Inspection history · 66
5 September 2013
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4706434
1 August 2013
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4671511
17 July 2013
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4658068
28 June 2012
COI Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4384843
14 June 2012
Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4344550
19 September 2011
Simplified Stability Test · Administrative Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4149980
16 June 2011
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4045623
28 October 2010
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3879685
16 June 2010
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3767878
19 May 2009
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3479706
1 May 2009
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3465138
30 April 2009
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3464354
19 June 2008
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3241363
6 June 2007
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2953514
19 July 2006
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2717901
16 August 2005
Deficiency Check
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2464931
7 July 2005
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 2418034
27 May 2004
Annual Inspection · Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 2091429
30 June 2003
Administrative Inspection
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1831868
19 June 2003
Annual Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1813033
18 June 2002
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1640151
14 May 2002
Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1617038
27 June 2001
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 213020
27 June 2001
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1067376
13 June 2001
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1389418
2 August 2000
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 821824
19 June 2000
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1424941
10 August 1999
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1098278
8 July 1999
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1458647
17 September 1998
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 800123
24 July 1998
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1129656
7 July 1998
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1472803
17 November 1997
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1109553
12 June 1997
Deficiency Check · Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1427389
29 April 1997
Examination of Repairs · Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1452259
23 January 1997
Damage Survey
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1091204
3 December 1996
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 132540
18 July 1996
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1089682
20 September 1995
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 875890
13 July 1995
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1193213
28 February 1995
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 866904
8 June 1994
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1017190
6 June 1994
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1324845
23 March 1994
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 165539
23 March 1994
Damage Survey · Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1448534
8 January 1994
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 163695
11 June 1993
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 846282
4 February 1993
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1143926
24 December 1992
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1140794
2 November 1992
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 935821
25 August 1992
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1247472
12 August 1992
Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1246739
6 January 1992
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1258976
24 July 1991
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1253136
1 July 1991
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1253592
13 June 1991
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 893251
11 June 1991
Administrative
Administrative · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 999996
11 June 1990
COI Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1224942
4 August 1989
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1040492
15 June 1989
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1199563
14 June 1988
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 897284
7 June 1988
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1200382
12 June 1987
COI Inspection · Hull Examination
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1027848
5 August 1986
Deficiency Check
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1305604
14 July 1986
Re-Inspection
Physical examination · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 985663
13 June 1985
Type not recorded
No type recorded · MSO Pittsburgh · USCG Heartland District (CGD-H) · Activity 1286667
Lifesaving › Hand Flares › Expired
Issued 17 July 2013
Resolved
Flares expired. Renew flares.
Action required: 705 - Other - as specified
Due 1 August 2013
Resolved 1 August 2013
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 17 July 2013
Resolved
Separately store Child and adult life jackets.
Action required: 705 - Other - as specified
Due 1 August 2013
Resolved 1 August 2013
Resolution: 5 child life jackets in each storage box were relocated on a separate shelf.
Electrical › Lighting (service) › Outlet Box
Issued 17 July 2013
Resolved
Cover lights in office and operating station or remove.
Action required: 705 - Other - as specified
Due 1 August 2013
Resolved 1 August 2013
Resolution: Lights were not required and were removed.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 17 July 2013
Resolved
Provide 1 more operational flashlight.
Action required: 705 - Other - as specified
Due 1 August 2013
Resolved 1 August 2013
Construction/Loadline › Hull › Hull Plating
Issued 28 June 2012
Resolved
Seal cooling piping hole in deck in Engine Room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 August 2012
Resolved 22 August 2012
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 28 June 2012
Resolved
Remark name on ring bouy which has worn due to weather.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2012
Resolved 22 August 2012
Lifesaving › Rescue Boat Equipment › Paddle/Oar
Issued 28 June 2012
Resolved
Replace fractured oar.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 August 2012
Resolved 22 August 2012
Engineering › Compressed Air System (control) › Receiver/Bottle
Issued 28 June 2012
Resolved
Remove empty, unused CO2 bottle from Engine Room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 August 2012
Resolved 22 August 2012
Documentation › Markings/Placards › Official Number (US)
Issued 28 June 2012
Resolved
Identify location of vessels official number or install the same.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 August 2012
Resolved 22 August 2012
Engineering › Reduction Gearing/Clutches › Gear
Issued 16 June 2011
Resolved
Replace top cable pulley wheel on engine side of ferry and adjust guide pulley on cabin side of ferry so that it is not rubbing on bottom of cabin.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 July 2011
Resolved 30 June 2011
Resolution: Corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 16 June 2011
Resolved
Replace broken light bulb cage in engine room.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 4 July 2011
Resolved 30 June 2011
Resolution: Corrected.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 16 June 2010
Resolved
Replace household light bulbs in navigation lights with proper nav light bulbs.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 October 2010
Resolved 27 October 2010
Resolution: Corrected.
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 16 June 2010
Resolved
Master provide current Restricted Radio Operators Permit as per 47 CFR 80.163.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2010
Resolved 16 September 2010
Resolution: corrected
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 16 June 2010
Resolved
Provided 30x30 mesh flame screen in fuel tank vent pipe.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2010
Resolved 16 September 2010
Resolution: corrected
Engineering › Steering Gear System › Bracket/Clamp
Issued 16 June 2010
Resolved
Re-align engine side cable below operating station in guide wheel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2010
Resolved 16 September 2010
Resolution: corrected
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 16 June 2010
Resolved
Repair or replace chain retainers on 4 deck hatches.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2010
Resolved 16 September 2010
Resolution: corrected
Deck/Cargo › Mooring/Anchoring › Winch
Issued 19 June 2008
Resolved
REPAIR BIG WINCH BRAKE GEAR WHICH IS MISSING TEETH. (GEAR IS ONLY NEEDED WHEN CHANGING CABLES AND STILL CAN BE USED IF NECESSARY.)
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 June 2009
Resolved 30 April 2009
Resolution: BIG WINCH BRAKE GEAR WAS REPLACED.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 7 July 2005
Resolved
Prove proper operation of engine RPM, jacket water temp, and oil pressure gauges.
Due 7 August 2005
Resolved 16 August 2005
Resolution: New gauges installed and operating properly.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 May 2004
Resolved
Ensure contents of first aid kit meets requirements of 46 CFR 160.041-4
Condition: Improper/Lack of Maintenance
Due 26 June 2004
Resolved 1 July 2004
Resolution: New first aid kit placed on board.
Electrical › Electric Supply System (service) › Battery Installation
Issued 27 May 2004
Resolved
Provide a corrosion resistant liner for the battery box.
Condition: Improper Installation
Due 1 August 2004
Resolved 5 August 2004
Resolution: A new plastic battery box was installed.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 27 May 2004
Resolved
Maintain a log of fire and man overboard drills.
Due 26 June 2004
Resolved 1 July 2004
Resolution: A logbook for drills was placed on board.
Construction/Loadline › Structures › Door
Issued 27 May 2004
Resolved
Repair broken engine room door knob (pulled off in my hand when closing door).
Condition: Improper/Lack of Maintenance
Due 1 August 2004
Resolved 5 August 2004
Resolution: Door knob repaired.
Fire Fighting › Fire Pumps › Impeller
Issued 26 May 2004
Resolved
Prove proper operation of the required portable fire/bilge pump equipped with electric start. Corrected on scene.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 June 2004
Resolved 26 June 2004
Resolution: Repaired pump arrived during inspection, was reinstalled and operation tested sat.
Fire Fighting › Fire Pumps
Issued 30 June 2003
Resolved
Renew and prove proper operation of the vessels fire main system (pump and associated equipment) per the vessel's COI and 46 CFR Part 181 Subpart C (sections 181.300 thru 181.320)
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 July 2003
Resolved 11 July 2003
Resolution: New fire pump installed.
Engineering › Bilge Water Management System
Issued 19 June 2003
Resolved
Renew intake and discharge hoses on hand portable bilge pump. LEGACY COMPONENT DESC: Hose
Condition: Improper/Lack of Maintenance
Due 19 July 2003
Resolved 11 July 2003
Resolution: New hoses installed.
Electrical › Electrical Distribution System (service)
Issued 19 June 2003
Resolved
Renew the trickle charge feed wire for the battery on the fire pump. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Due 19 July 2003
Resolved 11 July 2003
Resolution: New fire pump installed. Wiring run inside flex conduit.
Lifesaving › Hand Flares
Issued 2 July 2002
Resolved
FLARES EXPIRED. GET NEW ONES. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2002
Resolved 2 July 2002
Resolution: CORRECTED.
Lifesaving › Lifebuoys
Issued 2 July 2002
Resolved
PROVIDE STROBE LIGHT FOR RING BUOY. LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 2 July 2002
Resolved 2 July 2002
Resolution: CORRECTED.
Fire Fighting › Fire Pumps
Issued 2 July 2002
Resolved
REPAIR MANUAL PULL START. LEGACY COMPONENT DESC: Bearings
Condition: Unknown
Action required: 705 - Other - as specified
Due 2 July 2002
Resolved 2 July 2002
Resolution: CORRECTED
Fire Fighting › Fire Hoses
Issued 2 July 2002
Resolved
25 FT OF FIREHOSE ONBOARD. PROVIDE 75 MORE FEET. LEGACY COMPONENT DESC: Number
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 July 2002
Resolved 2 July 2002
Resolution: CORRECTED.
Accommodation/Occupational Safety › Medical/First Aid
Issued 2 July 2002
Resolved
PROVIDE UPDATED FIRST AID KIT. CURRENT KIT MOSTLY EMPTY. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2002
Resolved 2 July 2002
Resolution: CORRECTED.
Deck/Cargo › Mooring/Anchoring
Issued 2 July 2002
Resolved
ROTTEN 1 INCH ANCHOR LINE PARTED VIA HAND PULL. REPLACE IT. LEGACY COMPONENT DESC: Anchor Rope
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2002
Resolved 2 July 2002
Resolution: CORRECTED.
Engineering › Steering Gear System
Issued 2 July 2002
Resolved
PROPERLY ADJUST THE CABLE AND PULLY SYSTEMS SO THAT THE FERRY FREDERICK MAINTAINS SAFE OPERATION. LEGACY COMPONENT DESC: Feedback Unit
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 July 2002
Resolved 2 July 2002
Resolution: CORRECTED.
Electrical › Electrical Distribution System (service)
Issued 15 May 2002
Resolved
Cables were not connected with locking/crimp connections. Many wires were simply twisted and exposed. Require all connections be repaired IAW 46 CFR 183.340(g). LEGACY COMPONENT DESC: Cable
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2002
Resolved 22 May 2002
Electrical › Electric Supply System (service)
Issued 15 May 2002
Resolved
Overhead wires were secured with plastic wire ties and/or tape. Require to replace with metal ties. LEGACY COMPONENT DESC: Cable
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 22 May 2002
Electrical › Electrical Distribution System (service)
Issued 15 May 2002
Resolved
Repair fuse box with proper breaker box in engine room. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 22 May 2002
Engineering › Non-conventional Propulsion/Steering
Issued 15 May 2002
Resolved
Guides and pulleys were mis-aligned and worn. Replace and renew all cable pulleys, guides and supports.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 22 May 2002
Construction/Loadline › Structures
Issued 15 May 2002
Resolved
Deck at operator station wasted. Crop and renew. LEGACY COMPONENT DESC: Deck Plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 22 May 2002
Deck/Cargo › Cargo Transfer (solid)
Issued 15 May 2002
Resolved
Bolts on vehicle boarding ramp were warped and worn. Replace bolts on FWD & AFT vehicel boarding ramps.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 22 May 2002
Construction/Loadline › Penetrations
Issued 15 May 2002
Resolved
Remove and clean keel coolers and boxes for inspection. LEGACY COMPONENT DESC: Pipe Flange
Action required: 705 - Other - as specified
Due 24 May 2002
Resolved 22 May 2002
Unknown
Issued 13 June 2001
Resolved
PROVIDE CPR TRAINING FOR CREW QUALIFICATIONS
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Unknown
Issued 13 June 2001
Resolved
COMPLETE ANNUAL DRUG AUDIT
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Documentation
Issued 13 June 2001
Resolved
POST STABILITY LETTER
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Lifesaving
Issued 13 June 2001
Resolved
REPLACE WEARING RETRO REFLECTIVE TAPE ON LIFEJACKET.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Unknown
Issued 13 June 2001
Resolved
PROVIDE PASSENGER COUNT ON SHORE.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Lifesaving
Issued 13 June 2001
Resolved
PUT RETRO REFLECTIVE TAPE ON RING BUOY.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Unknown
Issued 13 June 2001
Resolved
PROVIDE PASSENGER SAFETY ORIENTATION.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Lifesaving
Issued 13 June 2001
Resolved
PROVIDE TWO TOTAL FLASHLIGHT.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Accommodation/Occupational Safety
Issued 13 June 2001
Resolved
REPLACE GARBAGE PLACARD.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Lifesaving
Issued 13 June 2001
Resolved
REPAIR DOORHANDLE TO ENGINE ROOM.
Condition: Unknown
Due 13 June 2001
Resolved 13 June 2001
Documentation
Issued 19 June 2000
Resolved
CARRY ORIGINAL DOCUMENTATION CERTIFICATE WITH CURRENT ENDORSEMENTS_x001C_ ON BOARD THE VESSEL AS REQUIRED BY 46 CFR 67.313.
Condition: Unknown
Due 19 June 2000
Resolved 19 June 2000
Fire Fighting
Issued 8 July 1999
Resolved
SERVICE B-II FIRE EXTINGUISHER LOCATED INSIDE BREAK/STORAGE AREA.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Engineering
Issued 8 July 1999
Resolved
REPAIR/REPLACE OIL PRESSURE GAUGE ON MAIN ENGINE TO THE SATISFACTION OF THECOGNIZANT OCMI.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Engineering
Issued 8 July 1999
Resolved
ROUTE CRANKCASE VENT PIPE INTERNALLY SO AS NOT TO DISCHARGE OVERBOARD.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Lifesaving
Issued 8 July 1999
Resolved
PROVIDE COAST GUARD APPROVED FIRST AID KIT.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Engineering
Issued 8 July 1999
Resolved
PROVIDE PROPER REPAIR TO EMERGENCY SHUTDOWN ON MAIN ENGINE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 8 July 1999
Resolved 8 July 1999
Lifesaving
Issued 7 July 1998
Resolved
Emergency Check List worn/faded due to weather. Still readable but I required replacement and advised vsl rep I would let them use the current Emergency Check List until a new one was installed.
Condition: Unknown
Due 20 July 1998
Resolved 5 August 1998
Navigation
Issued 7 July 1998
Resolved
Pull chain and hammer on ships bell rusted in place. After being freed up the tone of the bell didn't sound loud enough to me. It was a side mountedsteel alarm "clanger" and not the bell design required in NAVRULS. Vsl notto get underway in restricted visibility until ships bell is replaced.
Condition: Unknown
Due 20 July 1998
Resolved 5 August 1998
Fire Fighting
Issued 7 July 1998
Resolved
Portable fire and bilge pump battery needed charged. Pump has alternate manual start via pull cord and was started during this inspection on the first pull. Vsl rep states they are going to wire battery into charger to alleviate this problem in the future. Battery is to be reinstalled today.
Condition: Unknown
Due 7 July 1998
Resolved 13 July 1998
Lifesaving
Issued 12 June 1997
Resolved
STORE ALL FLAMABLE LIQUIDS IN SUITABLE LOCKER.
Condition: Unknown
Due 2 March 1998
Resolved 2 March 1998
Fire Fighting
Issued 12 June 1997
Resolved
FIRE EXTINGUISHER IN CABIN NEEDS TO BE SERVICED PRIOR TO VESSEL GETTNG U/W.
Condition: Unknown
Due 13 June 1997
Resolved 22 July 1997
Construction/Loadline
Issued 12 June 1997
Resolved
Submit proposal to the OCMI for installation of a fixed bilge and firemain system in accordance with 46CFR182.510
Condition: Unknown
Due 1 January 1998
Resolved 2 March 1998
Lifesaving
Issued 12 June 1997
Resolved
REPLACE 20 ADULT LIFEJACKETS. VESSEL MAY NOT CARRY MORE THAN 10 ADULTS UNTIL A SUFFICIENT NUMBER OF ADULT LIFEJACKETS ARE ON BOARD.
Condition: Unknown
Due 12 July 1997
Resolved 12 September 1997
Navigation
Issued 12 June 1997
Resolved
REPAIR OR REPLACE MALFUNCTIONING MARINE RADIO. CHANNEL 13 NOT WORKING PROPERLY.
Condition: Unknown
Due 22 August 1997
Resolved 12 September 1997
Lifesaving
Issued 12 June 1997
Resolved
INSTALL NO SMOKING SIGNS ON VEHICLE DECK.
Condition: Unknown
Due 2 March 1998
Resolved 2 March 1998
Lifesaving
Issued 12 June 1997
Resolved
REMOVE PORTABLE OPEN FLAME TYPE KEROSENE HEATER.
Condition: Unknown
Due 2 March 1998
Resolved 2 March 1998
Documentation
Issued 12 June 1997
Resolved
OBTAIN UPDATED COPY OF CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 12 July 1997
Resolved 22 July 1997
Deck/Cargo
Issued 12 June 1997
Resolved
ADD SECOND SAFETY CABLE, ONE AT EACH END OF FERRY AS PER SECOND DISTRICT INSTRUCTION.
Condition: Unknown
Due 22 August 1997
Resolved 12 September 1997
Construction/Loadline
Issued 12 June 1997
Resolved
Repair numerous holes in engine compartment deck.
Condition: Unknown
Due 2 March 1998
Resolved 2 March 1998
Construction/Loadline
Issued 12 June 1997
Resolved
REPLACE EXISITNG PORTABLE FIRE AND BILGE PUMP WITH A NEW PORTABLE, SELF PRIMING PUMP EQUIPPED WITH ELECTRIC STARTING SYSTEM AND 25 GAL. PER. MIN. CAPACITY.
Condition: Unknown
Due 2 March 1998
Resolved 2 March 1998
Engineering
Issued 12 June 1997
Resolved
REPLACE MAIN DRIVE SPROCKET TAPERED HUB. HUB WAS FOUND TO HAVE NUMEROUS CRACKS THROUGHOUT, SOME IN PREVIOUS REPAIRS.
Condition: Unknown
Due 22 August 1997
Resolved 12 September 1997
Navigation
Issued 12 June 1997
Resolved
PRIOR TO RUNNING AT NIGHT, REPLACE PORT AND STARBOARD RUNNING LIGHT BULBS.
Condition: Unknown
Due 13 June 1997
Resolved 12 September 1997
Construction/Loadline
Issued 23 January 1997
Resolved
Make permanent repairs to damaged area of cabin wall.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 23 January 1997
Resolved
Make permanent repairs to main drive chain, sprocket, bull gear and cable guide assemblies.
Condition: Unknown
Due 23 January 1997
Resolved 23 January 1997
Engineering
Issued 13 July 1995
Resolved
Provide emergency shut-off for main propulsion fuel tank. Shut-off is to belocated outside of machinery space.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Documentation
Issued 13 July 1995
Resolved
Provide and keep onboard the vessel the original copy of the Certificate ofDocumentation.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Lifesaving
Issued 13 July 1995
Resolved
Replace boat fall blocks and raise and lower rescue boat.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Deck/Cargo
Issued 13 July 1995
Resolved
Replace all wasted fasteners on the safety cable holding devices. Ensure all four devices are securely tightened.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Accommodation/Occupational Safety
Issued 13 July 1995
Resolved
Install clips for holding chain link fence more securely on vessel side rails.
Condition: Unknown
Due 13 July 1995
Resolved 13 July 1995
Navigation
Issued 8 June 1994
Resolved
RENEW THE CORD FOR THE VHF RADIO MICROPHONE.
Condition: Unknown
Due 30 June 1994
Resolved 26 July 1994
Fire Fighting
Issued 8 June 1994
Resolved
PROVIDE STRAINER FOR 2" FIRE/BILGE PUMP SUCTION LINE.
Condition: Unknown
Due 8 June 1994
Resolved 8 June 1994
Lifesaving
Issued 8 June 1994
Resolved
MARK NEW LIFERING WITH THE NAME OF THE VESSEL AS REQUIRED BY _x001C_ 46CFR 185.30-5.
Condition: Unknown
Due 30 June 1994
Resolved 26 July 1994
Accommodation/Occupational Safety
Issued 8 June 1994
Resolved
RENEW THE WINDOW GLASS WHERE CRACKED OR MISSING
Condition: Unknown
Due 30 June 1994
Resolved 26 July 1994
Lifesaving
Issued 8 June 1994
Resolved
CLEAN OUT DIRT AND DEBRIS FROM BOTTOM OF LIFEJACKET LOCKERS
Condition: Unknown
Due 8 June 1994
Resolved 8 June 1994
Lifesaving
Issued 8 June 1994
Resolved
RENEW THE LIFEJACKET WEARING INSTRUCTIONS.
Condition: Unknown
Due 8 June 1994
Resolved 8 June 1994
Electrical
Issued 8 June 1994
Resolved
CLEAN OUT BATTERY BOX.
Condition: Unknown
Due 31 August 1994
Resolved 26 July 1994
Navigation
Issued 8 June 1994
Resolved
PRIOR TO OPERATION OF FERRY IN RESTRICTED VISIBILITY, REPAIRS ARE TO BE MADE TO THE EXTINQUISHED GREEN DOWN RIVER RUNNING LIGHT.
Condition: Unknown
Due 30 June 1994
Resolved 26 July 1994
Lifesaving
Issued 8 June 1994
Resolved
RENEW RESCUE BOAT FALLS (PULLEYS AND LINES) AS NEEDED.
Condition: Unknown
Due 30 June 1994
Resolved 26 July 1994
Lifesaving
Issued 8 June 1994
Resolved
PROVIDE SEPERATION OF THE CHILD/ADULT LIFEJACKETS IN THE DOWN RIVER LOCKER
Condition: Unknown
Due 8 June 1994
Resolved 8 June 1994
Engineering
Issued 23 March 1994
Resolved
INSPECT AND REPAIR AS NECESSARY MAIN DRIVE REAR END.
Condition: Unknown
Due 30 April 1994
Resolved 15 April 1994
Engineering
Issued 23 March 1994
Resolved
INSTALL SAFETY GUARDS AS NECESSARY.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Engineering
Issued 23 March 1994
Resolved
REPAIR OR REPALCE MAIN DRIVE SHAFT.
Condition: Unknown
Due 30 April 1994
Resolved 15 April 1994
Engineering
Issued 23 March 1994
Resolved
MAKE PERMANENT REPAIRS TO MAIN DRIVE SHAFT AND BULL WHEEL AND IDLER SHAFT AND BULL WHEEL.
Condition: Unknown
Due 30 April 1994
Resolved 15 April 1994
Construction/Loadline
Issued 23 March 1994
Resolved
REPAIR HOLES AS REQUIRED IN ENGINE ROOM BULKHEAD.
Condition: Unknown
Due 23 March 1994
Resolved 23 March 1994
Engineering
Issued 23 March 1994
Resolved
REPLACE MAIN DRIVE CABLE.
Condition: Unknown
Due 30 April 1994
Resolved 15 April 1994
Engineering
Issued 23 March 1994
Resolved
REPAIR MAIN DRIVE CHAIN AND SPROCKET.
Condition: Unknown
Due 30 April 1994
Resolved 15 April 1994
Lifesaving
Issued 13 June 1991
Resolved
_x001C_ RENEW THE GRABLINES FOR THE LIFE RING.
Condition: Unknown
Due 30 June 1991
Resolved 16 July 1991
Electrical
Issued 13 June 1991
Resolved
PROPERLY WIRE AND INSTALL THE FM/AM RADIO IN ACCORDANCE WITH SUB CHAPTER "T" ELECTRICAL REGULATIONS OR REMOVE THE RADIO FROM THE VESSEL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 June 1991
Resolved 16 July 1991
Lifesaving
Issued 13 June 1991
Resolved
PROPERLY DISPLAY THE EMERGENCY INSTRUCTIONS AS REQUIRED BY 46CFR185.25
Condition: Unknown
Due 30 June 1991
Resolved 16 July 1991
Fire Fighting
Issued 13 June 1991
Resolved
PROVIDE ONBOARD AN ADDITIONAL 50 FOOT LENGTH OF 5/8" COMMERCIAL GRADE OF GARDEN FOR FIREFIGHTING SERVICE AS REQUIRED BY THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 30 June 1991
Resolved 16 July 1991
Electrical
Issued 13 June 1991
Resolved
PROPERLY REWIRE AND MOUNT THE LIGHTING FIXTURE THAT IS LOCATED IN THE OVERHEAD OF THE UPRIVER SHANTY.
Condition: Unknown
Due 30 June 1991
Resolved 16 July 1991
Engineering
Issued 13 June 1991
Resolved
PROPERLY IDENTIFY AND MARK THE EMERGENCY FUEL SHUTOFF VALVES AT BOTH FUEL TANKS AS REQUIRED BY 46CFRR 185.30-20.
Condition: Unknown
Due 30 June 1991
Resolved 16 July 1991
Documentation
Issued 13 June 1991
Resolved
PROVIDE AND MAINTAIN ONBOARD THE VESSEL THE MARINE DOCUMENT
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Construction/Loadline
Issued 13 June 1991
Resolved
PROVIDE AND MAINTAIN ONBOARD THE VESSEL A DOGGING WRENCH (SECURING HANDLE),FOR THE MAIN DECK SCUTTLE COVERS.
Condition: Unknown
Due 16 July 1991
Resolved 16 July 1991
Fire Fighting
Issued 13 June 1991
Resolved
PROPERLY DISPLAY THE "NO SMOKING" SIGNS AS REQUIRED BY 46CFR 185.20-20(C)._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 June 1991
Resolved 16 July 1991
Documentation
Issued 13 June 1991
Resolved
_x001C_ PROPERLY DISPLAY THE OIL POLLUTION PLACARD AS REQUIRED BY 33CFR 155.450.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Navigation
Issued 13 June 1991
Resolved
POST AT THE OPERATORS PLATFORM THE PERSON IN CHARGE RESPONSIBILITIES AS OUTLINED IN 46CFR185.20.20
Condition: Unknown
Due 30 June 1991
Resolved 16 July 1991
Navigation
Issued 15 June 1989
Resolved
ENLARGE WINDOWS IN DOORS OF ENGINE ROOM TO ACCOMADATE PILOT'S UNRESTRICTED VISION FOR NAVIGATION.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Lifesaving
Issued 7 June 1988
Resolved
PLACE ONE ADDITIONAL APPROVED ADULT SIZE LIFE PRESERVER ONBOARD VESSEL.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Navigation
Issued 7 June 1988
Resolved
RESTORE PORT AND STBD RUNNING LIGHTS TO FULLY OPERATIONAL CONDITION PRIOR TO OPERATING IN REDUCED VISABILITY.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Lifesaving
Issued 7 June 1988
Resolved
REPLACE LINE ON RING BOUY.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Lifesaving
Issued 7 June 1988
Resolved
REPLACE RESCUE BOAT DAVIT LINES.
Condition: Unknown
Due 7 June 1988
Resolved 7 June 1988
Electrical
Issued 14 July 1986
Resolved
INSTALL COVER ON VOLTAGE REGULATOR ON DRIVE ENGINE.
Condition: Unknown
Due 14 July 1986
Resolved 14 July 1986
Lifesaving
Issued 14 July 1986
Resolved
REPLACE ONE (1) ADULT TYPE 1 PFD.
Condition: Unknown
Due 14 July 1986
Resolved 14 July 1986
Engineering
Issued 14 July 1986
Resolved
MAKE PERMANENT REPAIRS TO NUMEROUS OIL LEAKS ON DRIVE ENGINE.
Condition: Unknown
Due 14 July 1986
Resolved 14 July 1986
Fire Fighting
Issued 14 July 1986
Resolved
REPLACE NOZZLE FOR 3/4" FIRE HOSE.
Condition: Unknown
Due 14 July 1986
Resolved 14 July 1986
Electrical
Issued 14 July 1986
Resolved
REMOVE WIRE SPLICES THROUGHOUT THE VESSEL.
Condition: Unknown
Due 14 July 1986
Resolved 14 July 1986
Engineering
Issued 14 July 1986
Resolved
REMOVE RAGS FROM DRIVE ENGINE.
Condition: Unknown
Due 14 July 1986
Resolved 14 July 1986