Records from 1985 to 2025. Most recent: inspection, 20 September 2025.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 56
20 September 2025
Type not recorded
No type recorded · Station Sandy Hook · USCG Northeast District (CGD-NE) · Activity 8238653
24 March 2025
Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8098629
24 March 2025
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8098720
19 December 2024
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8049005
2 February 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7630637
5 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7169110
1 April 2021
Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7166941
16 July 2020
COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6906045
2 July 2019
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6681191
17 April 2019
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6629654
23 April 2018
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6363339
27 April 2017
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6131580
5 April 2017
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6118071
3 May 2016
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5867881
5 May 2014
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 4850678
12 February 2010
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3679075
23 April 2009
Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3458742
1 November 2008
Type not recorded
No type recorded · Station Montauk · USCG Northeast District (CGD-NE) · Activity 3355635
13 May 2008
Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3205249
27 March 2008
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3171847
7 May 2007
Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2917095
1 May 2006
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2637613
20 March 2006
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2603775
25 April 2005
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2342014
19 January 2005
Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2273397
29 April 2003
Internal Structural Exam · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1779710
27 January 2003
Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1733833
25 April 2002
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1606800
1 April 2001
Hull Examination · MARPOL Annex V Examination · Re-Inspection · Plan Review "T" Boat
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1441782
19 April 2000
MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1459605
1 April 2000
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1457768
31 March 2000
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1413686
30 March 2000
Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1460387
13 May 1999
Plan Review "T" Boat · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1437566
29 April 1999
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1126617
14 January 1999
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1046018
11 January 1999
Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1473443
9 April 1998
Re-Inspection · MARPOL Annex V Examination · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1408063
29 April 1997
MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1094908
10 May 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084248
18 April 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084233
28 April 1995
MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 878290
28 April 1994
MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 864287
27 April 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 842751
28 March 1992
Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261177
30 April 1991
Deficiency Check · Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1270755
22 January 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1303559
14 May 1990
Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1242624
19 April 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202921
17 October 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1196970
2 May 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1041899
11 May 1987
Deficiency Check · Hull Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1321428
27 April 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1003219
21 May 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1289540
2 May 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1291376
3 January 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1284023
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 14 April 2025
Resolved
The light must be a floating watertight approved under approval series 161.010 or other standard specified by the Commandant. Lifefloat light found extinguished.
46 CFR 180.175(f)(4)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2025
Resolution: Def check 17Apr25
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 April 2025
Resolved
An adult life jacket must be provide for each person carried on board a vessel. Lifejackets found not suitable for service. Replace with serviceable and approved lifejackets.
46 CFR 180.71(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2025
Resolution: New deficiency issued that allows reduced PAX count.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 April 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. Vessel found missing operating light.
46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 17 April 2025
Resolution: Def check conducted by MI report satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 April 2025
Resolved
Table (1) to 181.500(b) indicates the minimum required classification for each space listed. Vessel's fire extinguishers found not mounted in proper locations.
46 CFR 181.500(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 May 2025
Resolution: Recieved email and picture from owner of fire extinguishers mounted onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 April 2025
Resolved
Gears, couplings, flywheels, and all rotating machinery capable of injuring personnel must be provided with adequate covers or guards. Main Diesel Engine missing covers for belts.
46 CFR 58.01-20
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 May 2025
Resolution: Recieved email and pictures attesting to covers being installed in the engine room
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 April 2025
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent. Vessel missing required closures for engine room space.
46 CFR 182.465(h)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Recieved plan and pictures of closures fabricated and installed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 14 April 2025
Resolved
Complete but simple instructions for the operation of a fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and stop valve control and in the space where the extinguishing agent cylinders are stored. Vessel missing operating instructions for fixed CO2 system.
46 CFR 185.612(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2025
Resolution: Recieved email and pictures from vessel showing CO2 operating instructions created.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 March 2025
Resolved
An adult life jacket must be provide for each person carried on board a vessel. Lifejackets found not suitable for service. Vessel restricted passenger count to 24 adults and 3 children due to life jacket shortage. Vessel must provide satisfactory evidence of replacement prior to carrying more passengers than described above.
46 CFR 180.71(a)
Action required: 705 - Other - as specified
Resolved 13 May 2025
Resolution: Owner email stating remaining lifejackets replaced.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 5 April 2021
Resolved
Complete credit dry dock and internal structural exam IAW 46 CFR 176.600 prior to operating.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 April 2021
Resolved 24 March 2025
Resolution: Completed, see Activities 763-637 & 8049005 from Sector Delaware Bay.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 16 July 2020
Resolved
EPIRB hydrostatic release expired. Restrict operations to less than 3 miles from shore. Hydrostatic release expired 11/2018.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2020
Resolved 30 September 2020
Resolution: RCVD proof of purchase/ scanned reciept and photo of installation on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 16 July 2020
Resolved
Vessel not authorized cold water operations. Vessel's Boyant Apperatus was identified waterlogged and unserviceable. Replace Bouyant Apperatus to resume cold water operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 July 2020
Resolved 30 September 2020
Resolution: RCVD scann of reciept and photo of new 22 person life float installed
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 16 July 2020
Resolved
Establish, Create and maintain life saving maintenance records and logs.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2020
Resolved 31 July 2020
Resolution: Recieved photo evidence of a new maintenance log created. On 9/17/2020 attended vessel to verify log entries and maintenance.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 16 July 2020
Resolved
Provide 1 40 B:C PFE IAW COI fire fighting equipment listed
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 July 2020
Resolved 22 July 2020
Resolution: 40 B:C purchased and installed. Photo evidence sent with receipts of purchase.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 July 2020
Resolved
Oil pressure guages at the operating station were inoperable. Issued requirement to prove proper operation of the oil pressure guages.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2020
Resolved 17 September 2020
Resolution: Observed MDE oil guage operational at the operating station.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 July 2019
Resolved
Properly install 20 amp charger
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 16 July 2020
Resolution: Inspected Satisfactory.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 July 2019
Resolved
Properly install/clean up DC wiring under navigation panel
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 16 July 2020
Resolution: Inspected Satisfactory
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 July 2019
Resolved
Install correct guage for length of run/amperage for new install alternator to charging circuit
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 16 July 2020
Resolution: Inspected Satisfactory
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 July 2019
Resolved
Clean up wiring harnesses for MDE's
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2019
Resolved 16 July 2020
Resolution: Inspected Satisfactory
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 July 2019
Resolved
Demonstrate new fuel lines meet SAE requirements for service and length of install
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 16 July 2020
Resolution: Inspected Satisfactory
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 5 May 2014
Resolved
Provide (01) B-II portable fire extinguisher.
Due 19 May 2014
Resolved 8 May 2014
Resolution: Received email proof of completion of CG-835.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 May 2014
Resolved
Provide aspirn for first aid kit.
Due 19 May 2014
Resolved 8 May 2014
Resolution: Received email proof of completion of CG-835.
Navigation › Piloting/Steering › Marine Charts
Issued 5 May 2014
Resolved
Provide current charts for local area of operation.
Due 9 May 2014
Resolved 8 May 2014
Resolution: Received email proof of completion of CG-835.
Engineering › Fuel Oil Service System › Piping
Issued 5 May 2014
Resolved
Replace F/O fill piping prior to credit ISE.
Action required: 705 - Other - as specified
Resolved 17 March 2015
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 May 2014
Resolved
Repair or Replace bilge pump float switch portside compt# 2
Due 9 May 2014
Resolved 8 May 2014
Resolution: Received email proof of completion of CG-835.
Electrical › Electric Supply System (service) › Battery Charger
Issued 5 May 2014
Resolved
Remove unapproved battery charger installtion.
Due 9 May 2014
Resolved 8 May 2014
Resolution: Received email proof of completion of CG-835.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 May 2014
Resolved
Repair or replace mast anchor light prior night operation.
Action required: 705 - Other - as specified
Resolved 8 May 2014
Resolution: Received email proof of completion of CG-835.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 5 May 2014
Resolved
Replace floatlight for BA.
Due 8 May 2014
Resolved 8 May 2014
Resolution: Received email proof of completion of CG-835.
Lifesaving › Buoyant Apparatus › Marking
Issued 5 May 2014
Resolved
Properly label new BA with vessel name and passenger count.
Due 5 May 2014
Resolved 8 May 2014
Resolution: Received email proof of completion of CG-835.
Lifesaving › Lifejacket/PFD (Type II) › Quantity
Issued 5 May 2014
Resolved
Provide (02) Adult LJ.
Due 5 May 2014
Resolved 8 May 2014
Resolution: Received email proof of completion of CG-835.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 May 2014
Resolved
Provide fix firefighting servicing report,
Due 5 May 2014
Resolved 8 May 2014
Resolution: Received email proof of completion of CG-835.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 23 April 2009
Resolved
One BII fire extiguisher was off vessel for servicing/replacement.
Condition: Unknown
Due 23 April 2009
Resolved 24 April 2009
Construction/Loadline › Hull › Side Shell
Issued 27 March 2008
Resolved
Minor gouge in stem approximately 1 ft above waterline caused by impact with anchor fluke. Gouge is approximately 3/8" deep and 2" long. Surface damage only. Not structurally significant.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 March 2008
Resolved 27 March 2008
Resolution: FRP sheathing removed. Wood of stem found sat and gouge filled w/ West Epoxy and FRP sheathing replaced.
Communications › Radio Communications › EPIRB
Issued 7 May 2007
Resolved
Register EPIRB with FCC.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2007
Lifesaving › Hand Flares › Expired
Issued 7 May 2007
Resolved
Replace flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2007
Navigation › Piloting/Steering › Magnetic Compass
Issued 7 May 2007
Resolved
Owner had removed Compass, required compass to be reinstalled.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 May 2007
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 1 May 2006
Resolved
Replace bridge window.
Due 8 May 2006
Resolved 2 May 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activty.
Lifesaving › Buoyant Apparatus › Float-free Link
Issued 1 May 2006
Resolved
Replace weak link for buoyant apparatus prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activty.
Lifesaving › Buoyant Apparatus › Floating Electric Waterlight
Issued 1 May 2006
Resolved
Provide longer lanyard for buoyant apparatus waterlight.
Due 6 May 2006
Resolved 3 May 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activty.
Electrical › Lighting (service) › Lighting Fixture
Issued 1 May 2006
Resolved
Replace forward compartment light fixture with globe-protected, switch equipped fixture.
Due 15 May 2006
Resolved 3 May 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activty.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 1 May 2006
Resolved
Re-stencil lifejackets as necessary.
Due 15 May 2006
Resolved 4 May 2006
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activty.
Navigation › Piloting/Steering › Magnetic Compass
Issued 25 April 2005
Resolved
Replace Compass.
Due 10 May 2005
Resolved 7 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Communications › Alarms/Indicators › Propeller Revolutions Rate Indicator
Issued 25 April 2005
Resolved
Install tachometers for main engine.
Due 10 May 2005
Resolved 7 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 April 2005
Resolved
Prove proper operation of anchor light.
Due 10 May 2005
Resolved 7 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 25 April 2005
Resolved
Install new retro-reflective tape on buoyant apparatus.
Due 10 May 2005
Resolved 7 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 25 April 2005
Resolved
Stencil vessel name on 5 adult lifejackets.
Due 10 May 2005
Resolved 7 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 25 April 2005
Resolved
Mark electrical controls in pilothouse.
Due 10 May 2005
Resolved 7 May 2005
Resolution: Per fax ltr fm O/O, ltr scanned into documents for this activity.
Lifesaving › Lifejacket/PFD (Type I)
Issued 29 April 2003
Resolved
Provide 1 adult PFD, label 1 pfd w/ vessel name. Vessel restricted to carrying no more than 48 passengers until complete. LEGACY COMPONENT DESC: Quantity
Due 9 May 2003
Resolved 29 April 2003
Resolution: One purchaed, one Labeled and stowed.
Navigation › Collision/Grounding Avoidance
Issued 29 April 2003
Resolved
Repair connection on stern light & remove exposed wires. LEGACY COMPONENT DESC: Navigation Lights
Due 9 May 2003
Resolved 29 April 2003
Resolution: Stern light reinstalled. Exposed wires tied into deck lighting. No exposed wires left.
Lifesaving › Lifejacket/PFD (General)
Issued 29 April 2003
Resolved
Provide separation between child and adult PFDs. LEGACY COMPONENT DESC: Storage
Condition: Placed in Improper Service
Due 9 May 2003
Resolved 29 April 2003
Resolution: Plywood wall installed as separation.
Lifesaving › Buoyant Apparatus
Issued 29 April 2003
Resolved
Remove zip ties from lifefloat.
Due 9 May 2003
Resolved 29 April 2003
Resolution: Renewed with ties that take less strength to break.
Accommodation/Occupational Safety › Medical/First Aid
Issued 29 April 2003
Resolved
Provide aspirin for first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 9 May 2003
Resolved 29 April 2003
Resolution: Purchased aspirin.
Fire Fighting › Miscellaneous Items
Issued 29 April 2003
Resolved
Provide 3 fire buckets.
Due 9 May 2003
Resolved 30 April 2003
Resolution: Three buckets labeled and stowed.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 29 April 2003
Resolved
Reinstall fixed fire system bottles. LEGACY COMPONENT DESC: Tanks
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2003
Resolved 30 April 2003
Resolution: Bottles installed.
Communications › Alarms/Indicators
Issued 29 April 2003
Resolved
Prove proper operation of bilge high level alarms. LEGACY COMPONENT DESC: Bilge Alarm
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2003
Resolved 29 April 2003
Resolution: New float switch installed in bow compartment. Wiring replaced on stern float switch.
Operations/Management › Drills/Instruction
Issued 29 April 2003
Resolved
Conduct and log MOB and fire drills. LEGACY COMPONENT DESC: Man Overboard Recovery
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2003
Resolved 30 April 2003
Resolution: Crew training in fire fighting, man over board, abandon ship & drills condcuted.
Communications › Radio Communications
Issued 25 April 2002
Resolved
Provide FCC radio operator's permit.
Condition: Unknown
Due 10 May 2002
Resolved 9 May 2002
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 April 2002
Resolved
Renew contents of First Aid Kit. IAW 46 CFR 184.710.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2002
Resolved 9 May 2002
Lifesaving › Buoyant Apparatus
Issued 25 April 2002
Resolved
Renew detachable clip for ring buoy water light.
Condition: Improper/Lack of Maintenance
Due 10 May 2002
Resolved 9 May 2002
Lifesaving › Lifejacket/PFD (General)
Issued 25 April 2002
Resolved
Separate location of child and adult life jackets. LEGACY COMPONENT DESC: Storage
Condition: Unknown
Due 10 May 2002
Resolved 9 May 2002
Lifesaving › Buoyant Apparatus
Issued 25 April 2002
Resolved
Provide new painter for buoyant apparatus and install correctly.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2002
Resolved 9 May 2002
Lifesaving › Buoyant Apparatus
Issued 25 April 2002
Resolved
Provide new pendants for buoyant appartus.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2002
Resolved 9 May 2002
Fire Fighting › Structural - B Class Divisions
Issued 25 April 2002
Resolved
Provide bracket for B1 extingusiher.
Condition: Unknown
Due 10 May 2002
Resolved 9 May 2002
Fire Fighting › Structural - B Class Divisions
Issued 25 April 2002
Resolved
Provide tamper resistent seal on B2 extingusiher.
Condition: Unknown
Due 10 May 2002
Resolved 9 May 2002
Lifesaving › Buoyant Apparatus
Issued 25 April 2002
Resolved
Provide water light for buoyant apparatus.
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Due 10 May 2002
Resolved 9 May 2002
Documentation › Logs/Records › Drug Test Records
Issued 25 April 2002
Resolved
Provide drug test data for the past 12 months.
Condition: Unknown
Due 10 May 2002
Resolved 9 May 2002
Fire Fighting
Issued 1 April 2001
Resolved
SERVICE FIXED CO2 SYSTEM.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Fire Fighting
Issued 1 April 2001
Resolved
PROVIDE FIRE PROTECTION EQUIPMENT MONTHLY EXAM RECORDS.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Fire Fighting
Issued 1 April 2001
Resolved
POST INSTRUCTION PLACARD FOR CO2 SYSTEM.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Engineering
Issued 1 April 2001
Resolved
RENEW OR FREE UP STIFF STBD THROTLE CABLE.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Fire Fighting
Issued 1 April 2001
Resolved
REPAIR & PROVE OPERATION OF THE FIRE DETECTION SYSTEM.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Lifesaving
Issued 1 April 2001
Resolved
PROVIDE CREW TRAINING RECORD.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Lifesaving
Issued 1 April 2001
Resolved
PROVIDE SUPERVISOR TRAINING RECORDS FOR EAP / DRUG & ALCOHOL SCREENING PROGRAM.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Lifesaving
Issued 1 April 2001
Resolved
TRIM BOLT SMOOTH WHERE PROTRUDING INTO LIFEPRESERVER STORAGE SPACE.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Lifesaving
Issued 1 April 2001
Resolved
RENEW OUTDATED EPIRB HYDROSTSTIC RELEASE.
Condition: Unknown
Due 14 June 2001
Resolved 14 June 2001
Navigation
Issued 13 May 1999
Resolved
PROVIDE A BELL.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Electrical
Issued 13 May 1999
Resolved
SECURE WIRING ON CABIN OVERHEAD.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Accommodation/Occupational Safety
Issued 13 May 1999
Resolved
COMPLETE INSTALLATION OF RAILINGS.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Navigation
Issued 13 May 1999
Resolved
PROVE OPERATION OF ELECTRONIC EQUIPMENT AND RADIO.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Unknown
Issued 13 May 1999
Resolved
INSTALL ALL INSTRUCTIONS AND PLACARDS.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Lifesaving
Issued 13 May 1999
Resolved
PROVIDE A LANYARD & CLIP FOR THE RINGBUOY WATERLIGHT.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Fire Fighting
Issued 13 May 1999
Resolved
HYDRO TEST THE CO2 BII.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Accommodation/Occupational Safety
Issued 13 May 1999
Resolved
COMPLETE PIPING FOR HEAD.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Engineering
Issued 13 May 1999
Resolved
COMPLETE INSTALLATION & CLOSURE OF DASH/ CONTROL CONSOLE IN WHEELHOUSE.
Condition: Unknown
Due 20 January 2000
Resolved 20 January 2000
Fire Fighting
Issued 29 April 1999
Resolved
CONDUCT AN INSTALLATION INSPECTION AND PRESSURE TESTS AS REQUIRED FOR NEW CO2 SYSTEM/FIRE DETECTION SYSTEM.
Condition: Unknown
Due 29 April 1999
Resolved 29 April 1999
Electrical
Issued 29 April 1997
Resolved
PROVIDE A SECOND PORTABLE EMERGENCY LIGHT.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Lifesaving
Issued 29 April 1997
Resolved
PROVIDE INSTRUCTIONS FOR HORSE COLLAR SHAPED PFD.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Construction/Loadline
Issued 29 April 1997
Resolved
FINISH INSTALLATION OF HIGH WATER BILGE ALARMS IN ALL COMPARTMENTS.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Lifesaving
Issued 29 April 1997
Resolved
PROVIDE REFLECTOR TAPE AND A 6' LINE W/ A SNAP RING FOR THE RING BUOY.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Lifesaving
Issued 29 April 1997
Resolved
PAINT DISTRESS SIGNAL BOX A BRIGHT COLOR.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Electrical
Issued 29 April 1997
Resolved
RENEW BATTERY BOX IN FOREPEAK.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Construction/Loadline
Issued 29 April 1997
Resolved
DOUBLE CLAMP ALL THRU HULL HOSE CONNECTIONS.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Lifesaving
Issued 29 April 1997
Resolved
RENEW PENDANTS ON BUOANT APPARATUS.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Lifesaving
Issued 29 April 1997
Resolved
REPLACE MISSING REFLECTOR TAPE ON 1 CHILD PFD.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Lifesaving
Issued 29 April 1997
Resolved
PROVIDE 4 ADULT PFDS. TOTAL PERSONS REDUCED TO 48 UNTIL THIS REQ IS COMPLETED.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Construction/Loadline
Issued 29 April 1997
Resolved
REINSTALL SECURING CHAINS/ CABLES ON ALL DECK HATCHES.
Condition: Unknown
Due 10 July 1997
Resolved 10 July 1997
Lifesaving
Issued 10 May 1996
Resolved
PROVIDE A BRIGHT COLOR AND MARKINGS "DISTRESS SIGNALS" ON THE WATERTIGHT_x001C_ BOX FOR THE FLARES.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Construction/Loadline
Issued 10 May 1996
Resolved
REPLACE BROKEN DOG ON AFT HATCH.
Condition: Unknown
Due 10 May 1996
Resolved 10 May 1996
Lifesaving
Issued 14 May 1990
Resolved
RENEWED 1 PFD CHILD SIZE.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Construction/Loadline
Issued 14 May 1990
Resolved
RENEW PLASTIC THRU HULLS WITH METAL THRU HULLS AND INSTALL SEA VALVES ON DISCHARGE FITTINGS FROM SUBMERSIBLE ELECTRIC BILGE PUMPS.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Fire Fighting
Issued 14 May 1990
Resolved
REFILLED BII CO2 FIRE EXTINGUSHER.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Lifesaving
Issued 14 May 1990
Resolved
RENEWED PENDANTS ON BUOYANT APPARATUS.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Navigation
Issued 11 May 1987
Resolved
PROVIDE NAVIGATION LIGHTS TO CONFORM WITH COLREGS VISIBILITY REQUIREMENTS.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987
Construction/Loadline
Issued 11 May 1987
Resolved
REPLACE SEA VALVE FOR SANITARY SUCTION (3/4" GATE).
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987
Electrical
Issued 11 May 1987
Resolved
REPLACE "SO" WIRING ON BILGE PUMPS WITH WIRING APPROVED FOR USE AS PERMANENTLY INSTALLED WIRING.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987
Electrical
Issued 11 May 1987
Resolved
REPLACE HANDLE ON STARBOARD MAIN BATTERY SHUT OFF SWITCH.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987
Engineering
Issued 11 May 1987
Resolved
PLUG THE FITTING OPEN TO MACHINERY SPACE ON FILL PIPE FOR FUEL TANK.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987
Electrical
Issued 11 May 1987
Resolved
TAPE ALL WIRING SPLICES.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987