TAYLORS FALLS QUEEN

TAYLORS FALLS QUEEN is a 1981 passenger vessel (inspected). The Coast Guard has recorded 61 inspections since 1985, most recently in April 2026, along with 46 deficiencies and 1 casualty investigation in 2016.

Records from 1985 to 2026. Most recent: inspection, 29 April 2026.

Built
1981
Last inspected
29 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WUX8227
Flag
UNITED STATES
367664020
Maury page id
psix-52684

Inspections, by type

…with no type recorded5
Years with a record 38 calendar years (1985–2026)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)65.0 ft × 18.5 ft × 3.2 ft
Registered tonnagegross 46 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTED MANNSTEDT & SONS INC · LA CROSSE, WI, UNITED STATES · built 1981
Hull materialSteel
PropulsionCombination Types
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portTAYLORS FALL, MN
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Gross Ton
30 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ3206MMSI 367664020 · active · compulsorily equipped · granted 19 April 2025, expires 19 April 2035
WDH9032MMSI 367664020 · expired · compulsorily equipped · granted 28 March 2015, cancelled 14 April 2025
WUX8227MMSI not assigned · expired · compulsorily equipped · granted 27 March 1998, cancelled 19 July 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 61

29 April 2026 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8357463
24 March 2026 Administrative Inspection
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8331023
22 April 2025 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 8090999
30 April 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7903499
11 May 2023 In-Service Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7683540
26 April 2022 COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7417794
19 October 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7335572
12 October 2021 Administrative Inspection
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7330851
29 April 2021 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7188056
26 February 2021 Administrative Inspection
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 7146800
4 May 2020 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6947847
25 April 2019 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6670976
26 April 2018 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6399974
27 April 2017 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6104393
18 October 2016 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 6025704
21 July 2016 Damage Survey
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5948447
21 July 2016 Type not recorded
No type recorded · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5952277
20 April 2016 Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5860065
11 February 2016 Administrative Inspection
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 5813830
1 May 2012 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4299264
7 September 2011 Simplified Stability Test
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 4138153
28 April 2009 MTSA Verification · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3433013
20 October 2008 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3349038
24 April 2008 Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3191523
17 April 2008 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3184781
4 May 2007 Deficiency Check
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2963017
25 April 2007 COI Inspection
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 2914403
2 May 2006 Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2640447
27 April 2005 Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2383799
11 June 2004 Deficiency Check · Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 2095225
13 November 2003 Internal Structural Exam · Hull Examination
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1948973
30 April 2003 Annual Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1787088
1 May 2002 COI Inspection
Physical examination · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 1653619
2 May 2001 Re-Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1441863
3 May 2000 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1472364
2 May 1999 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1437535
12 November 1998 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1390867
28 April 1998 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1378364
2 May 1997 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1452284
2 May 1996 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1462497
2 May 1995 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1450972
10 June 1994 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1173075
2 May 1994 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 858278
14 October 1993 Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1154890
3 October 1993 Damage Survey
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 846859
2 October 1993 Type not recorded
No type recorded · MSD ST. PAUL · USCG Heartland District (CGD-H) · Activity 104010
4 May 1993 COI Inspection · Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1150731
4 May 1992 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 934468
18 September 1991 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 938641
22 April 1991 Hull Examination · Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 922814
10 July 1990 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1243325
14 May 1990 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1236282
12 May 1989 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1352245
10 June 1988 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 896300
4 May 1988 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1037257
27 May 1987 Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1026425
18 May 1987 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1331887
22 May 1986 Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 984981
30 April 1986 Credit Drydock
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 985447
12 July 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1287147
15 May 1985 Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1287364

Deficiency record · 46

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2025 Resolved
Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either 46 CFR 160.002, 46 CFR 160.005, or 46 CFR 160.055 in sub chapter Q of this chapter or other stand specified by the Commandant... 46 adult sized PFDs found with deteriorated retro reflective tape. Replace with new. Vessel's passenger count is reduced to 103 until new PFDs are placed into proper service.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2025
Resolved 5 May 2025
Resolution: Retro reflective tape renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 30 April 2024 Resolved
Each life jacket must be marked with Type I retro-reflective material approved in 46 CFR 164.018 or other standard specified by the Commandant. 12 adult, and 7 child PFD retro tape found worn, and faded. Replace with new.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 22 May 2024
Resolution: Child PFD retro replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 April 2024 Resolved
A vessel must carry one floating waterlight, unless it is limited to day time operation, in which no waterlight is required. Waterlight was discovered working, but light was dim. Recommend replacement of battery, or replace light with new.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 22 May 2024
Resolution: Waterlight replaced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 11 May 2023 Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Main Deck aft fire extinguisher was deemed not-serviceable during annual servicing by NARDINI fire. Replace with a new 40 B:C.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 May 2023
Resolved 8 June 2023
Resolution: New fire extinguisher placed into service
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 26 April 2022 Resolved
23 lifejackets need new retro reflective tape
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 1 May 2022
Resolution: retro-reflective tape renewed
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 19 October 2021 Resolved
compartment #3 starboard aft outer most two frames wasted
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 15 November 2021
Construction/Loadline › Hull › Side Shell
Issued 21 July 2016 Resolved
2" long X 1/4" wide penetration to the hull due to allision. Sat temp repairs have been made. Permanent repairs to be completed at drydock.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 October 2016
Resolved 19 October 2016
Resolution: Satisfactory permanent repairs completed.
Construction/Loadline › Hull › Weld
Issued 20 October 2008 Resolved
Grind & Re-weld fracture (hole) in way of the Port Side Forward main deck passenger gate & perform a leak test by spraying water on the repair. After completing submit a digital picture and statement to attending Marine Inspector indicating satisfactory repairs were made. Upon receipt the attending MI will amend the vessels COI for a Credit Dry-Dock exam.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2008
Resolved 27 October 2008
Resolution: Received e-mail with statement & attached pictures indicated repairs were made. Cleared CG-835
Stability › Watertight Integrity › General
Issued 17 April 2008 Resolved
Replace missing bolt in watertight cover between compartment 3 and 4. 46 CFR 179.360
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 24 April 2008
Resolution: Recieved e-mail with photo showing missing bolt has been replaced.
Stability › Watertight Integrity › General
Issued 17 April 2008 Resolved
Install metallic valve for fresh water pipe where it penetrates watertight bulkhead between hold 3 and 4. 46 CFR 176
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 24 April 2008
Resolution: Metallic valve installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 17 April 2008 Resolved
Provide battery tray that will prevent batteries from vibrating off of current platform. 46 CFR 183.350
Action required: 705 - Other - as specified
Due 25 April 2008
Resolved 24 April 2008
Resolution: Battery boxes properly secured.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 25 April 2007 Resolved
Collision bulkhead is not watertight at top of bulkhead at the junction with the main deck. Make temporay repairs to the bulkhead piror to carrying passengers for hire and permanent repairs prior to 25 May 2007 to the satisfaction of a Coast Guard Marine Inspector. Provide repair proposal to this office for review prior to conducting repairs.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 4 May 2007
Resolution: Recieved welding report and qualifications of welders.
Engineering › Fuel Oil Service System › Piping
Issued 25 April 2007 Resolved
Electrically bond fuel fill pipe and fuel tank where seperated with nonmetallic hose.
Action required: 705 - Other - as specified
Resolved 25 April 2007
Resolution: Completed
Operations/Management › Drills/Instruction › Not Conducted
Issued 11 June 2004 Resolved
Provide current up-to-date bridge/training logbook IAW46 CFR 122.420.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 21 June 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 11 June 2004 Resolved
Provide up-to-date first aid kit IAW 46 CFR 121.710 & 46 CFR 160.041.
Condition: Unknown
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 21 June 2004
Lifesaving › Visual Distress Signals (General) › Marking
Issued 11 June 2004 Resolved
Properly mark distress signals IAW 46 CFR 122.614.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 June 2004
Resolved 21 June 2004
Construction/Loadline › Hull
Issued 13 November 2003 Resolved
hull has damage to sideshell plating in numorouse areas. owner will be replacing hull bottom from the stearn of vessel forward 12 feet. vessel owner will be replacing sideshell from turn of bildge up 18 inches and under to seam. vessel owner will be providing a complete repair proposal. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2004
Resolved 14 January 2004
Resolution: Replaced all danages areas.
Lifesaving
Issued 2 May 2001 Resolved
ATTACH A 3 - 6 FOOT LANYARD TO WATER LIGHT FROM RING BUOY.
Condition: Unknown
Due 28 June 2001
Resolved 28 June 2001
Construction/Loadline
Issued 2 May 2001 Resolved
REPLACE PVC PIPE CAP WITH A STEEL PIPE CAP ON PORT EXHAUST PIPE.
Condition: Unknown
Due 28 June 2001
Resolved 28 June 2001
Accommodation/Occupational Safety
Issued 2 May 1994 Resolved
Install bow rails that meet the requirements of 46 CFR 177.35 not later than the compliance date. Rail spacing can be no greater than 12 inches.
Condition: Unknown
Due 2 May 1994
Resolved 2 May 1994
Engineering
Issued 14 October 1993 Resolved
RENEW ALL WORN AND ROTTED PADDLEBOARDS ON PADDLEWHEELS NOT LATER THAN THE COMPLIANCE DATE._x001C_ _x001C_
Condition: Unknown
Due 14 October 1993
Resolved 14 October 1993
Construction/Loadline
Issued 3 October 1993 Resolved
Drydock and repair chine damage located starboard side in the #2 and #4 compartments not later than the compliance date. Temporary repairs are to be maintained until permanent repairs are effected.
Condition: Unknown
Due 3 October 1993
Resolved 3 October 1993
Construction/Loadline
Issued 4 May 1993 Resolved
Weld or permanently seal bolt holes located in the starboard gunnel, #1 void space, not later than the compliance date.
Condition: Unknown
Due 4 June 1993
Resolved 9 August 1993
Accommodation/Occupational Safety
Issued 4 May 1993 Resolved
Raise sewage tank vent higher than the toilets not later than the compliance date.
Condition: Unknown
Due 4 June 1993
Resolved 9 August 1993
Accommodation/Occupational Safety
Issued 4 May 1993 Resolved
Provide 42 inch high guards for the lower passenger deck windows not later than the compliance date.
Condition: Unknown
Due 4 June 1993
Resolved 9 August 1993
Navigation
Issued 22 April 1991 Resolved
INSTALL A 135 DEGREE STERN LIGHT AND A 360 DEGREE ANCHOR LIGHT.
Condition: Unknown
Due 22 April 1991
Resolved 22 April 1991
Electrical
Issued 14 May 1990 Resolved
INSTALL BATTERY DISCONNECT SWITCHES IN BOTH BATTERY SETS.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Electrical
Issued 14 May 1990 Resolved
REPAIR/ADJUST PORT MAIN ENGINE AMP METER.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Engineering
Issued 14 May 1990 Resolved
DOUBLE CLAMP ALL FLEX HOSES IN ENGINE COOLING, FIRE/BILGE PIPING, AND HYDRAULIC SYSTEMS.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Engineering
Issued 14 May 1990 Resolved
INSTALL GUARD ON PORT ENGINE.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Electrical
Issued 14 May 1990 Resolved
PROVIDE RUBBER MAT IN FRONT OF MAIN GENERATOR PANEL.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Engineering
Issued 14 May 1990 Resolved
SECURE PORT EXHAUST PIPE.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Navigation
Issued 14 May 1990 Resolved
REPAIR LEAKS IN HYDRAULIC PIPING TO STBD ENGINE IN ENGINE ROOM AND STERN COMPARTMENT.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Lifesaving
Issued 14 May 1990 Resolved
SEPARATE ADULT AND CHILD PFDS.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Lifesaving
Issued 14 May 1990 Resolved
PROVIDE 03 NIGHT AND 06 DAY FLARES.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Fire Fighting
Issued 14 May 1990 Resolved
PROPERLY MOUNT ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Construction/Loadline
Issued 14 May 1990 Resolved
PERMANENTLY REPAIR STAIRWELL DRAIN PIPING IN #3 COMPARTMENT.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Electrical
Issued 14 May 1990 Resolved
REPLACE WIRE NUTS WITH CRIMP FASTNERS IN 12 VOLT SYSTEM AS NECESSARY.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Electrical
Issued 14 May 1990 Resolved
ADJUST GENERATOR TO 120 VOLTS.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Engineering
Issued 4 May 1988 Resolved
PROVIDE LABELING FOR THE BILGE PIPING.
Condition: Unknown
Due 4 May 1988
Resolved 4 May 1988
Electrical
Issued 18 May 1987 Resolved
PROVIDE VOLTMETER, AMMETER AND FREQUENCY METER FOR THE 240 VAC GENERATOR.
Condition: Unknown
Due 18 May 1987
Resolved 18 May 1987
Fire Fighting
Issued 18 May 1987 Resolved
PROVIDE HAND OPERATED PORTABLE FIRE PUMP.
Condition: Unknown
Due 18 May 1987
Resolved 18 May 1987
Construction/Loadline
Issued 18 May 1987 Resolved
INSTALL PROPER TONNAGE OPENING IN ACCORDANCE WITH 46 CFR 69.03-67(H).
Condition: Unknown
Due 18 May 1987
Resolved 18 May 1987
Fire Fighting
Issued 18 May 1987 Resolved
PROVIDE ONE B-II FIRE EXTINGUISHER FOR THE UPPER DECK.
Condition: Unknown
Due 18 May 1987
Resolved 18 May 1987
Electrical
Issued 15 May 1985 Resolved
REPAIR 12 VOLT EMERGENCY LIGHT IN WHEELHOUSE
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985
Engineering
Issued 15 May 1985 Resolved
INSTALL SAFETY LOCKNUTS FOR BOTH ENGINE MORSE CONTROL THROTTLE LINKAGES
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985

Casualty record · 1

21 July 2016Routine · role: Subject to Marine Inspection · activity 5952277
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.