Records from 1985 to 2025. Most recent: inspection, 21 November 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 65
21 November 2025
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8272062
18 September 2025
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8236353
19 February 2025
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8081983
15 October 2024
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8019128
11 September 2024
Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8000497
23 August 2023
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7774288
10 August 2022
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7536987
28 June 2022
COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7470898
2 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7442327
19 April 2021
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7179610
14 October 2020
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7077046
29 June 2020
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6991161
25 March 2020
Administrative Inspection · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6928462
26 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6839838
1 June 2018
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6433594
20 April 2018
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6395860
7 April 2017
DAPI Audit · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6119864
29 April 2016
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5867635
19 June 2014
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4892439
1 May 2014
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4850703
21 June 2012
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4351435
22 July 2011
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4090752
3 March 2010
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3688444
23 April 2009
Annual Inspection · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3459196
22 September 2008
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3330045
22 May 2008
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3189795
14 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2929902
16 April 2007
COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2906058
26 July 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2725243
18 May 2006
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2652517
12 May 2006
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2647338
28 April 2005
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2344723
28 March 2005
Periodic Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2323707
21 March 2005
Hull Examination · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2315442
15 April 2004
Re-Inspection · Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2042320
30 March 2004
Type not recorded
No type recorded · Coast Guard Station Chicago · USCG Great Lakes District (CGD-GL) · Activity 2036606
10 March 2004
Administrative Inspection
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2021253
24 April 2003
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1778215
22 April 2002
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1600483
5 April 2001
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1471245
12 April 2000
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1047579
8 April 1999
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1429112
13 January 1999
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1123002
7 January 1999
Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1399019
3 April 1998
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1414982
10 April 1997
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1364216
28 June 1996
Deficiency Check
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1090622
4 June 1996
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 90997
25 April 1996
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1363598
26 October 1995
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1367712
11 May 1995
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1355325
29 March 1995
Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1403941
9 May 1994
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1423939
28 April 1993
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1145073
30 April 1992
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 956866
26 April 1991
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1217730
29 March 1991
Hull Examination
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1219323
3 May 1990
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1217835
29 June 1989
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1037707
3 May 1988
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1201296
4 May 1987
COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1021071
7 May 1986
Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1297125
11 April 1986
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1306791
17 March 1986
Credit Drydock
Administrative · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 994968
6 May 1985
Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 974045
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 September 2025
No resolution recorded
A pre-engineered fixed gas extinguishing system must shut down all engines that draw intake air from the space. The installed system does not shut down the main engines. Make repairs to the same.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 18 September 2025
No resolution recorded
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 September 2025
Resolved
The painter in way of the port lifefloat waterlight must be 18 feet in length and secured around the body of the lifefloat. Verify the length of the painter and properly secure the same around the body of the lifefloat.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2025
Resolved 25 November 2025
Resolution: Witnessed satisfactory replacement of the waterlight lanyard.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 September 2025
No resolution recorded
The owner must make the vessel available for all drills. There was insufficient crew on board during inspection to conduct drills. Conduct man-overboard, fire fighting, and man-overboard drills in the presence of a Marine Insepector prior to carrying passengers for hire.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 September 2025
Resolved
A vessel must carry at least one waterlight. The ring buoy floating waterlight is extinguished. Prove proper operation of the same.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2025
Resolution: Witnessed satisfactory operation of the floating waterlight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 September 2025
Resolved
Electrical equipment must be installed to protect passengers and crew. Remove dead end wiring in engine compartment and aft void as indicated by Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 October 2025
Resolved 21 November 2025
Resolution: Witnessed satisfactory removal of the dead end wiring in the engine compartment.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 11 September 2024
Resolved
Vessel must have onboard a First Aid kit with approved contents, renew all expired contents.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 15 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 September 2024
Resolved
Vessels name must be on all ring life buoys Min. 2 inch lettering.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 19 September 2024
Resolution: name was corrected.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 September 2024
Resolved
Battery charges must be equipped with amp meters. Install Amp meters on both chargers.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 15 October 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 September 2024
Resolved
B-I extinguisher at the upper operation station was discharged and not mounted. Replace and provide approved bracket.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 September 2024
Resolved 11 September 2024
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 September 2024
Resolved
vessel must have operable gauges to indicate engine temp and oil pressure at the helm. prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2024
Resolved 15 October 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 August 2023
Resolved
Properly Label upper deck Ring Buoy.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 August 2023
Resolution: Owner Labeled buoy.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 23 August 2023
Resolved
Operator could not recall how to use Radar. Prove proper operation of the Radar.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 August 2023
Resolved 24 August 2023
Resolution: Operator reviewed proceedures to operate Radar.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 23 August 2023
Resolved
Forward Anchor light was inop. Prove proper operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 August 2023
Resolution: Lamp was replaced.
01 - Certificates & Documentation › 012 - Crew Certificates › Training and qualification MLC - Personnel safety training
Issued 23 August 2023
Resolved
Conduct drills and get vessel underway with fully trained crew that are enrolled in company DAPI program.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 August 2023
Resolved 24 August 2023
Resolution: Crew that was in DAPI provided and drills where conducted.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 23 August 2023
Resolved
Properly label paddles for portside BA with vessels name.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2023
Resolved 24 August 2023
Resolution: Paddles where labeled with vessels name.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 2 May 2022
Resolved
Vessel's COI expired in April. The vessel is prohibited from carrying passengers for hire until the Certificate is renewed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 June 2022
Resolution: Vessel completed COI.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 April 2021
Resolved
Replace or repair ring bouy light. Vessel is restricted to day time operating hours.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 April 2021
Resolved 20 April 2021
Resolution: Owner purchased new waterlight, sent photo of purchase.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 29 June 2020
Resolved
Last record of drills was July 3, 2019 for a fire drill. Provide method of documentation and conduct MOB, Fire and adandon ship drills with crew, prior to operation for season then as prescribed by regulation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 July 2020
Resolved 14 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 29 June 2020
Resolved
Vessel has no record of monthly testing of EPIRB. Provide record of testing as required by regulation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 14 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 29 June 2020
Resolved
Vessel has no record of inspecting primary lifesaving equipment(Bouyant App). Provide record of Weekly, Monthly, Quarterly and Annual inspections as required by regulation.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 July 2020
Resolved 14 October 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 26 April 2019
Resolved
Marine Operator Permit missing
Action required: 705 - Other - as specified
Resolved 26 April 2019
Resolution: Sent in proof of vaild marine operator permit
Communications › Radio Communications › EPIRB
Issued 20 April 2018
Resolved
update Battery
Action required: 705 - Other - as specified
Due 27 April 2018
Resolved 1 June 2018
Resolution: Replace battery
Operations/Management › Drills/Instruction › Fire
Issued 20 April 2018
Resolved
Provide Log that details required FF/MOB training
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2018
Resolved 1 June 2018
Resolution: Logs and Records available for review
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 April 2018
Resolved
Provide approved first aid kit
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2018
Resolved 1 June 2018
Resolution: First Aid kit up to date.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 May 2008
Resolved
Found S/W Exhaust cooling hose w/ signs of dry rot and a towel to buffer against rubbing. Re-new S/W Exhaut cooling hose on generator in accordance with 46 CFR 182.720.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2008
Resolved 22 September 2008
Resolution: Received photos via email from [name withheld] showing the replacement of (02) R/W hoses on generator. Hoses were double clamped and meet requirements. Photos scanned into documentation.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 April 2007
Resolved
Install metal supports on electrical wiring in engineroom IAW 46 CFR 183.340
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 14 May 2007
Resolution: Received photos showing new installation of wire clamps in E/R.
Engineering › Freshwater System (cylinder head cooling) › Hose
Issued 16 April 2007
Resolved
Install double hose clamps on port engine R/W system IAW 182.420
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2007
Resolved 14 May 2007
Resolution: Received photos showing new installation of hose clamps in E/R.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 12 May 2006
Resolved
Prove proper operation of fix fire extinguisher system.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 May 2006
Navigation › Collision/Grounding Avoidance › Radar
Issued 12 May 2006
Resolved
Prove proper operation of Radar or remove from vessel.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 26 July 2006
Resolution: Observed operation of installed radar.
Personnel › Training › First Aid/CPR
Issued 12 May 2006
Resolved
Ensure 50% of deckhands have proper first aid/lifesaving training.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 26 July 2006
Resolution: Was provided with proper documentation of first aid/lifesaving training.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 May 2006
Resolved
Provide CG approved first aid kit.
Action required: 705 - Other - as specified
Due 12 June 2006
Resolved 16 May 2006
Construction/Loadline › Structures › Door
Issued 28 April 2005
Resolved
Ensure vessel meets minimum height requirements for watertight coamings on a partially protected route.
46 CFR 171.124
Action required: 705 - Other - as specified
Due 27 May 2005
Resolved 31 May 2005
Resolution: [name withheld] installed a 6" coaming, all sat. Conducted watertight test on fwd hatch on deck, all sat.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 28 March 2005
Resolved
Replace or renew contents in first aid kit.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 27 April 2005
Resolution: Updated first aid kit.
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 28 March 2005
Resolved
remove or provide excisting waste receptacles with proper construction or provide metal inserts.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 27 April 2005
Resolution: purchased all metal trash cans
Engineering › Diesel Engine (auxiliary) › Block
Issued 28 March 2005
Resolved
Remove absorbent rags/towels from under engines or provide proof of fire rating.
Action required: 705 - Other - as specified
Due 23 May 2005
Resolved 27 April 2005
Resolution: Removed rags/towels from under engines
Engineering › Bilge Water Management System
Issued 15 April 2004
Resolved
Prove proper operation of bilge high level alarm for engineroom, and install alarms and lights at the flying bridge per 46 CFR 182.530. LEGACY COMPONENT DESC: Interface Detector
Condition: Placed in Improper Service
Due 15 May 2004
Resolved 4 May 2004
Resolution: all bilge alarms operational [name withheld]
Electrical › Electric Supply System (service)
Issued 15 April 2004
Resolved
Install battery covers or boots per 46 CFR 183.354. LEGACY COMPONENT DESC: Battery Conductor
Condition: Placed in Improper Service
Due 15 May 2004
Resolved 22 April 2004
Documentation › Safety/Response Plans/Programs
Issued 15 April 2004
Resolved
Revise emergency proceedures in include use of the lifering per 46 CFR 185.512.
Due 15 May 2004
Resolved 22 April 2004
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 15 April 2004
Resolved
Provide double clamps on all raw water lines at the L/O coolers.
Condition: Placed in Improper Service
Due 15 May 2004
Resolved 22 April 2004
Lifesaving
Issued 15 April 2004
Resolved
Provide proof that The First Aid kit is in Complaince with 46 CFR 160.041.
Condition: Placed in Improper Service
Due 15 May 2004
Resolved 22 April 2004
Lifesaving › Lifebuoys
Issued 15 April 2004
Resolved
Relocate Ring Bouy to main deck, or provide 2nd Bouy to comply with 46 CFR 180.70 LEGACY COMPONENT DESC: Stowage
Condition: Placed in Improper Service
Due 15 May 2004
Resolved 22 April 2004
Lifesaving › Lifebuoys
Issued 15 April 2004
Resolved
Renew Ring Bouy line with 60' of 5/16" diameter floating line. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 April 2004
Resolved 22 April 2004
Documentation › Safety/Response Plans/Programs
Issued 15 April 2004
Resolved
Conduct Man Overboard and Fire Drills to the satisfaction of the Attending Marine inspector.
Due 22 April 2004
Resolved 22 April 2004
Engineering › Diesel Engine (propulsion-direct drive)
Issued 22 April 2002
Resolved
REPAIR STARBOARD ENGINE SHUTDOWN.
Due 22 May 2002
Resolved 25 April 2002
Resolution: [name withheld] SHUTDOWN.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 22 April 2002
Resolved
PROVIDE SERVICING RECEIPT FOR FIXED FIRE FIGHTING SYSTEM.
Due 22 May 2002
Resolved 25 April 2002
Resolution: OWNER FAXED FIXED FIRE FIGHTING SYSTEM SERVICING RECEIPT TO MSO CHICAGO.
Lifesaving › Lifejacket/PFD (Type I)
Issued 22 April 2002
Resolved
PROVIDE TOTAL OF 20 TYPE I PFD'S PER COI. LIMITED TO CARRIAGE OF 12 PASSENGERS UNTIL CORRECTED.
Due 22 May 2002
Resolved 25 April 2002
Resolution: [name withheld] OF 20 LIFE JACKETS ON BOARD.
Lifesaving
Issued 22 April 2002
Resolved
REPLACE HYDROSTATIC RELEASE ON EPIRB PRIOR TO OPERATING BEYOND 3 MILES FROM SHORE.
Due 22 May 2002
Resolved 25 April 2002
Resolution: [name withheld] OF NEW HYDROSTATIC RELEASE.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 April 2002
Resolved
PROVIDE UPDATED MAN OVERBOARD PROCEDURES AND CONDUCT SATISFACTORY MAN OVERBOARD DRILL IN THE PRESENCE OF A MARINE INSPECTOR.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2002
Resolved 25 April 2002
Resolution: [name withheld] MAN OVERBOARD DRILL AND REVIEWED UPDATED EMERGENCY PROCEDURES.
Engineering › Bilge Water Management System › Manifold
Issued 22 April 2002
Resolved
LABEL VALVES ON BILGE MANIFOLD
Due 22 May 2002
Resolved 25 April 2002
Resolution: [name withheld] BILGE VALVE LABELS.
Documentation › Markings/Placards › Garbage Placard
Issued 22 April 2002
Resolved
POST MARPOL GARBAGE PLACARD.
Due 22 May 2002
Resolved 25 April 2002
Resolution: [name withheld] POSING OF MARPOL PLACARD.
Navigation
Issued 8 April 1999
Resolved
PROVIDE CURRENT AND UPDATED CHARTS AND REQUIRED PUBLICATIONS TO THE SATIS- FACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 May 1999
Resolved 16 April 1999
Lifesaving
Issued 8 April 1999
Resolved
PRIOR TO CARRYING PASSENGERS ON BOARD, REPLACE ALL RETRO REFLECTIVE TAPE ONALL LIFE RINGS AND LIFE FLOAT TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 May 1999
Resolved 16 April 1999
Lifesaving
Issued 8 April 1999
Resolved
PRIOR TO CARRYING PASSENGERS ON BOARD, REPLACE ALL LIFE LINES ON ALL LIFE RINGS AND LIFE FLOAT WITH APPROVED TYPE AND LENGTH TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 May 1999
Resolved 16 April 1999
Lifesaving
Issued 8 April 1999
Resolved
PRIOR TO CARRYING PASSENGERS ON BOARD, RERPLACE WATERLIGHT LANYARD ON LIFE FLOAT WITH AN APPROVED TYPE AND SIZE OF AT LEAST EIGHTEEN (18) FEET TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 May 1999
Resolved 16 April 1999
Construction/Loadline
Issued 8 April 1999
Resolved
PROVE PROPER OPERATION OF ALL BILGE ALARMS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 10 May 1999
Resolved 16 April 1999
Lifesaving
Issued 3 April 1998
Resolved
Provide and post a lifejacket donning placard.
Condition: Unknown
Due 3 April 1998
Resolved 3 April 1998
Documentation
Issued 25 April 1996
Resolved
Provide current Certificate of Documentation.
Condition: Unknown
Due 25 April 1996
Resolved 25 April 1996
Documentation
Issued 11 May 1995
Resolved
Provide most recent Stability Test documentation for OCMI to obtain Stability Letter.
Condition: Unknown
Due 27 June 1995
Resolved 5 July 1995
Lifesaving
Issued 11 May 1995
Resolved
Complete satisfactory emergency drills including, but not limited to: man overboard, fire and abandon ship.
Condition: Unknown
Due 5 July 1995
Resolved 5 July 1995