Records from 1981 to 2009. Most recent: inspection, 21 April 2009.
Inspection history · 88
21 April 2009
Drydock Exam
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3457624
4 February 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3412420
3 September 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3317117
27 June 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3249924
4 May 2008
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3231945
1 May 2008
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3197260
16 May 2007
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2937268
19 July 2006
Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2716274
10 April 2006
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2620922
11 May 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2356120
15 July 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2167739
2 June 2004
Internal Structural Exam · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2086448
22 May 2003
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1798776
8 January 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1727713
29 April 2002
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1610352
5 December 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 772363
11 October 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1075567
4 September 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1072323
28 August 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1072545
25 July 2001
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1406995
19 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064009
10 April 2001
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1387037
17 July 2000
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 820408
12 June 2000
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1432346
30 July 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1111176
18 May 1999
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1110616
7 May 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 794363
12 April 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1423164
1 April 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 13445
2 November 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804860
19 September 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 799428
2 June 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1129371
28 May 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 791615
1 May 1998
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1406317
28 April 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1124007
26 March 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 788271
16 September 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1108091
18 August 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1118716
30 July 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 778029
12 June 1997
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 777052
9 April 1997
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1406088
27 March 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1094771
18 December 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093587
23 August 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1088759
8 August 1996
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1405956
13 June 1996
Damage Survey · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1430224
7 May 1996
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 103137
27 November 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 178181
27 June 1995
Examination of Repairs
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1435650
13 April 1995
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1416118
24 June 1994
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1026028
24 May 1994
Re-Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1400025
22 April 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1373832
17 January 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1142015
15 September 1992
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 951886
29 July 1992
Hull Examination · Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1269280
19 April 1991
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1236502
30 October 1989
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 914752
27 October 1989
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1206778
30 June 1989
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1219042
30 June 1989
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1235887
11 May 1989
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1031111
11 May 1989
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1222216
20 October 1988
Drydock Extension
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 892015
13 October 1988
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 886877
15 August 1988
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348739
27 July 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1338317
3 March 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1320228
20 January 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1319677
28 October 1986
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1315725
25 September 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1315999
7 August 1986
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1306253
19 February 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 986823
19 August 1985
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 989326
29 July 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1290557
27 June 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1291443
22 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 976761
8 August 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1282590
16 July 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1280731
8 May 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972659
9 March 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1281022
28 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283366
14 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273426
20 September 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967108
6 August 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965852
18 February 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1274979
17 August 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 971209
7 August 1981
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967139
Construction/Loadline › Hull › Bottom Plating
Issued 21 April 2009
No resolution recorded
Complete Phase II of SEILOD in accordance with SEILOD Plan at net rig move.
Action required: 705 - Other - as specified
Stability › Watertight Integrity › General
Issued 16 May 2007
Resolved
Replace weather tight door gasket with hard rubber watertight door gasket prior to rig movement.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 June 2007
Resolved 30 May 2007
Resolution: Replaced gaskets
Electrical › Electric Generation Source (service) › Generator
Issued 16 May 2007
Resolved
Replace tachometer on #1 Generator and prove proper overspeed trip.
Action required: 705 - Other - as specified
Due 16 June 2007
Resolved 30 May 2007
Resolution: Tachometer provided, over speed trip working properly
Electrical › Electric Generation Source (service) › Panelboard
Issued 16 May 2007
Resolved
Repair reverse power relay for both generator switchboards prior to drilling.
Action required: 705 - Other - as specified
Due 16 June 2007
Resolved 30 May 2007
Resolution: Reverse power relays working properly.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2007
Resolved
Terminate dead end wire above #1 Generator.
Action required: 705 - Other - as specified
Due 16 June 2007
Resolved 30 May 2007
Resolution: Dead wire removed
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 May 2007
Resolved
Terminate dead end wire in port bulkhead in mud room prior to using oil base muds.
Action required: 705 - Other - as specified
Due 16 June 2007
Resolved 30 May 2007
Resolution: Dead end wire removed and plugged.
Stability › Watertight Integrity › General
Issued 16 May 2007
Resolved
Repair hole in overhead to mud room at entrance prior to oil base mud.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 16 June 2007
Resolved 30 May 2007
Resolution: Clad welded hole
Stability › Watertight Integrity › General
Issued 16 May 2007
Resolved
Repair Rox MCT in mud room on starboard side prior to oil base mud.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 June 2007
Resolved 30 May 2007
Resolution: Replaced rox box with new one
Engineering › Pressure Vessel › Relief Valve
Issued 16 May 2007
Resolved
Provide documentation of calibrated guage for bench testing relief valves and retest valves.
Action required: 705 - Other - as specified
Due 29 May 2007
Resolved 30 May 2007
Resolution: Provided documentation that guages were calibrated.
Personnel › Training › Fire Fighting Basic
Issued 16 May 2007
Resolved
Demonstrate a satisfactory fire drill.
Action required: 705 - Other - as specified
Due 25 May 2007
Resolved 30 May 2007
Resolution: Conducted fire drill with no discrepencies
Fire Fighting › Firemans Outfit › Protective Clothing
Issued 16 May 2007
Resolved
Provide flash hoods for fire fighting ensemble.
Action required: 705 - Other - as specified
Due 16 June 2007
Resolved 30 May 2007
Resolution: Flash hoods procured and onboard ready for firefighting use.
Construction/Loadline › Hull › Hull Plating
Issued 19 May 2004
Resolved
Complete Phase II (underwater inspection) by 19 Aug 04 to the satisfaction of ABS/USCG surveyor and provide final report to MSO Morgan City, La. LEGACY COMPONENT DESC: Phase II Exam
Due 19 August 2004
Resolved 20 May 2005
Resolution: Documentation provided.
Operations/Management › Drills/Instruction
Issued 29 April 2002
Resolved
Perform fire and abandon ship drills to the satisfaction of attending marine inspector. LEGACY COMPONENT DESC: Fire
Due 30 September 2002
Resolved 22 October 2002
Engineering › Fuel Oil Service System
Issued 29 April 2002
Resolved
Replace stand pipe vent to fuel tank for emergency generator. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Due 29 May 2002
Resolved 28 May 2002
Engineering › Diesel Engine (auxiliary)
Issued 29 April 2002
Resolved
Renew or replace exhaust pipe for draw works engine #3. LEGACY COMPONENT DESC: Piping (exhaust)
Condition: Improper/Lack of Maintenance
Due 29 May 2002
Resolved 28 May 2002
Construction/Loadline › Structures
Issued 29 April 2002
Resolved
Crop and renew back to good steel on main deck stairwell leading to mud pit room. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Due 29 May 2002
Resolved 28 May 2002
Deck/Cargo › Ballast
Issued 29 April 2002
Resolved
Crop and renew standpipe vent to number 3 stbd salt water tank, starboard side forward on main deck. LEGACY COMPONENT DESC: Vents
Condition: Improper/Lack of Maintenance
Due 29 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety
Issued 25 July 2001
Resolved
REPLACE MISSING INTERIOR ACCOMODATION DOORS.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Construction/Loadline
Issued 25 July 2001
Resolved
CROP AND RENEW WASTED/HOLED VERTICAL STIFFENERS IN #7S AS MARKED.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Construction/Loadline
Issued 25 July 2001
Resolved
COMPLETE PHASE II SEILODD.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Accommodation/Occupational Safety
Issued 25 July 2001
Resolved
CROP AND RENEW HOLED VENT DUCT (STBD SIDE) FOR MUD PUMP ROOM.
Condition: Unknown
Due 25 July 2001
Resolved 25 July 2001
Electrical
Issued 10 April 2001
Resolved
MARK ALL 110 VOLT EMERGENCY LIGHTING WITH "E".
Condition: Unknown
Due 11 April 2001
Resolved 4 May 2001
Lifesaving
Issued 10 April 2001
Resolved
TEST MUD PIT ROOM PRESSURE ALARM.
Condition: Unknown
Due 11 April 2001
Resolved 4 May 2001
Lifesaving
Issued 10 April 2001
Resolved
PROVIDE CHAFFING GEAR FOR HYDRAULIC FLUID LINE FOR STARBOARD LIFEBOAT MOTOR. - REROUTE HOSE & REDUCE SHARP BENDING ANGLE AND RUBBING AGAINST STRUCTURAL MEMBER.
Condition: Unknown
Due 11 April 2001
Resolved 4 May 2001
Electrical
Issued 10 April 2001
Resolved
PROPERLY SUPPORT NEW ADDED ELECTRICAL WIRINMG IN WAY OF PORT SIDE LIFEBOAT LAUNCHING STATION.
Condition: Unknown
Due 11 April 2001
Resolved 4 May 2001
Construction/Loadline
Issued 10 April 2001
Resolved
PROVIDE ADEQUATE SEAL ON MAIN DECK WX DOORS IN WAY OF GALLEY, ALL MAIN DECKWX TIGHT DOORS FACING DRILL FLOOR.
Condition: Unknown
Due 11 April 2001
Resolved 4 May 2001
Navigation
Issued 10 April 2001
Resolved
CLEAN OBSTRUCTION LIGHT LENSES.
Condition: Unknown
Due 11 April 2001
Resolved 4 May 2001
Accommodation/Occupational Safety
Issued 12 June 2000
Resolved
Provide gauging report for #1, #2, and #3 cement tanks.
Condition: Unknown
Due 12 June 2000
Resolved 12 June 2000
Fire Fighting
Issued 12 April 1999
Resolved
FASTEN SAFETY CHAINS ON FIRE STATION NOZZLES.
Condition: Unknown
Due 19 April 1999
Resolved 19 April 1999
Fire Fighting
Issued 12 April 1999
Resolved
REPLACE BROKEN VALVE ON DISCHARGE OF FIRE PUMP.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Fire Fighting
Issued 12 April 1999
Resolved
HOSE STATION #3 DID NOT OPERATE.
Condition: Unknown
Due 19 April 1999
Resolved 19 April 1999
Lifesaving
Issued 12 April 1999
Resolved
RE-LABEL PAINT LOCKER INSTRUCTIONS
Condition: Unknown
Due 19 April 1999
Resolved 19 April 1999
Unknown
Issued 12 April 1999
Resolved
TEST ALL SAFETY VALVES, TOTAL RIG SHUTDOWN, AND REVERSE POWER RELAYS AT FIRST AVAILABLE OPPORTUNITY.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Electrical
Issued 12 April 1999
Resolved
ENSURE STANDBY GENERATOR HAS SHUTDOWN ALARMS.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Construction/Loadline
Issued 1 May 1998
Resolved
REPLACE OR ATTACH GASKETS ON WATERTIGHT DOORS IN ENGINEERING SPACES PROPERLY.
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Fire Fighting
Issued 1 May 1998
Resolved
REPLACE FIREHOSE AND NOZZLE ON FIRE STA 12.
Condition: Unknown
Due 1 May 1998
Resolved 12 May 1998
Engineering
Issued 1 May 1998
Resolved
POST FUEL TRANSFER PROCEDURES AT FUEL TRANSFER STATION.
Condition: Unknown
Due 1 May 1998
Resolved 12 May 1998
Lifesaving
Issued 1 May 1998
Resolved
REPLACE DEFECTIVE HANDLE ON EYEWASH STATION IN MUDPIT ROOM.
Condition: Unknown
Due 1 May 1998
Resolved 12 May 1998
Lifesaving
Issued 1 May 1998
Resolved
REPLACE LIFEBOAT FALLS ON BOTH LIFEBOATS AND CONDUCT WEIGHT TEST.
Condition: Unknown
Due 1 May 1998
Resolved 1 May 1998
Construction/Loadline
Issued 9 April 1997
Resolved
PROVE PROPER OPERATION OF BILGE PUMP AND MANIFOLD SYSTEM.
Condition: Unknown
Due 9 May 1997
Resolved 15 May 1997
Lifesaving
Issued 9 April 1997
Resolved
INCORPORATE INTO PRACTICE ALL LIFESAVING OPERATIONAL REQUIREMENTS OF THE NEW LIFESAVING REQUIREMENTS OF THE 1996 EDITION OF 46 CFR SUBCHAPTER I-A.
Condition: Unknown
Due 9 June 1997
Resolved 15 May 1997
Documentation
Issued 9 April 1997
Resolved
RESUBMIT AMENDED FIRE CONTROL/SAFETY EQUIPMENT PLAN FOR REVIEW BY [name withheld].
Condition: Unknown
Due 9 April 1997
Resolved 9 April 1997
Construction/Loadline
Issued 9 April 1997
Resolved
COMPLETE WELDING OF OVERHEAD DECK INSERT IN WAY OF PIPE RACK DECK OVER #2 GENERATOR.
Condition: Unknown
Due 9 May 1997
Resolved 15 May 1997
Fire Fighting
Issued 9 April 1997
Resolved
PROVIDE LOSS-OF-VENTILATION ALARM SYSTEM FOR MUD PUMP/MUD PIT ROOM THAT IS WIRED INDEPENDENTLY OF VENTILATION FAN MOTOR CONTROLLERS.
Condition: Unknown
Due 9 April 1997
Resolved 9 April 1997
Electrical
Issued 9 April 1997
Resolved
PROVE PROPER OPERATION OF BOTH SHIP'S SERVICE GENERATORS' HIGH WATER TEMPERATURE ALARMS AND LOW OIL PRESSURE SHUTDOWNS.
Condition: Unknown
Due 9 May 1997
Resolved 15 May 1997
Construction/Loadline
Issued 9 April 1997
Resolved
INSTALL CORRECT TYPE AND SIZE GASKET MATERIAL IN WATERTIGHT DOORS BELOW MAIN DECK; REPLACE LOW DENSITY FOAM WITH HIGH DENSITY RUBBER; REDUCE THICKNESS OF GASKET MATERIAL IN DOORS THAT DO NOT CLOSE.
Condition: Unknown
Due 9 May 1997
Resolved 15 May 1997
Fire Fighting
Issued 9 April 1997
Resolved
PROVIDE CONCISE EASY TO READ INSTRUCTIONS FOR SUCTION/DISCHARGE VALVE LINE UP FOR USE OF PRIMARY FIRE PUMPS/SALT WATER PUMPS AND EMERGENGY FIRE PUMP. (LABEL ALL VALVES; INDICATE ON DIAGRAM)
Condition: Unknown
Due 9 May 1997
Resolved 15 May 1997
Deck/Cargo
Issued 13 June 1996
Resolved
CRANE RECORD BOOK TO BE UPDATED IAW 46CFR109.437
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Construction/Loadline
Issued 13 June 1996
Resolved
MAKE PERMANENT REPAIRS TO TO MAIN DECK PLATING IN WAY OF FRAMES 14 & 15 BELOW STARBOARD CRANE MOUNT.
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Deck/Cargo
Issued 13 June 1996
Resolved
REPAIRS/REPLACEMENT OF STARBOARD CRANE TO BE IN ACCORDANCE WITH 46CFR107.25960 AND TESTED IAW 46CFR107.260
Condition: Unknown
Due 13 June 1996
Resolved 13 June 1996
Construction/Loadline
Issued 13 June 1996
Resolved
CONDUCT SURVEY OF MAT DIRECTLY BELOW FRAMES 14 & 16
Condition: Unknown
Due 31 July 1996
Resolved 17 June 1996
Construction/Loadline
Issued 24 May 1994
Resolved
CONDUCT SWIM-BY EXAM OF LOWER MAT SKIRT AND BOTTOM OF MAT AT NEXT RIG MOVE.
Condition: Unknown
Due 24 May 1994
Resolved 24 May 1994
Construction/Loadline
Issued 29 July 1992
Resolved
CONDUCT VISUAL UNDERWATER SWIM-BY INSPECTION OF MAT BOTTOM AND SCOUR SKIRTING.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Construction/Loadline
Issued 29 July 1992
Resolved
PROVIDE COPY OF ABS AND DIVER UNDERWATER SURVEY REPORTS TO [name withheld], TEXAS.
Condition: Unknown
Due 29 July 1992
Resolved 29 July 1992
Electrical
Issued 11 May 1989
Resolved
MAKE REPAIRS AND OPERABLE THE REVERSE CURRENT RELAYS ON BOTH NOS. 1 & 2 MAIN GENERATORS AND POOF TEST THE SATISFACTORY OPERATION.
Condition: Unknown
Due 11 May 1989
Resolved 11 May 1989
Electrical
Issued 15 August 1988
Resolved
REMOVE THE SYNCBRONZING EQUIPMENT USED FOR PARALLELING THE TWO GENERATORS OR INSTALL REVERSE POWER RELAYS. SWITHBOARD SET UP TO RIM SPLIT BOARD. TWO GENERATORS. COMPLIANCE DATE: 15SEP88
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Lifesaving
Issued 15 August 1988
Resolved
REPLACE DETERIORATED LINE ON LIFE RING LOCATED BY STARBOARD LIFE BOAT. 46 CFR 108.515 COMPLIANCE DATE: 15SEP88
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Unknown
Issued 15 August 1988
Resolved
INADEQUATE MARKINGS FOR EXITS AT ENDS OF LIVING SPACE CORRIDORS. AT PRESENT EXIT SIGNS DO NOT CONTRAST WITH BACKGROUND. 46 CFR 108.153 COMPLIANCE DATE: 15SEP88
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Lifesaving
Issued 15 August 1988
Resolved
COX SWAIN WINDOWS ON BOTH BOATS HAZED OVER. REPLACE OR REPAIR. 46 CFR 107.231(CC) COMPLIANCE DATE: 17SEP88
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Engineering
Issued 15 August 1988
Resolved
REMOVE THE PLASTIC AND BRASS PETCOCKS FROM THE RACOR FUEL FILTER SYSTEM ON ALL DIESEL ENGINES AS NEEDED. INSTALL FLAME SHEILDS WERE PLASTIC BOWLS EXISTS. COMPLIANCE DATE: 15SEP88
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Deck/Cargo
Issued 15 August 1988
Resolved
REPLACE THE RELIEF VALUE ON AIR RECEIVER (NAT BOARD #209388) MISSING HAND RELIEF DEVICE AND ASME NAME PLATE INFO.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Electrical
Issued 15 August 1988
Resolved
CLEAN THE EMERGENCY GENERATOR RADIATOR, FULL AND BLOW BYE OF FOREIGN MATERIAL.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Electrical
Issued 15 August 1988
Resolved
CLEAN EMERGENCY GENERATOR BATTERY TERMINALS.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Electrical
Issued 15 August 1988
Resolved
REPAIR LOW LUBE OIL SHUTDOWN ON EMERGENCY GENERATOR.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Accommodation/Occupational Safety
Issued 15 August 1988
Resolved
REMOVE THE DOUBLERS FROM THE BULK MUD PIPING SYSTEM. INERT GAS BACKING WILL BE ACCEPTED.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Deck/Cargo
Issued 15 August 1988
Resolved
REPLACE RELIEF VALVE ON BULK TANK #16005 #1.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Electrical
Issued 15 August 1988
Resolved
REMOVE THE ON/OFF SWITCH FROM THE GENERAL ALARM DISTRIBUTION PANEL. OLD J 46 CFR 113.25-10
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Documentation
Issued 15 August 1988
Resolved
PROVIDE COPY OF AN APPROVED CLASSIFIED LOCATION PLAN. 46 CFR 110.25-1(K) COMPLIANCE DATE: 15SEP88
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Documentation
Issued 15 August 1988
Resolved
PROVIDE ONE COPY OF AN APPROVE STRUCTURAL FIRE PROTECTION DRAWING FOR THE BARGE.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Electrical
Issued 15 August 1988
Resolved
SERVICE TO PROPER OPERATION OR REPLACE THE GENERAL ALARM FLASHING LIGHTS ASNECESSARY. ADJUST BELLS AS NECESSARY.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Unknown
Issued 15 August 1988
Resolved
STENCIL "REMOTE FUEL SHUT OFF FOR _________" ABOVE VALVES FOR THE MUD PUMP EMD'S, ENERATOR EMD'S AND DRILL FLOOR CAT 399'S.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Electrical
Issued 15 August 1988
Resolved
REMOTE FUEL SHUT DOWN FOR GENERATOR PRIME MOVERS MUST BE LOCATED OUTSIDE THE SPACE SERVED.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Deck/Cargo
Issued 15 August 1988
Resolved
MAKE PERMANENT REPAIRS TO THE #2 CHARGING PUMP (MUD MIX) (UPPER CROSSOVER),PIPING SYSTEM TEMPORARY REPAIRS HAVE BEEN MADE TO REPAIR A LEAK IN THE 90 DEGREES INTERSECTION.
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Deck/Cargo
Issued 15 August 1988
Resolved
MAKE TEMPORARY REPAIRS TO THE MUD PIT DOOR JAMS AS NECESSARY UNTIL SUCH TIME AS PERMANENT REPAIR CAN BE MADE. COMPLIANCE DATE: 15SEP88
Condition: Unknown
Due 15 August 1988
Resolved 15 August 1988
Deck/Cargo
Issued 27 July 1987
Resolved
POST API CRANE HAND SIGNAL CHARTS IN VICINITY OF BOTH CRANES.
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Fire Fighting
Issued 27 July 1987
Resolved
PROVIDE TWO OPERABLE OXYGEN /COMBUSTIBLE GAS INDICATORS ON RIG. THEY MUST BE UL OR FM APPROVED, (THE METER ON BOARD DOES NOT INDICATE SO
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Lifesaving
Issued 27 July 1987
Resolved
CLEAR PASSAGEWAY (IE WALKWAY) TO STBD LIFEBOAT.
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Electrical
Issued 27 July 1987
Resolved
REPLACE RENEWABLE LINK FUSES IN THE GENERAL ALARM SWITCH BOX WITH EXPANDALERENEWABLE FUSE TYPE.
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Accommodation/Occupational Safety
Issued 27 July 1987
Resolved
PROVIDE RELIEF VALVE FOR RIG AIR RECEIVER TANK. CG TO WITNESS TEST OF RELIEF VALVE.
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Fire Fighting
Issued 27 July 1987
Resolved
ANNUAL SERVICING TO BE COMPLETED ON ALL FIXED, SEMI-PORTABLE, AND PORTABLE FIR FIGHTING EXTINQUISHERS.
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Electrical
Issued 27 July 1987
Resolved
MAKE OPERABLE THE GENERAL ALARM BELLS IN THE MUD PIT ROOM.
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Documentation
Issued 27 July 1987
Resolved
PROVIDE A COAST GUARD STAMPED APPROVED OPERATIONS MANUAL ABOARD THE RIG (LATEST EDITION OF MANUAL)
Condition: Unknown
Due 27 July 1987
Resolved 27 July 1987
Unknown
Issued 28 October 1986
Resolved
MAKE THE BLACK MAGIC/SLUGGING PIT DUMP VALVE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 28 October 1986
Resolved 28 October 1986
Construction/Loadline
Issued 28 October 1986
Resolved
MAKE THE #1 CENTERLINE WATER TANK AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 28 October 1986
Resolved 28 October 1986
Construction/Loadline
Issued 28 October 1986
Resolved
CONDUCT UNDERWATER SURVEY OF MAT BOTTOM.
Condition: Unknown
Due 28 October 1986
Resolved 28 October 1986
Unknown
Issued 25 September 1986
Resolved
DRYDOCK VESSEL OR CONDUCT UNDERWATER EXAMINATION PRIOR TO RETURNING RIG TO SERVICE OR RENEWING THE CERTIFICATE OF INSPECTION, WHICHEVER OCCURS FIRST.
Condition: Unknown
Due 25 September 1986
Resolved 25 September 1986
Accommodation/Occupational Safety
Issued 7 August 1986
Resolved
MAKE REPAIRS TO THE MSD AND PLACE IT IN OPERATION PRIOR TO MANNING THE RIG FOR OPERATION.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Lifesaving
Issued 7 August 1986
Resolved
PROVIDE 49 ADDITIONAL LIFE JACKETS PRIOR TO MANNING THE RIG FOR OPERATION. UNTIL THIS ITEM IS COMPLETED THE RIG'S MANNING IS LIMITED TO ONLY 11 PERSONS.
Condition: Unknown
Due 7 August 1986
Resolved 7 August 1986
Deck/Cargo
Issued 29 July 1985
Resolved
INSTALL ONE BATTERY BOX ON EACH CRANE AND INSTALL INSTRUMENT LIGHTING IN EACH CRANE AS PER 46 CFR 108.601B.
Condition: Unknown
Due 29 July 1985
Resolved 29 July 1985
Electrical
Issued 8 August 1984
Resolved
REPAIR OR REPLACE AND TEST THE REVERSE POWER RELAY FOR #1 GENERATOR WITHIN THIRTY (30) DAYS. THE TESTING IS TO BE CONDUCTED IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 8 August 1984
Resolved 8 August 1984
Construction/Loadline
Issued 9 March 1984
Resolved
HAVE BOTTOM OF MATT EXAMINED UPON MOVING OF VESSEL AND PRIOR TO RELOCATING AGAIN IN ACCORDANCE WITH MSO GALVESTON LETTER 27FEB84. THIS ITEM TO BE ACCOMPLISHED TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 9 March 1984
Resolved 9 March 1984
Unknown
Issued 14 October 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU J. STORM XVI, DN638954.
Condition: Unknown
Due 14 October 1983
Resolved 14 October 1983
Unknown
Issued 14 October 1983
Resolved
REMOVE FROM CLASSIFIED LOCATION THE LOW VOLUME AIR COMPRESSORS OR PROVIDE HARD PIPED SUCTION LINES FROM A NON-CLASSIFIED SPACE. PLAN APPROVAL TO BE
Condition: Unknown
Due 14 October 1983
Resolved 14 October 1983
Unknown
Issued 14 October 1983
Resolved
(REQUIREMENT 1 CONTINUED)DONE BY OFFICER IN CHARGE MARINE INSPECTION OFFICENEW ORLEANS, LOUISIANA.
Condition: Unknown
Due 14 October 1983
Resolved 14 October 1983
Unknown
Issued 14 October 1983
Resolved
PROVIDE A LOSS OF VENTILATION ALARM IN THE MUD PIT SPACE IN ACCORDANCE WITH46 CFR 108.175(C)3.
Condition: Unknown
Due 14 October 1983
Resolved 14 October 1983
Deck/Cargo
Issued 6 August 1983
Resolved
HYDROSTATICALLY TEST THE FUEL OIL TRANSFER HOSES AT WORKING PRESSURE. (33 CFR 157)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Unknown
Issued 6 August 1983
Resolved
REMOVE THE LOW PRESSURE AIR COMPRESSORS FROM THE HAZARDOUS LOCATION OF THE MUD PIT ROOM.
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Lifesaving
Issued 6 August 1983
Resolved
PROVIDE ON ADDITIONAL BOAT HOOK. (46 CFR 108.503 (D))
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Construction/Loadline
Issued 6 August 1983
Resolved
ADJUST THE WATERTIGHT DOOR LEADING TO THE PIPE RACK BY THE OFFICE FOR PROPER OPERATION. (46 CFR 108.231)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
PROVIDE SUFFICIENT GENERAL ALARM BELLS/HORNS TO BE HEARD THROUGHOUT MAIN DECK & DRILL FLOOR AND ADJUST GENERAL ALARM BELL IN SHOWER ROOM.
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Unknown
Issued 6 August 1983
Resolved
(REQ. 15 CONTINUED) (46 CFR 113.25)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
PROVIDE EVIDENCE TO SHOW THAT EHT ELECTRICAL SIDE OF THE MATHEY MODEL SURVEYOR II, WIRELINE UNIT IS SUITABLE FOR INSTALLATION IN A HAZARDOUS
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Unknown
Issued 6 August 1983
Resolved
(REQ. 18 CONTINUED) LOCATION. (46 CFR 111.80 & 108.171 0
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
SET AND DEMONSTRATE OVERSPEED TRIPS ON THE EMD ENGINES. (46 CFR 111.10)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
REPAIR AND DEMONSTRATE OPERATION OF THE REVERSE POWER RELAYS. (46 CFR 111.10)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
DEMONSTRATE OPERATION OF THE AUTOMATIC START OF THE EMERGENCY GENERATOR. (46 CFR 112.50/51)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
REPLACE PLASTIC TIE WRAPS ON THE DRILL FLOOR WITH METAL AND TIE WRAP ALL CABLES. (46 CFR 111.60-25)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
REPLACE BOTTOM SIDE EYS FITTING ON DP3 BOX ON DRILL FLOOR AND ON THE LIGHT ABOVE THE HORN AT THE REAR OF THE DRILLERS SHACK.
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
REPLACE OR REMOVE FROM THE HAZARDOUS LOCATIONS; THE MUD LOGGING JUNCTION BOXES ON THE DRILL FLOOR IN MUD PIT ROOM AND AFT BULKHEAD OF STARBOARD
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Unknown
Issued 6 August 1983
Resolved
(REQ. 6 CONTINUED) JACKHOUSE. (46 CFR 111.80)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Unknown
Issued 6 August 1983
Resolved
PROVIDE AUDIBLE OR VISUAL ALARM FOR ADAIR MUD MONITOR. (46 CFR 108.175 (A)(3)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
PROVIDE AN EYS FITTING FOR THE ALARM OVER THE DRILLER'S SHACK. (46 CFR 111.80)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
REPAIR THE START/STOP SWITCHES IN THE MUD PIT ROOM. (46 CFR 11.05-10) (46 CFR 11.05-10)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
CHECK ALL EYS FITTING IN MUD PIT ROOM AND FILL AS NECESSARY. (46 CFR 111. 80)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
MOVE OR MAKE SUITABLE FOR HAZARDOUS LOCATION ALL ELECTRICAL JUNCTION BOXES AND CONTROLLERS WITHIN FIVE (5) FEET OF BOUNDARY OF ALL MUD PIT ROOM DOORS.
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Unknown
Issued 6 August 1983
Resolved
(REQ. 11 CONTINUED) (46 CFR 108.172 & 111.80)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983
Electrical
Issued 6 August 1983
Resolved
ON THE AFT BULKHEAD OF THE STARBOARD JACKHOUSE REMOVE THE SPLICE IN THE WIRING AND PROVIDE EYS FITTING. (46 CFR 108.172)
Condition: Unknown
Due 6 August 1983
Resolved 6 August 1983