Records from 1981 to 2011. Most recent: inspection, 13 December 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 36
13 December 2011
Load Line/Change of Employment · Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4207653
29 September 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3068904
29 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2933374
29 March 2007
COC-MODU Renew · Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2877788
9 June 2006
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2674688
25 August 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2474266
24 August 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2473510
22 August 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2473425
26 July 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2474247
24 May 2005
COC-MODU Renew
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2366078
1 January 1998
Administrative
Administrative · Commandant (CG-CVC) · Activity 785629
24 April 1997
Administrative
Administrative · Activities Europe · Activity 1097578
11 March 1997
Administrative
Administrative · Activities Europe · Activity 1101131
24 December 1996
Type not recorded
No type recorded · Activities Europe · Activity 1095884
25 October 1990
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1227293
28 September 1990
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1228447
17 August 1990
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 930991
25 April 1990
Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 903441
17 November 1987
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1333045
19 August 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1021834
13 August 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1005005
28 July 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025937
9 April 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334326
1 June 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990491
1 May 1986
COI Inspection · Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1298192
10 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982049
21 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287628
29 June 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974029
18 June 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974028
13 June 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974021
1 May 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 972531
20 March 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280815
23 February 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971529
8 July 1983
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 965570
2 May 1982
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1276094
17 July 1981
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 965926
Fire Fighting › Structural - B Class Divisions › Doors
Issued 29 March 2007
Resolved
Install Class "B" door between change room and washroom
Action required: 705 - Other - as specified
Due 28 April 2007
Resolved 29 May 2007
Resolution: Vsl installed Class B door between change room and washroom.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 29 March 2007
Resolved
Repair/replace air bottle hose in #1 lifeboat.
Due 31 March 2007
Resolved 30 March 2007
Resolution: Replaced and tested new air hose satisfactorily.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 29 March 2007
Resolved
Provide/submit Emergency Evacuation Plan (EEP) for approval.
Due 30 March 2007
Resolved 30 March 2007
Resolution: EEP submitted to and approved by PATMS.
Construction/Loadline
Issued 1 May 1986
Resolved
CLEAN, ADJUST, AND REPAIR AS NECESSARY ALL WATERTIGHT DOORS. ITEM SHALL BE ACCOMPLISHED PRIOR TO THE GRANTING OF A DRYDOCK EXTENSION.
Condition: Unknown
Due 1 May 1986
Resolved 1 May 1986
Electrical
Issued 1 May 1986
Resolved
SUBMIT THE RIG HAZARDOUS LOCATIONS PLAN TO THE COGNIZANT OCMI AND PROVIDE THE APPROVED PLAN ON THE RIG.
Condition: Unknown
Due 1 May 1986
Resolved 1 May 1986
Fire Fighting
Issued 1 May 1986
Resolved
PROVIDE ON THE RIG, A COPY OF D8(MMT) LTR OF 01APR81 APPROVING THE OPERATING MANUAL AND [name withheld] OF 05NOV80 APPROVING THE FIRE CONTROL PLAN.
Condition: Unknown
Due 1 May 1986
Resolved 1 May 1986
Fire Fighting
Issued 1 May 1986
Resolved
PROVIDE A RELIEF VALVE ON THE NO. 1 FIRE PUMP SET FOR NOT MORE THAN 125 PSI.
Condition: Unknown
Due 1 May 1986
Resolved 1 May 1986
Unknown
Issued 21 May 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL NN1 DN600160
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Lifesaving
Issued 21 May 1985
Resolved
PROVIDE (12) HAND HELD RED FLARES FOR THE PORT SURVIVAL CAPSULE 46CFR 109. 217.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Unknown
Issued 21 May 1985
Resolved
PROVIDE CONTAINMENT AT FUEL OIL TRANSFER STATION BELOW WHERE HOSE CONNECT- ION MEETS WITH PIPING IN ACCORDANCE WITH 33CFR155.320.
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Fire Fighting
Issued 21 May 1985
Resolved
PROVIDE (1) INDEPENDENT TESTING LABORATORY APPROVED OXYGEN/EXPLOSIVE METER 46CFR108.497
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Electrical
Issued 21 May 1985
Resolved
REPAIR LOW LUBE OIL PRESSURE LIGHT ON EMERGENCY GENERATOR IN ACCORDANCE WITH NVIC 4-78
Condition: Unknown
Due 21 May 1985
Resolved 21 May 1985
Unknown
Issued 1 May 1984
Resolved
PROVIDE SUITABLE CONTAINMENT FOR PORT AND STARBOARD FUEL TAKE-ON MANIFOLDS.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
STENCIL ALL MOTOR CONTROLLERS, VENTS, AND GENERAL ALARMS AS NEEDED THROUGHOUT THE RIG.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
INSTALL GENERAL ALARM BELL ON PORT AND STARBOARD SIDE OF QUARTERS ON THE MAIN DECK.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Documentation
Issued 1 May 1984
Resolved
DESIGNATE CRANE OPERATORS IN WRITING.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Documentation
Issued 1 May 1984
Resolved
DESIGNATE PERSON IN CHARGE IN WRITING.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Electrical
Issued 1 May 1984
Resolved
PROVIDE INSULATION FOR EMERGENCY GENERATOR MANIFOLD AND EXHAUST.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Fire Fighting
Issued 1 May 1984
Resolved
ADJUST QUARTERS ENTRANCE FIRE DOORS SO THEY ARE SELF-CLOSING.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
INSTALL A WIND INDICATING DEVICE.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Fire Fighting
Issued 1 May 1984
Resolved
HYDROSTATICALLY TEST BOTH B-V SEMI-PORTABLE EXTINGUISHERS ON HELIPORT.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Construction/Loadline
Issued 1 May 1984
Resolved
REMOVE LOCKING DEVICES FROM MACHINERY WATER TIGHT DOORS.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Documentation
Issued 1 May 1984
Resolved
PROVIDE HAZARDOUS LOCATION PLAN ON BOARD.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
REPAIR SPRING OPERATED CLOSURE ON FORKLIFT FUEL FILL LINE.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
PROVIDE PROPER FUELING EQUIPMENT FOR FORKLIFT.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
INSTALL AUDIBLE WARNING DEVICE ON FORKLIFT TRUCK.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Documentation
Issued 1 May 1984
Resolved
PROVIDE PROOF THAT FORKLIFT IS UL OR FM APPROVED.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
REPAIR PORT CRANE ACCESS LADDER SAFETY RAIL.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
INSTALL FLAME SCREEN ON PAINT LOCKER VENTS.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
STENCIL "E" ON DRILL FLOOR EMERGENCY LIGHTS.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Electrical
Issued 1 May 1984
Resolved
REPAIR AUDIBLE ALARM ON #1 S/S GENERATOR.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
INSTALL INDIVIDUAL RELIEF VALVES ON P-TANKS.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Electrical
Issued 1 May 1984
Resolved
PROVIDE PROPER PACKING OF THREE CABLES RUNNING THROUGH QUARTERS BULKHEAD FACING THE DRILL FLOORS.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Electrical
Issued 1 May 1984
Resolved
REPAIR DEFECTIVE LIGHT FIXTURE ABOVE MUD PITS.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Electrical
Issued 1 May 1984
Resolved
REPLACE SPLICED WELDING CABLE IN MUD PUMP/PIT ROOMS WITH NON-SPLICED CABLE OR MAKE CONNECTIONS IN J-BOX; MAKE PROPER BHD PENETRATION AND SUPPORT CABLE
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Construction/Loadline
Issued 1 May 1984
Resolved
REMOVE PAINT FROM GASKETS TO WATER TIGHT DOORS AS NEEDED AROUND THE RIG.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
CONDUCT FIRE AND ABANDON RIG DRILLS FOR A U. S. COAST GUARD INSPECTOR WHEN RIG IS PLACED IN SERVICE.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Construction/Loadline
Issued 1 May 1984
Resolved
REPLACE DEFECTIVE GASKET TO DOOR FROM MUD PUMP ROOM TO MUD PIT ROOM.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Construction/Loadline
Issued 1 May 1984
Resolved
REPLACE ALL MISSING BOLTS TO MAN HOLE COVERS THROUGHOUT THE RIG AS NEEDED.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Electrical
Issued 1 May 1984
Resolved
REPAIR WIRE CABLE HOLDERS ON THE SHALE SHAKER.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Fire Fighting
Issued 1 May 1984
Resolved
REPAIR LEAKING VALVES TO FIRE STATIONS #6 AND #7.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
PROVIDE ALTERNATE BLUE AND YELLOW LIGHTS AROUND HELIPORT PERIMETER.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Accommodation/Occupational Safety
Issued 1 May 1984
Resolved
REPLACE MISSING CONTROL SWITCH TO QUARTERS HEAD HEATER.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Electrical
Issued 1 May 1984
Resolved
LABEL REMOTE FUEL SHUT DOWN FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Documentation
Issued 1 May 1984
Resolved
PROVIDE CRANE RECORD BOOKS AS PER 46 CFR 109.437.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE NN 1, DN600160.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Electrical
Issued 1 May 1984
Resolved
PROVIDE ACID RESISTANT BATTERY BOX FOR EMERGENCY GENERATOR START BATTERIES.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 1 May 1984
Resolved
MAKE HELIPORT SURFACE NON-SKID.
Condition: Unknown
Due 1 May 1984
Resolved 1 May 1984
Unknown
Issued 23 February 1984
Resolved
MAKE PERMANENT REPAIRS TO THE OVER PRESSURIZED #9S BALLAST TANK.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Unknown
Issued 23 February 1984
Resolved
THE FOLLOWING DEFICIENCY IS FOR THE NN 1, DN600160.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984