MAURY USCG vessel records Sign in
← All vessels

ENSCO 83

ENSCO 83 is a 1979 mobile offshore drilling unit. The Coast Guard has recorded 119 inspections since 1981, most recently in June 2016, along with 134 deficiencies and 1 casualty investigation in 2004.

Records from 1981 to 2016. Most recent: inspection, 13 June 2016.

Built
1979
Last inspected
13 June 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8753768 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
LIBERIA
—
Maury page id
psix-52842

Inspections, by type

…with no type recorded47
Years with a record 30 calendar years (1981–2016)
The 119 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it4483 - Convention (Subpart B), Gross Ton
1344 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 119

13 June 2016 Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5905954
20 April 2009 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3456557
14 April 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3452491
2 April 2009 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3444766
21 October 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3348756
11 August 2008 COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3295674
10 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3161410
17 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3132227
24 May 2007 COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2938997
15 August 2006 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2747495
25 May 2005 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2367740
8 March 2005 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2305763
8 October 2004 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2225042
19 August 2004 Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2161942
25 May 2004 Underwater Inspection in lieu of Drydock
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2079093
24 May 2004 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2076990
15 February 2004 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2012921
29 July 2003 Administrative Inspection · Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1924698
7 July 2003 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1838689
27 April 2003 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1808597
27 March 2003 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1770188
20 March 2003 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760079
1 October 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1682727
13 August 2002 Deficiency Check · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1660674
4 August 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1660686
10 June 2002 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1635812
4 April 2002 Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1601059
27 January 2002 Hull Examination · Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1479466
25 January 2002 Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481336
26 June 2001 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1067971
4 June 2001 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1387140
1 March 2001 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1058007
5 June 2000 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1397453
25 October 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1128881
28 July 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451497
22 July 1999 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1107130
4 June 1999 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464893
29 January 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 155137
21 December 1998 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808717
12 November 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806184
31 July 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 795557
23 June 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793041
17 June 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457577
8 April 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762450
21 March 1998 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470707
16 March 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1111152
10 February 1998 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 205615
11 July 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407925
27 June 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112720
27 June 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392721
23 June 1997 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1111659
19 May 1997 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1091605
11 April 1997 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1091729
11 February 1997 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1105993
12 December 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1095048
21 November 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1178680
23 October 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 851082
5 September 1996 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1255315
19 June 1996 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1454345
13 December 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189607
7 August 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402087
30 August 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1178566
26 August 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 866101
13 July 1994 Hull Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448563
20 June 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212382
20 June 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463835
9 February 1994 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1162821
21 December 1993 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 849715
23 September 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 841586
14 September 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 50564
18 August 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1154178
19 July 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354405
1 February 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 144286
25 June 1992 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359429
9 March 1992 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 92627
22 October 1991 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1253682
8 October 1991 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1247356
26 September 1991 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1255589
18 March 1991 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 906029
8 February 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 912267
6 December 1990 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1222441
28 November 1990 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 901195
26 September 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 913477
26 September 1990 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 935537
8 February 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1217509
1 November 1989 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1237743
13 July 1989 Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1350727
3 July 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1209073
26 April 1989 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1038492
13 December 1988 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 897685
27 September 1988 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1044965
7 March 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1338902
11 January 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013509
6 January 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317044
23 December 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008184
14 October 1987 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321913
3 September 1987 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012855
4 March 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321884
5 January 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012127
26 September 1986 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311117
17 July 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301994
17 June 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996823
5 March 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303540
7 October 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991533
22 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287226
14 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982671
13 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982464
10 April 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 974127
27 March 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1279652
23 February 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971518
20 October 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1275192
7 April 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1273243
24 February 1983 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272829
8 December 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278444
30 September 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966947
11 August 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971967
6 July 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966504
7 February 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965241
5 March 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963768

Deficiency record · 134

Electrical › Electrical Distribution System (service) › Wiring
Issued 25 May 2005 Resolved
Remove "Dead Ended" cable from the cable run above the forward end of #1 Gen
Condition: Improper/Lack of Maintenance
Due 10 June 2005
Resolved 5 June 2005
Resolution: Received digital photo and signed statement verifying completion
Lifesaving › Lifeboat › Exhaust Pipe
Issued 25 May 2005 Resolved
Repair or renew leaking exhaust pipe union on #2 lifeboat
Condition: Improper/Lack of Maintenance
Due 10 June 2005
Resolved 5 June 2005
Resolution: Received digital photo and signed statement verifying completion
Electrical › Lighting (service) › Lighting Fixture
Issued 25 May 2005 Resolved
Provide bunk light protective covers in rooms 103, 106, 108
Condition: Improper/Lack of Maintenance
Due 10 June 2005
Resolved 5 June 2005
Resolution: Received digital photo and signed statement verifying completion
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, Positive Displacement
Issued 25 May 2005 Resolved
Trouble shoot and repair cause for the low lube oil pressure in the #1 Electric Generator Diesel Engine. Engine is operating at 2psi, which is below manufacturers minimum oil pressure.
Condition: Unknown
Due 10 June 2005
Resolved 5 June 2005
Resolution: Received digital photo and signed statement verifying completion
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 August 2004 Resolved
Ripped seams on PFD.
Due 19 August 2004
Resolved 19 August 2004
Resolution: Destroyed on sight
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 August 2004 Resolved
Faulty batteries.
Due 19 August 2004
Resolved 19 August 2004
Resolution: Fixed onsight.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 August 2004 Resolved
Gaps between guard rails IVO forward leg.
Due 19 August 2004
Resolved 19 August 2004
Resolution: Added chains on sight.
Construction/Loadline › Hull › Hull Plating
Issued 25 May 2004 Resolved
Prior to August 25, 2004 complete Phase II of SEILOD it the satisfaction of attending USCG Marine Inspector or ABS Surveyor.
Action required: 705 - Other - as specified
Due 25 August 2004
Resolved 21 September 2004
Resolution: Received satisfactory ABS Survey report on completion of Phase II. Phase II completed on Aug 24, 2004
Lifesaving › Lifeboat › Windows/Translucent Panels
Issued 29 July 2003 Resolved
Replace lifeboat windows in #1 lifeboat. Some type of cleaner melted/scratched the windows.
Due 28 August 2003
Resolved 18 August 2003
Resolution: Rcvd E-mail from OIM, [name withheld], with pictures of new window installed.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 29 July 2003 Resolved
Replace expired hydrostatic release for #2 liferaft.
Due 28 August 2003
Resolved 18 August 2003
Resolution: Rcvd E-mail from OIM, [name withheld], with pictures of hydrostatic release.
Construction/Loadline › Structures
Issued 13 August 2002 Resolved
Crop and renew wasted and holed bulkhead in the area of water tight door stbd side 2nd deck. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 September 2002
Resolved 11 September 2002
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 August 2002 Resolved
Update fire and safety plan to show fixed CO2 system for emergency generator. LEGACY COMPONENT DESC: Fire Control Plans
Action required: 705 - Other - as specified
Due 5 June 2004
Resolved 4 August 2004
Fire Fighting
Issued 4 June 2001 Resolved
Replace flexible couplings for discharge of #1 and #2 firepumps.
Condition: Unknown
Due 4 July 2001
Resolved 4 August 2001
Construction/Loadline
Issued 4 June 2001 Resolved
Renew shaker house, surrounding supports, piping and pipe brackets as needed.
Condition: Unknown
Due 4 August 2001
Resolved 4 August 2001
Construction/Loadline
Issued 4 June 2001 Resolved
Renew bow leg walkway angles as identified.
Condition: Unknown
Due 4 July 2001
Resolved 4 August 2001
Lifesaving
Issued 4 June 2001 Resolved
Re-engineer and install platform or brake release mechanism to allow for safe operation of brake on port and starboard lifeboat davits.
Condition: Unknown
Due 4 July 2001
Resolved 4 August 2001
Construction/Loadline
Issued 5 June 2000 Resolved
Conduct proper repairs of severely wasted weld seams/butts on main deck plating just forward of paint locker.
Condition: Unknown
Due 12 July 2000
Resolved 12 July 2000
Lifesaving
Issued 5 June 2000 Resolved
Adjust lifeboat winch brake release mechanisms (counterweight/brake band assy.) on both lifeboats so that winch releases without the need for manualintervention of the counterbalance.
Condition: Unknown
Due 12 July 2000
Resolved 12 July 2000
Construction/Loadline
Issued 5 June 2000 Resolved
Conduct a thorough gauging of the aft (engine room-to-pit room) and forward(pit room-to-pump room) bulkheads; crop and renew where severely wasted (greater than 25 percent of original thickness) is found.
Condition: Unknown
Due 26 July 2000
Resolved 26 July 2000
Lifesaving
Issued 5 June 2000 Resolved
Provide proper operation of drill floor loss-of-purge air indicator on Stratagraph mud logger's monitor. Replace "Chimo" 3-switch control box (beside "Watchdog" mud system monotoring console) with exsplosion proof switch. Install EP type type cable gland on Southland unit red light.
Condition: Unknown
Due 21 June 2000
Resolved 21 June 2000
Construction/Loadline
Issued 5 June 2000 Resolved
Crop and renew wasted structural and reinforcement members at various areason both lifeboat davit structures. Also crop and renew support members underneath lifeboat embarkation deck grating areas.
Condition: Unknown
Due 26 July 2000
Resolved 26 July 2000
Fire Fighting
Issued 28 July 1999 Resolved
Implement training/drill and instruction requirements of 46 CFR 109.213.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Lifesaving
Issued 28 July 1999 Resolved
Redesign mud pit room loss-of-ventilation alarm system so that it alarms upon loss of relative negative pressure differential between mud pit room and pump room. System must operate properly under any and all configurations of pit room/pup room powered ventilation operation.
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Documentation
Issued 28 July 1999 Resolved
Research and include all latest revisions/changes to Operations Manual. Purge all superceded pages/sections. Provide documentation from ABS and/or CG of any/all substantive changes or additional to load calculatons made since CG approval of Revision 4. Ensure original copy of Stability Ltr onbd
Condition: Unknown
Due 27 January 2000
Resolved 27 January 2000
Documentation
Issued 17 June 1998 Resolved
Submit to [name withheld], an EEP for South Pelto Block 013.
Condition: Unknown
Due 22 June 1998
Resolved 25 June 1998
Construction/Loadline
Issued 17 June 1998 Resolved
Complete ABS worklist issued 28MAY98 by Morgan City Surveyor's office.
Condition: Unknown
Due 14 July 1998
Resolved 16 July 1998
Lifesaving
Issued 21 March 1998 Resolved
CONDUCT OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR UNDER A LOAD OF 1.1 TIMESTHE TOTAL MASS OF THE LIFEBOAT WHEN LOADED WITH ITS FULL COMPLEMENT OF PERSONS AND EQUIPMENT.
Condition: Unknown
Due 21 March 1998
Resolved 21 March 1998
Navigation
Issued 11 July 1997 Resolved
REPLACE STERN LIGHT. ENSURE PROPER OPERATION OF ALL NAVIGATION LIGHTS PRIORTO NEXT RIG MOVE.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Lifesaving
Issued 11 July 1997 Resolved
COMPLY WITH EMERGENCY TRAINING AND DRILL REQUIREMENTS OF 46 CFR 109. TRAINPERSONNEL ON USE OF SCBA AND BASIC FIREFIGHTING THEORY.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Fire Fighting
Issued 11 July 1997 Resolved
PLACE PANTS FOR EACH FIREMAN'S OUTFIT ON BOARD.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 11 July 1997 Resolved
REPLACE MUD PIT DOOR.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Lifesaving
Issued 11 July 1997 Resolved
REPAIR GENERAL ALARM BELLS ON BOW, PORT STERN AND RIG FLOOR. ENSURE GENERAL ALARM IS AUDIBLE AT ALL LOCATIONS ON RIG.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 11 July 1997 Resolved
CROP AND RENEW WASTED STBD LIFERAFT DAVIT SUPPORTS AND PLACE INSERT IN SIDESHELL. REPAIRS TO BE COMPLETED TO THE SATISFACTION OF ATTENDING MARINEINSPECTOR. STANDBY VESSEL MUST BE ON LOCATION DURING REPAIRS.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 27 June 1997 Resolved
MAKE REPAIRS TO CRITICAL LEG TO CAN CONNECTIONS IN ACCORDANCE WITH ABS SURVEY REPORT. SUBMIT COPIES OF ACADIANA DIVERS REPORT, WELDERS REPAIR REPORT AND ABS SURVEY REPORT TO MSO MORGAN CITY.
Condition: Unknown
Due 27 June 1997
Resolved 27 June 1997
Construction/Loadline
Issued 27 June 1997 Resolved
REPLACE, HYDROSTATICALLY TEST OR NDT AIR RECEIVER ON DRILL FLOOR. NDT PITTED AREAS ON ALL DRY BULK TANKS.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 27 June 1997 Resolved
OPEN AND CLEAN ALL THROUGH-HULL VALVES FOR COAST GUARD INSPECTION. REPLACEREACH ROD PACKING GLANDS AND PROVE PROPER OPERATION. REPLACE SCREENS ON SUCTION PIPING IN PRELOAD TANK 16 AND PRELOAD TANK 22A.
Condition: Unknown
Due 27 June 1997
Resolved 27 June 1997
Construction/Loadline
Issued 27 June 1997 Resolved
CROP AND RENEW STBD ACCOMMODATION VENT COVER. REPAIR PAINT LOCKER VENT COVER.
Condition: Unknown
Due 11 July 1997
Resolved 11 July 1997
Construction/Loadline
Issued 23 June 1997 Resolved
Complete drydock exam or SEILOD before 30JUN97.
Condition: Unknown
Due 23 June 1997
Resolved 23 June 1997
Electrical
Issued 7 August 1995 Resolved
REPAIR BATTERY E-LIGHTS IN STANDBY GENERATOR SPACE AND AT TOP OF STAIRWAY FROM MAIN DECK TO AIR COMPRESSOR ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 August 1995
Resolved 17 August 1995
Fire Fighting
Issued 7 August 1995 Resolved
PROPERLY INSTALL FIXED CO2 SYSTEM FOR PAINT LOCKER.
Condition: Unknown
Due 15 August 1995
Resolved 17 August 1995
Engineering
Issued 7 August 1995 Resolved
RENEW FUEL HOSE FOR FORKLIFT FUELING STATION.
Condition: Unknown
Due 15 August 1995
Resolved 17 August 1995
Construction/Loadline
Issued 13 July 1994 Resolved
CONDUCT INSPECTION OF SPUD CANS IN THE PRESENCE OF COAST GUARD MARINE INSPECTOR PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Documentation
Issued 20 June 1994 Resolved
CONDUCT SURVEY FOR REISSUANCE OF LOAD LINE CERTIFICATE.
Condition: Unknown
Due 27 June 1994
Resolved 27 June 1994
Electrical
Issued 20 June 1994 Resolved
REPOSITION E-LIGHTS IN QUARTERS TO SHOW PROPER EGRESS; ADDITIONAL LIGHT REQUIRED IN HOSPITAL SPACE; PROVE PROPER OPERATION OF ALL.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Documentation
Issued 20 June 1994 Resolved
SUBMIT FOR APPROVAL TO [name withheld], REVISED FIRE AND SAFETY PLAN INDICATING ALL GENERAL ALARM BELLS, SIRENS AND CONTACT MAKERS.
Condition: Unknown
Due 20 June 1994
Resolved 20 June 1994
Electrical
Issued 19 July 1993 Resolved
TEST THE FOLLOWING SHUTDOWNS: TOTAL RIG, VENTILATION, AND FUEL TRANSFER PUMP. TEST DRAW WORKS BLOWER FAILURE ALARM/INDICATOR._x001C_
Condition: Unknown
Due 19 August 1993
Resolved 18 August 1993
Unknown
Issued 26 September 1991 Resolved
PROVIDE EVIDENCE OF CLASSIFICATION SOCIETY, ANNUAL AND QUADRENNIAL CRANE TESTS.
Condition: Unknown
Due 10 October 1991
Resolved 10 October 1991
Unknown
Issued 26 September 1991 Resolved
CONDUCT U.S.C.G. CREDIT DRYDOCK EXAM PRIOR TO 31 OCT 91.
Condition: Unknown
Due 10 October 1991
Resolved 10 October 1991
Unknown
Issued 26 September 1991 Resolved
PROVIDE APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 10 October 1991
Resolved 10 October 1991
Unknown
Issued 6 December 1990 Resolved
SUBMIT REVISIONS TO OPERATING MANUAL PER MSO PORT ARTHUR LETTER OF 06DEC90.
Condition: Unknown
Due 6 December 1990
Resolved 6 December 1990
Unknown
Issued 26 September 1990 Resolved
MAKE AVAILABLE FOR INTERNAL EXAMINATION BY A COAST GUARD MARINE INSPECTOR DRY BULK TANKS #1, 2 & 3.
Condition: Unknown
Due 26 September 1990
Resolved 26 September 1990
Unknown
Issued 26 September 1990 Resolved
PROVIDE COPY OF OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 26 September 1990
Resolved 26 September 1990
Construction/Loadline
Issued 1 November 1989 Resolved
CONDUCT HYDRO TEST OF AIR RECIEVER UNDER DRILL FLOOR TO 1.5 TIMES MAWP IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Lifesaving
Issued 1 November 1989 Resolved
MAKE PERMANANT REPAIRS TO APPROX 4 INCH FRACTURE IN INTERIOR OF NO. 1. LIFEBOAT.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Fire Fighting
Issued 1 November 1989 Resolved
MAKE PERMANENT REPAIRS TO TEMPORARY REPAIRED AREA OF FIRE MAIN IN VICINITY OF NO. 1 FIRE PUMP.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Fire Fighting
Issued 1 November 1989 Resolved
EFFECT PERMANENT REPAIRS TO FIRE PUMPS SO AS TO ACHIEVE 50 PSI AT TWO OUTLETS.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Unknown
Issued 27 September 1988 Resolved
OPEN FOR INTERNAL EXAMINATION THE FOUR BULK STORAGE TANKS AND TEST THE RELIEF VALVES.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Unknown
Issued 27 September 1988 Resolved
OPEN FOR INTERNAL EXAMINATION THE DRILL FLOOR AIR RECEIVER AND TEST THE RELIEF VALVE.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Electrical
Issued 27 September 1988 Resolved
CONDUCT OPERATIONAL TEST OF THE REMOTE STOP FOR #1, 2, AND 3 S/S GENERATOR.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Unknown
Issued 27 September 1988 Resolved
REMOVE TEMPORARY DIESEL FUEL STORAGE TANK AND HOSES AND INSTALL PERMANENT DIESEL FUEL STORAGE TANK AND PIPING FOR DIESEL AIR COMPRESSOR.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Electrical
Issued 27 September 1988 Resolved
REMOVE "PUSH-ON" TYPE HOSES FROM EMERGENCY GENERATOR PRIME MOVE AND INSTALLCOAST GUARD ACCEPTABLE TYPE.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Documentation
Issued 27 September 1988 Resolved
PROVIDE ORIGINAL MARINE DOCUMENT ON BOARD THE VESSEL.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Accommodation/Occupational Safety
Issued 27 September 1988 Resolved
INSTALL APPROVED MARINE SANITATION DEVICE.
Condition: Unknown
Due 27 September 1988
Resolved 27 September 1988
Construction/Loadline
Issued 23 December 1987 Resolved
MAKE AVAILABLE FOR INSPECTION, ALL REPAIRS AND MODIFICATIONS DONE TO HELO DECK AND BOW AREA DAMAGED DURING FIRE. REF: NVC 4-78 PARA. 3(D)(1).
Condition: Unknown
Due 23 December 1987
Resolved 23 December 1987
Construction/Loadline
Issued 23 December 1987 Resolved
INSTALL NON-SKID DECK COVERING ON HELICOPTER DECK. (PARA 3(D) OF NVC 4-78) REF: NVC 4-78 CH-1 AND 46 CFR 108.235(D)
Condition: Unknown
Due 23 December 1987
Resolved 23 December 1987
Electrical
Issued 3 September 1987 Resolved
PROPERLY SECURE WIRE CABLES ABOVE THE SHALE SHAKER AND DE GASSER AREA
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Lifesaving
Issued 3 September 1987 Resolved
REPAIR BROKEN LIFELINE ON STBD LIFEBOAT NO.1
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Construction/Loadline
Issued 3 September 1987 Resolved
PAINT RIGS NAME IN CONTRASTING COLOR TO THE HULL, ON THE STERN
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Lifesaving
Issued 3 September 1987 Resolved
PROVIDE INT. LIGHTING FOR PORT LIFEBOAT.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Electrical
Issued 3 September 1987 Resolved
INSTALL LOSS OF VENTILLATION PADDLE SWITCHES ON BOTH MUD PIT VENTILATORS AND MAKE ALARM OPERABLE.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Fire Fighting
Issued 3 September 1987 Resolved
REPLACE ALL EX-607 HOSES ON SEMI PORTABLE AND PORTABLE FIRE EXTINGUISHER THAT HAVE A MANUFACTURE DATE BETWEEN 1/77 AND 4/83 AND OTHER 607 HOSES WHOSDATE CANT BE DETERMINED.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Electrical
Issued 3 September 1987 Resolved
PROPERLY INSTALL JUNCTION KBOX AND ELECTRICAL CABLE THAT RUNS FROM THE PORTCRANE TO THE CRANES REMOTE OPERATING STATION.
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Deck/Cargo
Issued 3 September 1987 Resolved
REPAIR MARK LOAD METER IN THE STBD, FWD CRANES REMOTE OPERATING STATION
Condition: Unknown
Due 3 September 1987
Resolved 3 September 1987
Lifesaving
Issued 5 January 1987 Resolved
REDUCE MANNING TO 44 PERSONS UNTIL REPAIRS ARE COMPLETED ON THE #1 LIFEBOATS BRAKE.
Condition: Unknown
Due 5 January 1987
Resolved 5 January 1987
Lifesaving
Issued 26 September 1986 Resolved
BOTH 44 MAN LIFEBOATS (AND) DAVIT ASSEMBLY TO BE WEIGHT TESTED.
Condition: Unknown
Due 26 September 1986
Resolved 26 September 1986
Fire Fighting
Issued 5 March 1986 Resolved
DUE TO DETERIORATION HYDROSTATIC TEST CO2 BOTTLE LOCATED ON PAINT LOCKER; OR REPLACE.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Electrical
Issued 5 March 1986 Resolved
PROVIDE RUBBER MAT IN FRONT OF SWITCHBOARD IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986 Resolved
PROVIDE RELIEF VALVES ON DISCHARGE SIDE OF FIRE PUMP'S OR PROVE THAT ADDITIONAL FIRE PUMP PRESSURE IS NEEDED TO PROVIDE 50 PSI AT THE HIGHEST HOSE STATION.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Construction/Loadline
Issued 5 March 1986 Resolved
FREE DOGS ON WATERTIGHT DOOR TO MUD PIT ROOM.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Construction/Loadline
Issued 5 March 1986 Resolved
REPAIR UNALIGNED DOGS (OR REPLACE MISSING DOGS) ON HATCH COVER TO THE COMPRESSOR ROOM HATCH LOCATED ON THE MAIN DECK.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Construction/Loadline
Issued 5 March 1986 Resolved
REPLACE FRACTURED DOGS FITTED ON THE WATERTIGHT DOOR LOCATED ON THE AFT SIDE OF THE HOUSE, NEAR THE BOW LEG. (THIS W/T DOOR IS TO A FOUR (4) MAN SLEEPING COMPARTMENT).
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Lifesaving
Issued 5 March 1986 Resolved
CLEAN ELECTRICAL CONTACTS IN THE WINCH CONTROL BOXES TO BOTH LIFE BOATS.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Accommodation/Occupational Safety
Issued 5 March 1986 Resolved
PROVIDE DEADMAN NOZZLE FOR THE DRESSER ATLAS LOGGING UNIT REFUELING HOSE.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Construction/Loadline
Issued 5 March 1986 Resolved
REPLACE BROKEN DOGS ON DECK HATCH TO SACK ROOM.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Lifesaving
Issued 5 March 1986 Resolved
PROVIDE ONE ADDITIONAL SERVICE LINE AND ONE ADDITIONAL SERVICE PROJECTILE FOR THE LINE THROWING GUN.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986 Resolved
REPAIR GENERAL ALARM BELLS IN THE ENGINE ROOM AND DRILL FLOOR.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Engineering
Issued 5 March 1986 Resolved
PROVIDE A REMOTE FUEL SHUTOFF FOR THE EMERGENCY GENERATOR LOCATED OUTSIDE THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Construction/Loadline
Issued 5 March 1986 Resolved
REPAIR NUTS AND BOLTS TO DECK MANHOLE COVER TO THE 22A TANK. MOST OF THE BOLTS AND NUTS ARE MISSING.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Construction/Loadline
Issued 5 March 1986 Resolved
REPAIR PACKING GLANDS AT DECK LEVEL TO THE DUMP VALVES AS FOLLOWS: PL#28,162,8.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Accommodation/Occupational Safety
Issued 5 March 1986 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION THE THREE HOT WATER HEATERS OR INSTALL RELIEF VALVES RATED AT 100 PSI OR LESS/AND TEMPERATURE LESS THAN 200 F 46 CFR 54.01-15.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Electrical
Issued 5 March 1986 Resolved
PROVE SATISFACTORY OPERATION OF THE LOW LUBE OIL ALARM ON THE #3 EMD.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Electrical
Issued 5 March 1986 Resolved
PROVE SATISFACTORY OPERATION OF THE OVERSPEED ALARM ON THE #1 EMD.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Deck/Cargo
Issued 5 March 1986 Resolved
PROVIDE A FLAME SCREEN ON GOOSE NECK ON FUEL TANK TO EMERGENCY GENERATOR.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Lifesaving
Issued 5 March 1986 Resolved
REPAIR OUTBOARD LIFE LINE ON LIFEBOAT NO.2.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Deck/Cargo
Issued 5 March 1986 Resolved
HYDROSTATICALLY TEST OR REPLACE FUEL HOSE LOCATED ON THE RIG'S PORT SIDE; 33CFR155.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Documentation
Issued 5 March 1986 Resolved
PROVIDE ONBOARD THE REQUIRED NUMBER OF LIFEBOAT MAN PER THE VESSEL'S COI. COMPLIANCE DATE IS 12MAR86.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Lifesaving
Issued 5 March 1986 Resolved
PROVIDE SMOKE FOR ONE RING LIFE BUOY.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Electrical
Issued 5 March 1986 Resolved
REPLACE BROKEN GLASS TUBES ON OVERHEAD FLAMESCENT LIGHTS IN RADIATOR AREA ON MAIN DECK AFT.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Lifesaving
Issued 5 March 1986 Resolved
PROVIDE AN ADDITIONAL 20 TRIANGULAR BANDAGES FOR THE RIG'S FIRST AID KIT.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Lifesaving
Issued 5 March 1986 Resolved
MAKE OPERATIONAL THE CABLE RELEASE MECHANISM AT BOTH LIFE RAFT STATIONS.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986 Resolved
SERVICE DRY CHEM. FIRE EXT. AT STATION #38 OR REPLACE.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Construction/Loadline
Issued 5 March 1986 Resolved
REPAIR/ADJUST HATCH ON EXPANSION TRUNK ON PRELOAD TANK 29. THE HATCH CAN NOT BE DOGGED DOWN FOR WATERTIGHT INTEGRITY.
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Fire Fighting
Issued 5 March 1986 Resolved
REPAIR INOPERABLE GENERAL ALARM BELL LOCATED ON THE AFT BULKHEAD OF THE QUARTERS (I.E. SIDE NEAR HELO-DECK).
Condition: Unknown
Due 5 March 1986
Resolved 5 March 1986
Deck/Cargo
Issued 13 February 1985 Resolved
TEST AND MARK THE FUEL OIL HOSES AS PER 33 CFR 155.800.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Deck/Cargo
Issued 13 February 1985 Resolved
PROVIDE A FUELING CAN FOR THE FORK TRUCK AS PER 46 CFR 109.537.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Lifesaving
Issued 13 February 1985 Resolved
REPAIR THE LIFELINE ON THE STARBOARD BOAT. 46 CFR 108.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Navigation
Issued 13 February 1985 Resolved
PROVIDE A MANUAL CONTROL FOR THE WHISTLE / FOG HORN. RULE 33(A) INTERNATIONAL REGULATIONS FOR PREVENTING COLLISIONS AT SEA.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Engineering
Issued 13 February 1985 Resolved
PROVIDE RELIEF VALVES FOR THE #2 AND #3 AIR RECIEVERS. 46 CFR 54.15.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Engineering
Issued 13 February 1985 Resolved
PROVIDE RELIEF VALVES FOR THE #3 AND #4 BULK TANKS. 46 CFR 54.15.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Electrical
Issued 13 February 1985 Resolved
CONDUCT AND LOG THE TEST OF THE EMERGENCY GENERATOR, AS PER 46 CFR 109.211.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Lifesaving
Issued 13 February 1985 Resolved
PROVIDE TWELVE HAND HELD RED FLARES FOR THE STARBOARD BOAT. 46 CFR 108.501.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Fire Fighting
Issued 13 February 1985 Resolved
MAKE SERVICEABLE THE FIRE NOZZLES AND FOG APPLICATORS IN THE MACHINERY SPACES. 46 CFR 108.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Electrical
Issued 13 February 1985 Resolved
PLACE THE TELEPHONE TEST PANEL IN AN ENCLOSURE TO PREVENT A SHOCK HAZARD. 46 CFR 111.55.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Construction/Loadline
Issued 13 February 1985 Resolved
PROVIDE CONTAIMENT OF AT LEASE ONE-HALF BARREL AROUND THE FUEL OIL VENTS ASPER 33 CFR 155.320.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Navigation
Issued 13 February 1985 Resolved
INSTALL A STERN ANCHOR LIGHT, RULE 30 INTERNATIONAL REGULATIONS FOR PREVENTING COLLISIONS AT SEA.
Condition: Unknown
Due 13 February 1985
Resolved 13 February 1985
Deck/Cargo
Issued 23 February 1984 Resolved
PROVIDE ONBOARD THE VESSEL AT THE STBD. AFT CRANE CONTROL BOX ,A LOAD CHART
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Construction/Loadline
Issued 23 February 1984 Resolved
PROPERLY SEAL BULKHEAD PENETRATIONS IN MUD PIT ROOM, AIR COMPRESSER ROOM AND MECHANICS SHOP.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Electrical
Issued 23 February 1984 Resolved
PROPEERLY SECURE AFTER SHALE SHAKER ELECTRICAL SUPPLY J-BOX TO OVERHEAD.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Electrical
Issued 23 February 1984 Resolved
PROVIDE SEALED EYS FITTINGS FOR THE AFTER SHALE SHAKER MOTOR AND ASSOCIATEDJ-BOX ON OVERHEAD.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Electrical
Issued 23 February 1984 Resolved
PROVIDE LOSS OF VENTILATION ALARM IN A MANNED LOCATION FOR MUD PIT ROOM VENTILATION SYSTEM.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Construction/Loadline
Issued 23 February 1984 Resolved
PROVIDE GATE VALVES ON ALL SOUNDING TUBES BELOW THE FREEBOARD DECK.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Unknown
Issued 23 February 1984 Resolved
TOTAL PERSONSALLOWED ON BOARD THE VESSEL IS NOT TO EXCEED 64 PENDING IN- STALLATION OF DAVIT LAUNCHED LIFERAFTS PRESENTLY BEING SERVICED.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Fire Fighting
Issued 23 February 1984 Resolved
RENEW MISSING AIR PACK BOTTLES FOR FIREMANS OUTFITS.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Lifesaving
Issued 23 February 1984 Resolved
RENEW OUTDATED HAND HELD FLARES IN THE PORT LIFEBOAT.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Lifesaving
Issued 23 February 1984 Resolved
PROVIDE ON BOARD THE VESSEL IN THE STBD LIFEBOAT, 23 QTS. OF WATER TO RE- NEW OUTDATED WATER.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Electrical
Issued 23 February 1984 Resolved
REPAIR OR RENEW INOPERATIVE EMERGENCY LIGHTS AS NEEDED.
Condition: Unknown
Due 23 February 1984
Resolved 23 February 1984
Electrical
Issued 11 August 1982 Resolved
TIE AIR CONDITIONER UNITS TO EMERGENCY VENTILATION SHUT DOWN FOR QUARTERS. 46 CFR 111.80-10
Condition: Unknown
Due 11 August 1982
Resolved 11 August 1982
Lifesaving
Issued 11 August 1982 Resolved
PROVIDE EMERGENCY LIGHTING FOR BOTH LIFEBOAT STATIONS. NVC 4-78 3D(10)(2)
Condition: Unknown
Due 11 August 1982
Resolved 11 August 1982
Fire Fighting
Issued 11 August 1982 Resolved
SERVICE FIRE FIGHTING EQUIPMENT AS REQUIRED BY 46 CFR 107.235 AND 46 CFR 109.223.
Condition: Unknown
Due 11 August 1982
Resolved 11 August 1982
Unknown
Issued 7 February 1982 Resolved
MAKE FOUR P-TANKS AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 7 February 1982
Resolved 7 February 1982
Lifesaving
Issued 7 February 1982 Resolved
WEIGHT TEST INFLATABLE LIFERAFT DAVITS.
Condition: Unknown
Due 7 February 1982
Resolved 7 February 1982
Unknown
Issued 7 February 1982 Resolved
MAKE DRILL FLOOR AIR RECIEVER AVAIABLE FOR 1 1/2 MAWP HYDROSTATIC TEST.
Condition: Unknown
Due 7 February 1982
Resolved 7 February 1982
Electrical
Issued 7 February 1982 Resolved
AIR PURGE ROOM AT STBD AFT SIDE OF DRILL FLOOR. (WITH PROPER DOOR CLOSEUP AND VENTILATION ALARM).
Condition: Unknown
Due 7 February 1982
Resolved 7 February 1982
Lifesaving
Issued 7 February 1982 Resolved
PROVIDE CUP 20 MAN LIFERAFT.
Condition: Unknown
Due 7 February 1982
Resolved 7 February 1982

Casualty record · 1

8 October 2004Routine · role: Involved in a Marine Casualty · 1 injured · activity 2225042
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.