MAURY USCG vessel records Sign in
← All vessels

MISS KATIE

MISS KATIE is a 1981 passenger vessel (inspected). The Coast Guard has recorded 47 inspections since 1981, most recently in July 2018, along with 78 deficiencies — 1 with no resolution recorded —.

Records from 1981 to 2018. Most recent: inspection, 31 July 2018.

Built
1981
Last inspected
31 July 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
366823850 (licence lapsed)
Maury page id
psix-52789

Inspections, by type

…with no type recorded15
…past their stated due date1
Years with a record 27 calendar years (1981–2018)
The 47 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it84 - Regulatory (Subpart C or D), Gross Ton
57 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDDFMMSI 366823850 · expired · compulsorily equipped · granted 29 July 2011, cancelled 23 October 2021
WCY6370MMSI not assigned · expired · voluntarily equipped · granted 12 August 1998, cancelled 18 October 2008 · licensed under a name not among this hull’s recorded names (not shown)
WCD7808MMSI not assigned · expired · compulsorily equipped · granted 14 February 1994, cancelled 25 April 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 47

31 July 2018 Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6497571
17 July 2018 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6482757
12 October 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6286266
13 November 2015 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5763168
24 July 2012 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4387941
2 December 2011 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4200548
10 August 2011 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4110241
22 July 2011 Examination of Repairs · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4112179
15 July 2008 Re-Inspection · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3268782
6 September 2007 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3050441
19 July 2006 COI Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2717889
1 September 2004 Re-Inspection · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2183089
22 December 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1964926
7 May 2003 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1789879
4 April 2003 In-Service Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1774032
20 September 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1678223
5 August 2002 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1657012
13 September 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1389470
16 February 2001 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 1521845
9 August 2000 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437770
25 August 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457681
11 August 1998 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442730
9 September 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878595
6 January 1995 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1167443
15 July 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1178716
27 April 1994 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1168261
4 March 1994 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1164801
4 October 1993 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1460660
29 March 1993 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1142178
20 November 1992 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1137954
26 October 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 684867
29 August 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 153674
20 July 1992 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 960005
28 June 1992 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 220006
26 June 1992 Administrative
Administrative · Commandant (CG-INV-3) · Activity 957708
29 July 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 661634
25 July 1991 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 661633
10 April 1989 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1205673
8 April 1988 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1303315
4 March 1988 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1027604
12 August 1987 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1337395
24 February 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1281007
30 September 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1276624
25 February 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 964547
23 April 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 963708
25 February 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 970345
27 February 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272059

Deficiency record · 78

Lifesaving › Lifefloat › Capacity
Issued 13 November 2015 No resolution recorded
Vessel only had 2 -15 person lifefloats. Total person allowed reduced to 30 until vessel installs higher lifesaving accommodations.
Action required: 705 - Other - as specified
Due 18 November 2015 — due date passed with no resolution recorded
Fire Fighting › Fire Main › Material
Issued 13 November 2015 Resolved
Replace 2 foot section of flexible piping installed in firemain system
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: Crew removed floexible piping and put in a mechanical plug due the the piping being unused.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 November 2015 Resolved
block and brace battery in E/R and remove/replace wingnuts
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: wingnuts removed and properly braced.
Electrical › Electrical Distribution System (service) › Cable
Issued 13 November 2015 Resolved
provide supports for wire run on starboard E/R
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: Wires secured
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 November 2015 Resolved
Provide adequate lighting for E/R escape hatch
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: Adequate lighting provided
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 13 November 2015 Resolved
Provide guards for rotating machinery oon Port and Starboard prime movers
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: Guards fabricated around all rotating machinery.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 November 2015 Resolved
Provide first aid kit IAW Q spec
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: rep purchased approved first aid kit
Communications › Radio Communications › EPIRB
Issued 13 November 2015 Resolved
Replace battery in EPIRB
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: Battery replaced
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 13 November 2015 Resolved
Provide exhaust wrapping on staboard engine turbocharger
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 November 2015
Resolved 18 December 2015
Resolution: all hot surfaces are properly insulated.
Engineering › Diesel Engine (propulsion-direct drive) › Connecting Rod
Issued 13 November 2015 Resolved
Starboard main engine throttle control on the navigational bridge were inoperable. Prior to movement
Action required: 705 - Other - as specified
Due 18 November 2015
Resolved 18 December 2015
Resolution: All throttle controls were exercised in the presence of attending marine inspector
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 6 September 2007 Resolved
Place chains on aft deck in between deck railings.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 6 September 2007 Resolved
Place portable fire extinguisher on mounting bracket in passenger cabin.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 6 September 2007 Resolved
Place cover on light in water closet.
Due 5 October 2007
Resolved 14 September 2007
Engineering › Fuel Oil Service System › Hose
Issued 6 September 2007 Resolved
Place double clamps on all flexible fuel hoses in engine room (main engines & stbd shaft.)
Due 24 September 2007
Resolved 14 September 2007
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 6 September 2007 Resolved
Replace batteries in both fire detectors in fwd cabins. Re-test all fire detectors on board.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 6 September 2007 Resolved
Replace corroded pipjng for cooling water system on both main engines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Penetrations › Weld
Issued 6 September 2007 Resolved
Weld all through hull penetrations (sewage piping located in fwd engine room bulkhead, hydraulic piping located in fwd bulkhead in steering flat; all overhead vents.)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 6 September 2007 Resolved
Remove all dead-end wiring from main generator.
Due 5 October 2007
Resolved 14 September 2007
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 6 September 2007 Resolved
Properly secure flex hose on hydraulic storage tank (currently secured with rope.)
Due 5 October 2007
Resolved 14 September 2007
Construction/Loadline › Structures › Trunk
Issued 6 September 2007 Resolved
Gouge & re-weld cracked welds on exhaust fan trunk.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Engineering › Fuel Oil Service System › Hose
Issued 6 September 2007 Resolved
Replace both flexible fuel hses on stbd MDE. Bith hoses are punctured where hoses make contact with engine mount.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 6 September 2007 Resolved
Place non-conductive matting in front of electrical switchboard.
Due 5 October 2007
Resolved 18 September 2007
Pollution Prevention/Response › Prevention Equipment › Exhaust Gas Cleaning System
Issued 6 September 2007 Resolved
Repair leak & demonstrate proper watertight integrity on exhaust piping on stbd engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 6 September 2007 Resolved
Relace exhaust lagging on ort main engine.
Due 5 October 2007
Resolved 14 September 2007
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 6 September 2007 Resolved
Remove all 5 gallon buckets containing combustibles from engine room.
Due 5 October 2007
Resolved 14 September 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 September 2007 Resolved
Repair electrical wiring for bilge pumo & alarm located in engine room. Pump & alarm are inop
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Engineering › Steering Gear System › Hydraulic Hose
Issued 6 September 2007 Resolved
Repair excess hydraulic leaks on stainless piping in steering room.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Pollution Prevention/Response › Prevention Equipment › Means of Removal from within Coaming
Issued 6 September 2007 Resolved
Remove excess hydraulic oil from coamings in steering room.
Due 5 October 2007
Resolved 18 September 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 6 September 2007 Resolved
Replace lighting in steering room (inop)
Due 5 October 2007
Resolved 14 September 2007
Construction/Loadline › Penetrations › Weld
Issued 6 September 2007 Resolved
Weld around through hull penetration in steering flat for holding water tank flex hose (red)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Electrical › Electric Generation Source (service) › Generator
Issued 6 September 2007 Resolved
Prove proper operation of overspeed trips on generator.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2007
Fire Fighting › Fire Main › Material
Issued 6 September 2007 Resolved
Label fire main piping on deck.
Due 5 October 2007
Resolved 14 September 2007
Accommodation/Occupational Safety › Potable Water System › General
Issued 6 September 2007 Resolved
Label fresh water fill & switches on deck.
Due 5 October 2007
Resolved 14 September 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 6 September 2007 Resolved
Replace both mast headlights (inop)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Structures › Door
Issued 6 September 2007 Resolved
Repair hinge for watertight door into passenger cabin & repair broken windows.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Structures › Superstructure
Issued 6 September 2007 Resolved
Remove dryer vent & replace with watertight fitting in way of passenger cabin.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 6 September 2007 Resolved
Re-paint draft marks.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2007
Construction/Loadline › Structures › Superstructure
Issued 6 September 2007 Resolved
Secure phone water on bridge & make watertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Penetrations › Pipe Flange
Issued 6 September 2007 Resolved
Repair/renew port side steering room vent & make watertight. Re-weld inside steering room overhead.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Communications › Radio Communications › EPIRB
Issued 6 September 2007 Resolved
Provide updated EPIRB registration.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Structures › Ventilators
Issued 6 September 2007 Resolved
Repair holes & intall gaskets & pins on port & stbd vents on main deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Lifesaving › Buoyant Apparatus › Retroreflective Material
Issued 6 September 2007 Resolved
Replace SOLAS retro-reflective tape on all ring buoys.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Fire Fighting › Remote Fuel Shutoff › General
Issued 6 September 2007 Resolved
Demonstrate proper operation of remote emergency fuel shut-offs.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 6 September 2007 Resolved
Man vsl in accordance to required crew complement on COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Construction/Loadline › Structures › Manhole
Issued 6 September 2007 Resolved
Demonstrate proper operation of steering room manhole cover.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Engineering › Reduction Gearing/Clutches › Gear
Issued 6 September 2007 Resolved
Fix dip stick on clutch.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 September 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 6 September 2007 Resolved
Remove oil from engine room bilge and clean bilge in rudder room.
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 18 September 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 6 September 2007 Resolved
Repair leaks to fuel system including emergency shutoff valves
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 6 September 2007 Resolved
Replace two damaged deck boards in engine room.
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 24 July 2008
Engineering › Bilge Water Management System › Pump
Issued 6 September 2007 Resolved
Demonstrate operation of bilge suction for marine inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 September 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 6 September 2007 Resolved
Repair oil / exhaust leak at engine exhaust manifolds.
Action required: 705 - Other - as specified
Due 14 October 2007
Resolved 24 July 2008
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 19 July 2006 Resolved
Demonstrate Proper Operation of SSB w/in 30 days.
Due 19 August 2006
Resolved 24 July 2008
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 September 2004 Resolved
Anchor light inop.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Lifesaving › Buoyant Apparatus › Serviceable
Issued 1 September 2004 Resolved
Renew one lifefloat. Not serviceable.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 1 September 2004 Resolved
5 lifejackets need to be replaced. Not serviceable. Noted on prior inspection.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 1 September 2004 Resolved
Markings on all lifesaving need to be renewed.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Accommodation/Occupational Safety › Ventilation › General
Issued 1 September 2004 Resolved
Manual ventilation closures missing locking pins. No way to actually secure closures currently. Provide pins.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 1 September 2004 Resolved
Provide proper fixed system for paint locker or remove all paint and flammable material from aft deck storage.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 September 2004 Resolved
Glass on main door cracked. Replace.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Engineering › Fuel Oil Service System › Valve
Issued 1 September 2004 Resolved
Port side fuel shut-off valve does not function properly. Repair and show proper operation.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Electrical › Electrical Distribution System (service) › Switchboard
Issued 1 September 2004 Resolved
Label all breakers. Several vital systems not labeled.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 1 September 2004 Resolved
Light in forward accomodation inop.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Engineering › Bilge Water Management System › Pump
Issued 1 September 2004 Resolved
Provide a seoparate source of power for second power bilge pump. Currently both bilge pumps run off a single generator. Vessel only has one generator. One pump can be run off of a main engine.
Condition: Improper/Lack of Maintenance
Due 7 September 2004
Resolved 10 September 2004
Fire Fighting › Remote Fuel Shutoff
Issued 22 December 2003 Resolved
Show proper operation of starboard remote fuel shut down.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2004
Resolved 22 December 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 22 December 2003 Resolved
Show proper operation of pilothouse port engine shutdown. LEGACY COMPONENT DESC: Engine Shutdown
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2004
Resolved 22 December 2003
Communications › Audible Communications › Horn/Whistle
Issued 22 December 2003 Resolved
Show proper operation of ships horn.
Action required: 17 - Rectify deficiencies prior to departure
Due 22 January 2004
Resolved 22 December 2003
Documentation › Certificates/Documents
Issued 22 December 2003 Resolved
Provide valid FFC Safety and Bridge-to-Bridge Certificates. LEGACY COMPONENT DESC: FCC SSL
Due 22 January 2004
Resolved 22 December 2003
Deck/Cargo › Holds/Tanks
Issued 4 April 2003 Resolved
Engine room fwd and aft,and rudder room, hatch covers missing means to open from inside compartment. LEGACY COMPONENT DESC: Hatch Cover
Condition: Unknown
Due 4 May 2003
Resolved 15 April 2003
Resolution: Repairs conducted to hatch covers to provide proper means of escape from engine room and rudder room compartments.
Engineering › Fuel Oil Storage/Transfer System
Issued 4 April 2003 Resolved
Fuel tank vent pipe missing flame screen and closure device. Void space vent also missing bug screen and closure device. LEGACY COMPONENT DESC: Vent Pipe
Condition: Improper/Lack of Maintenance
Due 4 May 2003
Resolved 7 May 2003
Resolution: Provided
Lifesaving › Rigid Liferafts
Issued 4 April 2003 Resolved
Life floats not marked properly and water light inoperable. LEGACY COMPONENT DESC: Markings
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 May 2003
Resolved 15 May 2003
Resolution: Life floats properly marked and water light renewed.
Deck/Cargo › Mooring/Anchoring › Anchor Shackle
Issued 18 September 2002 Resolved
Demostrate ready deployment of vsl anchor.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 20 September 2002
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 September 2002 Resolved
Provide emergency lighting fixture iluminating emergency escape hatch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 20 September 2002
Fire Fighting › Fire Hoses › Condition
Issued 18 September 2002 Resolved
Provide vsl name on all fire hoses.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 September 2002
Resolved 20 September 2002
Stability › Watertight Integrity
Issued 5 August 2002 Resolved
Replace watertight scuttle to forepeak. LEGACY COMPONENT DESC: Watertight Scuttle
Action required: 705 - Other - as specified
Due 6 September 2002
Resolved 22 December 2004
Construction/Loadline
Issued 9 August 2000 Resolved
SECURE POTABLE WATER TANK TO DECK IN ENGINE ROOM.
Condition: Unknown
Due 9 August 2000
Resolved 9 August 2000
Engineering
Issued 9 August 2000 Resolved
PROPERLY INSTALL EXHAUST LAGGING ON NO.2 MAIN DIESEL ENGINE EXHAUST AND TURBO.
Condition: Unknown
Due 9 August 2000
Resolved 9 August 2000
Construction/Loadline
Issued 9 August 2000 Resolved
REPAIR FIREMAIN AND BILGE PIPING SYSTEMS. REMOVE RUBBER SOFT PATCHES BETWEEN PIPING AND INSTALL HARD PIPING, PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 9 August 2000
Resolved 9 August 2000
Documentation
Issued 4 March 1994 Resolved
VESSEL IS REQUIRED TO HAVE ON BOARD A VALID FCC RADIO SAFETY CERTIFICATE ISSUED BY FCC ENSURING VESSEL'S RADIO INSTALLATION REQUIREMENTS ARE MET.
Condition: Unknown
Due 4 March 1994
Resolved 4 March 1994

Ownership record