MAURY USCG vessel records Sign in
← All vessels

ENSCO 98

ENSCO 98 is a 1977 mobile offshore drilling unit. The Coast Guard has recorded 122 inspections since 1981, most recently in March 2008, along with 192 deficiencies and 5 casualty investigations between 2004 and 2008.

Records from 1981 to 2008. Most recent: inspection, 23 March 2008.

Built
1977
Last inspected
23 March 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8753574 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WCE3778
Flag
UNITED STATES
366929640 (licence lapsed)
Maury page id
psix-52780

Inspections, by type

…with no type recorded37
Years with a record 28 calendar years (1981–2008)
The 122 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1389 - Convention (Subpart B), Net Ton
4631 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCE3778MMSI 366929640 · expired · compulsorily equipped · granted 5 March 2004, cancelled 10 May 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 122

23 March 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3381980
17 January 2008 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3131990
21 April 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2924322
13 February 2007 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2871403
6 February 2007 Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2868348
23 August 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2786763
14 August 2006 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2786725
15 November 2005 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2516133
27 July 2005 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2418280
6 January 2005 Deficiency Check · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2249945
1 March 2004 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2015907
19 February 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2012926
30 October 2003 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1963332
11 August 2003 Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1925016
20 February 2003 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1747072
10 February 2003 Construction Oversight · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1742221
21 October 2002 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1710637
8 January 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1476464
7 January 2002 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1475659
18 November 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075887
20 September 2001 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1073983
22 June 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066983
7 May 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 133776
6 January 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 825405
28 July 2000 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1384538
29 June 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 820132
14 June 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 819242
1 June 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1050690
31 May 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1050684
12 April 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 816773
28 January 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 815281
14 January 2000 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1381777
10 October 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 144636
8 October 1999 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 892085
2 June 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 185812
5 May 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1127225
5 January 1999 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 811138
23 December 1998 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808105
7 December 1998 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1466580
16 October 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 802153
21 August 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 802446
7 August 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1130945
25 June 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 793552
29 April 1998 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1123793
9 January 1998 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1364535
28 October 1997 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1406203
8 July 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 777446
8 May 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1099844
11 December 1996 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1438520
6 September 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 944457
17 July 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1090165
18 March 1996 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1077555
15 January 1996 Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1390185
12 October 1995 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392313
19 September 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 874365
16 August 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417818
26 July 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 883614
17 January 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1145467
16 December 1994 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1443528
19 July 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 869578
21 January 1994 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 852772
21 December 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1160125
20 December 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1159414
8 October 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 961641
1 September 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1138067
22 June 1993 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1362804
5 February 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 136064
13 January 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 112885
10 January 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1162215
31 December 1992 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1399800
4 December 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 172033
11 February 1992 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 955726
17 December 1991 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 949921
29 October 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1250317
23 September 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314227
17 July 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 937271
11 July 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 934784
19 June 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217080
31 May 1991 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 927957
28 May 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 927899
14 May 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 901541
17 April 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 917383
1 April 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1240675
11 March 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 902649
7 March 1991 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1235645
25 January 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1212230
11 July 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1225877
3 July 1990 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1237861
15 April 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912314
23 March 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217227
16 March 1990 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217392
25 January 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917960
12 December 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920976
28 November 1989 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216755
4 October 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914339
31 August 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1347542
26 May 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 969704
25 January 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1351773
19 May 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1042313
21 April 1988 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1341489
2 October 1987 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317194
8 June 1987 Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008584
12 March 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015758
3 February 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1033944
3 February 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1324980
29 April 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989612
3 March 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 999632
27 February 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306676
5 November 1985 Examination of Repairs
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301254
4 November 1985 Examination of Repairs
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1305797
3 August 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1296289
14 July 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300524
7 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289217
16 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283025
21 February 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278945
21 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277444
8 February 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965988
8 February 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274745
2 November 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968577
3 September 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277247
20 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275342
26 February 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973829

Deficiency record · 192

Fire Fighting › Fire Main › Condition
Issued 6 January 2005 Resolved
Repair hole in fire main in the vicinity of the #2 fire pump.
Condition: Unknown
Due 20 January 2005
Resolved 11 January 2005
Resolution: Fire main piping was renewed and hydro tested. All sat.
Engineering › Fuel Oil Storage/Transfer System
Issued 21 October 2002 Resolved
For completion during SEILOD PHASE II - Diesel fuel tank #20 - Gauge bottom deck plating. Renew wasted sounding tube. Examine weld caps & reweld missing caps to provide 1/16" cap. LEGACY COMPONENT DESC: Tank
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 13 June 2003
Construction/Loadline › Penetrations
Issued 21 October 2002 Resolved
For completion during SEILOD Phase II - #30 void: Gauge bottom deck plating. Renew sea suction strainer. Gauge bottom sides of sea chest. Prove watertight integrity for hatch. Open sea valve for inspection.
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 13 June 2003
Construction/Loadline › Structures
Issued 21 October 2002 Resolved
For completion during SEILOD Phase II - #12 void: Install light covers & guards & provide plugs for junction boxes. Renew ladder. Renew bilge suction screen. Weld underside of hatch cover plate. Weld underside of pipe penetration. Remove & plug blowout line on mud pump 8" drain piping.
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 13 June 2003
Construction/Loadline › Structures
Issued 21 October 2002 Resolved
For completion during SEILOD Phase II - #9 preload tank: Repair hole on deck IWO quarters. LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 13 June 2003
Construction/Loadline › Structures
Issued 21 October 2002 Resolved
For completion during SEILOD Phase II - #2 preload tank: Renew leaking seawater piping from deep-well tower.
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 13 June 2003
Construction/Loadline › Structures
Issued 21 October 2002 Resolved
For completion during SEILOD Phase II - #8 preload tank: Gauge bottom plating IWO dump valve piping. Renew wasted flange plate at frame 9/inner perimeter bulkhead at overhead.
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 13 June 2003
Construction/Loadline › Structures
Issued 21 October 2002 Resolved
For completion during SEILOD Phase II - #22 preload tank: Gauge & renew as necessary - stiffeners IWO inboard ladder at leg well.
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 13 June 2003
Construction/Loadline › Structures
Issued 21 October 2002 Resolved
For completion during SEILOD Phase II - #27 void: Replace clamps for mud piping support brackets. Effect permanent repairs to soft-patched fire main piping.
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 13 June 2003
Engineering › Pressure Vessel
Issued 13 December 2001 Resolved
Complete internal exam/NDT of pressure vessels. Provide NDT aand U1A reports/sheets to [name withheld] COMPONENT DESC: NDT/U1A
Due 13 January 2002
Resolved 7 January 2002
Resolution: PATMS attended rig 01/07/2002, ENSCO POC to send reports and sheets to MORMS for vsl file.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 December 2001 Resolved
Remove from deck and properly support power cable to temp water well.
Condition: Improper Installation
Due 15 December 2001
Resolved 13 December 2001
Resolution: Power cable was properly installed.
Construction/Loadline
Issued 28 July 2000 Resolved
Reweld/repair broken and/or wasted main deck preload dump valve reach rod packing glands (restore watertight integrity).
Condition: Unknown
Due 28 July 2000
Resolved 28 July 2000
Construction/Loadline
Issued 28 July 2000 Resolved
Conduct ultrasonic (UT) gauging in following areas and crop and renew hull plating as necessary: no. 26 drill water tank lower leg well plating (wasted through); directly underneath all preload tank stripping line suctions (completely wasted through in no. 2 preload tank).
Condition: Unknown
Due 28 July 2000
Resolved 28 July 2000
Construction/Loadline
Issued 28 July 2000 Resolved
Complete Phase II (U/W critical leg-to-can weld inspection and diver swim- by) of Special Examination in Lieu of Drydocking (SEILODD) upon leaving current contract at West Delta Block 30.
Condition: Unknown
Due 28 July 2000
Resolved 28 July 2000
Lifesaving
Issued 14 January 2000 Resolved
Make repairs to both stbd and port lifeboats where fiberglass on deck is deteriorated.
Condition: Unknown
Due 14 January 2000
Resolved 14 January 2000
Construction/Loadline
Issued 7 December 1998 Resolved
REMOVE CRATES AND DRUMS STORED OVER THE BILGE POCKET IN THE SACK ROOM SO THAT THERE WILL BE ACCESS TO THE SUMP.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Construction/Loadline
Issued 7 December 1998 Resolved
PLUG THROUGH HOLES IN BULKHEAD CONNECTING THE MUD PIT ROOM AND THE MUD PUMPROOM.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Lifesaving
Issued 7 December 1998 Resolved
REPAIR/REPLACE EYE WASH STATIONS ON DRILL FLOOR AND OUTSIDE MUD PIT ROOM.
Condition: Unknown
Due 7 December 1998
Resolved 7 December 1998
Electrical
Issued 7 December 1998 Resolved
REPAIR E-LIGHT ON DRILL FLOOR
Condition: Unknown
Due 7 December 1998
Resolved 10 December 1998
Electrical
Issued 7 December 1998 Resolved
REPAIR E-LIGHT IN 2ND FLOOR PASSAGEWAY
Condition: Unknown
Due 7 December 1998
Resolved 10 December 1998
Electrical
Issued 7 December 1998 Resolved
PLACE A PLUG IN OPENING OF JUNCTION BOX FOR THE EMERGENCY GENERATOR JUST AFT OF THE GENERATOR HOUSE.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Construction/Loadline
Issued 7 December 1998 Resolved
PLUG THROUGH HOLES THROUGH THE BULKHEAD CONNECTING THE MUD PIT ROOM AND THESTORAGE ROOM.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Lifesaving
Issued 7 December 1998 Resolved
REPLACE FIRST AID KITS IN ALL 3 LIFEBOATS
Condition: Unknown
Due 7 December 1998
Resolved 10 December 1998
Electrical
Issued 7 December 1998 Resolved
REMOVE DEAD-END WIRING LOCATED ON THE PORT AFT SECTION OF THE DRILL FLOOR JUST ABOVE A GAS DETECTOR.
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Engineering
Issued 7 December 1998 Resolved
LABEL FUEL XFER HOSE WITH MAWP AND "OIL SERVICE".
Condition: Unknown
Due 15 December 1998
Resolved 15 December 1998
Construction/Loadline
Issued 28 October 1997 Resolved
CONDUCT PHASE II OF SEILODD (SPUD CANS & LEGS).
Condition: Unknown
Due 28 October 1997
Resolved 28 October 1997
Lifesaving
Issued 11 December 1996 Resolved
CONDUCTED WEIGHT TEST OF ALL LIFEBOATS AND LIFERAFT DAVIT.
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Lifesaving
Issued 11 December 1996 Resolved
SUPPLY PROOF OF NEW CABLES BEING INSTALLED OM ALL THREE LIFEBOATS STATIONS AND LIFERAFT DAVIT.
Condition: Unknown
Due 27 December 1996
Resolved 27 December 1996
Fire Fighting
Issued 18 March 1996 Resolved
REVISE AND RESUBMIT FOR COAST GUARD APPROVAL FIRE CONTROL PLAN.
Condition: Unknown
Due 18 March 1996
Resolved 18 March 1996
Accommodation/Occupational Safety
Issued 15 January 1996 Resolved
INSTALL MISSING VALVE HANDLE TO NO.1 FRESH WATER PUMP.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Electrical
Issued 15 January 1996 Resolved
REPAIR BROKEN DOOR TO C.B. LC-1 LOAD CENTER 120/V AIR COMPRESSOR ROOM.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Electrical
Issued 15 January 1996 Resolved
REPAIR C.B. PANEL LC-4 LOAD CENTER 208/V AIR COMPRESSOR ROOM WIRE FITTING TO BOX.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
FREE-UP RUSTED/FROZEN HOSE RACKS FOR BOTH FIRE STATIONS ON HELO DECK.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
REPAIR FIRE EXTINGUISHER NO.42 NOZZLE HANDLE-STIFF.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
REPAIR FIRE EXTINGUISHER NO.39 NOZZLE HANDLE-STIFF.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
REPLACE PORTSIDE HELO DECK FIRE HOSE.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Lifesaving
Issued 15 January 1996 Resolved
REPLACE LINE ON LIFE RING ON PORT BOW.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Lifesaving
Issued 15 January 1996 Resolved
REPLACE LINE TO WATERLIGHT ON LIFE RINGS AT STARBOARD BOW AND BY STARBOARD CRANE.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Deck/Cargo
Issued 15 January 1996 Resolved
PROVIDE CRANE SERVICING REPORT.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
REPAIR FIRE STATION 14 VALVE LEAK.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Lifesaving
Issued 15 January 1996 Resolved
CLEAN OR REPLACE ALL WINDOWS IN LIFE CAPSULE NO.1 AND NO.2.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Electrical
Issued 15 January 1996 Resolved
LABEL WITH "E" ALL EMERGENCY LIGHTS TO LIFE CAPSULES NO.1 AND NO.3 EMBARKATION AREAS.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
CROP AND RENEW WASTED FIREMAIN PIPING PORTSIDE OF HELO DECK.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Lifesaving
Issued 15 January 1996 Resolved
REPAIR INSUFFICIENT WATER PRESSURE TO EYE WASH/SHOWER STATION BY FIRE EXTINGUISHER NO.39.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Electrical
Issued 15 January 1996 Resolved
REPAIR/REPLACE MISSING EMERGENCY LIGHT TO SCR SPACE.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
STENCIL STATION NUMBERS ON BOTH HELO DECK FIRE STATIONS AND ON BOTH FOAM STATIONS BY BOW LEG.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
CROP AND RENEW WASTED COLLAR ON PORTSIDE FOAM STATION BY BOW LEG.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
REPLACE ALL FACE PIECES TO ALL FIREMAN'S OUTFITS.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Lifesaving
Issued 15 January 1996 Resolved
REPLACE THE FOLLOWING LIFE RINGS: A) BY NO.4 CEMENT TANK AND B) PORTSIDE OFCANTILEVER.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
REPAIR LEAK TO FIRE STATION NO.13 NOZZLE.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Electrical
Issued 15 January 1996 Resolved
REMOVE DEAD-ENDED WIRE OVER DRILL WATER PUMPS AT CABLE RUN BY LIGHT FIXTURE.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
REPAIR LEAK TO FIRE STATION 11 AT VALVE STEM.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Documentation
Issued 15 January 1996 Resolved
UPDATE FIRE CONTROL PLAN AND RESUBMIT TO PATMS FOR APPROVAL.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
FLUSH FIRE MAIN SYSTEMS OF ALL DEBRIS.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Lifesaving
Issued 15 January 1996 Resolved
REPLACE ALL WINDOWS IN LIFE CAPSULE NO.3.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Fire Fighting
Issued 15 January 1996 Resolved
BUILD UP WASTED WELD ON WASTED FIREMAIN PIPING STARBOARD SIDE OF HELO DECK.
Condition: Unknown
Due 15 February 1996
Resolved 5 February 1996
Construction/Loadline
Issued 12 October 1995 Resolved
REEXAMINE INDICATIONS FOUND DURING UNDERWATER INSPECTION 12 JULY 1995 ON STBD LEG CHORD TO CAN CONNECTIONS DURING NEXT RIG MOVE.
Condition: Unknown
Due 12 October 1995
Resolved 12 October 1995
Construction/Loadline
Issued 16 August 1995 Resolved
COMPLETE UNDERWATER PORTION OF SEILODD AS PER APPROVED PROCEDURES, AND SUBMIT FINAL NDT AND VIDEO REPORT TO [name withheld] PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 16 August 1995
Resolved 16 August 1995
Construction/Loadline
Issued 22 June 1993 Resolved
COMPLETE UNDERWATER PORTION OF SEILODD INSPECTION AS PER [name withheld] LETTER DATED 21JUN93, TO BE COMPLETED PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 22 June 1993
Resolved 22 June 1993
Construction/Loadline
Issued 31 December 1992 Resolved
REPACK AND INSTALL STUFFING TUBES AS NECESSARY IN STBD BULKHEAD OF MUDPIT WHERE WIRES, ETC., PENETRATE.
Condition: Unknown
Due 22 February 1993
Resolved 22 February 1993
Electrical
Issued 31 December 1992 Resolved
RENEW GOOBE FOR LIGHT ON HELO DECK.
Condition: Unknown
Due 22 February 1993
Resolved 22 February 1993
Electrical
Issued 31 December 1992 Resolved
REPAIR EMERGENCY LIGHT ON FWD PORT WALL OF GENERATOR ROOM.
Condition: Unknown
Due 22 February 1993
Resolved 22 February 1993
Construction/Loadline
Issued 31 December 1992 Resolved
RENEW GASKET IN WATERTIGHT DOOR BETWEEN HALON STORAGE ROOM AND MUDPUMP ROOM.
Condition: Unknown
Due 22 February 1993
Resolved 22 February 1993
Navigation
Issued 31 December 1992 Resolved
REPOSITION NAVIGATION LIGHTS TO PROPER REQUIRED ANGLES.
Condition: Unknown
Due 22 February 1993
Resolved 22 February 1993
Electrical
Issued 31 December 1992 Resolved
REPAIR EMERGINCY LIGHT IN MAIN DECK CHANGE ROOM AND OUTSIDE SECONDARY GALLEY.
Condition: Unknown
Due 22 February 1993
Resolved 22 February 1993
Engineering
Issued 31 December 1992 Resolved
REMOVE ALL PUSH-ON TYPE FUEL LINES ON EMERGENCY GENERATOR AND REPLACE WITH APPROVED SELF EXTINGUSHING TYPE HOSES.
Condition: Unknown
Due 22 February 1993
Resolved 22 February 1993
Engineering
Issued 17 December 1991 Resolved
REPLACE THE #3 HOT WATER HEATER RELIEF VALVE WITH ONE SET AT OR BELOW 100 PSI/210 DEG F. 46 CFR 53.01-10/53.05-1.
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Construction/Loadline
Issued 17 December 1991 Resolved
RENEW GASKET TO MAIN DOOR IN #3 LIFEBOAT. 46 CFR 107.231
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Electrical
Issued 17 December 1991 Resolved
MAKE STERN LIGHT EXPLOSION PROOF OR MOVE MORE THAN FIVE FEET FROM HAZARDOUSLOCATION. IF LOCATION ALTERED ENSURE COMPLIANCE WITH COLREGS. 46 CFR 108.173.
Condition: Unknown
Due 17 December 1991
Resolved 17 December 1991
Electrical
Issued 19 June 1991 Resolved
INSTALL LIGHTING FROM EMERGENCY CIRCUIT TO ILLUMINATE LIFERAFT EMBARKATION DECK TO THE WATERS EDGE.
Condition: Unknown
Due 19 June 1991
Resolved 19 June 1991
Lifesaving
Issued 19 June 1991 Resolved
REVISE FIRE CONTROL PLAN TO SHOW THE INSTALLATION OF THE LIFERAFTS AND DELETION OF THE LIFEFLOATS.
Condition: Unknown
Due 19 June 1991
Resolved 19 June 1991
Lifesaving
Issued 1 April 1991 Resolved
PROVIDE ONBOARD AND INSTALL APPROVED DAVIT LAUNCED LIFERAFTS. AS PER MVI_x001C_ DIST LTR, 16711/19 0213V DTD 5APR88.
Condition: Unknown
Due 1 April 1991
Resolved 1 April 1991
Fire Fighting
Issued 25 January 1991 Resolved
REPLACE THE REGULATOR HOSE BETWEEN THE REGULATOR AND THE TANK ON THE BV_x001C_ EXTINGUISHER STBD SIDE HELO DECK. AS PER 46 CFR 108.495
Condition: Unknown
Due 25 January 1991
Resolved 25 January 1991
Accommodation/Occupational Safety
Issued 25 January 1991 Resolved
PROVIDE ONBOARD AND INSTALL FOUR APPROVED RELIEF VALVES WITH HAND RELIEVINGGEAR ON THE BULK TANKS AS PER 46 CFR 54.15._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 January 1991
Resolved 25 January 1991
Electrical
Issued 25 January 1991 Resolved
PROVIDE A REMOTE FUEL SHUTDOWN/SHUTOFF FOR THE EMERGENCY GENERATOR BETWEEN_x001C_THE FUEL TANK AND ENGINE. AS PER NVIC 4-78
Condition: Unknown
Due 25 January 1991
Resolved 25 January 1991
Fire Fighting
Issued 25 January 1991 Resolved
PROVIDE APPROVED DRAWING FOR THE SCR HALON SYSTEM AND SUBMIT UPDATED FIRE_x001C_ CONTROL PLAN AND AFFECTED PARTS OF OPERATIONS MANUAL FOR APPROVAL.
Condition: Unknown
Due 25 January 1991
Resolved 25 January 1991
Lifesaving
Issued 25 January 1991 Resolved
PROVIDE A FIRST AID KIT FOR CAPSULE NO. 3 WITH THE REQUIRED EQUIPMENTS PER_x001C_46 CFR 108.503 AND 46 CFR 160.041.
Condition: Unknown
Due 25 January 1991
Resolved 25 January 1991
Fire Fighting
Issued 25 January 1991 Resolved
REPAIR/REPLACE DEFECTIVE ALL PURPOSE FIRE NOZZEL ON FIRE STATION NO. 6.
Condition: Unknown
Due 25 January 1991
Resolved 25 January 1991
Lifesaving
Issued 25 January 1991 Resolved
REPAIR/REPLACE DEFECTIVE ENGINE EXHAUST BACK FLOW PREVENTORS ON ALL CAPSULES. REPLACE BROKEN AND NON APPROVED GLASS/PLEXIGLASS ON ALL CAPSULE_x001C_PORT LIGHTS PER 46 CFR 160.035 AND 46 CFR 108.503.
Condition: Unknown
Due 25 January 1991
Resolved 25 January 1991
Accommodation/Occupational Safety
Issued 25 January 1991 Resolved
MAKE PROPER REPAIRS TO THE INBOARD WATER MAKER TO MAKE OPERATIONAL AS PER_x001C_ NVIC 4-78.
Condition: Unknown
Due 25 January 1991
Resolved 25 January 1991
Construction/Loadline
Issued 3 July 1990 Resolved
REPAIR CRACKED FOUNDATION ON BOTH JACKING MOTORS LOCATED ON THE STBD. SIDE CANTILEVER JACKING MECHANISMS. REPAIRS TO BE COMPLETED IN ACCORDANCE WITH WELDING PROCEDURES IN VESSEL CONSTRUCTION PORTFOLIO. (PROVIDE COPY OF ORIG.CONSTRUCTION DESIGN/OR APPROVED MODIFICATIONS TO FOUNDATIONS).
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Construction/Loadline
Issued 3 July 1990 Resolved
ONCE REPAIRS COMPLETED, ENSURE STRUCTURAL FOUNDATION IS SOUND BY NDT TESTING METHODS. *(NOTE:INSP. OF PORT FOUNDATIONS MAY BE NECESSARY TO DETERMINE IF CRACKS PRESENT ALSO, THIS REQUEST VOICED IN PH.CON. W/CARL REDMOND 03JUL BY [name withheld])
Condition: Unknown
Due 3 July 1990
Resolved 3 July 1990
Electrical
Issued 25 January 1990 Resolved
REPAIR THE FLOODING SENSOR ON THE PORT SIDE OF THE SCR. ROOM.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Lifesaving
Issued 25 January 1990 Resolved
SHORTEN IN BOARD FULL OF #1 LIFEBOAT TO AVOID DOUBLE WRAPPING,
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Documentation
Issued 25 January 1990 Resolved
RESUBMIT THE HAZARDOUS LOCATION PLAN TO INDICATE THE TRIP TANK AS CLASS I DIV 1.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Fire Fighting
Issued 25 January 1990 Resolved
RESERVICE THE ANSUL CARTRIDGE OPERATED DRY CHEMICAL EXTINGUISHERS IN THE MUD PUMP ROOM AND OUTSIDE THE PORT CHANG ROOM MAIN DECK.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Electrical
Issued 25 January 1990 Resolved
CORRECT THE OPERATION OF THE DATA LOG GAS DETECTOR BOX LOCATED ON THE DRILLFLOOR. VISUAL INDICATION OF LOSS OF PURGE REQUIRED. UNIT TO REMAIN TAGGED OUT UNTILL REPAIR COMPLETED.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Lifesaving
Issued 25 January 1990 Resolved
MAKE PERMANINT FIBER GLASS REPAIR TO DECK OF #2 LIFEBOAT STBD BOW.
Condition: Unknown
Due 25 January 1990
Resolved 25 January 1990
Construction/Loadline
Issued 25 January 1989 Resolved
CORRECT AS NECESSARY THE THREE STAIR TOWER DOOK CLOSURE DEVICES AND LATCHES. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Construction/Loadline
Issued 25 January 1989 Resolved
REMOVE THE LOUVERED DOOR FROM THE STAIR TOWER ENTRANCE TO THE 3RD LEVEL. REPLACE WITH SOLID DOCK OF METAL CONSTRUCTION. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Fire Fighting
Issued 25 January 1989 Resolved
PROVIDE A FOG APPLICATOR FOR THE HELO DECK (10FT). COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Lifesaving
Issued 25 January 1989 Resolved
MAKE A PERMINENT REPAIR TO THE CRACK IN THE DECK ON #1 LIFEBOAT. CRACK LOCATED UNDER GRIPE. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Electrical
Issued 25 January 1989 Resolved
SERVICE ALL SCREW CAP COVERS ON EXPLOSION PROOF JUNCTION BOXES IN SHALE SHAKER AREA. MANY ARE BEGINNING TO SHOW SIGNS OF ADVERSE CORROSION. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Electrical
Issued 25 January 1989 Resolved
CORRECT NAV AID LIGHT TO COMPLY WITH 33CFR PART 67. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Lifesaving
Issued 25 January 1989 Resolved
PROVIDE 21 ADDITIONAL 4OZ. WATER PACKS FOR #3 LIFEBOAT. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Electrical
Issued 25 January 1989 Resolved
PRIOR TO DRILLING, REPLACE DETERIORATED NIPPLE BETWEEN EXPLOSION PROOF JUNCTION BOX AND EXPLOSION PROOF SWITCH BOX IN SHALE SHAKER. COMPLY BY: 31MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Unknown
Issued 25 January 1989 Resolved
MAKE OPERABLE LOW LUBE OIL SHUT DOWN ON #1 EMD. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Unknown
Issued 25 January 1989 Resolved
PROVIDE DOCUMENTATION THAT THE REMAINING 50FT SECTION OF FUEL OIL TRANSFER HOSE HAS BEEN PROPERLY HYDROSTATICALLY TESTED. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Lifesaving
Issued 25 January 1989 Resolved
PROVIDE 107 ADDITIONAL 4OZ. WATER PACKS FOR #3 LIFEBOAT. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Electrical
Issued 25 January 1989 Resolved
PRIOR TO DRILLING, PROVIDE VISUAL OR AUDIBLE LOSS OF PURGE ALARM IN ACCORDANCE WITH NFPA-496 FOR STROKE COUNTER LOCATED IN VICINITY OF DRILLER'S CONSOLE RIG FLOOR. COMPLY BY: 31MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Electrical
Issued 25 January 1989 Resolved
PRIOR TO DRILLING, REPLACE BROKEN VISUAL LOSS OF PURGE INDICATOR ON GEOLOGRAPH. COMPLY BY: 31MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Electrical
Issued 25 January 1989 Resolved
PROVIDE PROPER WARNING TAGS ON ALL PURGED ENCLOSURES IN ACCORDANCE WITH NEPA-496. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Electrical
Issued 25 January 1989 Resolved
CHECK EXPLOSION PROOF LIGHT, EXTERIOR SHALE SHAKER PORT SIDE FOR PROPER GROUND. ENSURE FEED CABLE IS NOT SPLICED. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Electrical
Issued 25 January 1989 Resolved
PRIOR TO DRILLING, REPLACE BROKEN EYS FITTING ON SHALE SHAKER SWITCH BOX. COMPLY BY: 31MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Electrical
Issued 25 January 1989 Resolved
PRIOR TO DRILLING, CHECK ALL EYS FITTINGS IN SHALE SHAKER AREA TO ENSURE THEY ARE PROPERLY POURED (FIVE WERE NOTED POURED DURING INSPECTION). COMPLY BY: 31MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Electrical
Issued 25 January 1989 Resolved
REPLACE CRACKED SCREW CAP COVER TO EXPLOSION PROOF JUNCTION BOX LOCATED AFT OVERHEAD IN SHAKER AREA. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Fire Fighting
Issued 25 January 1989 Resolved
HYDRO THE AIR BOTTLE LOCATED IN THE BRIDGE FIREMANS OUTFIT OR REPLACE WITH A NEW BOTTLE. COMPLY BY: 15MAR89
Condition: Unknown
Due 25 January 1989
Resolved 25 January 1989
Fire Fighting
Issued 21 April 1988 Resolved
PROVE PROPER OPERATION OF DIESEL ENGINE AUTOMATIC SHUT DOWN AND VENTILATIONAUTOMATIC SHUT DOWN UPON ACTIVATION OF HALON SYSTEM.
Condition: Unknown
Due 21 April 1988
Resolved 21 April 1988
Fire Fighting
Issued 3 February 1987 Resolved
PROVIDE APPROVED FIRE CONTROL PLAN WHICH ACCURATELY REFLECTS THE EXISTING FIRE HYDRANT AND FIRE HOSE LAYOUT
Condition: Unknown
Due 3 February 1987
Resolved 3 February 1987
Deck/Cargo
Issued 3 February 1987 Resolved
REPLACE BROKEN GLASS ON CRANE CAB REMOTE STATION PORT SIDE
Condition: Unknown
Due 3 February 1987
Resolved 3 February 1987
Construction/Loadline
Issued 3 February 1987 Resolved
REPLACE BROKEN PACKING GLANDS ON AIR PUMP VAVLE BEAM RUDS ON MAIN DECK
Condition: Unknown
Due 3 February 1987
Resolved 3 February 1987
Construction/Loadline
Issued 3 February 1987 Resolved
PAINT DRAFT MARKS STBD SIDE AFT, PLIMSOLL MARK STBD SIDE, AND HAILING PORT AFT.
Condition: Unknown
Due 3 February 1987
Resolved 3 February 1987
Deck/Cargo
Issued 3 February 1987 Resolved
PROVIDE EVIDENCE THAT AIR RECEIVER ON MAIN FLOOR HAS HAD HYDROSTATIC TEST OR CONDUT SATISFACTORY HYDROSTATIC TEST IN PRESENCE IN PRESENCE OF CG INSPECTOR TO 150% OF RECEIVER MAWP.
Condition: Unknown
Due 3 February 1987
Resolved 3 February 1987
Electrical
Issued 3 February 1987 Resolved
PROVIDE EVIDENCE THAT EMERGENCY LIGHT HAVE BEEN SUBJECTED TO SEMI ANNUAL 2 HOUR TEST.
Condition: Unknown
Due 3 February 1987
Resolved 3 February 1987
Electrical
Issued 3 February 1987 Resolved
PROVIDE EVIDENCE THAT EMERGENCY GENERATOR HAS RECEIVED ITS REQUIRED 2 HOUR TEST.
Condition: Unknown
Due 3 February 1987
Resolved 3 February 1987
Lifesaving
Issued 27 February 1986 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Lifesaving
Issued 27 February 1986 Resolved
REFILL AIR BOTTLES (03) IN THE PORT LIFEBOAT.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Lifesaving
Issued 27 February 1986 Resolved
PROVIDE ON BOARD 24 TRIANGULAR BANDAGES FOR THE FIRST AID KIT PER 46 CFR 108.707 AND 30 CFR 77.1707.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Lifesaving
Issued 27 February 1986 Resolved
MANNING IS REDUCED TO MAXIMUM OF 44 PERSONS PENDING REPAIR OR ADJUSTMENT OFTHE STARBOARD LIFEBOAT DAVIT SYSTEM.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Fire Fighting
Issued 27 February 1986 Resolved
PROVIDE COAST GUARD APPROVALE DATA FOR THE B-V FIRE EXTINGUISHER ON THE HELO.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Accommodation/Occupational Safety
Issued 27 February 1986 Resolved
PROVIDE OPERATIONAL COAST GUARD APPROVED MARINE SANITATION DEVICE OF SUFFICIENT CAPACITY FOR RIG. INSTALL AND PROVE SATISFACTORY OPERATION.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Deck/Cargo
Issued 27 February 1986 Resolved
INSTALL COUPLING GUARD ON LUBRICATING OIL TRANSFER PUMP IN MACHINERY SPACE.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Deck/Cargo
Issued 27 February 1986 Resolved
HYDROSTATICALLY TEST FUEL OIL TRANSFER HOSES TO 225 PSI. STENCIL TEST PRESSURE AND DATE ON HOSE, OR RECORD TEST DATA IN A PERMANENT LOG BOOK IDENTIFYING HOSE TESTED, DATE, AND PRESSURE.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Lifesaving
Issued 27 February 1986 Resolved
RESUBMIT FIRE CONTROL PLAN FOR APPROVAL INDICATING THE CURRENT LOCATION ANDNUMBER OF INFLATABLE LIFE RAFTS.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Lifesaving
Issued 27 February 1986 Resolved
REPAIR INOPERATIVE RELEASE CONTROL FOR THE STABOARD LIFEBOAT, ADJUST/REPAIRBRAKING SYSTEM FOR THE PORT LIFEBOAT.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Lifesaving
Issued 27 February 1986 Resolved
REPAIR/REPLACE WINDOWS (GLASS) IN THE PORT AND STARBOARD LIFEBOATS; BOW ANDSTERN RELEASING STATION AND STEARING STATION.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Lifesaving
Issued 27 February 1986 Resolved
REPLACE FUEL TANK OR CLEAN AND GAGE THICKNESS OF STEEL IN THE STARBOARD LIFE BOAT IN LIEU OF REPLACEMENT.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Lifesaving
Issued 27 February 1986 Resolved
CLEAN INTERIOR OF BOTH LIFEBOAT WINCH CONTROLLER, CLEAN ALL CONTACT AND ELECTRICAL CABLE CONNECTION TO CONTROLLER, REPLACE FUSES WITH NON-RENEWABLE LINK FUSES.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Lifesaving
Issued 27 February 1986 Resolved
SECURE COMPASS IN STARBOARD LIFEBOAT.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Lifesaving
Issued 27 February 1986 Resolved
REPLACE STERN FALLS ON THE STARBOARD LIFEBOAT DUE TO SPOT DETERICATION WHERE IT LAYS ON ONE OF THE DAVIT SHEAVES.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Lifesaving
Issued 27 February 1986 Resolved
REPAIR OR REPLACE BROKEN LIFE LINE, STARBOARD BOW OF THE PORT LIFEBOAT.
Condition: Unknown
Due 27 February 1986
Resolved 27 February 1986
Unknown
Issued 14 July 1985 Resolved
PROVIDE ABOARD THE RIG AN FMC CERTIFICATE (CERTIFICATE OF FINANCIAL RESPON-SIBILITY) WITH A VALID EXPIRATION DATE.
Condition: Unknown
Due 14 July 1985
Resolved 14 July 1985
Construction/Loadline
Issued 14 July 1985 Resolved
PLACE AN 18 INCH BY 18 INCH RADIUS INSERT IN DAMAGED SHELL PLATE LOCATED APPROXIMATELY 3 FEET DOWN FROM DECK IN NUMBER (20) TWENTY PRELOAD TANK.
Condition: Unknown
Due 14 July 1985
Resolved 14 July 1985
Deck/Cargo
Issued 14 July 1985 Resolved
MAKE AVAILABLE FOR INSPECTION TO AN ATTENDING USCG INSPECTOR THE FOLLOWING ITEMS: (A) #8 AND #25 PRELOAD DUMP VALVES (B) THE (3) THREE MUD PIT DUMP.
Condition: Unknown
Due 14 July 1985
Resolved 14 July 1985
Unknown
Issued 21 February 1984 Resolved
REPAIR THE #2 BILGE PUMP.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
PROVIDE A PROPER RELIEF VALVE FOR THE #2 AIR RECEIVER.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
TEST ALL ENGINE PROTECTION FUNCTIONS ON ALL MAIN GENERATOR DIESELS AND THE EMERGENCY GENERATOR.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE PENROD 63, DN589096.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
CONDUCT AND LOG EMERGENCY DRILLS AT LEAST ONCE A WEEK TO PREPARE FOR DRILLSFOR THE COAST GUARD INSPECTOR.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
REPLACE THE RING LIFE BUOYS LOCATED ON THE PORT SIDE.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
PROVIDE APPROVED FUEL HOSES AS REQUIRED BY 33 CFR 154.500.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
PROVIDE INSULATED MATTING FOR THE AREA IN FRONT OF THE ELECTRIC PANELS IN THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
STENCIL ALL MOTOR CONTROLLERS, VENTS AND GENERAL ALARM BELLS AS NEEDED THROUGHOUT THE RIG.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
REPAIR THE DEFECTIVE EMERGENCY LIGHT ON THE DRILL FLOOR.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
PROVIDE INSULATION FOR THE EMERGENCY GENERATOR MANIFOLD AND EXHAUST LINE.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
TEST THE REVERSE POWER RELAYS ON THE SCR SWITCHBOARD AND THE REVERSE POWER RELAY FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
REPAIR THE DEFECTIVE FORWARD LIMIT SWITCH FOR THE STARBOARD CAPSULE DAVIT.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
REPLACE THE MISSING CONTROLLER CAPS ON BOTH CAPSULE CONTROLLERS.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
PROVIDE OXYGEN EXPLOSIVE METERS FOR THE FIREMEN'S OUTFITS.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
PROVIDE THE CRANE RECORD BOOKS AS REQUIRED BY 46 CFR 109.437.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
PROVIDE PROPER BATTERY BOXES FOR THE GENERAL ALARMS AND NAVIGATION LIGHTS.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
REMOVE ALL LOCKING DEVICES FROM THE DOORS THROUGHOUT THE RIG.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
PROVIDE PROPER FUEL HOSE FOR EMERGENCY GENERATOR FROM THE DIESEL FUEL TANK.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
PROVIDE INSTRUCTIONS FOR THE OPERATION OF THE EMERGENCY GENERATOR.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
REPLACE THE GENERAL ALARM HORN ON THE DRILL FLOOR.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
REPAIR AND LABEL THE GENERAL ALARM HORN IN THE GENERATOR ROOM.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
REPAIR THE MUD PIT SELF-CLOSING DOORS.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 21 February 1984 Resolved
REPAIR THE GENERAL ALARM ROTATING LIGHT IN THE SACK ROOM.
Condition: Unknown
Due 21 February 1984
Resolved 21 February 1984
Unknown
Issued 8 February 1983 Resolved
(REQ. E2 CONTINUED) TWO LARGE JUNCTION BOXES LOCATED NEAR STAIRWELL ON FORWARD DOOR.
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Unknown
Issued 8 February 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL PENROD 63, DN589096
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Lifesaving
Issued 8 February 1983 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Unknown
Issued 8 February 1983 Resolved
REPAIR/REPLACE LAMP CHANGER IN UPPER PORT OBSTRUCTION LIGHT.
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Lifesaving
Issued 8 February 1983 Resolved
REPAIR/REPLACE #1 LIFEBOAT FALLS FAIRLEAD SHEAVE.
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Lifesaving
Issued 8 February 1983 Resolved
PROVIDE #1 BOATHOOK TO #1 LIFEBOAT.
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Lifesaving
Issued 8 February 1983 Resolved
PROVIDE GENERAL ALARM BELL OR LIGHT TO WARN PERSONNEL IN SHAKER HOUSE AND MUD PIT AREA.
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Construction/Loadline
Issued 8 February 1983 Resolved
TIGHTEN/REPAIR HANDRAILS IN ACCOMMODATION STAIRTOWER.
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Electrical
Issued 8 February 1983 Resolved
IN MUD PIT AREA: A) REPAIR SELF-CLOSING DOORS. B) REPAIR LOSS OF VENTILA-TION ALARM. C) SEAL BULKHEAD PENETRATIONS STARBOARD SIDE.
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Electrical
Issued 8 February 1983 Resolved
PROVIDE CAP OR PLUG FOR F/O FILL HOSE IN AUXILIARY GENERATOR ROOM.
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Accommodation/Occupational Safety
Issued 8 February 1983 Resolved
REPAIR REMOTE VENTILATION SHUTDOWN FOR QUARTERS.
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Electrical
Issued 8 February 1983 Resolved
ON THE DRILL FLOOR: A) PROVIDE EXPLOSION PROOF OR AIR PURGED CONNECTIONS FOR THE DRAWORKS AND ROTARY DC MOTORS. B) PERMANENTLY SEAL OPENINGS AND
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Unknown
Issued 8 February 1983 Resolved
(REQ. E3A CONTINUED) PROVIDE EYS SEALS FOR JUNCTION BOX NEAR FIRE EXTINGUISHER NUMBER 35. C) REPAIR AIR PURGE TO DRILLER'S CONSOLE.
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Unknown
Issued 8 February 1983 Resolved
REPAIR REACH ROD TO BILGE SUCTION VALVE IN SEA CHEST COMPARTMENT.
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Fire Fighting
Issued 8 February 1983 Resolved
REPAIR/REPLACE INOPERATIVE PRESSURE GAUGES ON BOTH FIRE PUMPS.
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Electrical
Issued 8 February 1983 Resolved
IN THE SHALE SHAKER AREA: A) PROVIDE CHICO FOR EYS SEAL ON SENSOR UNIT LOCATED BETWEEN SHAKERS. B) MAKE PROPER EXPLOSION PROOF CONNECTIONS TO THE
Condition: Unknown
Due 8 February 1983
Resolved 8 February 1983
Lifesaving
Issued 20 May 1982 Resolved
PROVIDE FOUR (4) PROJECTILES AND ONE (1) AUXILIARY LINE (1/2 BY 500') FOR LINE THROWING GEAR. (46 CFR 108.517)
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Unknown
Issued 20 May 1982 Resolved
MAKE DRILL RECORDER GRAPH ON DRILLFLOOR SUITABLE FOR HAZARDOUS LOCATIONS. (46 CFR 111.105)
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Unknown
Issued 20 May 1982 Resolved
MAKE PROPER ELECTRICAL CONNECTIONS FOR DRAWORKS AND ROTARY DC MOTORS. (46 CFR 111.105)
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Unknown
Issued 20 May 1982 Resolved
MAKE FLO SHO UNIT ON DRILL FLOOR SUITABLE FOR HAZARDOUS LOCATIONS.(46 CFR 111.105)
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Fire Fighting
Issued 20 May 1982 Resolved
REPLACE RUPTURED FIRE HOSE IN SACK ROOM. (NVC 4-78 3D(7)(B))
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Lifesaving
Issued 20 May 1982 Resolved
HAVE HYDROSTATIC RELEASES FOR LIFERAFTS NO. 1 AND 2 SERVICED AND ADJUST ALLSTRAPS FOR LIFERAFTS FOR PROPER RELEASE OPERATIONS. (NVC 4-78 3D(8))
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Electrical
Issued 20 May 1982 Resolved
PROVIDE LIGHTS AND GUARDS OVER BUNKS AS NECESSARY. (NVC 4-78 3D(1)(A))
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Lifesaving
Issued 20 May 1982 Resolved
PROVIDE WATERLIGHTS AND WHISTLES FOR LIFE PRESERVERS AS NECESSARY. (46 CFR 108.514)
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Deck/Cargo
Issued 20 May 1982 Resolved
PROVIDE GUARD FOR AIR TUGGER ON BOW. (46 CFR 108.233)
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Fire Fighting
Issued 20 May 1982 Resolved
DEMONSTRATE PROPER OPERATION OF BOTH OXYGEN/EXPLOSIVE METTER FOR FIREMAN'S OUTFIT. (46 CFR 108.497)
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Construction/Loadline
Issued 20 May 1982 Resolved
PROVIDE APPROVED COPIES OF OPERATING MANUAL CONTRUCTION PORTFOLIO AND STABILITY LETTER TO THE RIG. (NVC 4-78 3D(4))
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Lifesaving
Issued 20 May 1982 Resolved
HYDROSTATICALLY TEST OXYGEN CYLINDERS IN LIFEBOAT NO. 2. (NVC 4-78 3D(1))
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Navigation
Issued 20 May 1982 Resolved
PROVIDE WIND DIRECTION DEVICE FOR HELIPORT. (46 CFR 108.241)
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Navigation
Issued 20 May 1982 Resolved
PROVIDE GUARDS AND GLOBES FOR NOT UNDER COMMAND LIGHTS. (NVC 4-78 3D(1))
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Fire Fighting
Issued 20 May 1982 Resolved
PROVIDE A FIRE HOSE STATION FOR THE DRILL FLOOR. (NVC 4-78 3D(F)(D) AND (46CFR 108.423(B)
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Lifesaving
Issued 20 May 1982 Resolved
ADJUST WINCHES FOR PROPER OPERATION FOR BOTH LIFERAFTS. (46 CFR 108.507)
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Lifesaving
Issued 20 May 1982 Resolved
REPLACE WATER WITH CURRENTLY DATED DATED WATER AND REPLACE OR REMOVE FOOD IN CENTRAL STORAGE LOCKER FOR LIFEBOAT NO. 2. (46 CFR 94.20-10)
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982
Unknown
Issued 20 May 1982 Resolved
PROVIDE VISUAL INDICATOR OR ALARM FOR LOSS OF AIR PURGE PRESSURE TO GAS TANK UNIT IN DOGHOUSE.(46 CFR 111.105)
Condition: Unknown
Due 20 May 1982
Resolved 20 May 1982

Casualty record · 5

19 February 2004Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2012926
14 August 2006Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 2786725
23 August 2006Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 2786763
21 April 2007Routine · role: Involved in a Marine Investigation (non-casualty) · 1 injured · activity 2924322
23 March 2008Routine · role: Involved in a Marine Casualty · 1 injured · activity 3381980
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record