Records from 1981 to 2018. Most recent: inspection, 31 July 2018.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 47
31 July 2018
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6497571
17 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6482757
12 October 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6286266
13 November 2015
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5763168
24 July 2012
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4387941
2 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200548
10 August 2011
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4110241
22 July 2011
Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4112179
15 July 2008
Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3268782
6 September 2007
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3050441
19 July 2006
COI Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2717889
1 September 2004
Re-Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2183089
22 December 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1964926
7 May 2003
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1789879
4 April 2003
In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1774032
20 September 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1678223
5 August 2002
Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1657012
13 September 2001
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389470
16 February 2001
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 1521845
9 August 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437770
25 August 1999
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457681
11 August 1998
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442730
9 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878595
6 January 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1167443
15 July 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1178716
27 April 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1168261
4 March 1994
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1164801
4 October 1993
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1460660
29 March 1993
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1142178
20 November 1992
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1137954
26 October 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 684867
29 August 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 153674
20 July 1992
Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 960005
28 June 1992
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 220006
26 June 1992
Administrative
Administrative · Commandant (CG-INV-3) · Activity 957708
29 July 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 661634
25 July 1991
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 661633
10 April 1989
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1205673
8 April 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1303315
4 March 1988
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1027604
12 August 1987
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1337395
24 February 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1281007
30 September 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1276624
25 February 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 964547
23 April 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 963708
25 February 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 970345
27 February 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272059
Lifesaving › Lifefloat › Capacity
Issued 13 November 2015
No resolution recorded
Vessel only had 2 -15 person lifefloats. Total person allowed reduced to 30 until vessel installs higher lifesaving accommodations.
Action required: 705 - Other - as specified
Due 18 November 2015 — due date passed with no resolution recorded
Fire Fighting › Fire Main › Material
Issued 13 November 2015
Resolved
Replace 2 foot section of flexible piping installed in firemain system
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: Crew removed floexible piping and put in a mechanical plug due the the piping being unused.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 November 2015
Resolved
block and brace battery in E/R and remove/replace wingnuts
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: wingnuts removed and properly braced.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 November 2015
Resolved
provide supports for wire run on starboard E/R
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: Wires secured
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 November 2015
Resolved
Provide adequate lighting for E/R escape hatch
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: Adequate lighting provided
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 November 2015
Resolved
Provide guards for rotating machinery oon Port and Starboard prime movers
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: Guards fabricated around all rotating machinery.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 November 2015
Resolved
Provide first aid kit IAW Q spec
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: rep purchased approved first aid kit
Communications › Radio Communications › EPIRB
Issued 13 November 2015
Resolved
Replace battery in EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: Battery replaced
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 November 2015
Resolved
Provide exhaust wrapping on staboard engine turbocharger
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: all hot surfaces are properly insulated.
Engineering › Diesel Engine (propulsion-direct drive) › Connecting Rod
Issued 13 November 2015
Resolved
Starboard main engine throttle control on the navigational bridge were inoperable. Prior to movement
Action required: 705 - Other - as specified
Due 18 November 2015
Resolved 18 December 2015
Resolution: All throttle controls were exercised in the presence of attending marine inspector
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 September 2007
Resolved
Place chains on aft deck in between deck railings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 6 September 2007
Resolved
Place portable fire extinguisher on mounting bracket in passenger cabin.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 6 September 2007
Resolved
Place cover on light in water closet.
Due 5 October 2007
Resolved 14 September 2007
Engineering › Fuel Oil Service System › Hose
Issued 6 September 2007
Resolved
Place double clamps on all flexible fuel hoses in engine room (main engines & stbd shaft.)
Due 24 September 2007
Resolved 14 September 2007
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 6 September 2007
Resolved
Replace batteries in both fire detectors in fwd cabins. Re-test all fire detectors on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 6 September 2007
Resolved
Replace corroded pipjng for cooling water system on both main engines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Penetrations › Weld
Issued 6 September 2007
Resolved
Weld all through hull penetrations (sewage piping located in fwd engine room bulkhead, hydraulic piping located in fwd bulkhead in steering flat; all overhead vents.)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 6 September 2007
Resolved
Remove all dead-end wiring from main generator.
Due 5 October 2007
Resolved 14 September 2007
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 6 September 2007
Resolved
Properly secure flex hose on hydraulic storage tank (currently secured with rope.)
Due 5 October 2007
Resolved 14 September 2007
Construction/Loadline › Structures › Trunk
Issued 6 September 2007
Resolved
Gouge & re-weld cracked welds on exhaust fan trunk.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Engineering › Fuel Oil Service System › Hose
Issued 6 September 2007
Resolved
Replace both flexible fuel hses on stbd MDE. Bith hoses are punctured where hoses make contact with engine mount.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 6 September 2007
Resolved
Place non-conductive matting in front of electrical switchboard.
Due 5 October 2007
Resolved 18 September 2007
Pollution Prevention/Response › Prevention Equipment › Exhaust Gas Cleaning System
Issued 6 September 2007
Resolved
Repair leak & demonstrate proper watertight integrity on exhaust piping on stbd engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 September 2007
Resolved
Relace exhaust lagging on ort main engine.
Due 5 October 2007
Resolved 14 September 2007
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 6 September 2007
Resolved
Remove all 5 gallon buckets containing combustibles from engine room.
Due 5 October 2007
Resolved 14 September 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 September 2007
Resolved
Repair electrical wiring for bilge pumo & alarm located in engine room. Pump & alarm are inop
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Engineering › Steering Gear System › Hydraulic Hose
Issued 6 September 2007
Resolved
Repair excess hydraulic leaks on stainless piping in steering room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 6 September 2007
Resolved
Remove excess hydraulic oil from coamings in steering room.
Due 5 October 2007
Resolved 18 September 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 6 September 2007
Resolved
Replace lighting in steering room (inop)
Due 5 October 2007
Resolved 14 September 2007
Construction/Loadline › Penetrations › Weld
Issued 6 September 2007
Resolved
Weld around through hull penetration in steering flat for holding water tank flex hose (red)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Electrical › Electric Generation Source (service) › Generator
Issued 6 September 2007
Resolved
Prove proper operation of overspeed trips on generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2007
Fire Fighting › Fire Main › Material
Issued 6 September 2007
Resolved
Label fire main piping on deck.
Due 5 October 2007
Resolved 14 September 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 6 September 2007
Resolved
Label fresh water fill & switches on deck.
Due 5 October 2007
Resolved 14 September 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 September 2007
Resolved
Replace both mast headlights (inop)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Structures › Door
Issued 6 September 2007
Resolved
Repair hinge for watertight door into passenger cabin & repair broken windows.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Structures › Superstructure
Issued 6 September 2007
Resolved
Remove dryer vent & replace with watertight fitting in way of passenger cabin.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 6 September 2007
Resolved
Re-paint draft marks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2007
Construction/Loadline › Structures › Superstructure
Issued 6 September 2007
Resolved
Secure phone water on bridge & make watertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Penetrations › Pipe Flange
Issued 6 September 2007
Resolved
Repair/renew port side steering room vent & make watertight. Re-weld inside steering room overhead.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Communications › Radio Communications › EPIRB
Issued 6 September 2007
Resolved
Provide updated EPIRB registration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Structures › Ventilators
Issued 6 September 2007
Resolved
Repair holes & intall gaskets & pins on port & stbd vents on main deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 6 September 2007
Resolved
Replace SOLAS retro-reflective tape on all ring buoys.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 September 2007
Resolved
Demonstrate proper operation of remote emergency fuel shut-offs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 6 September 2007
Resolved
Man vsl in accordance to required crew complement on COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Structures › Manhole
Issued 6 September 2007
Resolved
Demonstrate proper operation of steering room manhole cover.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Engineering › Reduction Gearing/Clutches › Gear
Issued 6 September 2007
Resolved
Fix dip stick on clutch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 September 2007
Resolved
Remove oil from engine room bilge and clean bilge in rudder room.
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 18 September 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 6 September 2007
Resolved
Repair leaks to fuel system including emergency shutoff valves
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 September 2007
Resolved
Replace two damaged deck boards in engine room.
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 24 July 2008
Engineering › Bilge Water Management System › Pump
Issued 6 September 2007
Resolved
Demonstrate operation of bilge suction for marine inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 6 September 2007
Resolved
Repair oil / exhaust leak at engine exhaust manifolds.
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 24 July 2008
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 19 July 2006
Resolved
Demonstrate Proper Operation of SSB w/in 30 days.
Due 19 August 2006
Resolved 24 July 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 September 2004
Resolved
Anchor light inop.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Lifesaving › Buoyant Apparatus › Serviceable
Issued 1 September 2004
Resolved
Renew one lifefloat. Not serviceable.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 1 September 2004
Resolved
5 lifejackets need to be replaced. Not serviceable. Noted on prior inspection.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 September 2004
Resolved
Markings on all lifesaving need to be renewed.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 1 September 2004
Resolved
Manual ventilation closures missing locking pins. No way to actually secure closures currently. Provide pins.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 1 September 2004
Resolved
Provide proper fixed system for paint locker or remove all paint and flammable material from aft deck storage.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 September 2004
Resolved
Glass on main door cracked. Replace.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Engineering › Fuel Oil Service System › Valve
Issued 1 September 2004
Resolved
Port side fuel shut-off valve does not function properly. Repair and show proper operation.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Electrical › Electrical Distribution System (service) › Switchboard
Issued 1 September 2004
Resolved
Label all breakers. Several vital systems not labeled.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 1 September 2004
Resolved
Light in forward accomodation inop.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Engineering › Bilge Water Management System › Pump
Issued 1 September 2004
Resolved
Provide a seoparate source of power for second power bilge pump. Currently both bilge pumps run off a single generator. Vessel only has one generator. One pump can be run off of a main engine.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Fire Fighting › Remote Fuel Shutoff
Issued 22 December 2003
Resolved
Show proper operation of starboard remote fuel shut down.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2004
Resolved 22 December 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 22 December 2003
Resolved
Show proper operation of pilothouse port engine shutdown. LEGACY COMPONENT DESC: Engine Shutdown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2004
Resolved 22 December 2003
Communications › Audible Communications › Horn/Whistle
Issued 22 December 2003
Resolved
Show proper operation of ships horn.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2004
Resolved 22 December 2003
Documentation › Certificates/Documents
Issued 22 December 2003
Resolved
Provide valid FFC Safety and Bridge-to-Bridge Certificates. LEGACY COMPONENT DESC: FCC SSL
Due 22 January 2004
Resolved 22 December 2003
Deck/Cargo › Holds/Tanks
Issued 4 April 2003
Resolved
Engine room fwd and aft,and rudder room, hatch covers missing means to open from inside compartment. LEGACY COMPONENT DESC: Hatch Cover
Condition: Unknown
Due 4 May 2003
Resolved 15 April 2003
Resolution: Repairs conducted to hatch covers to provide proper means of escape from engine room and rudder room compartments.
Engineering › Fuel Oil Storage/Transfer System
Issued 4 April 2003
Resolved
Fuel tank vent pipe missing flame screen and closure device. Void space vent also missing bug screen and closure device. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Due 4 May 2003
Resolved 7 May 2003
Resolution: Provided
Lifesaving › Rigid Liferafts
Issued 4 April 2003
Resolved
Life floats not marked properly and water light inoperable. LEGACY COMPONENT DESC: Markings
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2003
Resolved 15 May 2003
Resolution: Life floats properly marked and water light renewed.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 18 September 2002
Resolved
Demostrate ready deployment of vsl anchor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 20 September 2002
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 September 2002
Resolved
Provide emergency lighting fixture iluminating emergency escape hatch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 20 September 2002
Fire Fighting › Fire Hoses › Condition
Issued 18 September 2002
Resolved
Provide vsl name on all fire hoses.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 20 September 2002
Stability › Watertight Integrity
Issued 5 August 2002
Resolved
Replace watertight scuttle to forepeak. LEGACY COMPONENT DESC: Watertight Scuttle
Action required: 705 - Other - as specified
Due 6 September 2002
Resolved 22 December 2004
Construction/Loadline
Issued 9 August 2000
Resolved
SECURE POTABLE WATER TANK TO DECK IN ENGINE ROOM.
Condition: Unknown
Due 9 August 2000
Resolved 9 August 2000
Engineering
Issued 9 August 2000
Resolved
PROPERLY INSTALL EXHAUST LAGGING ON NO.2 MAIN DIESEL ENGINE EXHAUST AND TURBO.
Condition: Unknown
Due 9 August 2000
Resolved 9 August 2000
Construction/Loadline
Issued 9 August 2000
Resolved
REPAIR FIREMAIN AND BILGE PIPING SYSTEMS. REMOVE RUBBER SOFT PATCHES BETWEEN PIPING AND INSTALL HARD PIPING, PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 9 August 2000
Resolved 9 August 2000
Documentation
Issued 4 March 1994
Resolved
VESSEL IS REQUIRED TO HAVE ON BOARD A VALID FCC RADIO SAFETY CERTIFICATE ISSUED BY FCC ENSURING VESSEL'S RADIO INSTALLATION REQUIREMENTS ARE MET.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994