WILL BORDELON

WILL BORDELON is a 1981 offshore supply vessel. The Coast Guard has recorded 54 inspections since 1981, most recently in December 2016, along with 38 deficiencies and 2 casualty investigations between 2006 and 2008.

Records from 1981 to 2016. Most recent: inspection, 19 December 2016.

Built
1981
Last inspected
19 December 2016
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WBC7534
Flag
UNITED STATES
367149930 (licence lapsed)
Maury page id
psix-52705

Inspections, by type

…with no type recorded16
Years with a record 28 calendar years (1981–2016)
The 54 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)83.5 ft × 24.0 ft × 7.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderOFFSHORE TRAWLERS INC · BAYOU LA BATRE, AL, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WBC7534MMSI 367149930 · expired · compulsorily equipped · granted 9 November 2006, cancelled 18 February 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 54

19 December 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6060133
21 August 2014 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4961112
18 March 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4817683
14 March 2014 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4814840
23 February 2009 Examination of Repairs · Internal Structural Exam · Hull Examination · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3438432
30 January 2009 Drydock Extension
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3403818
11 August 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3295345
9 January 2008 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3127712
6 January 2008 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3128607
20 July 2007 In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3001335
20 July 2007 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3001342
5 January 2007 COI Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2852173
24 March 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2644822
6 February 2006 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2578917
30 January 2006 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2575934
22 April 2005 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2340372
1 November 2004 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2232333
30 January 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2004039
5 January 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1975098
25 November 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1954002
14 October 2003 Type not recorded
No type recorded · Station New Orleans · USCG Heartland District (CGD-H) · Activity 1928269
22 January 2003 Hull Examination · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1727954
13 March 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1494793
23 April 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1062654
11 January 2001 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462917
12 April 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1124637
17 June 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1111486
15 August 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1187409
29 June 1995 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1412831
24 June 1994 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1428382
7 July 1993 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1450778
31 December 1992 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1140368
9 July 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1465722
26 September 1991 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 934124
5 August 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1249824
19 July 1991 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1250925
29 March 1990 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 982957
28 January 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 512984
5 October 1989 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1017576
28 July 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 470380
31 May 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 511019
31 March 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1346552
11 April 1988 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036973
29 December 1987 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008826
13 October 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322573
3 April 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1020677
20 August 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296353
8 April 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307848
11 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290894
27 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283647
29 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274378
3 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968482
3 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963964
29 May 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1275631

Deficiency record · 38

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 11 August 2008 Resolved
Place 30 x 30 screens on fuel and sewage vents
Due 10 September 2008
Resolved 16 September 2008
Resolution: Screens installed.
Accommodation/Occupational Safety › Other Accommodation Spaces › Insect Screen
Issued 11 August 2008 Resolved
Place insect screen on potable water vent
Due 10 September 2008
Resolved 16 September 2008
Resolution: Screen installed
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 August 2008 Resolved
Replace household bulbs with proper navigation lights
Due 10 September 2008
Resolved 16 September 2008
Resolution: Bulbs replaced with proper navigation lights.
Fire Fighting › Structural Fire Protection - General › Cooking Area
Issued 11 August 2008 Resolved
Place pot rack on stove
Due 10 September 2008
Resolved 16 September 2008
Resolution: Rack placed on stove
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 11 August 2008 Resolved
Place smoke detectors in each berthing room
Due 10 September 2008
Resolved 16 September 2008
Resolution: Smoke detectors installed
Communications › Public Address System › Loudspeaker
Issued 11 August 2008 Resolved
Provide public address system for berthing and galley areas
Due 10 September 2008
Resolved 16 September 2008
Resolution: Speakers added to system
Engineering › Fuel Oil Service System › Valve
Issued 11 August 2008 Resolved
Provide an auto shut off valve for fuel tank sight glass
Due 10 September 2008
Resolved 16 September 2008
Resolution: Valve installed.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 11 August 2008 Resolved
Paint draft markings in contrasting color to hull
Due 16 September 2008
Resolved 16 September 2008
Resolution: Draft marks painted
Personnel › Certificates/Documents/Licenses › License, Mate
Issued 20 July 2007 Resolved
Vessel operating without a Lic Mate on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 August 2008
Construction/Loadline › Hull › Hull Plating
Issued 5 January 2007 Resolved
Four inserts were required to replace damaged plating. 1) Stern Wrap (stbd): 54" x 38" 2) Stbd Quarter: 18" x 24" 3) Port Bow: 18" x 20" 4) Stbd Bow: 18" x 18"
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 January 2007
Construction/Loadline › Hull › Bottom Plating
Issued 5 January 2007 Resolved
5) Noted wastage in the deck plating near the stuffing boxes in the engine room requiring inserts. Port side: 54" x 22" and Starboard: 35" x 44".
Action required: 17 - Rectify deficiencies prior to departure
Due 12 January 2007
Resolved 12 January 2007
Documentation › Certificates/Documents › FCC SSL
Issued 5 January 2007 Resolved
FCC Station License and Safety Cetificate had expired.
Action required: 705 - Other - as specified
Resolved 27 February 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 5 January 2007 Resolved
Bilge alarm was not labeled at the operating station.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2007
Construction/Loadline › Structures › Superstructure
Issued 5 January 2007 Resolved
The superstructure had windows with leaking gaskets and through sturcture holes that were not properly sealed to prevent water from entering.
Due 28 February 2007
Resolved 27 February 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 January 2007 Resolved
Proper marine grade bulbs were not installed.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2007
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 5 January 2007 Resolved
Water lights for the lifering buoys were not properly mounted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 February 2007
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 5 January 2007 Resolved
Some PFD's did not have the vessel name stenciled on.
Due 28 February 2007
Resolved 2 February 2007
Navigation › Piloting/Steering › Gyro Compass
Issued 5 January 2007 Resolved
The light for the magnetic compass was not operational.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 5 January 2007 Resolved
Exterior lighting fixtures were missing bulbs and globes.
Due 28 February 2007
Resolved 2 February 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 5 January 2007 Resolved
The first aid kit and standby service medical kit was were not adequately supplied.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 February 2007
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 5 January 2007 Resolved
Open spaces within the circuit breaker box were not blanked off.
Due 28 February 2007
Resolved 2 February 2007
Accommodation/Occupational Safety › Occupational Safety › Receptacle Outlet
Issued 5 January 2007 Resolved
Electrical outlets and light swtitches were not mounted properly.
Due 28 February 2007
Resolved 2 February 2007
Construction/Loadline › Hull › Hull Plating
Issued 30 January 2006 Resolved
PROCEED TO DRYDOCK TO COMPLETE A CREDIT DRYDOCK EXAM.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 February 2006
Resolved 12 March 2006
Resolution: 835 cleared as vessel is serving as an ORV.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 21 April 2005 Resolved
Vessel found overloaded, Master to bring vessel into compliance with stability letter dated 28OCT83 prior to departure from dock and at all other times.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 April 2005
Resolved 21 April 2005
Communications › Radio Communications › Emergency Source of Power
Issued 5 January 2004 Resolved
Provide backup power to SSB & 1 VHF radio lack back.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2004
Resolution: Technician brought in during inspection. Discussed requirements for SPV''s. Approved method and equipment to be used.
Stability › Watertight Integrity
Issued 5 January 2004 Resolved
Replace missing main deck soft patch bolts. LEGACY COMPONENT DESC: Soft Patch
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2004
Resolution: Bolts replaced.
Operations/Management › Pollution
Issued 5 January 2004 Resolved
Excessive fuel oil in bilges. Pump down bilges to approved facility, clean, and correct source of fuel leak. LEGACY COMPONENT DESC: Retention of Oily Mixture
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2004
Resolution: Corrected.
Engineering
Issued 24 June 1994 Resolved
REPAIR FUEL LEAK AT STARBOARD GENSET PRIME MOVER FLEXIBLE FUEL RETURN LINE.
Condition: Unknown
Due 24 June 1994
Resolved 7 September 1994
Navigation
Issued 24 June 1994 Resolved
VESSEL DID NOT HAVE A COPY OF INLAND NAV. RULES ON BOARD.
Condition: Unknown
Due 24 June 1994
Resolved 7 September 1994
Electrical
Issued 24 June 1994 Resolved
REMOVE THE EXTENSION CORD SPLICED INTO THE BUNK LIGHT OF THE PORT SIDE LOWER COMPARTMENT.
Condition: Unknown
Due 24 June 1994
Resolved 7 September 1994
Engineering
Issued 19 July 1991 Resolved
REMOVE ALL FUEL OIL TRANSFER EQUIPMENT WHICH IS USED TO TRANSFER FUEL TO OTHER VESSELS. VESSEL IS NOT AUTHORIZED TO CARRY FUEL FOR USE BY OTHER VESSELS.
Condition: Unknown
Due 19 July 1991
Resolved 19 July 1991
Electrical
Issued 19 July 1991 Resolved
INSTALL AND TEST EMERGENCY LIGHTING IN THE FOLLOWING AREAS: GALLEY EXIT,_x001C_ PUMP ROOM LADDER, AND ENGINE ROOM ESCAPE LADDER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 September 1991
Resolved 4 September 1991
Engineering
Issued 19 July 1991 Resolved
INSTALL SUITABLE DRAIN PLUGS FOR RACOR FILTERS ON PORT GENERATOR AND STARBOARD MAIN ENGINE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 July 1991
Resolved 19 July 1991
Construction/Loadline
Issued 13 October 1987 Resolved
REPAIRS MADE TO KEEL COOLER DAMAGED ON 29JUL87 AND TO BE EXAMINED AT NEXT DRYDOCK EXAMINATION.
Condition: Unknown
Due 13 October 1987
Resolved 13 October 1987
Unknown
Issued 29 July 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL WILL BORDELON, DN636158.
Condition: Unknown
Due 29 July 1983
Resolved 29 July 1983
Construction/Loadline
Issued 29 July 1983 Resolved
SUBMIT TO CCGD8 MMT FOR STABILITY ANALYSIS REVIEW, CORRECT WEIGHTS AND CALCULATIONS THAT REFLECT NEW MODIFICATION.
Condition: Unknown
Due 29 July 1983
Resolved 29 July 1983
Deck/Cargo
Issued 29 July 1983 Resolved
CHANGE APPROXIMATELY 40 FEET OF RUBBER HOSE TO HARD PIPE FROM F/O DAY TANK TO SKID GENERATOR SET ON DECK.
Condition: Unknown
Due 29 July 1983
Resolved 29 July 1983
Unknown
Issued 29 July 1983 Resolved
PROVIDE APPROVED PLANS FOR INSTALLATION OF AIR CONDITIONER AT NEW SURVEY ROOM.
Condition: Unknown
Due 29 July 1983
Resolved 29 July 1983

Casualty record · 2

24 March 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · activity 2644822
6 January 2008Routine · role: Involved in a Marine Casualty · activity 3128607
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record