MAURY USCG vessel records Sign in
← All vessels

CAPT BUCK

CAPT BUCK is a 1966 passenger vessel (uninspected). The Coast Guard has recorded 50 inspections since 1981, most recently in May 2012, along with 56 deficiencies and 1 operational control, 1 with no removal date recorded.

Records from 1981 to 2012. Most recent: inspection, 3 May 2012.

Built
1966
Last inspected
3 May 2012
Documentation
Not in the documentation file of 10 September 2026
Controls
1 with no removal date recorded

Identity

WYC7895
Flag
UNITED STATES
366301000 (licence lapsed)
Maury page id
psix-52702

Inspections, by type

…with no type recorded10
Years with a record 27 calendar years (1981–2012)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it17 - Regulatory (Subpart C or D), Net Ton
25 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WYC7895MMSI 366301000 · expired · compulsorily equipped · granted 20 June 1996, cancelled 18 November 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 50

3 May 2012 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4301945
17 December 2007 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3117125
14 December 2007 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3115926
18 May 2006 Type not recorded
No type recorded · USCGC STINGRAY (WPB 87305) · USCG Heartland District (CGD-H) · Activity 2665300
11 January 2006 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2565588
10 March 2005 Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2333330
17 February 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2008627
3 February 2004 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1999425
27 February 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1832277
21 February 2003 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1747463
7 February 2002 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1485131
21 June 2001 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1441914
21 March 2000 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1471581
9 February 2000 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1456916
26 March 1999 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1427676
4 February 1999 Plan Review "T" Boat
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1347935
13 April 1998 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1368699
28 January 1998 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1450128
31 March 1997 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1378005
4 February 1997 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1104113
3 April 1996 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1428628
14 February 1996 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1367650
16 November 1995 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 665856
11 July 1995 Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 37887
6 April 1995 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1385435
13 February 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1380161
4 April 1994 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1167984
9 December 1993 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 850214
19 October 1993 Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1151502
20 April 1993 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1142597
19 August 1992 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1248399
14 April 1992 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 960584
6 April 1992 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 960572
25 April 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1246104
11 April 1991 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1246707
31 August 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1235867
17 April 1990 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 910678
20 April 1989 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1034992
2 February 1989 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1031571
11 April 1988 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1342553
3 September 1987 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1010863
29 April 1987 Deficiency Check · Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1025020
22 April 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1293541
27 February 1986 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 991947
22 April 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1291384
16 July 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 974259
12 April 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 974258
3 May 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 967176
26 April 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969759
15 April 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 965059

Deficiency record · 56

Construction/Loadline › Hull › Side Shell
Issued 11 January 2006 Resolved
Found plank ends above and below water line, port and stbd side in way of stem decayed and loose. Repair to as built specifications IAW NVIC 7-95 prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2006
Resolved 11 January 2006
Construction/Loadline › Hull › Side Shell
Issued 11 January 2006 Resolved
Found several unauthorized repairs to decayed/loose plank butts (Dutchman) in way of water line, port and starboard side. Repair planks to as built specification IAW NVIC 7-95 prior to carrying passengers
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2006
Resolved 11 January 2006
Engineering › Steering Gear System › Rudder
Issued 11 January 2006 Resolved
Found port and starboard rudder bushings worn excessively. Remove rudders for further inspection and renew worn bushings to as built specifications IAW 46 CFR 176.800 and prior to carrying passengers for hire.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2006
Resolved 11 January 2006
Construction/Loadline › Hull › Hull Plating
Issued 11 January 2006 Resolved
Make vessel available for Hull and Internal Structural Examination as required by 46 CFR 176.600 and 610 prior to parrying more than 6 passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 January 2006
Resolved 11 January 2006
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 10 March 2005 Resolved
Obtain updated tide and tidal currents table. 46 CFR 184.420.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2005
Resolved 13 April 2005
Communications › Radio Communications › VHF Radiotelephone
Issued 10 March 2005 Resolved
Post emergency broadcast placard. 46 CFR 184.506.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2005
Resolved 13 April 2005
Lifesaving › Lifefloat › Serviceable
Issued 10 March 2005 Resolved
Repair life float, renew wasted pendants and lines. 46 CFR 180.200(a)(2).
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2005
Resolved 13 April 2005
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 10 March 2005 Resolved
Provide 06 adult lifejackets. 46 CFR 180.71.
Action required: 701 - Prior to carriage of passengers/cargo
Due 13 April 2005
Resolved 13 April 2005
Lifesaving › Lifebuoys › Serviceable
Issued 10 March 2005 Resolved
Repair or replace ring life buoy and floating water light painter. 46 CFR 180.70.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2005
Resolved 13 April 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 March 2005 Resolved
Provide approved first aid kit. 46 CFR 184.710.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2005
Resolved 13 April 2005
Navigation › Piloting/Steering › Marine Charts
Issued 10 March 2005 Resolved
Provide marine chart for operating area. 46 CFR 184.420.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 March 2005
Resolved 13 April 2005
Engineering › Bilge Water Management System
Issued 3 February 2004 Resolved
Remove oil from engine room and properly dispose of. LEGACY COMPONENT DESC: Excess Oil
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 February 2004
Resolved 17 February 2004
Resolution: Owner removed oil from E/R and properly disposed of.
Construction/Loadline › Hull
Issued 3 February 2004 Resolved
Remove angel hair from all underdeck transverse supports for further inspection. LEGACY COMPONENT DESC: Transverse Frame
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 February 2004
Resolved 17 February 2004
Resolution: Owner removed angel hair and treated, all underdeck transverse frames, sat.
Construction/Loadline › Hull
Issued 3 February 2004 Resolved
Renew gusset port side E/R 5th frame fwd of aft E/R bkhd. LEGACY COMPONENT DESC: Transverse Frame
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2004
Resolution: Owner renewed gusset port side 5th frame fwd of aft E/R bkhd.
Construction/Loadline › Hull
Issued 3 February 2004 Resolved
Clean all longitudinal frames and transverse frames of wasted wood and reinspect. LEGACY COMPONENT DESC: Longitudinal Frame
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2004
Resolution: Owner cleaned all longitudinal and transverse frames of wasted wood and inspection sat.
Construction/Loadline › Hull
Issued 3 February 2004 Resolved
Repair stbd side 8' fwd of transom 1st plank below chine - butt block. LEGACY COMPONENT DESC: Butt Block
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2004
Resolution: Owner repaired stbd side 8'' fwd of transom 1st plank below chine - butt block.
Construction/Loadline › Hull
Issued 3 February 2004 Resolved
Renew butt block stbd side 10' fwd of transom 1st plank above chine. LEGACY COMPONENT DESC: Butt block
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2004
Resolution: Owner renewed butt block stbd side 10'' fwd of transom and 1st plank above chine.
Construction/Loadline › Hull
Issued 3 February 2004 Resolved
Renew butt block refasten plank 12' fwd of transom 1st plank above chine. LEGACY COMPONENT DESC: Butt block
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2004
Resolution: Owner renewed butt block and refastened plank 12'' fwd of transom 1st plank above chine.
Construction/Loadline › Hull
Issued 3 February 2004 Resolved
Renew butt block refasten plank 14' fwd transom 1st plank above chine. LEGACY COMPONENT DESC: Butt block
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2004
Resolution: Owner renewed butt block and refastened plank 14'' fwd of transom 1st plank above chine.
Construction/Loadline › Hull
Issued 3 February 2004 Resolved
Renew port side butt block 15' aft of stem 2nd plank above chine. LEGACY COMPONENT DESC: Butt block
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2004
Resolution: Owner renewed port side butt block 15'' aft of stem 2nd plank above chine.
Engineering › Sea-water System (primary cooling)
Issued 3 February 2004 Resolved
Renew port main engine sea suction valve. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2004
Resolution: Owner renewed port main engine sea suction valve.
Construction/Loadline › Hull
Issued 3 February 2004 Resolved
Renew butt block port side 14' fwd of transom 1 plank down from chine. LEGACY COMPONENT DESC: Butt block
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 February 2004
Resolution: Owner renewed butt block port side 14'''' fwd of transom 1 plank down from chine.
Navigation › Piloting/Steering
Issued 21 February 2003 Resolved
Provide Coast Pilot and CG Light List IAW 46 CFR 184.420. LEGACY COMPONENT DESC: Coast Guard Light List
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2003
Resolved 27 February 2003
Resolution: Owner purchased nav pubs.
Lifesaving › Inflatable Liferafts
Issued 21 February 2003 Resolved
Provide New water light IAW 46 CFR 185.604(g). LEGACY COMPONENT DESC: Lamp (outside)
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2003
Resolved 27 February 2003
Resolution: Owner renewed water light.
Engineering › Fuel Oil Service System
Issued 21 February 2003 Resolved
Repair fuel leak at F/O shut off valve. LEGACY COMPONENT DESC: Valve
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 March 2003
Resolved 27 February 2003
Resolution: Fuel leak repaired.
Pollution Prevention/Response › Response Equipment
Issued 21 February 2003 Resolved
Remove F/O from bilge and dispose of properly. LEGACY COMPONENT DESC: Sorbents
Action required: 705 - Other - as specified
Due 21 March 2003
Resolved 27 February 2003
Resolution: Oil removed from bilge.
Electrical › Electric Supply System (service)
Issued 21 February 2003 Resolved
Metal strap and secure electrical cables, stbd outboard of main engine IAW 46 CFR 183.340. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 21 March 2003
Resolved 27 February 2003
Resolution: Cable strapped and supported properly.
Engineering › Fuel Oil Service System › Piping
Issued 7 February 2002 Resolved
Repipe fuel oil system IWO the fuel shut off valves and fuel oil service piping.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2002
Resolved 8 February 2002
Resolution: Owner renewed fuel oil piping with approved fittings and piping.
Construction/Loadline › Penetrations › Valve Flange
Issued 7 February 2002 Resolved
Renew stbd main engine Sea Valve.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2002
Resolved 8 February 2002
Resolution: O/O renewed Stbd main engine sea valve w/New ball valve.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 7 February 2002 Resolved
Remove all oil from engine room bilge.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2002
Resolved 8 February 2002
Resolution: Owner /Operator presure washed engine room bilge and desposed of excess oil residue.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 7 February 2002 Resolved
Have fixed and portable firefighting equipment serviced by and authorized facility.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2002
Resolved 8 February 2002
Resolution: Owner had fire fighting equipment serviced.
Engineering › Bilge Water Management System
Issued 7 February 2002 Resolved
Double hose clamp all through hull flexible piping on bilge piping. LEGACY COMPONENT DESC: Hose
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 March 2002
Resolved 8 February 2002
Resolution: Owner installed double hose clamps on bilge flexable piping at overboard valves.
Lifesaving › Lifebuoys
Issued 21 June 2001 Resolved
Renew deteriorated ring life buoy to the satisfaction of the attending marine inspector.
Due 21 June 2001
Resolved 21 June 2001
Resolution: Examined and found satisfctory installation of new ring life buoy.
Lifesaving › Buoyant Apparatus
Issued 21 June 2001 Resolved
Renew batteries to life float water light. LEGACY COMPONENT DESC: Water Light
Due 21 June 2001
Resolved 21 June 2001
Resolution: Examined and found satisfactory renewal of water light batteries.
Fire Fighting
Issued 21 March 2000 Resolved
46 CFR 181.400 - HAVE FIXED FIRE FIGHTING SYSTEM TESTED IAW MANUFACTURERS REQUIREMENTS.
Condition: Unknown
Due 21 March 2000
Resolved 14 June 2000
Fire Fighting
Issued 21 March 2000 Resolved
46 CFR - 181.500 - PROVIDE ONBOARD -2- B-II PORTABLE FIRE EXT.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Lifesaving
Issued 21 March 2000 Resolved
46 CFR 180.200 - STORE LIFE FLOAT IN A FLOAT FREE LOCATION.
Condition: Unknown
Due 14 June 2000
Resolved 14 June 2000
Documentation
Issued 21 March 2000 Resolved
33 CFR 151.57 - POST A WASTE MANAGMENT PLAN
Condition: Unknown
Due 21 March 2000
Resolved 14 June 2000
Fire Fighting
Issued 14 April 1992 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Engineering
Issued 14 April 1992 Resolved
LOCATE AND REPAIR OIL LEAK TO STARBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Navigation
Issued 14 April 1992 Resolved
TIGHTEN BOTH P/S RUDDER POST PACKING GLANDS.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Engineering
Issued 14 April 1992 Resolved
PROPER LABEL EMERGENCY SHUTOFF VALVES.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Lifesaving
Issued 14 April 1992 Resolved
PROPERLY LABEL LIFE JACKET STORAGE LOCKERS WITH AMOUNT OF LIFE PRESERVERS STORED WITHIN.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Lifesaving
Issued 14 April 1992 Resolved
ATTACH LABELS TO LIFE FLOAT.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Electrical
Issued 14 April 1992 Resolved
LABEL ALL ELECTRICAL CIRCUIT BREAKER PANELS WITH CIRCUITS INTENDED USE.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Navigation
Issued 14 April 1992 Resolved
THE MASTHEAD LIGHT SHALL BE PLACED AT A HEIGHT ABOVE THE GUNWALE OF NOT LESS THAN 2.5 METERS.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Navigation
Issued 14 April 1992 Resolved
INSTALL NAVIGATION LIGHTS THAT MEET THE FOLLOWING VISIBILITY REQUIREMENTS: MASTLIGHT - 3 MILES_x001C_ SIDELIGHT - 2 MILES_x001C_ STERNLIGHT - 2 MILES
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Construction/Loadline
Issued 14 April 1992 Resolved
INSTALL FIXED PIPING TO ALL BILGE PUMP DISCHARGE OF ATLEAST 1" IN DIAMETER.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Construction/Loadline
Issued 14 April 1992 Resolved
PROVE WATER TIGHTNESS OF STERN DECK HATCH.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Construction/Loadline
Issued 14 April 1992 Resolved
REMOVE ALL OIL FROM ENGINE ROOM BILGES.
Condition: Unknown
Due 14 April 1992
Resolved 14 April 1992
Fire Fighting
Issued 11 April 1991 Resolved
INSTALL LONGER SUCTION HOSES FOR PORTABLE FIRE PUMP._x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Lifesaving
Issued 11 April 1991 Resolved
INSTALL 24" RING BUOY IN LIEU OF 20" PRESENTLY ONBOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Electrical
Issued 11 April 1991 Resolved
REPAIR/REPLACE AC AMP METER._x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Electrical
Issued 11 April 1991 Resolved
INSTALL FREQUENCY METER FOR AC GENERATOR._x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Lifesaving
Issued 11 April 1991 Resolved
RENEW LIFE FLOAT WITH EITHER LIFE FLOAT OR BUOYANT APPARATUS._x001C_ _x001C_
Condition: Unknown
Due 18 July 1991
Resolved 18 July 1991
Navigation
Issued 29 April 1987 Resolved
REMOVE FORWARD FACING PANES OF TINTED GLASS (3) IN SALON, REPLACE WITH CLEAR GLASS.
Condition: Unknown
Due 29 April 1987
Resolved 29 April 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.