Records from 1985 to 2004. Most recent: inspection, 15 September 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 44
15 September 2004
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 2196228
16 January 2003
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1731266
5 September 2002
Re-Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 1671381
8 June 2001
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1431049
8 February 2001
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1379322
21 June 2000
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1381936
20 September 1999
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1195531
23 July 1999
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1365299
22 January 1999
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1397060
23 August 1998
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 124345
3 June 1998
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1126900
7 May 1998
Damage Survey
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1124209
26 June 1997
MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 777210
16 January 1997
MARPOL Annex V Examination · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1099931
13 January 1997
Drydock Extension
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1098064
18 July 1996
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1084551
11 June 1996
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1087137
8 June 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1188376
30 May 1995
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 874384
27 March 1995
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1139333
28 November 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1153597
25 October 1994
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1178119
18 April 1994
Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 860190
29 March 1994
Re-Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1169159
16 March 1993
Deficiency Check · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 835178
4 March 1993
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1146500
18 March 1992
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1258193
9 March 1992
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1257741
18 June 1991
Administrative
Administrative · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1044873
12 March 1991
Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 924753
21 March 1990
Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1293966
15 March 1990
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1244719
21 March 1989
COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1036181
14 March 1989
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1344304
24 March 1988
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 992454
21 March 1988
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 992453
14 July 1987
Deficiency Check
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1324134
27 March 1987
Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1021392
18 March 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1324856
19 November 1986
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1329091
26 March 1986
COI Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 999396
20 March 1986
Credit Drydock
Administrative · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 999395
27 March 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 982006
20 March 1985
Type not recorded
No type recorded · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1287451
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 5 September 2002
Resolved
Provide proof of servicing of fixed fire fighting.
Condition: Unknown
Due 13 September 2002
Resolved 12 September 2002
Construction/Loadline › Hull
Issued 5 September 2002
Resolved
Make proper repairs to wood members in engine room. Furring noted in framing. LEGACY COMPONENT DESC: Transverse Frame
Condition: Unknown
Action required: 705 - Other - as specified
Due 13 September 2002
Resolved 12 September 2002
Lifesaving › Lifebuoys
Issued 5 September 2002
Resolved
Replace Ring Buoy.
Condition: Unknown
Due 13 September 2002
Resolved 12 September 2002
Documentation › Logs/Records
Issued 5 September 2002
Resolved
Provide proof of enrollment in Drug Consortium. LEGACY COMPONENT DESC: Drug Test Records
Due 13 September 2002
Resolved 9 September 2002
Resolution: Copy of enrollment in the Maritime Consortium, Inc. faxed to this office.
Pollution Prevention/Response › Prevention Equipment
Issued 5 September 2002
Resolved
Provide means of securing MSD Valve and label "Do not open in U.S. Waters" LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper Installation
Due 13 September 2002
Resolved 12 September 2002
Navigation › Piloting/Steering
Issued 5 September 2002
Resolved
Provide compass deviation card. LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Unknown
Due 13 September 2002
Resolved 12 September 2002
Fire Fighting
Issued 8 June 2001
Resolved
Service Fixed Firefighting prior to Aug 31, 2001.
Condition: Unknown
Due 31 August 2001
Resolved 5 September 2002
Resolution: rewrote requirement on 05SEP02.
Construction/Loadline
Issued 8 June 2001
Resolved
Make proper repairs to wood members in engine room with furring framing.
Condition: Unknown
Due 2 July 2001
Resolved 5 September 2002
Resolution: rewrote requirement on 05SEP02.
Navigation
Issued 21 June 2000
Resolved
PROVIDE LEFT RUDDER STOP FOR STEERING GEAR TO PREVENT IMPACT W/ FUEL TANK._x001C__x001C_ _x001C_ _x001C_
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Lifesaving
Issued 21 June 2000
Resolved
RENEW ALL LINES/PAINTER ON LIFEFLOAT.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Documentation
Issued 21 June 2000
Resolved
PROVIDE FCC OPERATOR'S 5 YEAR PERMIT FOR [name withheld].
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Construction/Loadline
Issued 21 June 2000
Resolved
MAKE ENGINEROOM BULKHEAD WATERTIGHT.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Fire Fighting
Issued 23 July 1999
Resolved
Install fixed fire extinguishing system in accordance with 46 CFR 181.400.
Condition: Unknown
Due 23 July 1999
Resolved 23 July 1999
Electrical
Issued 22 January 1999
Resolved
PROVIDE PROPER BATTERY BOXES IN MACHINERY SPACE.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Construction/Loadline
Issued 22 January 1999
Resolved
PROVIDE VAPOR TIGHT SEAL IN WAY OF GEN SPACE FWD HATCH.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Construction/Loadline
Issued 22 January 1999
Resolved
PROVIDE PROPER REPAIR IN WAY OF CRACKED WELDS ON DIVE PLATFORM.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Engineering
Issued 22 January 1999
Resolved
REPLACE MISSING AND CORRODED EXHAUST HOSE CLAMPS THROUGH-OUT BOTH EXHAUST SYSTEMS.
Condition: Unknown
Due 22 January 1999
Resolved 22 January 1999
Lifesaving
Issued 11 June 1996
Resolved
REPLACE SNAPS ON LIFE PRESERVERS.
Condition: Unknown
Due 18 June 1996
Resolved 19 July 1996
Electrical
Issued 11 June 1996
Resolved
PROVIDE COVER FOR BATTERY BOX.
Condition: Unknown
Due 11 June 1996
Resolved 19 July 1996
Accommodation/Occupational Safety
Issued 11 June 1996
Resolved
REPLACE BROKEN WINDOW IN WAY OF HOUSE (CENTER).
Condition: Unknown
Due 11 July 1996
Resolved 19 July 1996
Electrical
Issued 11 June 1996
Resolved
PROVE RACOR FUEL FILTER FOR GEN SET MEETS FLAME IMPINGMENT SPECS. OR REPLACE WITH PROPER TYPE.
Condition: Unknown
Due 11 July 1996
Resolved 19 July 1996
Unknown
Issued 29 March 1994
Resolved
CONDUCT AN UNDERWAY RIDE WITH A USCG MARINE INSPECTOR ON BOARD TO PROVE THEHULL IS SOUND AND TIGHT.
Condition: Unknown
Due 29 March 1994
Resolved 29 March 1994
Engineering
Issued 29 March 1994
Resolved
MAKE PERMANENT REPAIRS TO EXHAUST LEAK IN ENGINE ROOM (PORT EXHAUST).
Condition: Unknown
Due 29 April 1994
Resolved 11 April 1994
Navigation
Issued 29 March 1994
Resolved
PROVIDE CURRENT DEVIATION TABLE.
Condition: Unknown
Due 29 April 1994
Resolved 11 April 1994
Fire Fighting
Issued 29 March 1994
Resolved
HYDRO TEST TWO B-II FIRE EXTINGUISHERS IN ACCOMMODATIONS.
Condition: Unknown
Due 29 April 1994
Resolved 11 April 1994
Construction/Loadline
Issued 16 March 1993
Resolved
Provide a fitting with a single hose to the suction side of the water washdown pump (12V) from the sea valve.
Condition: Unknown
Due 22 March 1993
Resolved 22 March 1993
Lifesaving
Issued 16 March 1993
Resolved
Provide 15 pigtails on the buoyant apparatus prior to carrying passengers.
Condition: Unknown
Due 22 March 1993
Resolved 22 March 1993
Electrical
Issued 16 March 1993
Resolved
Hard wire the 120V bilge pump to the electrical witha switch.
Condition: Unknown
Due 22 March 1993
Resolved 22 March 1993
Navigation
Issued 18 March 1992
Resolved
OBTAIN UPDATED RULES OF THE ROAD AS PER 33CFR 88.05
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Fire Fighting
Issued 18 March 1992
Resolved
INSTALL CG APPROVED MARINE TYPE BII EXTINGUISHER.
Condition: Unknown
Due 30 March 1992
Resolved 30 March 1992
Lifesaving
Issued 18 March 1992
Resolved
INSTALL HANKS AND LIFE LINE ON BUOYANT APPARATUS AS PER 46CFR 160.010.3
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Lifesaving
Issued 18 March 1992
Resolved
PROVIDE THREE ADULT TYPE 1 PFD. TOTAL PASSENGERS LIMITED BY THREE ON ALL ROUTES.
Condition: Unknown
Due 26 March 1992
Resolved 26 March 1992
Electrical
Issued 12 March 1991
Resolved
FABRICATE AND INSTALL TWO(2) BATTERY BOXES. ONE FOR GENERATOR START BATTERYIN GENERATOR SPACE, AND ONE FOR FOUR BATTERIES IN ENGINE SPACE TWO OF WHICHARE MAIN ENG. START AND TWO ARE FOR ELECTRONICS._x001C_ _x001C_
Condition: Unknown
Due 12 March 1991
Resolved 12 March 1991
Fire Fighting
Issued 27 March 1987
Resolved
PROVIDE ONE ADDITIONAL B-II PORTABLE FIRE EXTINGUISHER FOR THE ACCOMMODATION SPACE. TOTAL B-II REQUIRED: 3.
Condition: Unknown
Due 27 March 1987
Resolved 27 March 1987