Records from 1980 to 1995. Most recent: inspection, 28 December 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
28 December 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 875317
16 August 1995
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1184121
18 October 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869652
21 September 1994
COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1179674
18 April 1994
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1172842
11 January 1994
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1161705
24 November 1993
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1160386
22 March 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1142852
20 January 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1134981
17 October 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 944456
18 September 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1252570
4 October 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 940116
4 October 1991
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 956630
4 October 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1253005
21 September 1990
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 913561
10 November 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 931318
30 March 1989
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1041480
14 March 1988
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305701
10 July 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1337278
2 June 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303776
26 February 1986
Sanitary Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305470
31 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285151
13 March 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 969430
18 December 1980
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971024
Electrical
Issued 21 September 1994
Resolved
PROVIDE PROPER ELECTRICAL INSTALLATION IN GALLEY STOREROOM OVERHEAD LGHT._x001C_ THE ABOVE (2) ITEMS TO BE CLEARED VIA FAX TO MIONY [phone withheld] 10/STATEMENT FROM MASTER INCL. LIC. #,PORT OF ISSUE AND EXP. DATE.
Condition: Unknown
Due 8 November 1994
Resolved 8 November 1994
Engineering
Issued 21 September 1994
Resolved
PROVE PROPER OPERATION OF OVERSPEED TRIP ON PORT MAIN DIESEL.
Condition: Unknown
Due 21 September 1994
Resolved 21 September 1994
Lifesaving
Issued 24 November 1993
Resolved
PROVIDE ADEQUATE RESCUE PLATFORM TO RETRIEVE A PERSON OUT OF WATER, THIS REQT IS TO BE CLEARED TO THE SATISFACTION OF ATTENDING MARINE INSPECTION PRIOR 31DEC93.
Condition: Unknown
Due 24 November 1993
Resolved 24 November 1993
Accommodation/Occupational Safety
Issued 18 September 1992
Resolved
PROVIDE PROPER OPERATION OF AC REMOTE SHUTDOWN._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Deck/Cargo
Issued 18 September 1992
Resolved
REPAIR ANCHOR WINDLASS AND PROVE PROPER OPERATION OF THE SAME.
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Engineering
Issued 18 September 1992
Resolved
HYDRO TEST BOTH AIR RECEIVERS. MUST BE WITNESSED BY COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Engineering
Issued 18 September 1992
Resolved
PROVIDE 30 X 30 MESH FLAME SCREENS FOR FUEL VENTS.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Electrical
Issued 18 September 1992
Resolved
PROVIDE PROPER LINING FOR BATTERY BOXES.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Accommodation/Occupational Safety
Issued 18 September 1992
Resolved
REPLACE REEFER DOOR LOCATED ON THE WEATHER DECK.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Accommodation/Occupational Safety
Issued 18 September 1992
Resolved
PROVIDE EXHAUST VENT COVER FOR STOVE IN GALLEY.
Condition: Unknown
Due 18 September 1992
Resolved 18 September 1992
Navigation
Issued 18 September 1992
Resolved
REPAIR RUDDER INDICATOR ON BRIDGE AND PROVE PROPER OPERATION OF THE SAME.
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Electrical
Issued 18 September 1992
Resolved
PROVE PROPER OPERATION OF PORT GENERATOR.
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Documentation
Issued 18 September 1992
Resolved
PROVIDE CURRENT COPY OF 46 CFR SUBCHAPTER "T"._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Lifesaving
Issued 18 September 1992
Resolved
LABEL LIFE JACKET COMPARTMENT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Documentation
Issued 18 September 1992
Resolved
PROVIDE EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Lifesaving
Issued 18 September 1992
Resolved
PROVIDE UP-TO-DATE HAND AND SMOKE SIGNALS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Construction/Loadline
Issued 18 September 1992
Resolved
REPLACE GASKET ON E/R ESCAPE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 November 1992
Resolved 5 November 1992
Fire Fighting
Issued 30 March 1989
Resolved
OPERATIONALLY TEST FIRE PUMP AND ENERGIZE HOSE IN THE PRESENCE OF A C.G. MARINE INSPECTOR.
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Documentation
Issued 30 March 1989
Resolved
PROVIDE COPY OF VALID LOADLINE CERTIFICATE UPON RECEIPT FROM ABS IN ACCORDANCE WITH SUBCHAPTER "E" CODE OF FEDERAL REGULATIONS.
Condition: Unknown
Due 30 March 1989
Resolved 30 March 1989
Documentation
Issued 2 June 1986
Resolved
PROVIDE ON BAORD A VALID FCC CERTIFICATE.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986
Lifesaving
Issued 2 June 1986
Resolved
INFLATABLE LIFE RAFT IS TO BE SERVICED BY APPROVED COAST GUARD FACILITIES.
Condition: Unknown
Due 2 June 1986
Resolved 2 June 1986