MAURY USCG vessel records Sign in
← All vessels

BROWN PELICAN

BROWN PELICAN is a 1981 passenger vessel (inspected). The Coast Guard has recorded 71 inspections since 1981, most recently in August 2025, along with 64 deficiencies and 1 operational control.

Records from 1981 to 2025. Most recent: inspection, 21 August 2025.

Built
1981
Last inspected
21 August 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDM7643
Flag
UNITED STATES
368061350
Maury page id
psix-52813

Inspections, by type

…with no type recorded3
Years with a record 40 calendar years (1981–2025)
The 71 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)46.0 ft × 15.0 ft × 5.6 ft
Registered tonnagegross 28 / net 19
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNEUVILLE · LOREAUVILLE, LA, UNITED STATES · built 1981
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portROCKPORT, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 31 December 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it28 - Regulatory (Subpart C or D), Gross Ton
19 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDM7643MMSI 368061350 · active · compulsorily equipped · granted 25 January 2022, expires 25 January 2032
WDK5067MMSI 368061350 · cancelled · compulsorily equipped · granted 6 October 2018, cancelled 19 January 2022 · licensed under a name not among this hull’s recorded names (not shown)
WDE4398MMSI 367352590 · expired · compulsorily equipped · granted 29 April 2008, cancelled 30 June 2018 · licensed under a name not among this hull’s recorded names (not shown)
WDE4400MMSI 367352640 · expired · compulsorily equipped · granted 29 April 2008, cancelled 30 June 2018 · licensed under a name not among this hull’s recorded names (not shown)
WTE2912MMSI not assigned · expired · compulsorily equipped · granted 18 December 1997, cancelled 12 April 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 71

21 August 2025 Internal Structural Exam · Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8215207
16 June 2025 In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 8157918
20 January 2025 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 8067191
25 April 2024 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7901196
7 August 2023 Examination of Repairs · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7762428
26 January 2023 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7627567
23 February 2022 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7400933
2 February 2022 COI Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7373663
24 August 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7296137
9 September 2020 Simplified Stability Test
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7056156
16 June 2020 Annual Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7013806
11 September 2019 Deficiency Check
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6810799
15 August 2019 Internal Structural Exam · DAPI Audit · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6775451
18 October 2018 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6562374
18 September 2017 Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6272652
1 August 2017 Administrative Inspection · Deficiency Check · Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6227336
20 July 2017 Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6212976
3 November 2016 Deficiency Check · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 6034099
3 December 2015 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5775169
19 November 2015 In-Service Inspection · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5865559
2 September 2015 Examination of Repairs · Hull Examination · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5717884
12 July 2012 Administrative Inspection · COI Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4376352
3 August 2011 Hull Examination · Administrative Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4108936
13 July 2011 Administrative Inspection · Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 4066209
21 July 2009 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3541508
18 June 2008 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3226432
10 October 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3075771
16 April 2007 COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2908742
26 October 2006 Damage Survey
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2809050
23 May 2006 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2656427
8 December 2005 Hull Examination
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2576775
28 July 2005 Annual Inspection
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2456016
13 May 2004 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2066295
26 January 2004 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1992603
14 May 2003 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1791539
18 June 2002 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1632127
2 May 2002 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1611352
3 May 2001 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1412286
17 July 2000 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1393451
11 May 2000 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1461293
7 May 1999 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1430692
30 July 1998 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1419984
24 June 1998 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 792676
20 May 1998 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1126944
6 May 1997 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1380863
18 December 1996 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1367997
8 May 1996 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1390253
31 October 1995 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1425649
6 June 1995 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1405717
29 June 1994 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1407344
10 January 1994 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1362902
12 May 1993 MARPOL Annex V Examination · Hull Examination · COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1455062
20 August 1992 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1467358
20 May 1992 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1261742
7 November 1991 Damage Survey
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 945281
31 July 1991 Deficiency Check
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1247229
29 July 1991 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 665330
26 June 1991 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 913165
25 February 1991 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 919483
15 May 1990 COI Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 920461
15 August 1989 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1198575
19 June 1989 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1349486
15 March 1988 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1034906
8 February 1988 Hull Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1019297
30 September 1987 Administrative
Administrative · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1010834
3 June 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311699
21 April 1987 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1024534
7 May 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991266
17 October 1985 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301322
17 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285040
12 March 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972105

Deficiency record · 64

07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 16 June 2020 Resolved
The power fire pump shall be self priming and of such size as to discharge an effective stream from a hose connected to the highest outlet. Repair holed fire main.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2020
Resolution: Replaced the wasted section of pipe.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 June 2020 Resolved
Fuel lines shall be accessible, protected from mechanical injury and effectively secured from movement and vibration. Repair fuel leak at emergency fuel shutoff in the lazarette.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2020
Resolution: Repaired fuel leak.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 June 2020 Resolved
The vessel must have one ring life buoy that meets the requirements of 160.050. Grabline on life buoy must be in acceptable condition.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 July 2020
Resolution: Replaced the life bouy
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 16 June 2020 Resolved
Vessel is required a masthead light. Repair masthead light to illuminate properly. Limited to daytime operations and may not operate in restricted visibility.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 16 July 2020
Resolution: Repaired mast light and proved proper operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 16 June 2020 Resolved
Penetrations in watertight bulkheads must have a means to make them watertight. Seal 2 bulkhead penetrations between void space and engine room.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 16 July 2020
Resolution: Sealed penatrations in the bhd.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 June 2020 Resolved
All electrical installations shall be to the satisfaction of the [name withheld] hardwired extension cord IWO of head. Provide supports for wire run on port side in way of new side shell insert. Remove port wire in void bilge.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 7 October 2021
Resolution: Superseded or corrected during a subsequent inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 16 June 2020 Resolved
Fuel shutoffs are to be properly labeled. Label emergency fuel shut off and direction for turning for proper function of shut-off.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2020
Resolved 16 July 2020
Resolution: Marked the emerency fuel shut off to include direction of operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2019 Resolved
Vessel has water leak on the Starboard inboard exhaust (Steady Stream) leaking into the bilge and does not meet the minimum standard of Diesel engine exhaust piping per 46CFR182.15-20 and 46CFR182.20-20. The vessel restricted from carrying passengers until repaired to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 September 2019
Resolution: The holed section of the exhaust piping was cut out and new section fitted in its place. The starboard engine was run for approximately 10 minutes and no water leak was observed on the starboard inboard exhaust.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2019 Resolved
Vessel has water leak on the Exhaust generator at the penetration on the side shell (Steady Stream)m leaking into the bilge and does not meet the minimum standard of Diesel engine exhaust piping per 46CFR182.15-20 and 46CFR182.20-20. The is vessel restricted from carrying passengers until area is cropped and renewed the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 September 2019
Resolution: The thru hull fitting in way of the generator exhaust was cut out. The cut out piece revealed a two inch crack which caused the leak. A new thru hull piece was fitted and welded into place. The exhaust system was tested while the engine was running for a
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 August 2019 Resolved
Vessel must correct the 2 water leaks in the engine room. Vessel representatives must ensure that oily mixtures are retained on board in the vessels bilges and only discharged to a reception facility as described in 33CFR155.330, this will be facilitated by disabling the automatic feature on your electrical submersible pump.The vessel restricted from carrying passengers until repaired to the satisfaction of an attending Coast Guard Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 11 September 2019
Resolution: The wiring for the float switch in way of the automatic bilge pump activator was removed to prevent the discharge of oily water mixture over the side. Informed master that the automatic function can be reattached after the oily water mixture has been rem
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 18 October 2018 Resolved
Engine room hatches gastest have failled or were missing allowing water into the E/R
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2018
Resolved 8 November 2018
Resolution: Engine room hatches were tested for water tightness.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 18 October 2018 Resolved
Passenger vessels require installation of DSC radio.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2018
Resolved 8 November 2018
Resolution: DSC was installed on the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 October 2018 Resolved
Life Buoy was missing retro
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2018
Resolved 8 November 2018
Resolution: Solas approved retroflective tape was placed on the lifebuoy.
Engineering › Steering Gear System › Rudder
Issued 1 August 2017 Resolved
Vessels port side rudder on the forward leading edge is wasted, additionally the weld that attaches the rudder to the rudder shaft shows signs of excessive degradation and does not meet the original design, suitable condition, or the main steering apparatus requirements as required by 46CFR176.610(a), 46CFR 176.814 and 46 CFR182.30-1. Owner must submit plan to replace rudder to the attending Mar
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 24 August 2017
Resolution: Onsite verification sat.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 1 August 2017 Resolved
2. Vessel water lubricated bearings on both port and starboard side are excessively worn on the viewable portions bearings of the and does not meet the minimum requirements that Rubber bearings must be renewed when any water groove is found to be half its original depth as required by 46CFR176.670 (a) and MSM VOL II SEC B CH 3 D 8. Owner must submit plan to replace both bearings or draw the shaft
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 24 August 2017
Resolution: Onsite verification sat.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 1 August 2017 Resolved
Vessels port propeller 4 blade tips were damaged and does not meet the original design, or suitable condition of the propeller as required by 46CFR176.610(a). Owner must submit plan for the propeller to the attending Marine Inspector for approval. Once approval has been obtained, execute plan. Vessel has 30 days to correct deficiency to the satisfaction attending Marine Inspector.
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 24 August 2017
Resolution: Onsite verification sat.
Engineering › Sea-water System (primary cooling) › Valve
Issued 1 August 2017 Resolved
Remove sea valve's for inspection as required by 46CFR176.610(a). Vessel has 30 days to correct deficiency to the satisfaction attending Marine Inspector.
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 24 August 2017
Resolution: Onsite verification sat.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 1 August 2017 Resolved
Vessel's Port Main Engine underwent a replacement in kind and does not meet the suitability in type and design main propulsion requirements of the hull of which it is installed per 46CFR182.05-1. Restore the main engine to suitable operation and conduct carry out appropriate machinery inspection / operational tests per 46CFR176.804, in the presence of a Coast Guard Marine Inspector and prior to op
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 September 2017
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 20 July 2017 Resolved
Replace wasted port MDE 4" exhaust hose.
Due 20 August 2017
Resolved 31 August 2017
Fire Fighting › Remote Fuel Shutoff › General
Issued 20 July 2017 Resolved
Mark emergency fuel shutoffs on aft deck.
Due 27 July 2017
Resolved 31 August 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 20 July 2017 Resolved
Replace clip on life ring light.
Due 27 July 2017
Resolved 31 August 2017
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 20 July 2017 Resolved
Establish life saving mainenance record & make available to MI
Due 27 July 2017
Resolved 31 August 2017
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 July 2017 Resolved
Maintain log of required drills & make available to MI.
Due 27 July 2017
Resolved 31 August 2017
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 November 2016 Resolved
Place current light list on board.
Due 3 December 2016
Resolved 10 January 2017
Fire Fighting › Fire Bucket › Stenciling
Issued 3 November 2016 Resolved
Label Fire buckets
Due 3 December 2016
Resolved 10 January 2017
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 3 November 2016 Resolved
Label one child PFD
Due 3 December 2016
Resolved 10 January 2017
Lifesaving › Lifebuoys › Serviceable
Issued 3 November 2016 Resolved
Renew life ring & label with vessel name.
Due 3 December 2016
Resolved 10 January 2017
Engineering › Fuel Oil Service System › Valve
Issued 3 December 2015 Resolved
Fix fuel leak on remote fuel shutoff.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 December 2015
Resolved 3 December 2015
Resolution: Fuel leak fixed once packing nut was tightened.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 19 November 2015 Resolved
Replace 40 amp breaker on genset with 35 amp breaker.
Action required: 705 - Other - as specified
Resolved 29 April 2016
Communications › Public Address System › Announcing Station
Issued 30 July 2009 Resolved
Demonstrate proper operation of public address system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2009
Resolved 3 September 2009
Resolution: O/O Replaced loud hailer, conducted satisfactory test with audible announcements heard in canbin and aft deck.
Communications › Alarms/Indicators › High Water Alarm
Issued 30 July 2009 Resolved
Provide high water level audible alarm for #2 void at operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2009
Resolution: Void #2 high water level alarm succesfully tested.
Communications › Alarms/Indicators › Engineers' Assistance-needed Alarm
Issued 30 July 2009 Resolved
Prove proper operation of exhaust cooling water low flow indicator at operating station.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2009
Resolution: O/O replaced indicator, indicator announced succesfully during engine startup.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 30 July 2009 Resolved
Provide mount for bell.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 August 2009
Resolved 3 September 2009
Resolution: O/O provided new bell and mount, mount secured to ouboard bulkhead of pilot house on port side.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder
Issued 30 July 2009 Resolved
Prove proper operation of starboard engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 September 2009
Resolution: O/O conducted satisfactory test of both port and starboard main.
Engineering › Bilge Water Management System › Pump
Issued 18 June 2008 Resolved
Ensure proper operation of aft laz fixed bilge system.
Condition: Unknown
Due 30 June 2008
Resolved 7 July 2008
Resolution: Fixed bilge piping in rudder space
Engineering › Steering Gear System › Rudder
Issued 26 October 2006 Resolved
Both rudder post was wasted due to stray current corrision. Cropped and renewed rudder post.
Condition: Unknown
Due 27 October 2006
Resolved 27 October 2006
Resolution: Replaced in kind
Construction/Loadline › Structures › Deck Plating
Issued 8 December 2005 Resolved
C&R deck plating below toilet & MSD in #2 space.
Action required: 705 - Other - as specified
Resolved 19 December 2005
Engineering › Bilge Water Management System › Piping
Issued 8 December 2005 Resolved
C & R to original rusted bilge piping in #2 space approximately 4 ft aft of fwd bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 December 2005
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 8 December 2005 Resolved
Tighten & Replace bench seating screws in #2 space.
Action required: 705 - Other - as specified
Resolved 19 December 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 8 December 2005 Resolved
Make new shafts and props available for inspection.
Action required: 705 - Other - as specified
Resolved 19 December 2005
Resolution: sat inspection
Engineering › Sea-water System (primary cooling) › Piping
Issued 28 July 2005 Resolved
Replace kinked raw water hose on generator.
Condition: Improper/Lack of Maintenance
Due 18 August 2005
Resolved 23 August 2005
Engineering › Fuel Oil Service System › Hose
Issued 28 July 2005 Resolved
Provide double clamps on all vital system hoses on engine.
Condition: Improper/Lack of Maintenance
Due 18 August 2005
Resolved 23 August 2005
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 28 July 2005 Resolved
Provide new certificate for all portable fire extinguishers (due for service by 31 Aug 05)
Due 31 August 2005
Resolved 23 August 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 July 2005 Resolved
Remove dead wiring from the vessel.
Due 18 August 2005
Resolved 23 August 2005
Lifesaving › Lifefloat › Lifeline
Issued 28 July 2005 Resolved
Replace all lifelines on lifefloat or remove non-required life float from vessel.
Condition: Improper/Lack of Maintenance
Due 18 August 2005
Resolved 23 August 2005
Lifesaving › Lifefloat › Serviceable
Issued 28 July 2005 Resolved
Repair holes in lifefloat and provide certification tag for weak link or remove lifefloat from vessel.
Due 18 August 2005
Resolved 23 August 2005
Engineering › Fuel Oil Service System › Gauge
Issued 28 July 2005 Resolved
Repair leaking oil gauges at bridge operating station.
Condition: Improper/Lack of Maintenance
Due 18 August 2005
Resolved 23 August 2005
Documentation
Issued 7 May 1999 Resolved
Post emergency broadcast placard.
Condition: Unknown
Due 21 May 1999
Resolved 26 May 1999
Electrical
Issued 7 May 1999 Resolved
Provide guard for light in MSD space.
Condition: Unknown
Due 21 May 1999
Resolved 26 May 1999
Navigation
Issued 7 May 1999 Resolved
Replace or repair sound producing device.
Condition: Unknown
Due 21 May 1999
Resolved 26 May 1999
Fire Fighting
Issued 20 May 1998 Resolved
Provide fire hose as required by 46 CFR 181.320.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Navigation
Issued 20 May 1998 Resolved
Provide double nutted connection on tiller arm.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Lifesaving
Issued 20 May 1998 Resolved
Provide reflective tape on ring buoy as required by 46 CFR 185.604.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Lifesaving
Issued 20 May 1998 Resolved
Provide markings on ring buoy as required by 46 CFR 185.604.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Lifesaving
Issued 20 May 1992 Resolved
1 ORANGE SMOKE & 1 HAND RED FLARE MISSING.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Engineering
Issued 20 May 1992 Resolved
FLAME SCREEN ON FUEL TANK MISSING.
Condition: Unknown
Due 20 May 1992
Resolved 20 May 1992
Engineering
Issued 26 June 1991 Resolved
INSULATION ON EXHAUST ELBOW ON STBD MAIN ENGINE WORN & COOLING WATER HOSE WORN.
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991
Lifesaving
Issued 26 June 1991 Resolved
NUMBERS OF PFD'S NOT STENCILLED ON STOWAGE CONTAINERS.
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991
Lifesaving
Issued 26 June 1991 Resolved
LIFEFLOAT CRACKED IN PLACES.
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991
Lifesaving
Issued 26 June 1991 Resolved
PADDLES FOR LIFEFLOAT BROKEN.
Condition: Unknown
Due 26 June 1991
Resolved 26 June 1991
Electrical
Issued 19 June 1989 Resolved
RELINE BATTERY TRAY WITH LEAD OR FIBERGLASS.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Navigation
Issued 19 June 1989 Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Fire Fighting
Issued 15 March 1988 Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS SERVICED.
Condition: Unknown
Due 15 March 1988
Resolved 15 March 1988
Lifesaving
Issued 15 March 1988 Resolved
PROCURE AND ATTACH ONE OAR TO LIFEFLOAT.
Condition: Unknown
Due 15 March 1988
Resolved 15 March 1988

Ownership record