Records from 1981 to 1989. Most recent: inspection, 22 August 1989.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
22 August 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1315112
6 February 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013246
16 December 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1026095
17 June 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306087
27 May 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304148
19 March 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987069
19 December 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993493
22 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977855
14 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987629
9 May 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973987
24 April 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973587
4 April 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973583
27 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973577
16 August 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1274379
2 May 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967200
8 March 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278080
28 October 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1277000
21 September 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968743
30 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969642
21 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1272589
18 November 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1273272
9 March 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277399
Construction/Loadline
Issued 27 May 1986
Resolved
FREE UP FROZEN DOGS AND SECURE ALL WATERTIGHT DOORS AND HATCHES THROUGHOUT VESSEL(AVOVE AND BELOW DECK).
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Construction/Loadline
Issued 27 May 1986
Resolved
MAKE WATERTIGHT THE THROUGH THE MAIN DECK PENETRATION OF THE ELECTRICAL CABLE THAT RUN INTO THE ENGINE FROOM SWITCHBOARD.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Accommodation/Occupational Safety
Issued 27 May 1986
Resolved
REPAIR WASTED FUEL OIL VENT PIPE, PORT SIDE, MAIN DECK. PIPE IS WASTED THROUGH AT DECK LEVEL.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Construction/Loadline
Issued 27 May 1986
Resolved
REPAIR PACKING GLAND ON REACH ROD WHERE IT PENETRATES THE MAIN DECK, LOCATED ON STBD SIDE REAR STBD LEG (IE. UNDERNEATH LADDER LEADING UP TO SHAKEN AREA.
Condition: Unknown
Due 27 May 1986
Resolved 27 May 1986
Unknown
Issued 4 April 1984
Resolved
ALTER GENERAL ALARM SYSTEM TO COMPLY WITH 46 CFR 113.05.
Condition: Unknown
Due 4 May 1984
Resolved 4 April 1984
Unknown
Issued 4 April 1984
Resolved
INSTALL QUARTERS VENTILATION SHUT DOWN CONTROLLER.
Condition: Unknown
Due 4 May 1984
Resolved 4 April 1984
Unknown
Issued 4 April 1984
Resolved
INSTALL RELIEF VALVES ON FIRE PUMP DISCHARGE LINES.
Condition: Unknown
Due 4 May 1984
Resolved 4 April 1984
Unknown
Issued 4 April 1984
Resolved
RELOCATE AIR INTAKE FOR DRAWWORKS MOTORS OUTSIDE OF CLASSIFIED LOCATIONS.
Condition: Unknown
Due 4 May 1984
Resolved 4 April 1984
Electrical
Issued 4 April 1984
Resolved
TEST THE OVERSPEED TRIP ON #1 AC GENERATOR.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Electrical
Issued 4 April 1984
Resolved
RESUPPORT WIRING AT FOLLOWING LOCATIONS: MUD PUMP RM; RIG FLOOR; WIRING TO RADIO & NAV LIGHTS COMING INTO OFFICE, GALLEY & REC RM; EMER GEN ROOM.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Unknown
Issued 4 April 1984
Resolved
REPLACE OR REPAIR BUNK AND OVERHEAD LIGHTS IN QUARTERS AS NEEDED.
Condition: Unknown
Due 4 May 1984
Resolved 4 April 1984
Unknown
Issued 4 April 1984
Resolved
REPLACE THROW OVER TYPE 20 MAN INFLATABLE LIFERAFT WITH A DAVIT LAUNCHED TYPE OR SHOW EVIDENCE OF A PREVIOUS AUTHORIZED EXMPTION OR REDUCE MANNING.
Condition: Unknown
Due 4 May 1984
Resolved 4 April 1984
Unknown
Issued 4 April 1984
Resolved
CONDUCT FIRE AND ABANDON RIG DRILLS WHEN MODU IS CREWED AND PLACED BACK IN SERVICE.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Unknown
Issued 4 April 1984
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE PENROD 54, DN502157.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Electrical
Issued 4 April 1984
Resolved
REPAIR DEFECTIVE EMERGENCY LIGHT TO PORT LIFERAFTS.
Condition: Unknown
Due 4 April 1984
Resolved 4 April 1984
Accommodation/Occupational Safety
Issued 30 June 1982
Resolved
REPAIR VENT SHUTDOWN SWITCH FOR MACHINERY SPACES AND LABEL SAME.
Condition: Unknown
Due 30 June 1982
Resolved 30 June 1982
Electrical
Issued 30 June 1982
Resolved
REPAIR BERTH LIGHTS IN BUNK ROOMS 5 AND 13.
Condition: Unknown
Due 30 June 1982
Resolved 30 June 1982
Lifesaving
Issued 30 June 1982
Resolved
PROVIDE ONE ADDITIONAL HANDHELD FLARE FOR RIG.
Condition: Unknown
Due 30 June 1982
Resolved 30 June 1982
Fire Fighting
Issued 30 June 1982
Resolved
REPAIR OR REPLACE OXYGEN/GAS METER FOR FIREMAN'S OUTFIT IN CONTROL ROOM.
Condition: Unknown
Due 30 June 1982
Resolved 30 June 1982
Lifesaving
Issued 30 June 1982
Resolved
PROVIDE PRIMARY LIFESAVING EQUIPMENT FOR 12 ADDITIONAL PERSONS. UNTIL PRO-VIDED, VESSEL MAY NOT CARRY MORE THAN 50 PERSONS.
Condition: Unknown
Due 30 June 1982
Resolved 30 June 1982
Lifesaving
Issued 30 June 1982
Resolved
PROVIDE TWO ADDITIONAL PROJECTILES AND ONE (1) 500 FEET AUXILIARY LINE FOR LINE-THROWING APPLIANCE.
Condition: Unknown
Due 30 June 1982
Resolved 30 June 1982
Lifesaving
Issued 30 June 1982
Resolved
REPLACE LIFE RINGS AT STARBOARD AFT CORNER AND AT #1 LIFERAFT STATION WITH APPROVED DEVICES.
Condition: Unknown
Due 30 June 1982
Resolved 30 June 1982
Deck/Cargo
Issued 30 June 1982
Resolved
PROVIDE WARNING DEVICE FOR FORKLIFT.
Condition: Unknown
Due 30 June 1982
Resolved 30 June 1982
Electrical
Issued 30 June 1982
Resolved
MAKE PROPER ELECTRICAL CONNECTIONS FOR DC MUD PUMP MOTORS.
Condition: Unknown
Due 30 June 1982
Resolved 30 June 1982
Electrical
Issued 30 June 1982
Resolved
REMOVE SPLICE IN YELLOW CORD NEAR PUMP CONTROLLER IN MUD PIT ROOM.
Condition: Unknown
Due 30 June 1982
Resolved 30 June 1982
Accommodation/Occupational Safety
Issued 30 June 1982
Resolved
PROVIDE LOSS OF VENT ALARM FOR MUD PIT SUPPLY FAN.
Condition: Unknown
Due 30 June 1982
Resolved 30 June 1982
Documentation
Issued 30 June 1982
Resolved
PROVIDE ON BOARD CG-APPROVED OPERATING MANUAL/CONSTRUCTION PORTFOLIO/STAR- BOARD LETTER.
Condition: Unknown
Due 30 June 1982
Resolved 30 June 1982
Construction/Loadline
Issued 18 November 1981
Resolved
ENCLOSE ONE END OF THE OPEN STAIRWELL IN THE LIVING QUARTERS BETWEEN THE MAIN DECK AND THE 01 LEVEL. SEE NVIC 4-78 (3.D.7.A).
Condition: Unknown
Due 18 November 1981
Resolved 18 November 1981