Records from 1981 to 1995. Most recent: inspection, 27 October 1995.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
27 October 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 115275
6 May 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021594
20 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017839
5 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010046
4 March 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316648
15 August 1986
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1010764
15 August 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018310
28 May 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 995036
23 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983867
12 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980457
12 March 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322815
25 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977698
9 September 1984
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325962
11 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964494
18 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272158
9 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276139
15 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970346
4 March 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279013
11 March 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968915
Accommodation/Occupational Safety
Issued 28 May 1986
Resolved
PROVIDE RELIEF VALVES FOR THE HOT WATER HEATERS SET AT NOT MORE THAN 100 PSI, PER ANSI Z21,22.
Condition: Unknown
Due 1 April 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 28 May 1986
Resolved
PROVIDE A RELIEF VALVE FOR THE RIG AIR RECEIVER SET AT NOT MORE THAN THE VESSEL MAWP (150 PSI).
Condition: Unknown
Due 31 December 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 28 May 1986
Resolved
REPLACE MISSING AC GENERATOR PRIME MOVER PRIOR TO COMMENCING A DRILLING OP-ERATION. PRIME MOVER ARMS AND BOTH REVERSE POWER RELAYS TO BE TESTED IN PRESENCE OF A MARINE INSPECTOR.
Condition: Unknown
Due 1 April 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 28 May 1986
Resolved
SERVICE AND RE-SEAL ALL FIRE EXTINGUISHERS REQUIRING SEALS, AND HYDRO TEST AS REQUIRED.
Condition: Unknown
Due 1 April 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Documentation
Issued 28 May 1986
Resolved
CONDUCT AND LOG ALL APPLICABLE ACTIVITIES PER 46CFR109,433.
Condition: Unknown
Due 1 April 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 28 May 1986
Resolved
HYDRO TEST AND RECHARGE SCBA BOTTLES AS REQUIRED.
Condition: Unknown
Due 1 April 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 28 May 1986
Resolved
PROVIDE ONE OPERABLE APPROVED (UL OR FM) OXYGEN-EXPLOSIVE GAS METER, OR PROVIDE APPROVAL DATA FOR THE GAS-TECH METER.
Condition: Unknown
Due 1 April 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Accommodation/Occupational Safety
Issued 28 May 1986
Resolved
REPAIR CONTROL AIR LEAK AT DRILLERS CONSOLE.
Condition: Unknown
Due 1 April 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 28 May 1986
Resolved
REPAINT GENERAL ALARM WARNING AT FIRE STATION 30.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Electrical
Issued 28 May 1986
Resolved
REPLACE CRACKED LENS, LIGHT FIXTURE IN MUD PIT ROOM.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Navigation
Issued 28 May 1986
Resolved
REPLACE THE NAVIGATIONAL LIGHT FIXTURES - STERN LIGHT, LOWER RED MAST HEAD LIGHT - DUE TO DETERIORATION.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Accommodation/Occupational Safety
Issued 28 May 1986
Resolved
REPLACE MISSING HAND WHEEL TO SERVICE AIR RECEIVER.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Electrical
Issued 28 May 1986
Resolved
MAKE OPERABLE THE VENTILATION SHUTDOWN FOR THE GENERATOR ROOM.
Condition: Unknown
Due 1 April 1987
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 28 May 1986
Resolved
REPAIR LEAKS AT THE ENGINE FUEL OIL FILTERS.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Construction/Loadline
Issued 28 May 1986
Resolved
LABEL ALL MANUAL VALVES IN THE (3) PUMP ROOMS, AND IN THE FIRE MAIN SYSTEM.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Construction/Loadline
Issued 28 May 1986
Resolved
REPACK THE OVERBOARD DISCHARGE VALVE IN THE STBD. PUMP ROOM AND ALL LEAKINGBALLAST CONTROL VALVES.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Construction/Loadline
Issued 28 May 1986
Resolved
REPACK HYDRAULIC CONTROL VALVES A-7,5,16,10,14,11 & 12 AND REPAIR HYDRAULICLEAK AT OPEN SIDE OF VALVE A14, & 16.
Condition: Unknown
Due 28 May 1986
Resolved 28 May 1986
Electrical
Issued 28 May 1986
Resolved
PROVIDE PROPER INSTALLATION OF THE TELEPHONE JUNCTION BOX LOCATED ON THE DRILL FLOOR, A CLASS I DIVISION II AREA.
Condition: Unknown
Due 31 December 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 9 March 1983
Resolved
ADJUST GENERAL ALARM BELL IN ACTIVE MUD PIT FOR PROPER OPERATION OR REPLACEWITH AN OPERABLE EXPLOSION PROOF UNIT.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Documentation
Issued 9 March 1983
Resolved
PROVIDE CRANE LOAD CAPACITY TABLE FOR LINK BELT 238 IN CRANE RECORD BOOK.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Electrical
Issued 9 March 1983
Resolved
REPAIR REVERSE POWER RELAYS ON SWITCHBOARD AND MAKE AVAILABLE FOR TEST.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Electrical
Issued 9 March 1983
Resolved
PROVIDE EYS SEAL ON TOP OF SWITCH FOR BRANDT SHAKER UNIT.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Construction/Loadline
Issued 9 March 1983
Resolved
INSTALL A GAS TIGHT SELF-CLOSING DOOR BETWEEN INACTIVE MUD PIT AND DOWELL ROOM.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Construction/Loadline
Issued 9 March 1983
Resolved
PROVIDE DOOR CLOSURE FOR DOOR BETWEEN ACTIVE MUD PITS AND MUD PUMP ROOM.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Electrical
Issued 9 March 1983
Resolved
FILL EYS SEALS ON CATHODIC PROTECTION SYSTEM JUNCTION BOX UNDER ACTIVE MUD PIT.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Electrical
Issued 9 March 1983
Resolved
INSTALL SUITABLE BUNK LIGHTS IN STATEROOM NO. 10
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Construction/Loadline
Issued 9 March 1983
Resolved
REPAIR OR REPLACE INDICATOR SWITCH ON VALVE 6A, AFT PUMP ROOM.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Construction/Loadline
Issued 9 March 1983
Resolved
PROVIDE LABEL FOR VALVE 8A, AFT PUMP ROOM
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Electrical
Issued 9 March 1983
Resolved
REPAIR OR REPLACE JUNCTION BOX ON AFTER PORTABLE WATER PUMP IN AFTER PUMP ROOM.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Unknown
Issued 9 March 1983
Resolved
THE FOLLOWING DEFICIECIES PERTAIN TO THE VESSEL TRANSWORLD 54, CG000101.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Deck/Cargo
Issued 9 March 1983
Resolved
LABEL CONTROLS AND STENCIL LIFTING CAPACITY ON FORKLIFT.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Construction/Loadline
Issued 9 March 1983
Resolved
REPAIR OR REPLACE INDICATOR SWITCH BAR ON CONTROL VALVE 12A, AFT PUMP ROOM.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Construction/Loadline
Issued 9 March 1983
Resolved
REPAIR OR REPLACE INDICATOR SWITCH ON VALVE P8, PORT PUMP ROOM.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Construction/Loadline
Issued 9 March 1983
Resolved
REPAIR OR REPLACE INDICATOR LIGHTS FOR VALVES 61, 8P, 7P AND 12P.
Condition: Unknown
Due 9 March 1983
Resolved 9 March 1983
Accommodation/Occupational Safety
Issued 15 June 1982
Resolved
REVERSE AIR FLOW IN MUD PUMP ROOM TO PROVIDE POSITIVE VENTILATION TO KEEP GASES FROM PITS ENTERING PUMP ROOM. NVC 4-78 3D(1)(A)
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Electrical
Issued 15 June 1982
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Lifesaving
Issued 15 June 1982
Resolved
PROVIDE PAINTER 3X DISTANCE FROM WATER AT LIGHTED DRAFT TO DECK WHERE LIFEFLOAT IS STOWED. PAINTER SHOULD BE AT LEAST 1/2 DIAMETER ROPE.
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Lifesaving
Issued 15 June 1982
Resolved
PROVIDE OPERABLE WATERLIGHTS FOR AT LEAST THIRTEEN (13) LIFE PRESERVERS. (46 CFR 108.514)
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Fire Fighting
Issued 15 June 1982
Resolved
CONDUCT A SATISFACTORY FIRE DRILL. 46 CFR 109.213
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Electrical
Issued 15 June 1982
Resolved
PROVIDE ADDITIONAL GENERAL ALARM BELLS ON MAIN DECK AND IN MACHINERY SPACESFOR PROPER AUDIBILITY. NVC 4-78 3D(1)(A)
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Electrical
Issued 15 June 1982
Resolved
INSTALL EXPLOSION PROOF GENERAL ALARM BELL IN MUD PITS NVC 4-78 3 D (10) (B)
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Electrical
Issued 15 June 1982
Resolved
INSTALL BREAKERS OR SPACERS, SECURE COVER ON 600V PANEL BEHIND TRANSFORMER NVC 4-78 3 D (N) A.
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Navigation
Issued 15 June 1982
Resolved
REPAIR OPEN JUNCTION BOX AND SPLICED WIRING TO PHONE HORN IN ENGINE ROOM.
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Electrical
Issued 15 June 1982
Resolved
PROPERLY MOUNT JUNCTION BOX OVER PUMP ROOM WINDOW IN MUD PIT NVC 4-78 3 D (10) (B).
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Fire Fighting
Issued 15 June 1982
Resolved
WEIGH ALL FIXED AND PORTABLE CO2 EXTINGUISHERS. TEST TIME DELAY AND ASSOCIATED EQUIPMENT OF FIXED SYSTEM. (NVC 6-72)
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Electrical
Issued 15 June 1982
Resolved
REPAIR VISUAL ALARM FOR GENERAL ALARM SYSTEM IN GENERATOR ROOM. (NVC 4-78 3D(1)(A))
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Fire Fighting
Issued 15 June 1982
Resolved
PROVIDE ONE (1) 3-CELL FLASHLIGHT SPARE BATTERIES AND TWO (2) O2 AND EXPLOSIVE METERS FOR FIREMANS OUTFITS 46 CFR 108.497
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Navigation
Issued 15 June 1982
Resolved
PROVIDE RED LENS FOR LOWEST MAST LIGHT (NVC/SPECIAL OCCUPATIONS MAST) 72 COLREGS.
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Documentation
Issued 15 June 1982
Resolved
SUBMIT FOR APPROVAL THE FIRE CONTROL PLAN. SHOULD BE SUBMITTED AFTER MODIFICATIONS ARE COMPLETED AT DRYDOCKING NVC 4-78 3 D (2).
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Lifesaving
Issued 15 June 1982
Resolved
PROVIDE ONE (1) AUXILLARY LINE AT LEAST 1/2 X 500FT AND FIVE (5) CARTRIDGES46 CFR 94.45-15(B)(6)II.
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Fire Fighting
Issued 15 June 1982
Resolved
SERVICE, INCLUDING HYDROSTATIC TESTING AS NECESSARY, ALL FIXED SEMI- PORTABLE AND PORTABLE FIRE EXTINGUISHERS (46 CFR 109.233)
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982
Deck/Cargo
Issued 15 June 1982
Resolved
PROVIDE FLAME SCREENS ON FUEL TANK SOUNDING/VENT PIPES NVC 4-783 D (1) (A)
Condition: Unknown
Due 15 June 1982
Resolved 15 June 1982