← All vessels
ENSCO 83
ENSCO 83 is a 1979 mobile offshore drilling unit. The Coast Guard has recorded 119 inspections since 1981, most recently in June 2016, along with 134 deficiencies and 1 casualty investigation in 2004.
Records from 1981 to 2016. Most recent: inspection, 13 June 2016.
- Built
- 1979
- Last inspected
- 13 June 2016
- Documentation
- Not in the documentation file of 10 September 2026
- Inspections
- 119
- Deficiencies
- 134 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2004
Identity
605536
8753768 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
A8KW8
52842
Flag
LIBERIA
—
Maury page id
psix-52842
Inspections, by type
…with no type recorded47
Years with a record
30 calendar years (1981–2016)
The 119 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it4483 - Convention (Subpart B), Gross Ton
1344 - Convention (Subpart B), Net Ton
1344 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 119
13 June 2016
Administrative Inspection
Administrative · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 5905954
20 April 2009
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3456557
14 April 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3452491
2 April 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3444766
21 October 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3348756
11 August 2008
COC-MODU Annual
Type not classified · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3295674
10 March 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3161410
17 January 2008
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3132227
24 May 2007
COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2938997
15 August 2006
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2747495
25 May 2005
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2367740
8 March 2005
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2305763
8 October 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2225042
19 August 2004
Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2161942
25 May 2004
Underwater Inspection in lieu of Drydock
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2079093
24 May 2004
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2076990
15 February 2004
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2012921
29 July 2003
Administrative Inspection · Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1924698
7 July 2003
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1838689
27 April 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1808597
27 March 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1770188
20 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1760079
1 October 2002
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1682727
13 August 2002
Deficiency Check · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1660674
4 August 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1660686
10 June 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1635812
4 April 2002
Administrative Inspection
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1601059
27 January 2002
Hull Examination · Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1479466
25 January 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1481336
26 June 2001
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1067971
4 June 2001
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1387140
1 March 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1058007
5 June 2000
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1397453
25 October 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1128881
28 July 1999
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1451497
22 July 1999
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1107130
4 June 1999
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464893
29 January 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 155137
21 December 1998
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 808717
12 November 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 806184
31 July 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 795557
23 June 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 793041
17 June 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457577
8 April 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 762450
21 March 1998
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470707
16 March 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1111152
10 February 1998
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 205615
11 July 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407925
27 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1112720
27 June 1997
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392721
23 June 1997
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1111659
19 May 1997
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1091605
11 April 1997
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1091729
11 February 1997
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1105993
12 December 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1095048
21 November 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1178680
23 October 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 851082
5 September 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1255315
19 June 1996
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1454345
13 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189607
7 August 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402087
30 August 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1178566
26 August 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 866101
13 July 1994
Hull Examination · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448563
20 June 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212382
20 June 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463835
9 February 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1162821
21 December 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 849715
23 September 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 841586
14 September 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 50564
18 August 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1154178
19 July 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354405
1 February 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 144286
25 June 1992
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359429
9 March 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 92627
22 October 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1253682
8 October 1991
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1247356
26 September 1991
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1255589
18 March 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 906029
8 February 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 912267
6 December 1990
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1222441
28 November 1990
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 901195
26 September 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 913477
26 September 1990
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 935537
8 February 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1217509
1 November 1989
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1237743
13 July 1989
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1350727
3 July 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1209073
26 April 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1038492
13 December 1988
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 897685
27 September 1988
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1044965
7 March 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1338902
11 January 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013509
6 January 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1317044
23 December 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008184
14 October 1987
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321913
3 September 1987
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012855
4 March 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321884
5 January 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1012127
26 September 1986
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1311117
17 July 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301994
17 June 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 996823
5 March 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303540
7 October 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991533
22 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287226
14 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982671
13 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 982464
10 April 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 974127
27 March 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1279652
23 February 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971518
20 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1275192
7 April 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1273243
24 February 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1272829
8 December 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278444
30 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966947
11 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971967
6 July 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966504
7 February 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965241
5 March 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963768
Deficiency record · 134
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 May 2005
Resolved
Remove "Dead Ended" cable from the cable run above the forward end of #1 Gen
Lifesaving › Lifeboat › Exhaust Pipe
Issued 25 May 2005
Resolved
Repair or renew leaking exhaust pipe union on #2 lifeboat
Electrical › Lighting (service) › Lighting Fixture
Issued 25 May 2005
Resolved
Provide bunk light protective covers in rooms 103, 106, 108
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Pump, Positive Displacement
Issued 25 May 2005
Resolved
Trouble shoot and repair cause for the low lube oil pressure in the #1 Electric Generator Diesel Engine. Engine is operating at 2psi, which is below manufacturers minimum oil pressure.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 19 August 2004
Resolved
Ripped seams on PFD.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 19 August 2004
Resolved
Faulty batteries.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 August 2004
Resolved
Gaps between guard rails IVO forward leg.
Construction/Loadline › Hull › Hull Plating
Issued 25 May 2004
Resolved
Prior to August 25, 2004 complete Phase II of SEILOD it the satisfaction of attending USCG Marine Inspector or ABS Surveyor.
Lifesaving › Lifeboat › Windows/Translucent Panels
Issued 29 July 2003
Resolved
Replace lifeboat windows in #1 lifeboat. Some type of cleaner melted/scratched the windows.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 29 July 2003
Resolved
Replace expired hydrostatic release for #2 liferaft.
Construction/Loadline › Structures
Issued 13 August 2002
Resolved
Crop and renew wasted and holed bulkhead in the area of water tight door stbd side 2nd deck. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 August 2002
Resolved
Update fire and safety plan to show fixed CO2 system for emergency generator. LEGACY COMPONENT DESC: Fire Control Plans
Fire Fighting
Issued 4 June 2001
Resolved
Replace flexible couplings for discharge of #1 and #2 firepumps.
Construction/Loadline
Issued 4 June 2001
Resolved
Renew shaker house, surrounding supports, piping and pipe brackets as needed.
Construction/Loadline
Issued 4 June 2001
Resolved
Renew bow leg walkway angles as identified.
Lifesaving
Issued 4 June 2001
Resolved
Re-engineer and install platform or brake release mechanism to allow for safe operation of brake on port and starboard lifeboat davits.
Construction/Loadline
Issued 5 June 2000
Resolved
Conduct proper repairs of severely wasted weld seams/butts on main deck plating just forward of paint locker.
Lifesaving
Issued 5 June 2000
Resolved
Adjust lifeboat winch brake release mechanisms (counterweight/brake band assy.) on both lifeboats so that winch releases without the need for manualintervention of the counterbalance.
Construction/Loadline
Issued 5 June 2000
Resolved
Conduct a thorough gauging of the aft (engine room-to-pit room) and forward(pit room-to-pump room) bulkheads; crop and renew where severely wasted (greater than 25 percent of original thickness) is found.
Lifesaving
Issued 5 June 2000
Resolved
Provide proper operation of drill floor loss-of-purge air indicator on Stratagraph mud logger's monitor. Replace "Chimo" 3-switch control box (beside "Watchdog" mud system monotoring console) with exsplosion proof switch. Install EP type type cable gland on Southland unit red light.
Construction/Loadline
Issued 5 June 2000
Resolved
Crop and renew wasted structural and reinforcement members at various areason both lifeboat davit structures. Also crop and renew support members underneath lifeboat embarkation deck grating areas.
Fire Fighting
Issued 28 July 1999
Resolved
Implement training/drill and instruction requirements of 46 CFR 109.213.
Lifesaving
Issued 28 July 1999
Resolved
Redesign mud pit room loss-of-ventilation alarm system so that it alarms upon loss of relative negative pressure differential between mud pit room and pump room. System must operate properly under any and all configurations of pit room/pup room powered ventilation operation.
Documentation
Issued 28 July 1999
Resolved
Research and include all latest revisions/changes to Operations Manual. Purge all superceded pages/sections. Provide documentation from ABS and/or CG of any/all substantive changes or additional to load calculatons made since CG approval of Revision 4. Ensure original copy of Stability Ltr onbd
Documentation
Issued 17 June 1998
Resolved
Submit to [name withheld], an EEP for South Pelto Block 013.
Construction/Loadline
Issued 17 June 1998
Resolved
Complete ABS worklist issued 28MAY98 by Morgan City Surveyor's office.
Lifesaving
Issued 21 March 1998
Resolved
CONDUCT OPERATIONAL TEST OF LIFEBOAT RELEASE GEAR UNDER A LOAD OF 1.1 TIMESTHE TOTAL MASS OF THE LIFEBOAT WHEN LOADED WITH ITS FULL COMPLEMENT OF PERSONS AND EQUIPMENT.
Navigation
Issued 11 July 1997
Resolved
REPLACE STERN LIGHT. ENSURE PROPER OPERATION OF ALL NAVIGATION LIGHTS PRIORTO NEXT RIG MOVE.
Lifesaving
Issued 11 July 1997
Resolved
COMPLY WITH EMERGENCY TRAINING AND DRILL REQUIREMENTS OF 46 CFR 109. TRAINPERSONNEL ON USE OF SCBA AND BASIC FIREFIGHTING THEORY.
Fire Fighting
Issued 11 July 1997
Resolved
PLACE PANTS FOR EACH FIREMAN'S OUTFIT ON BOARD.
Construction/Loadline
Issued 11 July 1997
Resolved
REPLACE MUD PIT DOOR.
Lifesaving
Issued 11 July 1997
Resolved
REPAIR GENERAL ALARM BELLS ON BOW, PORT STERN AND RIG FLOOR. ENSURE GENERAL ALARM IS AUDIBLE AT ALL LOCATIONS ON RIG.
Construction/Loadline
Issued 11 July 1997
Resolved
CROP AND RENEW WASTED STBD LIFERAFT DAVIT SUPPORTS AND PLACE INSERT IN SIDESHELL. REPAIRS TO BE COMPLETED TO THE SATISFACTION OF ATTENDING MARINEINSPECTOR. STANDBY VESSEL MUST BE ON LOCATION DURING REPAIRS.
Construction/Loadline
Issued 27 June 1997
Resolved
MAKE REPAIRS TO CRITICAL LEG TO CAN CONNECTIONS IN ACCORDANCE WITH ABS SURVEY REPORT. SUBMIT COPIES OF ACADIANA DIVERS REPORT, WELDERS REPAIR REPORT AND ABS SURVEY REPORT TO MSO MORGAN CITY.
Construction/Loadline
Issued 27 June 1997
Resolved
REPLACE, HYDROSTATICALLY TEST OR NDT AIR RECEIVER ON DRILL FLOOR. NDT PITTED AREAS ON ALL DRY BULK TANKS.
Construction/Loadline
Issued 27 June 1997
Resolved
OPEN AND CLEAN ALL THROUGH-HULL VALVES FOR COAST GUARD INSPECTION. REPLACEREACH ROD PACKING GLANDS AND PROVE PROPER OPERATION. REPLACE SCREENS ON SUCTION PIPING IN PRELOAD TANK 16 AND PRELOAD TANK 22A.
Construction/Loadline
Issued 27 June 1997
Resolved
CROP AND RENEW STBD ACCOMMODATION VENT COVER. REPAIR PAINT LOCKER VENT COVER.
Construction/Loadline
Issued 23 June 1997
Resolved
Complete drydock exam or SEILOD before 30JUN97.
Electrical
Issued 7 August 1995
Resolved
REPAIR BATTERY E-LIGHTS IN STANDBY GENERATOR SPACE AND AT TOP OF STAIRWAY FROM MAIN DECK TO AIR COMPRESSOR ROOM._x001C_ _x001C_ _x001C_
Fire Fighting
Issued 7 August 1995
Resolved
PROPERLY INSTALL FIXED CO2 SYSTEM FOR PAINT LOCKER.
Engineering
Issued 7 August 1995
Resolved
RENEW FUEL HOSE FOR FORKLIFT FUELING STATION.
Construction/Loadline
Issued 13 July 1994
Resolved
CONDUCT INSPECTION OF SPUD CANS IN THE PRESENCE OF COAST GUARD MARINE INSPECTOR PRIOR TO NEXT RIG MOVE.
Documentation
Issued 20 June 1994
Resolved
CONDUCT SURVEY FOR REISSUANCE OF LOAD LINE CERTIFICATE.
Electrical
Issued 20 June 1994
Resolved
REPOSITION E-LIGHTS IN QUARTERS TO SHOW PROPER EGRESS; ADDITIONAL LIGHT REQUIRED IN HOSPITAL SPACE; PROVE PROPER OPERATION OF ALL.
Documentation
Issued 20 June 1994
Resolved
SUBMIT FOR APPROVAL TO [name withheld], REVISED FIRE AND SAFETY PLAN INDICATING ALL GENERAL ALARM BELLS, SIRENS AND CONTACT MAKERS.
Electrical
Issued 19 July 1993
Resolved
TEST THE FOLLOWING SHUTDOWNS: TOTAL RIG, VENTILATION, AND FUEL TRANSFER PUMP. TEST DRAW WORKS BLOWER FAILURE ALARM/INDICATOR._x001C_
Unknown
Issued 26 September 1991
Resolved
PROVIDE EVIDENCE OF CLASSIFICATION SOCIETY, ANNUAL AND QUADRENNIAL CRANE TESTS.
Unknown
Issued 26 September 1991
Resolved
CONDUCT U.S.C.G. CREDIT DRYDOCK EXAM PRIOR TO 31 OCT 91.
Unknown
Issued 26 September 1991
Resolved
PROVIDE APPROVED CONSTRUCTION PORTFOLIO.
Unknown
Issued 6 December 1990
Resolved
SUBMIT REVISIONS TO OPERATING MANUAL PER MSO PORT ARTHUR LETTER OF 06DEC90.
Unknown
Issued 26 September 1990
Resolved
MAKE AVAILABLE FOR INTERNAL EXAMINATION BY A COAST GUARD MARINE INSPECTOR DRY BULK TANKS #1, 2 & 3.
Unknown
Issued 26 September 1990
Resolved
PROVIDE COPY OF OIL TRANSFER PROCEDURES.
Construction/Loadline
Issued 1 November 1989
Resolved
CONDUCT HYDRO TEST OF AIR RECIEVER UNDER DRILL FLOOR TO 1.5 TIMES MAWP IN PRESENCE OF USCG MARINE INSPECTOR.
Lifesaving
Issued 1 November 1989
Resolved
MAKE PERMANANT REPAIRS TO APPROX 4 INCH FRACTURE IN INTERIOR OF NO. 1. LIFEBOAT.
Fire Fighting
Issued 1 November 1989
Resolved
MAKE PERMANENT REPAIRS TO TEMPORARY REPAIRED AREA OF FIRE MAIN IN VICINITY OF NO. 1 FIRE PUMP.
Fire Fighting
Issued 1 November 1989
Resolved
EFFECT PERMANENT REPAIRS TO FIRE PUMPS SO AS TO ACHIEVE 50 PSI AT TWO OUTLETS.
Unknown
Issued 27 September 1988
Resolved
OPEN FOR INTERNAL EXAMINATION THE FOUR BULK STORAGE TANKS AND TEST THE RELIEF VALVES.
Unknown
Issued 27 September 1988
Resolved
OPEN FOR INTERNAL EXAMINATION THE DRILL FLOOR AIR RECEIVER AND TEST THE RELIEF VALVE.
Electrical
Issued 27 September 1988
Resolved
CONDUCT OPERATIONAL TEST OF THE REMOTE STOP FOR #1, 2, AND 3 S/S GENERATOR.
Unknown
Issued 27 September 1988
Resolved
REMOVE TEMPORARY DIESEL FUEL STORAGE TANK AND HOSES AND INSTALL PERMANENT DIESEL FUEL STORAGE TANK AND PIPING FOR DIESEL AIR COMPRESSOR.
Electrical
Issued 27 September 1988
Resolved
REMOVE "PUSH-ON" TYPE HOSES FROM EMERGENCY GENERATOR PRIME MOVE AND INSTALLCOAST GUARD ACCEPTABLE TYPE.
Documentation
Issued 27 September 1988
Resolved
PROVIDE ORIGINAL MARINE DOCUMENT ON BOARD THE VESSEL.
Accommodation/Occupational Safety
Issued 27 September 1988
Resolved
INSTALL APPROVED MARINE SANITATION DEVICE.
Construction/Loadline
Issued 23 December 1987
Resolved
MAKE AVAILABLE FOR INSPECTION, ALL REPAIRS AND MODIFICATIONS DONE TO HELO DECK AND BOW AREA DAMAGED DURING FIRE. REF: NVC 4-78 PARA. 3(D)(1).
Construction/Loadline
Issued 23 December 1987
Resolved
INSTALL NON-SKID DECK COVERING ON HELICOPTER DECK. (PARA 3(D) OF NVC 4-78) REF: NVC 4-78 CH-1 AND 46 CFR 108.235(D)
Electrical
Issued 3 September 1987
Resolved
PROPERLY SECURE WIRE CABLES ABOVE THE SHALE SHAKER AND DE GASSER AREA
Lifesaving
Issued 3 September 1987
Resolved
REPAIR BROKEN LIFELINE ON STBD LIFEBOAT NO.1
Construction/Loadline
Issued 3 September 1987
Resolved
PAINT RIGS NAME IN CONTRASTING COLOR TO THE HULL, ON THE STERN
Lifesaving
Issued 3 September 1987
Resolved
PROVIDE INT. LIGHTING FOR PORT LIFEBOAT.
Electrical
Issued 3 September 1987
Resolved
INSTALL LOSS OF VENTILLATION PADDLE SWITCHES ON BOTH MUD PIT VENTILATORS AND MAKE ALARM OPERABLE.
Fire Fighting
Issued 3 September 1987
Resolved
REPLACE ALL EX-607 HOSES ON SEMI PORTABLE AND PORTABLE FIRE EXTINGUISHER THAT HAVE A MANUFACTURE DATE BETWEEN 1/77 AND 4/83 AND OTHER 607 HOSES WHOSDATE CANT BE DETERMINED.
Electrical
Issued 3 September 1987
Resolved
PROPERLY INSTALL JUNCTION KBOX AND ELECTRICAL CABLE THAT RUNS FROM THE PORTCRANE TO THE CRANES REMOTE OPERATING STATION.
Deck/Cargo
Issued 3 September 1987
Resolved
REPAIR MARK LOAD METER IN THE STBD, FWD CRANES REMOTE OPERATING STATION
Lifesaving
Issued 5 January 1987
Resolved
REDUCE MANNING TO 44 PERSONS UNTIL REPAIRS ARE COMPLETED ON THE #1 LIFEBOATS BRAKE.
Lifesaving
Issued 26 September 1986
Resolved
BOTH 44 MAN LIFEBOATS (AND) DAVIT ASSEMBLY TO BE WEIGHT TESTED.
Fire Fighting
Issued 5 March 1986
Resolved
DUE TO DETERIORATION HYDROSTATIC TEST CO2 BOTTLE LOCATED ON PAINT LOCKER; OR REPLACE.
Electrical
Issued 5 March 1986
Resolved
PROVIDE RUBBER MAT IN FRONT OF SWITCHBOARD IN EMERGENCY GENERATOR ROOM.
Fire Fighting
Issued 5 March 1986
Resolved
PROVIDE RELIEF VALVES ON DISCHARGE SIDE OF FIRE PUMP'S OR PROVE THAT ADDITIONAL FIRE PUMP PRESSURE IS NEEDED TO PROVIDE 50 PSI AT THE HIGHEST HOSE STATION.
Construction/Loadline
Issued 5 March 1986
Resolved
FREE DOGS ON WATERTIGHT DOOR TO MUD PIT ROOM.
Construction/Loadline
Issued 5 March 1986
Resolved
REPAIR UNALIGNED DOGS (OR REPLACE MISSING DOGS) ON HATCH COVER TO THE COMPRESSOR ROOM HATCH LOCATED ON THE MAIN DECK.
Construction/Loadline
Issued 5 March 1986
Resolved
REPLACE FRACTURED DOGS FITTED ON THE WATERTIGHT DOOR LOCATED ON THE AFT SIDE OF THE HOUSE, NEAR THE BOW LEG. (THIS W/T DOOR IS TO A FOUR (4) MAN SLEEPING COMPARTMENT).
Lifesaving
Issued 5 March 1986
Resolved
CLEAN ELECTRICAL CONTACTS IN THE WINCH CONTROL BOXES TO BOTH LIFE BOATS.
Accommodation/Occupational Safety
Issued 5 March 1986
Resolved
PROVIDE DEADMAN NOZZLE FOR THE DRESSER ATLAS LOGGING UNIT REFUELING HOSE.
Construction/Loadline
Issued 5 March 1986
Resolved
REPLACE BROKEN DOGS ON DECK HATCH TO SACK ROOM.
Lifesaving
Issued 5 March 1986
Resolved
PROVIDE ONE ADDITIONAL SERVICE LINE AND ONE ADDITIONAL SERVICE PROJECTILE FOR THE LINE THROWING GUN.
Fire Fighting
Issued 5 March 1986
Resolved
REPAIR GENERAL ALARM BELLS IN THE ENGINE ROOM AND DRILL FLOOR.
Engineering
Issued 5 March 1986
Resolved
PROVIDE A REMOTE FUEL SHUTOFF FOR THE EMERGENCY GENERATOR LOCATED OUTSIDE THE EMERGENCY GENERATOR ROOM.
Construction/Loadline
Issued 5 March 1986
Resolved
REPAIR NUTS AND BOLTS TO DECK MANHOLE COVER TO THE 22A TANK. MOST OF THE BOLTS AND NUTS ARE MISSING.
Construction/Loadline
Issued 5 March 1986
Resolved
REPAIR PACKING GLANDS AT DECK LEVEL TO THE DUMP VALVES AS FOLLOWS: PL#28,162,8.
Accommodation/Occupational Safety
Issued 5 March 1986
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION THE THREE HOT WATER HEATERS OR INSTALL RELIEF VALVES RATED AT 100 PSI OR LESS/AND TEMPERATURE LESS THAN 200 F 46 CFR 54.01-15.
Electrical
Issued 5 March 1986
Resolved
PROVE SATISFACTORY OPERATION OF THE LOW LUBE OIL ALARM ON THE #3 EMD.
Electrical
Issued 5 March 1986
Resolved
PROVE SATISFACTORY OPERATION OF THE OVERSPEED ALARM ON THE #1 EMD.
Deck/Cargo
Issued 5 March 1986
Resolved
PROVIDE A FLAME SCREEN ON GOOSE NECK ON FUEL TANK TO EMERGENCY GENERATOR.
Lifesaving
Issued 5 March 1986
Resolved
REPAIR OUTBOARD LIFE LINE ON LIFEBOAT NO.2.
Deck/Cargo
Issued 5 March 1986
Resolved
HYDROSTATICALLY TEST OR REPLACE FUEL HOSE LOCATED ON THE RIG'S PORT SIDE; 33CFR155.
Documentation
Issued 5 March 1986
Resolved
PROVIDE ONBOARD THE REQUIRED NUMBER OF LIFEBOAT MAN PER THE VESSEL'S COI. COMPLIANCE DATE IS 12MAR86.
Lifesaving
Issued 5 March 1986
Resolved
PROVIDE SMOKE FOR ONE RING LIFE BUOY.
Electrical
Issued 5 March 1986
Resolved
REPLACE BROKEN GLASS TUBES ON OVERHEAD FLAMESCENT LIGHTS IN RADIATOR AREA ON MAIN DECK AFT.
Lifesaving
Issued 5 March 1986
Resolved
PROVIDE AN ADDITIONAL 20 TRIANGULAR BANDAGES FOR THE RIG'S FIRST AID KIT.
Lifesaving
Issued 5 March 1986
Resolved
MAKE OPERATIONAL THE CABLE RELEASE MECHANISM AT BOTH LIFE RAFT STATIONS.
Fire Fighting
Issued 5 March 1986
Resolved
SERVICE DRY CHEM. FIRE EXT. AT STATION #38 OR REPLACE.
Construction/Loadline
Issued 5 March 1986
Resolved
REPAIR/ADJUST HATCH ON EXPANSION TRUNK ON PRELOAD TANK 29. THE HATCH CAN NOT BE DOGGED DOWN FOR WATERTIGHT INTEGRITY.
Fire Fighting
Issued 5 March 1986
Resolved
REPAIR INOPERABLE GENERAL ALARM BELL LOCATED ON THE AFT BULKHEAD OF THE QUARTERS (I.E. SIDE NEAR HELO-DECK).
Deck/Cargo
Issued 13 February 1985
Resolved
TEST AND MARK THE FUEL OIL HOSES AS PER 33 CFR 155.800.
Deck/Cargo
Issued 13 February 1985
Resolved
PROVIDE A FUELING CAN FOR THE FORK TRUCK AS PER 46 CFR 109.537.
Lifesaving
Issued 13 February 1985
Resolved
REPAIR THE LIFELINE ON THE STARBOARD BOAT. 46 CFR 108.
Navigation
Issued 13 February 1985
Resolved
PROVIDE A MANUAL CONTROL FOR THE WHISTLE / FOG HORN. RULE 33(A) INTERNATIONAL REGULATIONS FOR PREVENTING COLLISIONS AT SEA.
Engineering
Issued 13 February 1985
Resolved
PROVIDE RELIEF VALVES FOR THE #2 AND #3 AIR RECIEVERS. 46 CFR 54.15.
Engineering
Issued 13 February 1985
Resolved
PROVIDE RELIEF VALVES FOR THE #3 AND #4 BULK TANKS. 46 CFR 54.15.
Electrical
Issued 13 February 1985
Resolved
CONDUCT AND LOG THE TEST OF THE EMERGENCY GENERATOR, AS PER 46 CFR 109.211.
Lifesaving
Issued 13 February 1985
Resolved
PROVIDE TWELVE HAND HELD RED FLARES FOR THE STARBOARD BOAT. 46 CFR 108.501.
Fire Fighting
Issued 13 February 1985
Resolved
MAKE SERVICEABLE THE FIRE NOZZLES AND FOG APPLICATORS IN THE MACHINERY SPACES. 46 CFR 108.
Electrical
Issued 13 February 1985
Resolved
PLACE THE TELEPHONE TEST PANEL IN AN ENCLOSURE TO PREVENT A SHOCK HAZARD. 46 CFR 111.55.
Construction/Loadline
Issued 13 February 1985
Resolved
PROVIDE CONTAIMENT OF AT LEASE ONE-HALF BARREL AROUND THE FUEL OIL VENTS ASPER 33 CFR 155.320.
Navigation
Issued 13 February 1985
Resolved
INSTALL A STERN ANCHOR LIGHT, RULE 30 INTERNATIONAL REGULATIONS FOR PREVENTING COLLISIONS AT SEA.
Deck/Cargo
Issued 23 February 1984
Resolved
PROVIDE ONBOARD THE VESSEL AT THE STBD. AFT CRANE CONTROL BOX ,A LOAD CHART
Construction/Loadline
Issued 23 February 1984
Resolved
PROPERLY SEAL BULKHEAD PENETRATIONS IN MUD PIT ROOM, AIR COMPRESSER ROOM AND MECHANICS SHOP.
Electrical
Issued 23 February 1984
Resolved
PROPEERLY SECURE AFTER SHALE SHAKER ELECTRICAL SUPPLY J-BOX TO OVERHEAD.
Electrical
Issued 23 February 1984
Resolved
PROVIDE SEALED EYS FITTINGS FOR THE AFTER SHALE SHAKER MOTOR AND ASSOCIATEDJ-BOX ON OVERHEAD.
Electrical
Issued 23 February 1984
Resolved
PROVIDE LOSS OF VENTILATION ALARM IN A MANNED LOCATION FOR MUD PIT ROOM VENTILATION SYSTEM.
Construction/Loadline
Issued 23 February 1984
Resolved
PROVIDE GATE VALVES ON ALL SOUNDING TUBES BELOW THE FREEBOARD DECK.
Unknown
Issued 23 February 1984
Resolved
TOTAL PERSONSALLOWED ON BOARD THE VESSEL IS NOT TO EXCEED 64 PENDING IN- STALLATION OF DAVIT LAUNCHED LIFERAFTS PRESENTLY BEING SERVICED.
Fire Fighting
Issued 23 February 1984
Resolved
RENEW MISSING AIR PACK BOTTLES FOR FIREMANS OUTFITS.
Lifesaving
Issued 23 February 1984
Resolved
RENEW OUTDATED HAND HELD FLARES IN THE PORT LIFEBOAT.
Lifesaving
Issued 23 February 1984
Resolved
PROVIDE ON BOARD THE VESSEL IN THE STBD LIFEBOAT, 23 QTS. OF WATER TO RE- NEW OUTDATED WATER.
Electrical
Issued 23 February 1984
Resolved
REPAIR OR RENEW INOPERATIVE EMERGENCY LIGHTS AS NEEDED.
Electrical
Issued 11 August 1982
Resolved
TIE AIR CONDITIONER UNITS TO EMERGENCY VENTILATION SHUT DOWN FOR QUARTERS. 46 CFR 111.80-10
Lifesaving
Issued 11 August 1982
Resolved
PROVIDE EMERGENCY LIGHTING FOR BOTH LIFEBOAT STATIONS. NVC 4-78 3D(10)(2)
Fire Fighting
Issued 11 August 1982
Resolved
SERVICE FIRE FIGHTING EQUIPMENT AS REQUIRED BY 46 CFR 107.235 AND 46 CFR 109.223.
Unknown
Issued 7 February 1982
Resolved
MAKE FOUR P-TANKS AVAILABLE FOR INTERNAL INSPECTION.
Lifesaving
Issued 7 February 1982
Resolved
WEIGHT TEST INFLATABLE LIFERAFT DAVITS.
Unknown
Issued 7 February 1982
Resolved
MAKE DRILL FLOOR AIR RECIEVER AVAIABLE FOR 1 1/2 MAWP HYDROSTATIC TEST.
Electrical
Issued 7 February 1982
Resolved
AIR PURGE ROOM AT STBD AFT SIDE OF DRILL FLOOR. (WITH PROPER DOOR CLOSEUP AND VENTILATION ALARM).
Lifesaving
Issued 7 February 1982
Resolved
PROVIDE CUP 20 MAN LIFERAFT.
Casualty record · 1
8 October 2004Routine · role: Involved in a Marine Casualty · 1 injured · activity 2225042
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.