MAURY USCG vessel records Sign in
← All vessels

GLOMAR HIGH ISLAND VI

GLOMAR HIGH ISLAND VI is a 1981 mobile offshore drilling unit. The Coast Guard has recorded 34 inspections since 1981, most recently in April 1992, along with 71 deficiencies.

Records from 1981 to 1992. Most recent: inspection, 27 April 1992.

Built
1981
Last inspected
27 April 1992
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-52754

Inspections, by type

…with no type recorded16
Years with a record 12 calendar years (1981–1992)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 34 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it3866 - Regulatory (Subpart C or D), Net Ton
4831 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 34

27 April 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 953745
27 April 1992 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1264410
12 November 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1251400
28 August 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 935254
27 June 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1004613
23 April 1991 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 999928
27 November 1990 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1221812
19 October 1990 Re-Inspection · Drydock Extension
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1211127
5 March 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 916865
13 December 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 932953
30 August 1989 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1041641
10 March 1989 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 897718
2 September 1988 Deficiency Check · Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1208830
14 July 1988 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 898023
31 May 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 886997
31 May 1988 Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1200983
31 August 1987 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1326549
19 February 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1296932
6 February 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1309151
11 November 1985 Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 996663
16 July 1985 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 983199
21 March 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 982170
24 January 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 977743
27 October 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975942
12 July 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282300
23 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971814
14 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273956
8 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963927
15 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969296
20 September 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964797
24 August 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272157
26 July 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964892
30 December 1981 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 965558
3 November 1981 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1272050

Deficiency record · 71

Documentation
Issued 28 August 1991 Resolved
REVISE HAZARDOUS LOCATION PLAN TO INDICATE THE PAINT LOCKER AS A CLASS I _x001C_ DIVISION I AREA._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1991
Resolved 11 October 1991
Electrical
Issued 28 August 1991 Resolved
PROVIDE ARMOR OR [name withheld] FOR CLASS I DIVISION I LOCATIONS IN SHALESHAKER AND PAINT LOCKER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 October 1991
Resolved 12 November 1991
Fire Fighting
Issued 28 August 1991 Resolved
LOOSEN ALL FROZEN FIRE DAMPERS FOR EASY OPERATION._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 28 August 1991 Resolved
REWIRE DRILL FLOOR AREA FOR CLASS I DIVISION I LOCATION OR REVISE HAZARDOUSLOCATION PLANS TO INDICATE DRILL FLOOR AS CLASS I DIVISION II AREA (EXCEPT FOR 5 FEET AROUND ROTATORY TABLE)._x001C_ _x001C_
Condition: Unknown
Due 28 September 1991
Resolved 12 November 1991
Electrical
Issued 28 August 1991 Resolved
CONDUCT TEST OF TOTAL RIG SHUTDOWN AND REMOTE MAIN GENERATOR SHUTDOWNS DURING NEXT RIG MOVE OR AS DRILLING OPERATIONS PERMITS. THE OIM SHALL LOG TEST AND RESULTS IN OFFICIAL VESSEL LOG FOR COAST GUARD REVIEW._x001C_ _x001C_
Condition: Unknown
Due 28 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 28 August 1991 Resolved
REPAIR #2 FUEL OIL TRANSFER PUMP._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 28 August 1991 Resolved
PROVIDE PROPER PURGE ALARM FOR ROSS HILL CONTROL BOX ON STBD BULKHEAD OF DRILL FLOOR TO BE HEARD BY DRILLER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 28 August 1991 Resolved
REPAIR LEAK ON #1 CENTERFUSE UNIT IN MAIN GENERATOR SPACE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 September 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 27 June 1991 Resolved
Provide a copy of the ABS report for the underwater examination and NDT examination of repairs made to the raw water tower and port leg bracing accomplished 15-19 July 91. Send report to MSO Port Arthur.
Condition: Unknown
Due 31 December 1991
Resolved 19 December 1991
Unknown
Issued 23 April 1991 Resolved
Conduct Magnetic Particle NDT of Repairs to Raw Water Tower and Port leg bracing to deck at the Underwater Inspection at the next rig move.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Unknown
Issued 23 April 1991 Resolved
Conduct Underwater Portion of Special Examination in Lieu of Drydocking at next rig move from West Cameron Block 110.
Condition: Unknown
Due 23 April 1991
Resolved 23 April 1991
Unknown
Issued 19 October 1990 Resolved
PROVIDE ONBOARD A CG APPROVED CONSTRUCTION PORTFOLIO
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Unknown
Issued 19 October 1990 Resolved
LABEL ALL CIRCUIT BREAKERS LOCATED WITHIN THE ACCOMODATION SPACE
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Unknown
Issued 19 October 1990 Resolved
ATTACH THE BRAKE RELEASE CABLE TO THE #4 LIFERAFT
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Unknown
Issued 19 October 1990 Resolved
HYDROSTATICALLY TEST 1 SCBA BOTTLE AT EACH FIRE STATION
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Unknown
Issued 19 October 1990 Resolved
REPLACE RING BUOY SMOKE SIGNAL NEAR #1 LIFEBOAT
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Unknown
Issued 19 October 1990 Resolved
PROVIDE ONBOARD 12 HAND HELD PARACHUTE FLARES FOR VESSEL AND PROVIDE PROOF OF PURCHASE
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Unknown
Issued 19 October 1990 Resolved
RENEW LEAKING 4" SEAWATER PIPE IN WORKSHOP OVERHEAD
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Unknown
Issued 19 October 1990 Resolved
REPLACE PLASTIC SIGHT GLASS FOR THE EMERGENCY GENERATOR WITH PYREX
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Unknown
Issued 19 October 1990 Resolved
INSTALL AUTOMATIC SHUT-OFF NOZZLES ON DIESEL OIL FILLER HOSES FOR SCHLUMBERGER & HALLIBURTON UNITS
Condition: Unknown
Due 19 October 1990
Resolved 19 October 1990
Fire Fighting
Issued 30 August 1989 Resolved
REPLACE BROKEN GLASS ON THE CO2 PULL STATIONS.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Deck/Cargo
Issued 30 August 1989 Resolved
OPEN FOR INTERNAL EXAM THE DRILL FLOOR AIR RECEIVER AND THE THREE STARBOARDSIDE BULK TANKS.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Electrical
Issued 30 August 1989 Resolved
REPAIR OR REPLACE BATTERY CHARGER FOR EMERGENCY GENERATOR BATTERIES.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Unknown
Issued 30 August 1989 Resolved
OBTAIN TWO OPERATIONAL OXYGEN AND EXPLOSIVE METERS.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Documentation
Issued 30 August 1989 Resolved
PROVIDE ONBOARD THE ORIGINAL CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Fire Fighting
Issued 30 August 1989 Resolved
REPLACE THE DAMAGED FLEXIBLE LOOPS ON THE MACHINERY SPACE CO2 SYSTEM.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Deck/Cargo
Issued 30 August 1989 Resolved
CONDUCT OPERATIONAL TEST OF SAFETY RELIEF VALVES FOR DRILL FLOOR AIR RECEIVER AND THE THREE STARBOARD BULK TANKS.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Accommodation/Occupational Safety
Issued 30 August 1989 Resolved
INSTALL SCHRAEDER VALVES FOR AIR CUSHION SUPPLY ON SANITARY AND POTABLE WATER TANKS.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Fire Fighting
Issued 30 August 1989 Resolved
REMOVE NON-METALLIC EXPANSION JOINTS ON BOTH FIRE PUMPS IN WAY OF SUCTION AND DISCHARGE LINES AND HARD PIPE OR INSTALL SHOCK MOUNTS ON BOTH PUMPS.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Electrical
Issued 30 August 1989 Resolved
REPAIR AND CONDUCT OPERATIONAL TEST OF EMERGENCY GENERATOR INCLUDING OVER- SPEED SHUTDOWN, LOW LUBE OIL TRIP AND HIGH JACKET WATER ALARM.
Condition: Unknown
Due 30 August 1989
Resolved 30 August 1989
Unknown
Issued 2 September 1988 Resolved
PREPARE AND OPEN MUDPIT DUMP VALVES FOR INTERNAL EXAMINATION BY COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Lifesaving
Issued 2 September 1988 Resolved
REPLACE ONE (1) CRACKED WINDOW AND REPAIR GELCOAT ON FORWARD PORT QUARTER OF #1 CAPSUL.
Condition: Unknown
Due 2 September 1988
Resolved 2 September 1988
Fire Fighting
Issued 31 August 1987 Resolved
PROVIDE ON BOARD TWO OPERABLE OXYGEN AND COMBUSTIBLE GAS METERS.
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Construction/Loadline
Issued 31 August 1987 Resolved
MAKE TEMPORARY REPAIRS TO THE TWO DETERIORATED DOORS BETWEEN THE MUD PUMP ROOM AND THE MUD PIT ROOM.
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Construction/Loadline
Issued 31 August 1987 Resolved
REPLACE THE DETERIORATED DOORS BETWEEN THE MUD PUMP ROOM AND THE MUD PIT ROOM.
Condition: Unknown
Due 31 August 1987
Resolved 31 August 1987
Lifesaving
Issued 11 November 1985 Resolved
MAKE PERMANENT REPAIRS TO THE DAMAGED PORT SIDE LIFERAFT STATION EMBARKATION LADDER.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Construction/Loadline
Issued 11 November 1985 Resolved
MAKE ALL THROUGH HULL FITTINGS AND SEA VALVES INCLUDING ALL PRELOAD TANK DUMP AND MUD PIT DUMP VALVES AVAILABLE FOR INTERNAL INSPECTION BY A MARINE INSPECTOR AT THE NEXT RIG MOVE OR IN ANY CASE NO LATER THAN 24 FEB 86.
Condition: Unknown
Due 11 November 1985
Resolved 11 November 1985
Electrical
Issued 16 July 1985 Resolved
TEST REVERSE POWER RELAY FOR #2 GENERATOR.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Electrical
Issued 16 July 1985 Resolved
REPLACE PRESENT FIXTURES WITH PROPER EXPLOSION PROOF FITTINGS OR PROVIDE PROOF OFUL/FM LISTING.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Accommodation/Occupational Safety
Issued 16 July 1985 Resolved
REPAIR QUARTERS REMOTE VENTILATION SHUTDOWN.
Condition: Unknown
Due 16 July 1985
Resolved 16 July 1985
Construction/Loadline
Issued 24 January 1985 Resolved
RENEW MISSING DOOR CLOSURES FOR MUD PIT ROOM DOORS.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Electrical
Issued 24 January 1985 Resolved
RESECURE BLADE GUARD ON INTAKE FAN FOR MUD PIT ROOM.
Condition: Unknown
Due 24 January 1985
Resolved 24 January 1985
Unknown
Issued 12 July 1984 Resolved
REPAIR OR REPLACE ONE OXYGEN AND EXPLOSIVE METER WITH THE UNDERWRITER'S LABORATORY INCORPORATED LABEL OR THE FACTORY MUTUAL APPROVAL LABEL. 46 CFR 108.497
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Unknown
Issued 12 July 1984 Resolved
THE FOLLOWING DEFICIENCIES PRETAIN TO THE MODU GLOMAR HIGH ISLAND VI, O.N. 633836, AND ARE TO BE COMPLIED BY 12AUG84.
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Electrical
Issued 12 July 1984 Resolved
CLEARLY LABEL THE REMOTE VENTILATION AND FUEL OIL TRANSFER PUMP SHUTDOWNS, LOCATED ON THE DECKHOUSE AND DRILL FLOOR, 46 CFR 111.103
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Unknown
Issued 12 July 1984 Resolved
REPAIR THE #1 FUEL OIL TRANSFER PUMP SHAFT PACKING. 46 CFR 107.231
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Electrical
Issued 12 July 1984 Resolved
REPAIR THE FORKLIFT CHARGING SYSTEM, 46 CFR 108.615.
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Unknown
Issued 12 July 1984 Resolved
MARK THE FORKLIFT WITH ITS LIFTING CAPACITY, 46 CFR 109.533
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Unknown
Issued 12 July 1984 Resolved
MARK THE FORKLIFT WITH ITS LIFTING CAPACITY, 46 CFR 109.533
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Electrical
Issued 12 July 1984 Resolved
REPAIR THE LOSS OF PURGE AIR ALARM TO THE DRILLERS CONSOLE STROKE COUNTER. 46 CFR 111.92
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Electrical
Issued 12 July 1984 Resolved
PROVIDE APPROVED (UL,FM,CSA) SWITCH BOXES ON THE AFT BULKHEAD OF THE DRILL FLOOR, 46CFR 111.92
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Unknown
Issued 12 July 1984 Resolved
PROVIDE A VENT SCREEN ON THE DIRTY OIL AND #13 FUEL OIL TANKKS. 46 CFR 58.50-85
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Unknown
Issued 12 July 1984 Resolved
PROVIDE FIXED FUEL OIL CONTAINMENT TO THE STARBOARD DECK FILL CONNECTION. 33 CFR 155.320
Condition: Unknown
Due 12 July 1984
Resolved 12 July 1984
Unknown
Issued 14 July 1983 Resolved
(REQUIRMENT 10 CONTINUED) AND TAPED CABLE RUNNING FROM THE DRILL FLOOR TO THE CANTILEVER DECK 46 CFR 111.92-11.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Electrical
Issued 14 July 1983 Resolved
INSTALL EXPLOSION PROOF ELECTRICAL CONNECTIONS UNDER THE DRILL FLOOR STARBOARD SIDE FROM THE LOGGING UNIT AND ALSO RERUN OR REMOVE THE SPLICED
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Navigation
Issued 14 July 1983 Resolved
PROVIDE A SHIP'S WHISTLE - COLREGS (1972) RULE 3 AND ANNEX I.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Fire Fighting
Issued 14 July 1983 Resolved
PROVIDE GENERAL ALARM BELL UNDER CANTILEVER DECK AND SCR STOREROOM, 46 CFR 113.25-10C.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Construction/Loadline
Issued 14 July 1983 Resolved
CONDUCT UNDERWATER SURVEY OF SPUD CANS AT NEXT RIG MOVE BUT NO LATER THAN 14JAN84.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Documentation
Issued 14 July 1983 Resolved
MANNING REDUCED TO SIXTY (60) TOTAL PASSENGERS ON BOARD UNTIL SUCH TIME AS ALL INFLATABLE LIFERAFTS ARE RETURNED ABOARD 46 CFR 108.505.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Unknown
Issued 14 July 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, GLOMAR HIGH ISLAND VI DN633836.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Construction/Loadline
Issued 14 July 1983 Resolved
PROVIDE NON-SKID ON HELIPORT SURFACE, 46 CFR 108.233.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Fire Fighting
Issued 14 July 1983 Resolved
PROVIDE ONE ADDITIONAL OXYGEN AND EXPLOSION METER FOR FIREMAN'S OUTFIT, 46 CFR 108.497.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Lifesaving
Issued 14 July 1983 Resolved
PROVIDE ONE 36 INCH SEA ANCHOR FOR EACH SURVIVAL CAPSULE, 46 CFR 108.503.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Lifesaving
Issued 14 July 1983 Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE LINE THROWING GUN: TWO (2) BUOYANT ROCKETS, ONE (1) SERVICE LINE, ONE (1) AUXILIARY LINE OF 1500 FEET.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Unknown
Issued 14 July 1983 Resolved
(REQUIREMENT 4 CONTINUED) 46 CFR 108.517.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Navigation
Issued 14 July 1983 Resolved
PROVIDE ONE (1) BLACK BALL DAY SHAPE - 1972 COLREGS ANNEX I.
Condition: Unknown
Due 14 July 1983
Resolved 14 July 1983
Unknown
Issued 15 June 1983 Resolved
THE FOLLOWING DEFICIENCY PERTAINS TO THE VESSEL GLOMAR HIGH ISLAND VI, DN633836.
Condition: Unknown
Due 15 July 1983
Resolved 15 June 1983
Lifesaving
Issued 15 June 1983 Resolved
MAKE PERMANENT REPAIRS TO #2 LIFE CAPSULE. WHILE CAPSULE IS REMOVED FROM RIG TOTAL PERSONS ALLOWED IS REDUCED TO FIFTY (50).
Condition: Unknown
Due 15 July 1983
Resolved 15 June 1983
Unknown
Issued 15 June 1983 Resolved
SUBMIT CG2692 REPORT FORMS FOR THE INJURED CREWMEN RESULTANT FROM THE CASUALTY RESULTANT TO LB #2 ON 14JUN83.
Condition: Unknown
Due 15 June 1983
Resolved 15 June 1983
Unknown
Issued 30 December 1981 Resolved
EFFECT PERMANENT REPAIRS TO THE STARBOARD CAPSULE IN WAY OF THE OUTBOARD ROOF MOUNTING PAD.
Condition: Unknown
Due 30 December 1981
Resolved 30 December 1981
Unknown
Issued 30 December 1981 Resolved
ADJUST THE STARBOARD CAPSULE CRADLING POINTS TO FACILITATE PROPER CRADLING OF THE CAPSULE.
Condition: Unknown
Due 30 December 1981
Resolved 30 December 1981

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.