← All vessels
ARCH ROWAN
ARCH ROWAN is a 1981 mobile offshore drilling unit. The Coast Guard has recorded 78 inspections since 1981, most recently in December 2007, along with 92 deficiencies and 1 casualty investigation in 2003.
Records from 1981 to 2007. Most recent: inspection, 19 December 2007.
- Built
- 1981
- Last inspected
- 19 December 2007
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 92 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2003
Identity
637892
8750211 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
DELETE123
52695
Flag
MARSHALL ISLANDS
368201000 (licence lapsed)
Maury page id
psix-52695
Inspections, by type
…with no type recorded16
Years with a record
24 calendar years (1981–2007)
The 78 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it6544 - Regulatory (Subpart C or D), Net Ton
6544 - Regulatory (Subpart C or D), Gross Ton
6544 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WNJDMMSI 368201000 · cancelled · compulsorily equipped · granted 14 July 2006, cancelled 22 February 2008
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 78
19 December 2007
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3118289
25 April 2007
Administrative Inspection
Administrative · Activities Europe · Activity 2915209
21 March 2006
MARPOL Annex I Examination · COI Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 2601205
14 December 2005
MARPOL Annex I Examination · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2551477
11 May 2005
MARPOL Annex I Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2355184
22 March 2005
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2310721
30 June 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2116359
22 January 2004
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1990647
26 August 2003
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1881263
26 May 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1818849
27 March 2003
Re-Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1770202
21 February 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1487857
23 September 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1073592
20 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1070469
13 August 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1070204
22 June 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066949
18 April 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 131612
14 April 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061588
16 March 2001
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460498
4 October 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1057204
14 May 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 111920
18 April 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1048682
5 April 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 816418
23 February 2000
Re-Inspection
Physical examination · Activities Europe · Activity 1403059
4 May 1999
Type not recorded
No type recorded · Activities Europe · Activity 642077
5 April 1999
Deficiency Check · COI Inspection
Physical examination · Activities Europe · Activity 1360798
25 February 1999
Deficiency Check
Physical examination · Activities Europe · Activity 802491
28 August 1998
Hull Examination
Physical examination · Activities Europe · Activity 1368841
10 June 1998
Deficiency Check
Physical examination · Activities Europe · Activity 1127686
22 April 1998
Re-Inspection
Physical examination · Activities Europe · Activity 1430539
23 January 1998
Deficiency Check
Physical examination · Activities Europe · Activity 1114660
22 September 1997
Administrative
Administrative · Activities Europe · Activity 776230
18 June 1997
Deficiency Check
Physical examination · Activities Europe · Activity 1428800
28 May 1997
Administrative
Administrative · Activities Europe · Activity 1109103
7 May 1997
COI Inspection
Physical examination · Activities Europe · Activity 1455497
11 February 1997
Administrative
Administrative · Activities Europe · Activity 1103812
28 January 1997
Type not recorded
No type recorded · Activities Europe · Activity 1102817
22 January 1997
Administrative
Administrative · Activities Europe · Activity 1104667
21 November 1996
Administrative
Administrative · Activities Europe · Activity 868515
26 July 1996
Deficiency Check
Physical examination · Activities Europe · Activity 1090680
24 May 1996
Deficiency Check
Physical examination · Activities Europe · Activity 1086228
12 March 1996
Deficiency Check
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 885677
1 March 1996
Hull Examination · Re-Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 885419
10 May 1995
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 875962
27 March 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 829386
14 April 1994
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1168796
14 April 1994
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1170106
15 November 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1152493
23 August 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1142712
16 July 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1152784
21 May 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158523
16 April 1993
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 840960
28 October 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 956806
14 September 1992
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955065
3 June 1992
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 946824
12 December 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 954359
13 September 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249944
28 August 1991
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 935454
13 June 1991
Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247666
2 April 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 924921
26 March 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236251
4 December 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1221655
13 June 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 914545
7 June 1989
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 920029
7 June 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1214417
2 June 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 915926
16 September 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1042816
21 July 1988
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1035854
20 November 1987
Hull Examination · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1027512
22 October 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1019644
19 August 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030798
13 July 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327617
4 June 1987
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1030312
4 June 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336773
4 February 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1315738
18 May 1986
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1295493
23 May 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1331693
4 August 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272787
Deficiency record · 92
Fire Fighting › Fire Hoses › Condition
Issued 21 March 2006
Resolved
Conduct Hydro test of all onboard fire hoses. Report cleared via E-mail 25 April 2006, Item remains open until cleared by attending Marine Inspector.
Engineering › Generator (propulsion/auxiliary-electric) › Breaker Circuitry
Issued 21 March 2006
Resolved
Supply proof of proper operation of the Emergency lighting on the Emergency Generator power bus. Report cleared via E-mail 25 April 2006, Item remains open until cleared by attending Marine Inspector.
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 21 March 2006
Resolved
Supply proof of the renewed Hospital space meets the requirement of 108.209. Report cleared via E-mail 25 April 2006, Item remains open until cleared by attending Marine Inspector.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Communications
Issued 21 March 2006
Resolved
Update the fuel transfer procedure to cover the new port bunkering station. Report cleared via E-mail 25 April 2006, Item remains open until cleared by attending Marine Inspector.
Operations/Management › Drills/Instruction › Fire
Issued 21 March 2006
Resolved
Conduct Emergency drills as required by 109.213 Report cleared via E-mail 25 April 2006, Item remains open until cleared by attending Marine Inspector
Deck/Cargo › Ballast › Valves
Issued 6 January 2006
Resolved
Prove the appropriate manufacture of preload tank dump valves marked class 125. Valves must meet nodular iron standard rather than cast iron standard as per ABS rules.
Deck/Cargo › Holds/Tanks › Independent Tank
Issued 14 December 2005
Resolved
Complete ISE via USCG marine inspector on the following spaces
1) All 11 drill water tanks
2) All pre load tanks
Construction/Loadline › Hull
Issued 26 August 2003
Resolved
SEILODD phase II required to be completed at time of next rig movement.
Fire Fighting › Fire Pumps
Issued 8 April 2003
Resolved
Repair and prove proper operation of the #1 main fire pump.
Engineering › Pressure Vessel
Issued 8 April 2003
Resolved
Provide test certificates or make relief valves for P-tanks available for pressure testing. LEGACY COMPONENT DESC: Relief Valve
Fire Fighting › Fire Pumps
Issued 27 March 2003
Resolved
Remount/repair pressure switch for #2 fire pump.
Engineering › Bilge Water Management System › Valve
Issued 27 March 2003
Resolved
Free up and prove proper operation of bilge pit valves in stbd pit.
Engineering › Fuel Oil Service System
Issued 27 March 2003
Resolved
Repair leak on sight glass on fuel oil purifier.
Engineering › Fuel Oil Service System
Issued 27 March 2003
Resolved
Remove fuel in containment under fuel oil transfer pumps.
Fire Fighting › Fire Main › Valves
Issued 27 March 2003
Resolved
Free up fire pump isolation valves for the #1 fire pump.
Fire Fighting › Fire Pumps
Issued 27 March 2003
Resolved
Prove proper operation of the #1 and #2 fire pump relief valves.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 27 March 2003
Resolved
Provide closing device for diesel fuel sounding tube #5.
Accommodation/Occupational Safety › Ventilation
Issued 27 March 2003
Resolved
Adjust ventilation in mud pit room for negative ventilation.
Accommodation/Occupational Safety › Occupational Safety
Issued 27 March 2003
Resolved
Adjust self closing doors to mud pits. (port and stbd)
Fire Fighting › International Shore Connection › Connection
Issued 27 March 2003
Resolved
Free up isolation valve and provide bolts and gasket for international shore connection.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 27 March 2003
Resolved
Provide suitable closure devices for qtrs ventilators on deck.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 27 March 2003
Resolved
Prove proper operation of ventilation shutdown and closure device for port main ventilator.
Lifesaving › Lifeboat
Issued 27 March 2003
Resolved
Operate port and stbd lifeboats in water.
Electrical › Electric Generation Source (emergency)
Issued 27 March 2003
Resolved
Provide results for emergency battery load test (2hr load test)
Operations/Management › Drills/Instruction
Issued 27 March 2003
Resolved
Conduct and log line throwing appliance training.
Fire Fighting
Issued 27 March 2003
Resolved
Provide approved fire control plans onboard.
Fire Fighting › Portable Foam Applicators
Issued 27 March 2003
Resolved
Renew eductor pick up tube for helo deck foam system.
Lifesaving › Lifeboat Equipment › First Aid Kit
Issued 27 March 2003
Resolved
Provide updated first aid kits for port and stbd life capsules.
Accommodation/Occupational Safety › Occupational Safety
Issued 27 March 2003
Resolved
Repair "H" column ladder.
Lifesaving › Lifejacket/PFD (General)
Issued 27 March 2003
Resolved
Provide lifejackets on the drill floor. LEGACY COMPONENT DESC: Storage
Fire Fighting › Self-contained Breathing Apparatus
Issued 27 March 2003
Resolved
Renew wasted flexible air hoses on 3 of 4 SCBA's, and renew broken face mask strap on 4th. LEGACY COMPONENT DESC: Hose
Fire Fighting › Structural - A Class Divisions › Doors
Issued 27 March 2003
Resolved
Adjust door for paint locker to allow proper operation.
Lifesaving
Issued 27 March 2003
Resolved
.....
Engineering › Fuel Oil Storage/Transfer System
Issued 21 February 2002
Resolved
Repair / replace fuel oil leak to valve on emergency generator fuel oil day tank. LEGACY COMPONENT DESC: Valve
Lifesaving › Lifeboat
Issued 21 February 2002
Resolved
Provide a report of survey for condition of port lifeboat hull by a certified lifeboat repair facility due to numberous blisters. LEGACY COMPONENT DESC: Hull
Unknown
Issued 16 March 2001
Resolved
COMPLETE ATTACHED WORK LIST.
Construction/Loadline
Issued 16 March 2001
Resolved
FREE UP AND LUBRICATE ALL PRELOAD DUMP CHECK VALVES WHERE SEIZED. CROP AND RENEW WASTED ELECTRICAL STUFFING TUBES ALONG AFTER SIDE OF HOUSE.
Documentation
Issued 16 March 2001
Resolved
SUBMIT OPERATIONS MANUAL AND STABILITY LETTER TO THE [name withheld] FOR APPROVAL. SUBMIT FIRE CONTROL AND SAFETY PLANS TO [name withheld] FOR APPROVAL; PLANS SHALL REFLECT IMO SYMBOLOGY. ALL LIFE SAVING APPLIANCES SHALL BE PLACARDED WITH IMO SYMBOLOGY.
Fire Fighting
Issued 16 March 2001
Resolved
MAKE ALL INTERIOR FIRE DOORS SELF CLOSING AND LATCHING WITH NO HOLD BACK DEVICES.
Construction/Loadline
Issued 16 March 2001
Resolved
COMPLETE LEG TO CAN NDE, COMPLETE UNDER-WATER EXAM, PROVIDE COPY OF ALL REPORTS AND DIVER'S VIDEO TO THE [name withheld].
Fire Fighting
Issued 16 March 2001
Resolved
CROP AND RENEW WASTED SECTIONS OF FIREMAIN AT GALLEY AND BOTH HELO-DECK FIRE HOSE STATIONS.
Construction/Loadline
Issued 16 March 2001
Resolved
COMPLETE ABS SPECIAL SURVEY, PROVIDE COPY OF GAUGING REPORT AND ABS FINAL REPORT TO [name withheld].
Lifesaving
Issued 23 February 2000
Resolved
Prove proper operation of H2S alarm system.
Fire Fighting
Issued 23 February 2000
Resolved
Provide foam analysis report for semi portable unit.
Lifesaving
Issued 23 February 2000
Resolved
Repair damaged fiberglass hull, lifeboat/capsule no. 3.
Fire Fighting
Issued 23 February 2000
Resolved
Repair/replace damaged blatter to heli deck foam tank. Vsl not to conduct helo ops until satisfactory repairs/testing completed.
Lifesaving
Issued 5 April 1999
Resolved
OPERATE LIFECAPSULES IN THE WATER ON A QUARTERLY BASIS. 46CFR109.213(d)(3)RECORD DRILLS IN THE SHIP'S OFFICIAL LOG._x001C_
Construction/Loadline
Issued 28 August 1998
Resolved
Conduct underwater examination to spudcans (NDT all spud can critical areas, top and bottom) at next rig move. NDT waisted side longs in #4 & 8 preloads. Obtain sample thickness gaugings of all preload bottom plating. Renew bilge line in way of doubler in #13 void.
Documentation
Issued 28 August 1998
Resolved
Conduct deadweight or incline survey. _x001C_ - Information has been submitted to G-MSC for the third and final time._x001C_ - Rowan has agreed that they will comply with the findings from G-MSC as per this submittal. If deadwt survey required will submit procedure ASAP.
Documentation
Issued 10 June 1998
Resolved
Conduct DEADWEIGHT SURVEY or INCLINE as per USCG Marine Safety Center letter dated 02JAN97 and 01JUN98 at next rig move.
Lifesaving
Issued 7 May 1997
Resolved
All lifeboat and liferaft falls are due for renewal. Issued rerquirement torenew and conduct weight tests in the presence of a marine inspector.
Lifesaving
Issued 7 May 1997
Resolved
Air bottle #4 in lifeboat #2 empty (leaking valve). Issued requirement to renew same.
Fire Fighting
Issued 7 May 1997
Resolved
Provide twelve 15 pound CO2 fire extinguishers fit for service in accordance with 46 CFR 107.
Unknown
Issued 28 January 1997
Resolved
This is an "administrative" CG-835 for the MODU to undergo a Deadweight Survey in accordance with G-MSC-1 letter H1-9700002, dated 02JAN97, to Letourneau Inc., no later than 10MAY97.
Lifesaving
Issued 1 March 1996
Resolved
REPLACE AND REFURBISH THE LIFERINGS IDENTIFIED AS DEFICIENT DURING THE MID-PERIOD INSPECTION.
Accommodation/Occupational Safety
Issued 1 March 1996
Resolved
REPLACE THE WIRE JUNCTION/SWITCH BOXES INSIDE BOTH "TIOGA" HEATER UNITS.
Accommodation/Occupational Safety
Issued 1 March 1996
Resolved
REMOVE THE WASTED UTILITY BOXES AND WATER RESEVOIRS (OUT OF SERVICE) IN BOTH "TIOGA" HEATER UNITS.
Accommodation/Occupational Safety
Issued 1 March 1996
Resolved
PROVIDE A MEANS TO SECURE THE DOOR ON THE STARBOARD "TIOGA" HEATER UNIT.
Accommodation/Occupational Safety
Issued 1 March 1996
Resolved
RENEW/REFURBISH THE SIDING ON THE STARBOARD "TIOGA" HEATER UNIT WHERE IT ISWASTED THROUGH TO THE INSULATION.
Engineering
Issued 1 March 1996
Resolved
PROVE PROPER OPERATION OF THE LOW LUBE OIL PRESSURE SHUTDOWN/ALARM ON #3 GENERATOR.
Accommodation/Occupational Safety
Issued 1 March 1996
Resolved
RENEW/REFURBISH THE FAN HOUSING ON THE STARBOARD "TIOGA" HEATER UNIT.
Accommodation/Occupational Safety
Issued 1 March 1996
Resolved
REPLACE THE MOTOR MOUNTING PLATES FOR THE BLOWERS ON BOTH "TIOGA" HEATING UNITS.
Lifesaving
Issued 10 May 1995
Resolved
RENEW FORWARD LIMIT SWITCH TO #2 STBD LIFE CAPSULE.
Lifesaving
Issued 10 May 1995
Resolved
PROVIDE MIO NEW YORK WITH STATEMENT OF RELEASING GEAR PERFORMANCE TO ALL LIFE CAPSULS WHEN SEA STATE PERMITS, BUT NO LATER THAN 10JUN95.
Fire Fighting
Issued 13 June 1991
Resolved
PROVIDE [name withheld] WITH COPY OF FIRE CONTROL PLAN APPROVAL DATE AND PORTOF APPROVAL.
Construction/Loadline
Issued 13 June 1991
Resolved
RENEW IN LIKE AND QUALITY AS ORIGINAL APPROX 750 FT OF LADDER TO PORT,STBD AND BOW LEGS TO CANS. (PORT -240, STBD -280, BOW -230)
Construction/Loadline
Issued 13 June 1991
Resolved
PROVIDE [name withheld] WITH COPY OF MAGNETIC PARTICLE INSPECTION SURVEY OF PORT SPUD CAN JUNE 91 DRYDOCK._x001C_ _x001C_ ATTN: D. MIDGETTE
Deck/Cargo
Issued 13 June 1991
Resolved
PERMANENTLY INSTALL VISUAL ALARM IN PUMP ROOM FOR LOSS OF PURGE.
Fire Fighting
Issued 13 June 1991
Resolved
PROVIDE HYDROSTATIC TESTING AND CERTIFICATES OF INSPECTION FOR 7-BII PORTABLE FIRE EXTINGUISHERS FROM A D.O.T. APPROVED FACILITY.
Construction/Loadline
Issued 13 June 1991
Resolved
CROP OUT AND RENEW IN LIKE KIND AND QUALITY EXISITING 28 WINDOWS APPROX 3FTFOR CONTROL ROOM TOWER.
Fire Fighting
Issued 13 June 1991
Resolved
PROVIDE [name withheld] WITH ABS APPROVED PLANS AND DRAWINGS OF RAW WATER TOWER BEING INSTALLED IN PORT LEG/SPUD CAN DRYDOCK JUNE 91. _x001C_ _x001C_ ATTN: D. MIDGETTE
Construction/Loadline
Issued 13 June 1991
Resolved
PROVIDE [name withheld], WITH COPY OF ULTRASONIC TESTING OF RAW WATER TOWER CONDUCTED BY [name withheld], ROWAN COMPANIES INC. _x001C_ _x001C_ ATTN: D MIDGETTE
Fire Fighting
Issued 13 June 1991
Resolved
PROVIDE COMPLETE SERVICE OF ALL FIRE EXTINGUISHER AND FIRE PROTECTION SYSTEM EQUIPMENT AS PER WOOD GROUP FIRE PROTECTION, LTD REPORT DATED MAY 91.
Lifesaving
Issued 13 June 1990
Resolved
PROVIDE PROOF OF SERVICING OF HYDROSTATIC RELEASING UNITS AT A USCG APPROVED TESTING FACILITY. SEA DOG LSA (SCOTLAND) LTD IS NOT APPROVED FOR THE TESTING OF THESE ITEMS.
Construction/Loadline
Issued 2 June 1989
Resolved
NOTED 6" FRACTURE STARBOARD CAN AND 5" FRACTURE BOW CAN IN WAY OF VERTICAL TUBULAR STIFFENERS, LOWER WELDS. GROUND TO GOOD METAL, WELDED AND NOT SATISFACTORY.
Fire Fighting
Issued 21 July 1988
Resolved
CONDUCT HYDRO TEST ON ALL S.C.B.A. BOTTLES INLCUDING SPARES ONBOARD.
Fire Fighting
Issued 4 June 1987
Resolved
REPLACE GENERAL ALARM BELL LOCATED ON THE AFT END OF THE HOUSE NEXT TO THE PIPE RACK WITH A PROPER UNIT.
Electrical
Issued 4 June 1987
Resolved
PROPERLY SIZE AND INSTALL EXHAUST AND SUPPYL AIR FANS IN THE MUD PIT ROOM AND MUD PUMP ROOM SO THAT A POSITIVE PRESSURE IS MAINTAINED BETWEEN THESE ROOMS AND QUANTITATIVELY PROVE THE POSITIVE PRESSURE DIFFERENTIAL IS MAINTAINED.
Lifesaving
Issued 4 June 1987
Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE SURVIVAL CAPSULES: (PORT) LIGHT ANDWHISTLES FOR PFDS, PRESSURE GAUGE FOR BREATHING AIR, RECHARGE FIRE EXTIN- GUISHERS; (STARBOARD) ONE BOATHOOK, PRESSURE GAUGE FOR BREATHING AIR AND TWO LIGHTS FOR PFDS.
Lifesaving
Issued 4 June 1987
Resolved
REPLACE IN KIND THE 20 MAN DAVIT LAUNCH LIFERAFT WHICH WAS LOST DURING HEAVY WEATHER.
Lifesaving
Issued 4 June 1987
Resolved
PROVIDE THE REQUIRED 1500' OF AUX. LINE FOR THE LINE THROWING APPLICANCE.
Lifesaving
Issued 4 June 1987
Resolved
REPAIR THE PORT CAPSULE EMERGENCY RADIO.
Fire Fighting
Issued 4 June 1987
Resolved
PROVIDE A COPY OF THE ANNUAL FOAM ANALYSIS REPORT TO THE USCG.
Fire Fighting
Issued 4 June 1987
Resolved
REMOVE FROM THE MODU OR REPAIR THE 50 LB CO2 FIRE EXTINGUISHER LOCATED ON THE HELO DECK.
Fire Fighting
Issued 4 June 1987
Resolved
PROVIDE PROPER CALIBRATION TEST GAS FOR THE CGI/O2 MONITOR, SAMPLING HOSES FOR EACH MONITOR, AND PROVE PROPER OPERATION.
Fire Fighting
Issued 4 June 1987
Resolved
PROPERLY INSTALL 20 SEC. TIME DELAY ALARM AND VENTILATION SHUTDOWN FOR THE HALON SYSTEM LOCATED IN THE PILOT HOUSE OR REMOVE SYSTEM. USCG PLAN APPROVAL IS REQUIRED.
Fire Fighting
Issued 4 June 1987
Resolved
RECHARGE HALON CYLINDER #73581E5 LOCATED IN THE MOTOR ROOM CYLINDER BANK ORREPLACE CYL WITH A FULLY CHARGED UNIT.
Electrical
Issued 4 June 1987
Resolved
REPLACE THE THREE ELECTRIC MOTORS CLASSED AS CLASS 1 GROUP D WHICH DRIVE THE HYDRAULIC PUMPS IN THE SHALE SHAKER AREA (CLASS 1 DIVISION1) WITH UNITS WHICH ARE RATED FOR CLASS 1 GROUP C AND D LOCATIONS.
Electrical
Issued 4 June 1987
Resolved
PROVE PROPER OPERATION OF THE LOSS OF VENTILATION ALARM FOR THE SUPPLY AIR FAN MUD PUMP ROOM AND THE VENTILATION ALARM FOR THE FANS LOCATED IN THE MUD PIT ROOM.
Lifesaving
Issued 18 May 1986
Resolved
REPAIR DAMAGE TO HULL ON STERN OF PORT BOAT.
Lifesaving
Issued 18 May 1986
Resolved
GET 4TH DAVIT LAUNCHED LIFERAFT RETURNED TO VESSEL WITH UP TO DATE SERVICING. FORWARD COPY OF SERVICING REPORT TO [name withheld].
Lifesaving
Issued 18 May 1986
Resolved
OBTAIN 12 U.S. COAST GUARD APPROVED PARACHUTE FLARES AND LOCATE SAME IN RADIO ROOM.
Casualty record · 1
26 May 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1818849
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.