Inspection history · 190
1 October 2019
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6825709
21 June 2019
Bulk Liquid Transfer Monitor
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6723856
15 March 2019
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6644346
17 January 2019
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6613520
14 May 2018
Administrative Inspection · Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6414044
4 April 2018
Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6387791
14 August 2017
Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6240821
24 January 2017
COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6073408
4 April 2016
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5846891
11 March 2016
Administrative Inspection · MTSA Verification · Annual Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5831623
3 February 2016
Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5808602
29 January 2016
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5806067
29 January 2016
Permit to Proceed
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5807172
26 January 2016
Damage Survey
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5804408
26 January 2016
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5818839
1 July 2015
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5169690
2 June 2015
Periodic Inspection · MTSA Verification
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5137442
15 April 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5103697
10 April 2015
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5100748
23 February 2015
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5073600
14 August 2014
Hull Examination · Internal Structural Exam · Administrative Inspection · Cargo Tank Internal
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4954564
23 May 2014
DAPI Audit · Annual Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4871398
13 July 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4652089
24 June 2013
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4629963
24 June 2013
Deficiency Check · Damage Survey
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4630534
18 June 2013
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4631596
29 October 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4474417
12 July 2012
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4378529
19 March 2012
Ballast Water Examination · MTSA Verification · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4263417
19 October 2011
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4219160
18 August 2011
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4124150
21 July 2011
Administrative Inspection · Drydock Exam · Internal Structural Exam · Cargo Tank Internal · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4105713
13 July 2011
MTSA/ISPS Verification · Annual Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4080368
20 October 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3873925
29 July 2010
Damage Survey · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3810151
28 July 2010
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3809431
9 June 2010
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3756890
28 April 2010
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3764061
14 September 2009
Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3593814
30 June 2009
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3519126
27 April 2009
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3477861
10 April 2009
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3450083
6 April 2009
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3447339
2 April 2009
Periodic Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3447047
23 July 2008
Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3276769
8 July 2008
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3261661
21 June 2008
Damage Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3243145
20 June 2008
Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3242756
12 June 2008
Annual Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3234643
24 March 2008
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3172784
26 February 2008
Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3154036
3 November 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3092385
21 October 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3083958
8 October 2007
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3085164
21 July 2007
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3002562
14 February 2006
Construction Oversight · Cargo Tank Internal · MTSA/ISPS Verification · COI Inspection · Ballast Water Examination · Internal Structural Exam · MARPOL Annex I Examination · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2705494
4 January 2006
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2561268
16 December 2005
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2552241
5 December 2005
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2545950
21 September 2005
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2497701
21 June 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2397922
14 June 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2390219
11 January 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2272974
30 December 2004
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2268180
27 October 2004
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2229555
23 October 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2430644
28 September 2004
Type not recorded
No type recorded · USCG Heartland District (dpb) · USCG Heartland District (CGD-H) · Activity 2207711
22 June 2004
MTSA Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2114623
15 June 2004
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2100397
15 March 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2024565
21 February 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2021113
20 August 2003
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1995261
1 April 2003
Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1766961
14 February 2003
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1740937
1 November 2002
Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1699388
28 January 2002
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1481799
13 July 2001
COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1366478
26 January 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1448227
15 November 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1055819
25 October 2000
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1057258
3 October 2000
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 822849
3 October 2000
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 822851
21 September 2000
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1053669
11 September 2000
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1429415
12 June 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 463860
4 May 2000
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1049844
13 March 2000
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 823063
13 March 2000
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1047421
9 March 2000
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1047000
25 August 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1464216
10 August 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 533877
14 July 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 430704
30 June 1999
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1082471
10 May 1999
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1388802
29 October 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 803593
9 June 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 456521
28 March 1998
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1375327
17 January 1998
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 540471
14 November 1997
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1386124
28 July 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 37642
18 July 1997
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 502616
3 May 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 498138
3 February 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 764185
10 January 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 197649
10 January 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 489749
19 October 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1093269
18 October 1996
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1093799
8 October 1996
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1183518
6 April 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 474930
28 January 1996
Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1435723
23 January 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 758857
21 January 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 197592
21 January 1996
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1360384
7 October 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 513305
28 September 1995
Re-Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 874371
21 June 1995
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1191841
10 June 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 513833
9 March 1995
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 529072
19 October 1994
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1180768
1 September 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 476640
10 February 1994
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1163804
8 February 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 507865
8 February 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 666985
7 February 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1358291
27 January 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 3853
27 January 1994
Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 50658
27 January 1994
Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1358289
7 January 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 856520
3 January 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 666986
2 January 1994
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 85943
2 January 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1456140
27 December 1993
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 849182
20 September 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 476958
30 March 1993
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1145698
5 March 1993
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1142902
21 February 1993
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 461450
12 November 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1134695
28 October 1992
Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 958831
24 October 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 962563
19 October 1992
COI Inspection · MARPOL Annex II Examination · MARPOL Annex V Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1247071
23 May 1992
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 471151
16 February 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1269367
14 February 1992
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 947824
3 February 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 944231
23 August 1991
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 515002
6 June 1991
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 442770
30 October 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 528111
29 October 1990
Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 909683
29 October 1990
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1270582
27 July 1990
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1215520
18 July 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1230413
1 June 1990
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1231018
25 May 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 484703
1 April 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 455811
22 February 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 926952
2 February 1990
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 510782
22 November 1989
Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236109
15 November 1989
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 917977
14 November 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 908987
7 November 1989
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1332517
21 September 1989
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1002366
16 December 1988
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1340375
13 October 1988
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 887566
22 July 1988
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1346214
23 May 1988
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 887041
17 May 1988
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 441041
23 September 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1320990
12 August 1987
Drydock Extension
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1336863
27 June 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1330968
8 April 1987
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 523062
8 April 1987
MARPOL Annex II Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1020644
4 December 1986
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 477326
6 October 1986
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1016528
21 September 1986
Deficiency Check
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1318815
15 September 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1007861
15 September 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324662
9 September 1986
Re-Inspection
Physical examination · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1010255
26 February 1986
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1298447
25 January 1986
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1303907
5 January 1986
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 997322
19 December 1985
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 993950
23 September 1985
Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1298398
11 July 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 983077
7 February 1985
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 467560
16 January 1985
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1286587
8 August 1984
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1281092
18 July 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 966932
18 July 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971932
18 July 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 972834
24 July 1981
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1274615
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 4 April 2018
Resolved
Cargo Tanks carrying Grade A-C cargoes are requried to be fitted with a pressure/vacuum relief valve. Residue tanks on deck are fitted with gooseneck vents. Install P/V valve on both residue tanks.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2018
Resolved 15 May 2018
Resolution: Vessel installed proper P/V valves.
Deck/Cargo › Holds/Tanks › Liquid Level Gaging
Issued 4 April 2018
Resolved
Tanks shall be fitted with approved liquid level gaging system. Residue tanks utilize sounding tube/stick gaging. Install gaging system with 46 CFR 39.2003.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 May 2018
Resolved 17 May 2018
Resolution: Guaging system installed on residue tank.
Construction/Loadline › Structures › Manhole
Issued 15 March 2016
Resolved
Repair dog on forepeak hatch, dog bent excessivley.
Condition: Damaged By Earlier Event
Due 14 April 2016
Resolved 4 April 2016
Resolution: Forepeak hatch dog repaired to the satisfaction of the attending marine inspector.
Electrical › Lighting (service) › Conductor
Issued 15 March 2016
Resolved
Replace electrical cable on deck light located a 6p ballast tank and in between 5p nad 4p ballast vent.
Condition: Improper/Lack of Maintenance
Due 14 April 2016
Resolved 4 April 2016
Resolution: Electrical cable replaced to the satisfaction of the attending marine inspector.
Engineering › Lubricating Oil Service System › Gauge
Issued 15 March 2016
Resolved
Replace oil pressure gauge on #2 starboard prime mover.
Condition: Improper/Lack of Maintenance
Due 14 April 2016
Resolved 15 March 2016
Resolution: Replaced gauge with new.
Construction/Loadline › Hull › Bottom Plating
Issued 3 February 2016
Resolved
Provide written proposal with drawings for the repair of damage.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 4 February 2016
Resolved 11 February 2016
Resolution: Repair plan received.
Construction/Loadline › Hull › Bottom Plating
Issued 29 January 2016
Resolved
Damage to bottom plating and frames in port #1 ballast tank along with frame damage and damage to bottom plating in forward peak void along with side shell damage approx 30'x 6'
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 24 February 2016
Resolution: All repairs completed to the satisfaction of the attending MI.
Construction/Loadline › Hull › Hull Plating
Issued 26 January 2016
Resolved
fractures in the #1 port ballast tank and the forward ballast tank
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 19 February 2016
Resolved 29 January 2016
Resolution: no temp repair made vsl issued ptp
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 23 February 2015
Resolved
Inert Gas System (IGS) not operating as designed. Provide proof of proper operation to the satisfaction of Class and the Coast Guard.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 February 2015
Resolved 23 February 2015
Resolution: Operator proved proper operation of the IGS to the attending MIs.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 23 May 2014
Resolved
Provide operational emergency cargo pump shutdown (#1) to the satisfaction of the CG Marine Inspector IAW 46 CFR 32.50-35.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2014
Resolution: Repaired.
Electrical › Electric Generation Source (service) › Generator
Issued 13 July 2011
Resolved
# 4 gen set is in need of repair, Vessel rep sates that Gen set Knocks when prime mover is runng
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 13 September 2011
Resolved 26 August 2011
Resolution: Radiator replaced with new in kind. Issue was pin hole in old radiator.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 13 July 2011
Resolved
# 1 cargo prime mover is in need of repair
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2011
Resolved 26 August 2011
Resolution: PTO clutch bearings replace, OP test SAT.
Electrical › Lighting (service) › Outlet Box
Issued 13 July 2011
Resolved
Secure light fixture in overhead above entrance door, lose wires and cover missing in hyd room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2011
Resolved 18 August 2011
Deck/Cargo › Inert Gas System › Boiler Uptake Valve
Issued 29 July 2010
Resolved
Repair/replace atmosphere valve to working condition. Provide tech report to Coast Guard Marine Inspector.
Action required: 705 - Other - as specified
Resolved 18 August 2010
Resolution: Received tech report from Instrumetns & Controls, Inc indicating the replacement of the valve.
Construction/Loadline › Markings › Summer Load Line
Issued 2 April 2009
Resolved
Verify dead weight tonnage calculation and correct documentation and certificates accordingly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 April 2009
Resolved 7 April 2009
Resolution: Reviewed and corrected by Houston acctivity 3447339
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 12 June 2008
Resolved
Vessel required to install a shower and eyewash station on deck in accordance with 46CFR153.216 and MSC letter dated 27MAY2008.
Action required: 705 - Other - as specified
Due 12 August 2008
Resolved 23 July 2008
Resolution: Item installed.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 12 June 2008
Resolved
Vessel required to identify and repair ground in 480V electrical system.
Action required: 705 - Other - as specified
Due 12 August 2008
Resolved 23 July 2008
Resolution: Item repaired
Construction/Loadline › Hull › Bottom Plating
Issued 2 January 2005
Resolved
Vessel is to comply with ABS Class Survey Rpt # G575233 Dtd 2 Jan 05. Upon arrival at discharge port, notify local OCMI of status. All repairs to be made to the satisfaction of local OCMI.
Action required: 705 - Other - as specified
Resolved 28 March 2007
Resolution: Completed during drydock period for double-hull conversion.
Construction/Loadline › Hull › Bottom Plating
Issued 30 December 2004
Resolved
Proceed to Galveston layberth & make #1 port cargo tank gas free and available for Coast Guard inspector. Barge is to remain at Galveston layberth until released by [name withheld].
Action required: 705 - Other - as specified
Resolved 1 January 2005
Engineering › Fuel Oil Service System › Hose
Issued 27 October 2004
Resolved
Replace deteriorated fuel hoses on the prime mover for the generator and the prime mover for the #2 cargo pump.
Action required: 705 - Other - as specified
Due 27 November 2004
Resolved 24 November 2004
Engineering › Fuel Oil Service System › Filter
Issued 27 October 2004
Resolved
Remove petcocks from the RAYCOR filters on the generator engine and the #2 cargo pump engine and either plug or provide the appropriate type of petcock that allows for plugs.
Action required: 705 - Other - as specified
Due 27 November 2004
Resolved 24 November 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 27 October 2004
Resolved
Install a light cover on the light in the generator room.
Action required: 705 - Other - as specified
Due 27 November 2004
Resolved 24 November 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 October 2004
Resolved
Paint the navigation light screens black.
Action required: 705 - Other - as specified
Due 27 November 2004
Resolved 24 November 2004
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 October 2004
Resolved
Repair the stern light.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 November 2004
Resolved 24 November 2004
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 27 October 2004
Resolved
Test cargo pump gauges in accordance with 33 CFR 156.170.
Action required: 705 - Other - as specified
Due 27 November 2004
Resolved 24 November 2004
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 1 November 2002
Resolved
Make permanent repairs to the port and stbd chain lockers and prove watertight integrity to the attending Marine Inspector iaw ICLL 66 Regs 12-20. Repairs to be completed no later than next drydock, 28 March 2003. LEGACY COMPONENT DESC: Cofferdam
Due 28 March 2003
Resolved 28 March 2007
Resolution: Corrected during drydock period for double-hull conversion.
Engineering › Compressed Air System (start air)
Issued 1 November 2002
Resolved
Provided a properly tagged and tested relief for the vessels air receiver iaw 46 CFR 54.15-10. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Due 1 December 2002
Resolved 18 February 2003
Resolution: MSO Tampa received verifying documentation that the relief valves were tested IAW and found to meet the applicable requirements for the material, including any specification (125 psi).
Unknown
Issued 13 March 2000
Resolved
MAKE PERMANENT REPAIRS TO SERVICE AIR LINE FORWARD OF AUXILIARY HOUSE DURING NEXT DRYDOCK.
Condition: Unknown
Due 13 March 2000
Resolved 13 March 2000
Deck/Cargo
Issued 13 March 2000
Resolved
REPAIR HIGH VELOCITY PV VALVE ON PORT HEADER TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 13 March 2000
Resolved 13 March 2000
Deck/Cargo
Issued 9 March 2000
Resolved
MAKE PERMANENT REPAIRS AS ORIGINAL TO CARGO PIPING PRIOR TO NEXT LOADING.
Condition: Unknown
Due 9 March 2000
Resolved 9 March 2000
Construction/Loadline
Issued 10 May 1999
Resolved
INSTALL HANDRAILS MIDSHIP PORT & STBD. (HANDRAILS MISSING)
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Lifesaving
Issued 10 May 1999
Resolved
PROVIDE VESSEL'S NAME AND RE-RETRO ON TWO (2) RING BUOYS.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Electrical
Issued 10 May 1999
Resolved
INSTALL METAL GUARDS FOR EXPLOSION PROOF LIGHTS IN CARGO PUMP ROOMS, 1,3,& 4. (GUARDS MISSING)
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Electrical
Issued 10 May 1999
Resolved
PERMANENTLY AFFIX ELECTRICAL BOX TO FORWARD MAST.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 10 May 1999
Resolved
EFFECT PERMANENT REPAIRS TO CRACK LOCATED ON FORWARD PEAK HEAD LOG. (CRACK LOCATED APPROX 2' BELOW MAIN DECK, 1/4" X 18" LONG, TEMPORARY PATCH WAS PLACED ON CRACK)
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Construction/Loadline
Issued 10 May 1999
Resolved
EFFECT PERMANENT REPAIRS TO WASTED AREA OF RUB RAIL LOCATED ON PORT SIDE OFFORWARD PEAK/HEAD LOG.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Deck/Cargo
Issued 10 May 1999
Resolved
EFFECT PERMANENT REPAIRS TO HOLE LOCATED UNDER #1 CARGO PUMP ENGINE. (HOLE WAS FOUND LEAKING OIL TO MAIN DECK)
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Deck/Cargo
Issued 28 March 1998
Resolved
PRIOR TO LOADING CARGO PROPERLY STENCIL CARGO PUMP SHUTDOWNS 1-4, VAPOR CONTROL VALVE AND PIPING AND DANGER SIGNS.
Condition: Unknown
Due 4 April 1998
Resolved 1 April 1998
Engineering
Issued 8 October 1996
Resolved
PROVER PROPER OPERATION OF THE OVERSPEED TRIPS AND LOW L/O SHUTDOWNS ON EACH CARGO PUMPS IAW ABS RULES.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Lifesaving
Issued 8 October 1996
Resolved
PROVIDE INFORMATION CONCERNING THE SPARK ARRESTORS FOR ALL OF THE DIESEL GENERATORS AND THE DIESEL AIR COMPRESSORS.
Condition: Unknown
Due 8 October 1996
Resolved 8 October 1996
Accommodation/Occupational Safety
Issued 8 October 1996
Resolved
REPLACE AIR PRESSURE GAUGE ON THE MAIN DECK AIR RECEIVER AND RETEST THE RELIEF VALVE.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Accommodation/Occupational Safety
Issued 8 October 1996
Resolved
PROVE PROPER LIFTING OF THE TWO DECK AIR RECEIVER'S RELIEF VALVES LOCATED IN THE THERMAL FLUID HEATER ROOM.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Accommodation/Occupational Safety
Issued 8 October 1996
Resolved
PROVE PROPER LIFTING OF THE BOILER ROOM'S AIR RECEIVER.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Engineering
Issued 8 October 1996
Resolved
PROVER PROPER OPERATION OF THE 2 THERMAL FLUID HEATERS OR COMPLETELY DISABLE THE FUEL SYSTEMS AND THE AUTOMATION ELECTRICAL PACKAGES.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Electrical
Issued 8 October 1996
Resolved
PROVIDE DI-ELECTRIC MATTING IN WAY OF THE ELECTRICAL SWITCH BOARDS.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Electrical
Issued 8 October 1996
Resolved
PROVE THE PROPER OPERATION OF THE 2 ELECTRICAL DIESEL GENERATOR TRIPS OR COMPLETELY DISABLE THE FUEL SYSTEMS.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Engineering
Issued 8 October 1996
Resolved
PROVIDE RATINGS OF EVERY DIESEL ENGINE.
Condition: Unknown
Due 20 December 1996
Resolved 20 December 1996
Construction/Loadline
Issued 28 January 1996
Resolved
PROVIDE DOCUMENTATION ADDRESSING PROPOSED CORRECTION TO RECURRING_x001C_ FRACTURE IN WAY OF FRAME 55, STARBOARD STERN VOID AT TOW NOTCH.
Condition: Unknown
Due 28 January 1996
Resolved 28 January 1996
Deck/Cargo
Issued 21 January 1996
Resolved
LOAD VESSEL WITHIN LIMITS OF STABILITY BOOK FOR VESSEL. NO PRODUCT TO BE LOADED INTO TANKS #6 P/S UNTIL ITEM 1 ABOVE IS CLEARED.
Condition: Unknown
Due 21 January 1996
Resolved 21 January 1996
Construction/Loadline
Issued 21 January 1996
Resolved
PROVIDE REPAIR PROCEDURE FOR REPAIR OF HOLE IN AFT CARGO TANKS
Condition: Unknown
Due 21 January 1996
Resolved 21 January 1996
Deck/Cargo
Issued 19 October 1994
Resolved
RE-STENCILE "DANGER KEEP OUT" ON EXPANSION TRUNKS.
Condition: Unknown
Due 30 October 1994
Resolved 3 November 1994
Deck/Cargo
Issued 19 October 1994
Resolved
PROVE PROPER OPERATION OF THE #4 CARGO PUMP ENGINE REMOTE SHUTDOWN.
Condition: Unknown
Due 30 October 1994
Resolved 3 November 1994
Deck/Cargo
Issued 19 October 1994
Resolved
REPLACE BROKEN SIGHT GLASS AT #6 STBD CARGO TANK._x001C_
Condition: Unknown
Due 30 October 1994
Resolved 3 November 1994
Electrical
Issued 19 October 1994
Resolved
SECURE ARMORED CABLES OUTBOARD SIDE OF #4 CARGO PUMP HOUSE.
Condition: Unknown
Due 30 October 1994
Resolved 3 November 1994
Deck/Cargo
Issued 27 January 1994
Resolved
VESSEL MAY PROCEED TO MEREAUX, LA VIA SAVANNAH, GA TO LOAD CARGO IN ANY TANK EXCEPT #6P. CONTANT [name withheld] PRIOR TO DEPARTING PORT.
Condition: Unknown
Due 3 February 1994
Resolved 3 February 1994
Deck/Cargo
Issued 27 January 1994
Resolved
IDENTIFY SOURCE OF LEAK AND MAKE REPAIRS TO #6 PORT CARGO TANK TO THE SATISFACTION OF THE COGNIZANT [name withheld] IS PERMITTED IN #6P UNTIL THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 27 January 1994
Resolved 27 January 1994
Deck/Cargo
Issued 2 January 1994
Resolved
Ensure blank flanges installed between sea chest and pump system in #6 portcargo tank are cargo/water tight to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 2 January 1994
Resolved 2 January 1994
Deck/Cargo
Issued 27 December 1993
Resolved
Install shaft guard - #4 cargo pump engine.
Condition: Unknown
Due 27 December 1993
Resolved 27 December 1993
Construction/Loadline
Issued 27 December 1993
Resolved
Repair water tight door - port side compressor room. (dogs)
Condition: Unknown
Due 27 December 1993
Resolved 27 December 1993
Electrical
Issued 27 December 1993
Resolved
Reattach electrical cable in compressor room near switch for stern light.
Condition: Unknown
Due 27 December 1993
Resolved 27 December 1993
Construction/Loadline
Issued 27 December 1993
Resolved
Renew dog for dead cover on port side of compressor room.
Condition: Unknown
Due 27 December 1993
Resolved 27 December 1993
Construction/Loadline
Issued 27 December 1993
Resolved
Repair wtd on aft side of thermal fluid heater room. (dogs)
Condition: Unknown
Due 27 December 1993
Resolved 27 December 1993
Deck/Cargo
Issued 24 October 1992
Resolved
MAKE PERMANENT REPAIRS TO ALL REACH ROD'S AND PACKING GLANDS FOR REACH RODS. VESSEL IS LIMITED TO GRADE E CARGOES, UNTIL COMPLETED. TEMP REPAIRSACCEPTED, FOR GRADE E CARGO ONLY.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Engineering
Issued 24 October 1992
Resolved
IN ORDER TO COMPLY WITH 46 CFR 111.105-31, REMOVE OR MOVE ULLAGE LOCATED WITHIN 10 FEET OF THE ACCESS DOOR TO THE THERMAL FLUID HEATER ROOM. PENDINGCOMPLIANCE, THE ACCESS DOOR SHALL BE DOGGED AND LOCKED.
Condition: Unknown
Due 24 October 1992
Resolved 24 October 1992
Fire Fighting
Issued 19 October 1992
Resolved
POST OPERATING INSTRUCTIONS OUTSIDE THE BOILER ROOM AT THE CONTROL STATION_x001C_FOR THE CO2 SYSTEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Engineering
Issued 19 October 1992
Resolved
PROVIDE A COAST GUARD APPROVED TEST PROCEDURE FOR THE TO THERMAL FLUID HEATERS IN ACCORDANCE WITH 46 CFR 63.01-3 AND 46 CFR 63.10-1.
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Deck/Cargo
Issued 19 October 1992
Resolved
CORRECT OPERATION OF ALL SIEZED UP BLOCK VALVES (CROSS TANK VALVES) IN _x001C_ CARGO TANKS AT NEXT DRYDOCKING OR INTERNAL INSPECTION TO THE SATISFACTION_x001C_ OF THE COGNIZANT OCMI._x001C_ _x001C_
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Engineering
Issued 19 October 1992
Resolved
SHOW PROPER OPERATION OF BOTH THERMAL FLUID HEATERS, ALL SHUTDONWS, ALARMS_x001C_AND SAFETY DEVICES.
Condition: Unknown
Due 9 November 1992
Resolved 9 November 1992
Deck/Cargo
Issued 19 October 1992
Resolved
CORRECT PACKING ON #2 STARB, #3 STARB, #4 PORT, #5 PORT HIGH SUCTION, #6_x001C_ STARB LOW SUCTION AND BLOCK VALVES #34 AND 36 REACH ROD DECK PENETRATIONS_x001C_ IN ACCORDANCE WITH 46 CFR 32.50-15 (b) TO THE SATISFACTION OF THE CONIZANT_x001C_OCMI PRIOR TO LOADING CARGO AT NEXT PORT._x001C_
Condition: Unknown
Due 9 November 1992
Resolved 9 November 1992
Deck/Cargo
Issued 19 October 1992
Resolved
REPLACE RELIEF VALVES ON BOTH DECK MACHINERY AIR COMPRESSOR VOLUME TANKS_x001C_ WHICH USE AIR OVER COMPRESSOR OIL RATED AT 175PSI OR LESS. TANK MAWP 175PSI
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Electrical
Issued 19 October 1992
Resolved
CORRECTLY WIRE AND REINSTALL SWITCHES FOR THE NAVIGATION LIGHT SYSTEMS FORWARD THAT LIE WITHIN 10FT OF CARGO TANK VENTS AND TANK TOPS IAW 46 CFR_x001C_ 111.105-31 (l). (NOTE: REMOVE GASKET MATERIAL FROM SWITCH BOX COVERS. INSTALL ACCEPTED EXPLOSIVE PROOF FITTINGS AT BOTTOM OF SWITCH BOX)_x001C_
Condition: Unknown
Due 9 November 1992
Resolved 9 November 1992
Electrical
Issued 19 October 1992
Resolved
CORRECT OVERSPEED SETTINGS ON BOTH GENERATORS IN THE BOILER HOUSE. SETTINGSMUST NOT BE GREATER THAN 15 PERCENT ABOVE RATED RPM FOR GENERATOR BELL OR_x001C_ NOT GREATER THAN 2070 RPMS._x001C_ _x001C_
Condition: Unknown
Due 19 October 1992
Resolved 19 October 1992
Deck/Cargo
Issued 29 October 1990
Resolved
NO N.L.S. CARGOES MAY BE CARRIED UNTIL PROPER HANDLING AND SAFETY INSTRUCTION FOR EACH AUTHORIZED PRODUCT HAVE BEEN ENTERED IN THE LOADING MANUAL.
Condition: Unknown
Due 29 October 1990
Resolved 29 October 1990
Accommodation/Occupational Safety
Issued 18 July 1990
Resolved
REPLACE WASTED HANDRAILS ON LADDERS LEADING INTO CARGO TRANSFER ENGINE HOUSES NUMBER 2, NUMBER 3 AND NUMBER 4.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Deck/Cargo
Issued 18 July 1990
Resolved
REPAIR OR REMOVE HAND CRANK RATCHETS ON ALL DECK MOORING WINCHES
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Deck/Cargo
Issued 18 July 1990
Resolved
CLEAN AND DEMONSTRATE PROPER OPERATION OF ALL CARGO TANK PV VALVES.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Deck/Cargo
Issued 18 July 1990
Resolved
CLEAN INTERIOR AND MAKE AVAILABLE FOR INSPECTION, THE MAIN DECK AIR RECEIVER.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Deck/Cargo
Issued 18 July 1990
Resolved
MAKE PERMANENT REPAIRS TO ALL FOUR (4) CARGO TRANSFER ENGINE THROTTEL CABLES.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Deck/Cargo
Issued 18 July 1990
Resolved
DEMONSTRATE OPERATION OF NUMBER 1 STARBOARD FENDER WINCH.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Deck/Cargo
Issued 18 July 1990
Resolved
DEMONSTRATE CERTIFICATION OF DECK CRANES (2 OF THEM) AND ASSOCIATED CARGO GEAR AS REQUIRED BY 46CFR31.1-16.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Deck/Cargo
Issued 18 July 1990
Resolved
DEMONSTRATE PROPER OPERATION OF BOTH THE PORT AND STARBOARD ANCHOR WINDLASS.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Deck/Cargo
Issued 18 July 1990
Resolved
REPLACE MISSING VALVE HANDLE ON DECK AIR LINE SERVING FORWARD PORT AND STARBOARD WINCHES.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Deck/Cargo
Issued 18 July 1990
Resolved
REPLACE BROKEN HANDLE ON FORWARD ANCHOR WINDLASS HAND ENGAGING GEAR.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Navigation
Issued 18 July 1990
Resolved
DEMONSTRATE PROPER OPERATION OF ALL NAVIGATION LIGHTS
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Electrical
Issued 18 July 1990
Resolved
REPLACE MISSING GLOBE PROTECTION (PROTECTIVE CAGE) ON LIGHT INSIDE NUMBER1 CARGO TRANSFER ENGINE ROOM.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Deck/Cargo
Issued 18 July 1990
Resolved
PROVIDE PROPER CLOSING PINS FOR ALL CARGO TANK ULLAGE OPENINGS.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Deck/Cargo
Issued 18 July 1990
Resolved
REPLACE ALL CARGO TANK ULLAGE OPENING GASKETS.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Deck/Cargo
Issued 18 July 1990
Resolved
DEMONSTRATE PROPER OPERATION OF NUMBER 1 STARBOARD DECK (MOORING) WINCH
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Documentation
Issued 18 July 1990
Resolved
MOUNT OIL DISCHARGE PLACARD IN NUMBER 2 OIL TRANSFER ENGINE ROOM.
Condition: Unknown
Due 18 July 1990
Resolved 18 July 1990
Construction/Loadline
Issued 14 November 1989
Resolved
VESSEL PERMITTED TO OPERATE ON LAKES BAYS AND SOUNDS AND COASTWISE ROUTE ONLY.PRIOR TO COASTWISE VOYAGE,DAMAGED AREA IN WAY OF PORT SIDE BOW RAKE,#5SIDE LONG DOWN FROM DECK IS TO BE EXAMINED. IF CONDITION CHANGES COGNIZANT OCMI IS TO BE NOTIFIED.
Condition: Unknown
Due 14 November 1989
Resolved 14 November 1989
Electrical
Issued 9 September 1986
Resolved
REPLACE MISSING EXPANDED METAL OVER CABLE WAYS AFT OF #3 ENGINE. ALSO PROVIDE CABLE STRAPS WHERE MISSING THROUGHOUT VESSEL.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Documentation
Issued 9 September 1986
Resolved
SUBMIT NAME AND ADDRESS CHANGE TO COAST GUARD FOR CHANGE ON CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Electrical
Issued 9 September 1986
Resolved
REMOVE UNUSED ELECTRICAL WIRING AND RENEW ELECTRICAL WIRING WHERE NEEDED ATBOTH AIR COMPRESSOR ENGINE AND THEIR BATTERY BOX.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Electrical
Issued 9 September 1986
Resolved
PROVIDE PROPER BRACKET FOR AIR COMPRESSOR ROOM GENERATOR ALTERNATOR.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Unknown
Issued 9 September 1986
Resolved
REMOVE ALL PAINT CANS FROM BOILER ROOM.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986
Deck/Cargo
Issued 18 July 1983
Resolved
MAKE ALL PRESSURE VESSELS AVAILIBLE FOR INSPECTION.
Condition: Unknown
Due 18 July 1983
Resolved 18 July 1983
Fire Fighting
Issued 18 July 1983
Resolved
HAVE THE HALON SYSTEM SERVICED AND PROPERLY MARK THE CONTROLS FOR THIS SYSTEM.
Condition: Unknown
Due 18 July 1983
Resolved 18 July 1983
Deck/Cargo
Issued 18 July 1983
Resolved
CORRECT ALL MISFITTED ULLAGE FLAME SCREENS.
Condition: Unknown
Due 18 July 1983
Resolved 18 July 1983