issued 21 May 1982
Resolved
PROVIDE NOT UNDER-COMMAND NAVIGATING LIGHTS (RED OVER RED WITH SERPERATION OF AT LEAST ONE (1) METER)
Condition: Unknown
Due 21 May 1982
Resolved 21 May 1982
Accommodation/Occupational Safety
Issued 21 May 1982
Resolved
REPAIR WASTED RAILS ON PORT AFT SIDE. (NVC 478 3D (1)(A))
Condition: Unknown
Due 21 May 1982
Resolved 21 May 1982
Unknown
Issued 21 May 1982
Resolved
PROVIDE GAS FREE CONNECTION FOR EQUIPMENT ON DRILL FLOOR.
Condition: Unknown
Due 21 May 1982
Resolved 21 May 1982
Unknown
Issued 21 May 1982
Resolved
PROVIDE FOLLOWING EQUIP. SUITABLE FOR CLASS. LOCATION IN THE SHALE SHAKER AREA: PA BOX & CONNECTIONS; JUNCTION BOX NEAR PHONE; PHONE & CONNECTIONS.
Condition: Unknown
Due 21 May 1982
Resolved 21 May 1982
Electrical
Issued 21 May 1982
Resolved
IN THE MUD PIT AREA PROVIDE EXPLOSION PROOF FITTING FOR LIGHTS ON FORWARD AND PORT SIDE BULKHEADS.
Condition: Unknown
Due 21 May 1982
Resolved 21 May 1982
Engineering
Issued 21 May 1982
Resolved
PROVIDE CONTAINMENT FOR MAIN FUEL OIL TANK VENTS.
Condition: Unknown
Due 21 May 1982
Resolved 21 May 1982
Deck/Cargo
Issued 21 May 1982
Resolved
PROVIDE CURRENT FMC CERTIFICATE FOR POLLUTION FINANCIAL RESPONSIBILITY (46 CFR 542.6).
Condition: Unknown
Due 21 May 1982
Resolved 21 May 1982
Electrical
Issued 21 May 1982
Resolved
SUBMIT HAZARDOUS LOCATIONS PLAN FOR APPROVAL AND PROVIDE APPROVED COPY TO RIG (NVC 4-73 3D(2)(A)).
Condition: Unknown
Due 21 May 1982
Resolved 21 May 1982
Lifesaving
Issued 21 May 1982
Resolved
SERVICE HYDROSTATIC RELEASE FOR THE LIFERAFT NO.2 AND TIGHTEN STRAP FOR PROPER RELEASE OPERATION. (46 CFR 108.505)
Condition: Unknown
Due 21 May 1982
Resolved 21 May 1982