Records from 1981 to 2008. Most recent: inspection, 26 June 2008.
Inspection history · 115
26 June 2008
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3282979
14 November 2007
Hull Examination
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3098675
15 October 2007
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3080294
26 September 2007
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3066473
26 June 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2974508
17 June 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2965746
4 May 2007
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2922161
10 April 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2905815
2 September 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2778142
2 May 2006
COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2643641
28 October 2005
Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2546011
2 May 2005
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2347542
4 February 2005
COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2286879
23 September 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2203320
2 September 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2184574
26 May 2004
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2049447
21 April 2004
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2049587
3 November 2003
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1941065
22 August 2003
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1900683
9 May 2003
Administrative Inspection · Hull Examination · Deficiency Check · Periodic Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1736331
10 June 2002
Re-Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1627869
26 September 2001
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1074853
1 May 2001
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1063644
19 April 2001
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1471248
12 March 2001
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1061395
2 February 2001
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1454952
3 August 2000
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1053068
11 May 2000
Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 818077
28 April 2000
COI Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1410300
30 July 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1109138
26 March 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 778825
10 March 1999
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 803557
6 October 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 801161
28 July 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1129954
7 July 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 794010
6 July 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1128645
5 June 1998
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1381286
20 May 1998
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1438733
10 February 1998
Hull Examination · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1392801
12 November 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1122476
19 September 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1113337
30 July 1997
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1430446
23 July 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1116192
21 May 1997
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1392692
17 April 1997
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1097716
19 August 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469138
25 July 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1087566
16 April 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1081117
18 December 1995
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 882426
25 October 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1079197
25 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1184733
31 July 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367461
8 June 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1186027
10 March 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 868531
7 February 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403892
28 October 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1181843
25 October 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 864173
18 September 1994
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411034
31 August 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363090
9 February 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1165475
21 January 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 852119
18 October 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 647782
9 October 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 140054
5 August 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1414189
4 August 1992
Re-Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1426750
13 July 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 7
13 July 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 31158
24 June 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417459
10 January 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1268635
4 December 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 942864
30 October 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1256864
30 August 1991
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1441954
14 August 1991
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1250853
14 June 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 936653
9 May 1991
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240847
26 October 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918532
17 October 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 921885
15 August 1990
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 910893
18 June 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1229269
26 December 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 910469
1 November 1989
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1286770
26 October 1989
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1210676
21 August 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890216
23 May 1989
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1205931
17 May 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1037612
28 September 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 890034
12 November 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1022150
16 September 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1010062
1 September 1987
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1002024
28 May 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1026459
3 February 1987
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1311558
12 September 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1312557
25 August 1986
Examination of Repairs · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 984731
2 July 1986
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1296355
24 April 1986
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1302178
8 April 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309254
28 February 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1304764
26 February 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987997
7 November 1985
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993537
8 October 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1301031
6 March 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 979603
6 March 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299323
31 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1286443
3 May 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 973080
7 December 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971813
10 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971203
16 September 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964091
4 August 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1271143
27 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273202
25 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275047
5 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968526
16 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1279699
16 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276149
9 August 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966238
6 March 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1273000
Engineering › Pressure Vessel › Shell Plate
Issued 28 March 2005
Resolved
Complete Internal Inspection of All pressure vessels listed on Certificate of Inspection at next rig move while conducting SEILOD phase II inspection.
Due 15 May 2005
Resolved 2 June 2005
Lifesaving › Inflatable Liferafts › Servicing
Issued 28 March 2005
Resolved
Prove renewal of falls for both life raft davit falls IAW 46 CFR 109.301(j).
Due 28 April 2005
Resolved 2 May 2005
Construction/Loadline › Hull › Bottom Plating
Issued 15 March 2005
Resolved
Complete SEILOD phase II during next rig move.
Due 15 September 2005
Resolved 28 October 2005
Documentation › Manuals/Policy Documentation
Issued 16 May 2003
Resolved
Submit for final review and approval Revision 8 of MODU Operations Manual to MSSO Brownsville, Texas.
Due 20 April 2004
Resolved 20 April 2004
Documentation › Certificates/Documents
Issued 16 May 2003
Resolved
Submit for final review MODU Fire Control and Safety Plan to MSSO Brownsville, Texas.
Due 16 July 2003
Resolved 20 April 2004
Engineering › Generator (propulsion-electric)
Issued 10 June 2002
Resolved
Provide heat shields for all three generator exhaust bellows assemblies.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 2 July 2002
Resolution: Received email confirmation (with photos) that exhaust bellows assemblies had been installed.
Engineering › Diesel Engine (propulsion-electric)
Issued 10 June 2002
Resolved
Tighten blower cover assemblies on #1 & #3 Ship's Service generators. LEGACY COMPONENT DESC: Blower, Centrifugal
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 July 2002
Resolved 27 June 2002
Resolution: Received fax confirmation that blower cover assemblies had been tightened. 02JUL02 - received digital photos confirming resolution.
Construction/Loadline
Issued 19 April 2001
Resolved
Renew wasted pipe support stanchion for bilge piping located in bilge pump room.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 19 April 2001
Resolved
Crop and renew wasted bulkhead stiffner located in bilge pump room.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Electrical
Issued 19 April 2001
Resolved
Provide directory list for all missing electrical panels.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Accommodation/Occupational Safety
Issued 19 April 2001
Resolved
Provide storm welds on temporary quarters located on top of permanent quarters.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Unknown
Issued 19 April 2001
Resolved
Provide cover with fusable plug for part cleaner tank located in motor_x001C_ room.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Electrical
Issued 19 April 2001
Resolved
Properly secure all electrical access panels.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 19 April 2001
Resolved
Provide line diagram for bilge suction piping and label accordingly.
Condition: Unknown
Due 19 April 2001
Resolved 19 April 2001
Construction/Loadline
Issued 28 April 2000
Resolved
Make reach packing boxes water tight, main deck.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Electrical
Issued 28 April 2000
Resolved
Install E-light bulk cement room.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Lifesaving
Issued 28 April 2000
Resolved
Replace cap on eye wash station at mud pit room.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Construction/Loadline
Issued 28 April 2000
Resolved
Install closure at port bulkhead mud pit room.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Construction/Loadline
Issued 28 April 2000
Resolved
Renew studs various manway covers.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Electrical
Issued 28 April 2000
Resolved
Make repairs to low lube oil alarm on Nr. 2 generator.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Fire Fighting
Issued 28 April 2000
Resolved
Have SCBA bottles hydrostatically tested as required.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Electrical
Issued 28 April 2000
Resolved
Cover Empty spaces in light switch plates.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Documentation
Issued 28 April 2000
Resolved
Provide copy of SOPEP approval letter.
Condition: Unknown
Due 16 May 2000
Resolved 16 May 2000
Accommodation/Occupational Safety
Issued 28 April 2000
Resolved
Ensure proper closure of all interior doors.
Condition: Unknown
Due 26 May 2000
Resolved 26 May 2000
Electrical
Issued 28 April 2000
Resolved
Prove proper operation of number 4 generator after replacing mag pick-up.
Condition: Unknown
Due 15 May 2000
Resolved 15 May 2000
Fire Fighting
Issued 20 May 1998
Resolved
Attach hose rack to bulkhead on Fire Station N0 2.
Condition: Unknown
Due 20 May 1998
Resolved 22 May 1998
Lifesaving
Issued 20 May 1998
Resolved
Repair exhaust leak in piping in lifeboat N0 4.
Condition: Unknown
Due 21 May 1998
Resolved 22 May 1998
Lifesaving
Issued 20 May 1998
Resolved
Adjust all limit switches on all lifeboats.
Condition: Unknown
Due 20 May 1998
Resolved 22 May 1998
Lifesaving
Issued 20 May 1998
Resolved
Conduct release test under load on all lifeboats as per 46CFR109.301 (i)(5).
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Unknown
Issued 20 May 1998
Resolved
Provide ABS reports for repairs and Leg repair project.
Condition: Unknown
Due 20 May 1998
Resolved 20 May 1998
Electrical
Issued 20 May 1998
Resolved
Remove dead end wires in cook's bathroom and linen locker.
Condition: Unknown
Due 20 May 1998
Resolved 22 May 1998
Engineering
Issued 30 July 1997
Resolved
PROVIDE DOCUMENTATION OF PRESSURE TEST FOR FUEL TRANSFER HOSES
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Construction/Loadline
Issued 30 July 1997
Resolved
REPAIR BULKHEAD BETWEEN MUD PIT AND MUD PUMP ROOMS.
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Documentation
Issued 30 July 1997
Resolved
PROVIDE PROPER OIL TRANSFER PROCEDURES
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997
Lifesaving
Issued 30 July 1997
Resolved
MAKE READY FOR WEIGHT TEST REGULAR SHIP'S LIFEBOAT AT STATION #3 TO BE WITNESSED BY CG MARINE INSPECTOR
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997
Electrical
Issued 30 July 1997
Resolved
PROVE PROPER OPERATION OF TOTAL RIG SHUTDOWN
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997
Accommodation/Occupational Safety
Issued 30 July 1997
Resolved
CROP AND RENEW WASTED POTABLE WATER PIPING
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Electrical
Issued 30 July 1997
Resolved
PROVE DEAD AT BOTH ENDS OR PLACE IN JUNCTION BOX, DEAD END WIRING IN COMPANY MAN'S ROOM, BEHIND DRYER AND TOOLPUSHERS OFFICE UNDER COMPUTER DESK
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Electrical
Issued 30 July 1997
Resolved
PROVIDE BUNK LIGHTS FOR TOP 2 RACKS IN ROOM #38
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Electrical
Issued 30 July 1997
Resolved
REPLACE INOPERABLE BATTERY LIGHT (E-LIGHT) IN WAY OF STARBOARD FORWARD LIFEBOAT ACCESS STAIRWAY
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Construction/Loadline
Issued 30 July 1997
Resolved
REPAIR WASTED HATCH COMBING KNIFE EDGES TO HATCH COVERS OVER RECREATION ANDTV ROOMS
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Construction/Loadline
Issued 30 July 1997
Resolved
PROVE PROPER OPERATION OF BILGE SYSTEM TO SACK ROOM AND P-TANK ROOMS
Condition: Unknown
Due 30 July 1997
Resolved 30 July 1997
Engineering
Issued 30 July 1997
Resolved
INSTALL FLAME SHIELDS ON ALL ENGINE FUEL FILTERS
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Fire Fighting
Issued 30 July 1997
Resolved
PROVIDE LEGIBLE INSTRUCTIONS FOR FIRE BOSS AND CO2 HOSE REEL SYSTEMS
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Fire Fighting
Issued 30 July 1997
Resolved
CROP AND RENEW FIRE MAIN IN ENGINE ROOM THAT HAS A TEMP REPAIR AND REPLACE WASTED FITTINGS ON FIRE MAIN AT THE PUMP
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Construction/Loadline
Issued 30 July 1997
Resolved
REPLACE WASTED KICKPIPE TO OUTLET FOR VENT SHUTDOWN TO PIT ROOM ON MAIN DECK
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Lifesaving
Issued 30 July 1997
Resolved
REPAIR OR REMOVE DAMAGED LADDER MAIN DECK, PORT SIDE IN WAY OF FUEL STATION.
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Fire Fighting
Issued 30 July 1997
Resolved
HYDROTEST AND SERVICE B-V FIRE EXTINGUISHER ON HELODECK
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Navigation
Issued 30 July 1997
Resolved
PROVE PROPER OPERATION IAW 33CFR67 OF FOGHORN
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Electrical
Issued 30 July 1997
Resolved
REPAIR "E" LIGHT IN MUD PIT ROOM.
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Construction/Loadline
Issued 30 July 1997
Resolved
GAUGE LOWER 20" OF BULKHEAD BETWEEN MUD PIT AND MUD PUMP ROOM AND PROVIDE COAST GUARD WITH COPY OF REPORT.
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Lifesaving
Issued 30 July 1997
Resolved
REPAIR EYEWASH STATIONS IN MUDPUMP ROOM AND SHAKER AREA.
Condition: Unknown
Due 30 August 1997
Resolved 15 September 1997
Construction/Loadline
Issued 21 May 1997
Resolved
REPAIR WASTED LANDING IN P-5B.
Condition: Unknown
Due 30 June 1997
Resolved 2 July 1997
Electrical
Issued 21 May 1997
Resolved
SECURE 2 EXPLOSION PROOF LIGHT FIXTURES in #8 void overhead.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 21 May 1997
Resolved
REPLACE GASKET TO GALLEY CREW HEAD VENT.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 21 May 1997
Resolved
REPAIR ALL SOUNDING TUBES AS NEEDED.
Condition: Unknown
Due 30 June 1997
Resolved 15 July 1997
Construction/Loadline
Issued 21 May 1997
Resolved
PROVIDE AN ABS SURVEY AND GUAGEING REPORT OF THE CONDITION OF ALL THREE LEGS PRIOR TO RIG MOVING.
Condition: Unknown
Due 30 June 1997
Resolved 28 July 1997
Construction/Loadline
Issued 21 May 1997
Resolved
FREE UP SWING CHECK ON DUMP VALVE IN P-7.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 21 May 1997
Resolved
CROP AND RENEW SIDE SHELL STIFFENERS IN P-2.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 May 1997
Resolved
AT COMPLETION OF PRESENT JOB AT VR309, THE OCEAN TOWER WILL PROCEED TO A REPAIR FACILITY FOR LEG REPAIRS AS PER ABS FAX DATED 30 MAY 97. THE OCEAN TOWER MUST PROCEED TO A REPAIR FACILITY PRIOR TO 30 SEP 97.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 May 1997
Resolved
PROVIDE GOAST GUARD WITH A COPY OF GUAGING REPORT BEING DONE AT THIS TIME.
Condition: Unknown
Due 30 June 1997
Resolved 28 July 1997
Construction/Loadline
Issued 21 May 1997
Resolved
RENEW LADDERS FROM TOP OF JACKHOUSE TO WATER ON AT LEAST 2 LEGS PRIOR TO 29MAY 97.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 21 May 1997
Resolved
MAKE ALL DRILL WATER TANKS READY FOR INSPECTION.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 May 1997
Resolved
CROP AND RENEW 4 WASTED BOTTOM STIFFENERS IN P-5.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 May 1997
Resolved
CONDUCT PHASE 2 OF SEILOD AND PROVIDE COAST GUARD WITH COPYS OF ABS AND DIVERS REPORTS.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 May 1997
Resolved
REPAIR ALL BROKEN REACH RODS AND REACH ROD PACKING GLANDS ON PRELOAD TANKS.
Condition: Unknown
Due 30 June 1997
Resolved 2 July 1997
Construction/Loadline
Issued 21 May 1997
Resolved
CROP AND RENEW WASTED HATCH COMBING FOR #8 VOID.
Condition: Unknown
Due 30 June 1997
Resolved 15 July 1997
Construction/Loadline
Issued 21 May 1997
Resolved
MAKE REPAIRS TO ALL TANKS AS REQUIRED BY ABS.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 May 1997
Resolved
REPLACE WASTED PLATFORM TO FWD STBD BB WINCH.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Electrical
Issued 21 May 1997
Resolved
PROVIDE MISSING PLUGS TO BOTH EXPLSION PROOF LIGHT FIXTURES IN VOID #5.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 21 May 1997
Resolved
REPAIR ALL WASTED HANDRAILS AND DECK GRATINGS.
Condition: Unknown
Due 30 June 1997
Resolved 15 July 1997
Construction/Loadline
Issued 21 May 1997
Resolved
CROP AND RENEW WASTED DRILL WATER SUCTION LINE IN #8 VOID.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 21 May 1997
Resolved
REPLACE WASTED LADDER TO PRELOAD TANK #4A ADJACENT TO RED FOX UNIT.
Condition: Unknown
Due 19 June 1997
Resolved 19 June 1997
Construction/Loadline
Issued 21 May 1997
Resolved
REPAIR WASTED FALSE BOTTOM IN P-4.
Condition: Unknown
Due 21 May 1997
Resolved 21 May 1997
Construction/Loadline
Issued 21 May 1997
Resolved
REPAIR WASTED LADDERS IN P-5B, P-4B, AND P-2.
Condition: Unknown
Due 30 June 1997
Resolved 2 July 1997
Lifesaving
Issued 19 August 1996
Resolved
CONDUCT PERMANENT REPAIRS TO LIFEBOAT #4._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Electrical
Issued 19 August 1996
Resolved
REPLACE CABLE RACEWAYS ON DRILL FLOOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Construction/Loadline
Issued 19 August 1996
Resolved
REPAIR WATERTIGHT DOORS AND VENT COVERS IN ACCORDANCE WITH ABS LOADLINE SURVEY REPORT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Documentation
Issued 19 August 1996
Resolved
PROVIDE APPROVED OPS MANUAL._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 22 August 1996
Resolved 22 August 1996
Documentation
Issued 19 August 1996
Resolved
PROVIDE ON BOARD APPROVED EMERGENCY EVACUATION PLAN.
Condition: Unknown
Due 22 August 1996
Resolved 22 August 1996
Accommodation/Occupational Safety
Issued 19 August 1996
Resolved
CROP AND RENEW PIPING ON MAIN FIRE MAIN, SEA SUCTION AND HOT WATER HEATER SYSTEM AT NEXT RIG MOVE. ALL REPAIRS TO BE HYDROSTATICALLY TESTED IN THE PRESENCE OF A MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 19 August 1996
Resolved 19 August 1996
Navigation
Issued 31 July 1995
Resolved
ENSURE ALL OBSTRUCTION LIGHTS FLASH IN UNISON.
Condition: Unknown
Due 15 August 1995
Resolved 17 August 1995
Deck/Cargo
Issued 31 July 1995
Resolved
PROVIDE TEST CERTIFICATES FOR POP-OFF VALVES BT-14 AND BT-10
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Electrical
Issued 31 July 1995
Resolved
PROVIDE STAINLESS STEEL BANDING FOR ELECTRICAL CABLES ON DERRICK AND ON OVERHEAD IN SHAKER HOUSE.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Electrical
Issued 31 July 1995
Resolved
ADJUST MUD PIT ROOM DOORS TO BE SELF CLOSING AND GAS TIGHT IAW 46 CFR 111.105
Condition: Unknown
Due 30 August 1995
Resolved 30 August 1995
Accommodation/Occupational Safety
Issued 31 July 1995
Resolved
PERFORM HYDROSTATIC TEST ON AIR RECEIVER BELOW DRILL FLOOR TO 1.25 TIMES THE MAWP PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Deck/Cargo
Issued 31 July 1995
Resolved
PROOF TEST PROPER OPERATION OF TOTAL RIG SHUTDOWN._x001C_
Condition: Unknown
Due 31 August 1995
Resolved 9 August 1995
Fire Fighting
Issued 31 July 1995
Resolved
PROPERLY INSTALL AND SECURE PNEUMATIC LINE TO HEAT ACTUATED DEVICE IN PAINTLOCKER CO2 SYSTEM.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Electrical
Issued 31 July 1995
Resolved
REPAIR BATTERY E-LIGHTS ON STARBOARD BLKD IN MOTOR ROOM.
Condition: Unknown
Due 7 August 1995
Resolved 9 August 1995
Construction/Loadline
Issued 31 July 1995
Resolved
PROPERLY SECURE BRAKE ACCESS TO STBD LEG
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Deck/Cargo
Issued 31 July 1995
Resolved
PROVIDE DOCUMENTATION ON FORKLIFT SHOWING "U.L." OR "F.M." TYPE "D" DESIGNATION.
Condition: Unknown
Due 15 August 1995
Resolved 17 August 1995
Fire Fighting
Issued 31 July 1995
Resolved
STENCIL "WHEN ALARM SOUNDS, GO TO YOUR STATION" AT EACH EMERGENCY ALARM ANUNCIATOR.
Condition: Unknown
Due 9 August 1995
Resolved 9 August 1995
Fire Fighting
Issued 31 July 1995
Resolved
PROVIDE AUTHORIZATION FOR GREATER THAN 50' LENGTHS OF FIRE HOSE AT FIRE STATIONS #51 AND #52 OR INSTALL ADDITIONAL FIRE HYDRANTS TO INSURE ALL LOCATIONS ON RIG CAN BE REACHED BY TWO EFFECTIVE STREAMS FROM SEPARATE _x001C_ HYDRANTS.
Condition: Unknown
Due 31 July 1995
Resolved 31 July 1995
Construction/Loadline
Issued 18 September 1994
Resolved
PROVIDE THIRD PARTY THICKNESS GAUGINGS OF SIDE SHELL PLATING IN #2 & 4 PRELOAD TANKS.
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Construction/Loadline
Issued 18 September 1994
Resolved
MAKE PERMANENT REPAIRS TO SIDE SHELL PLATING IN #2 PRELOAD TANK TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 18 September 1994
Resolved 18 September 1994
Construction/Loadline
Issued 18 September 1994
Resolved
PROVIDE REPAIR PROPOSAL FOR DAMAGE OF STARBOARD SPUD CAN AND COMPLETE MPI TESTING PRIOR TO RIG MOVE.
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Construction/Loadline
Issued 18 September 1994
Resolved
MAKE STARBOARD SPUD CAN AVAILABLE FOR INSPECTION AT EACH SIX (6) MONTH INTERVAL.
Condition: Unknown
Due 18 September 1994
Resolved 18 September 1994
Construction/Loadline
Issued 18 September 1994
Resolved
MAKE TEMPORARY REPAIRS TO HOLED SIDE SHELL PLATING IN #2 PRELOAD TANK PRIORTO FLOATING RIG.
Condition: Unknown
Due 7 October 1994
Resolved 7 October 1994
Construction/Loadline
Issued 31 August 1994
Resolved
REPAIR/ADJUST ALL WATERTIGHT DOORS AS NEEDED.
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Lifesaving
Issued 31 August 1994
Resolved
MAKE NECESSARY REPAIRS TO BOTH MUD PIT DOORS AS NEEDED TO COMPLY WITH 46CFR108.175(C).
Condition: Unknown
Due 31 August 1994
Resolved 31 August 1994
Accommodation/Occupational Safety
Issued 5 August 1993
Resolved
PROVIDE SHOP TEST REPORT OR HAVE COAST GUARD INSPECTOR WITNESS PROPER OPERATION OF RELIEF VALVES ON BOTH STARTING AIR AND RIG AIR RECIEVERS, TOTAL OF 4.
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Fire Fighting
Issued 5 August 1993
Resolved
REPLACE/TEST FLEX LOOPS ON FIRE BOSS FIRE FIGHTING SYSTEM IN ENGINE ROOM, ALSO REPLACE VALVE BETWEEN PRESSURE BOTTLE AND SPHERE BALL.
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Accommodation/Occupational Safety
Issued 5 August 1993
Resolved
CONDUCT INTERNAL EXAM OF #1 CEMENT AND ALL THREE (3) BARITE DRY BULK TANKS.
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Accommodation/Occupational Safety
Issued 5 August 1993
Resolved
MAKE READY FOR INTERNAL EXAM ALL AIR RECIEVERS(RIG AIR, STARTING AIR AND RIG FLOOR AIR).
Condition: Unknown
Due 5 August 1993
Resolved 5 August 1993
Construction/Loadline
Issued 24 June 1992
Resolved
COMPLETE SEILOD.
Condition: Unknown
Due 24 June 1992
Resolved 24 June 1992
Unknown
Issued 30 August 1991
Resolved
COMPLETE SPECIAL EXAMINATION IN LIEU OF DRYDOCK. SUBMIT PLAN REQUIRED BY 46CFR 107.267 TO COGNIZANT OCMI.
Condition: Unknown
Due 31 October 1992
Resolved 21 January 1992
Electrical
Issued 14 August 1991
Resolved
MAKE NECESSARY REPAIRS TO AND DEMONSTRATE OPERATION OF SCR REMOTE SHUTDOWN OPERATION FROM DRILL FLOOR.
Condition: Unknown
Due 3 January 1992
Resolved 3 January 1992
Unknown
Issued 15 August 1990
Resolved
HYDROSTATICALLY TEST THE SPHERICAL DRY CHEMICAL RESERVOIRS ON THE TWO FIRE BOSS 55# EXTINGUISHERS LOCATED AT FIRE STATIONS #58 AND #68.
Condition: Unknown
Due 15 August 1990
Resolved 15 August 1990
Construction/Loadline
Issued 1 November 1989
Resolved
PROVIDE A MEANS TO VISUALLY INSPECT THE TEARS SEEING IN THE CAN-CORD GUSSETLOCATED ON THE LOWER SIDE OF THE CAN, DURING THE LAST S.E.I.L.O.D.D CONDUCTED 26OCT89.THIS REQUIREMENT IS INTENDED TO BE DONE ON A ANNUAL BASIS(STBD & PORT LEGS)
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Electrical
Issued 26 October 1989
Resolved
PRIOR TO DRILLING TEST DRAW WORKS BLOWERS AND LOCKOUTS.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Electrical
Issued 26 October 1989
Resolved
PRIOR TO DRILLING ENSURE MUD PITS HAS NEGITIVE PRESSURE AND LOSS OF VENTILATION ALARMS FUCTION PROPERLY. VISUAL AND OR AUDIBLE ALARMS REQUIRED IN MANED LOCATION.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Electrical
Issued 26 October 1989
Resolved
PRIOR TO DRILLING INSTALL INVERTER IN ELECTRIC SYSTEM FOR GENERAL ALARM WHICH IS THE GAI-TRONICS SYSTEM. SYSTEM IS AC POWERED , MUST FUCTION ON BATTERY POWER WITH AC SECURED.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Unknown
Issued 26 October 1989
Resolved
WHEN FULLY CREWED AT NEXT LOCATIONCONDUCT A FIRE & ABANDON RIG DRILL IN THEPRESENCE OF A MARINE ISPECTOR.
Condition: Unknown
Due 26 October 1989
Resolved 26 October 1989
Electrical
Issued 21 August 1989
Resolved
POUR EYS FITTING ON EXPLOSION PROOF SWITCH BOX TO VENTILATION FAN IN SHAKERAREA.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
POUR EYS FITTING ON DRAW WORKS FAN MOTOR.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
PROPERLY INSTALL LOOSE WIRING BEHIND MARTIN DECKER CONSOLE WITH APPROVED JUNCTION BOXES FOR CLASS I DIVISION II AREA.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
ADD TWO BOLTS TO EXPLOSION PROOF SWITCH BOX AND BOLT TO GENERAL ALARM SILENCER ON DRILLERS CONSOLE.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
LABEL ALL SWITCHES AND CONTROLS ON DRILLERS CONSOLE.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
POUR EYS FITTING ON EXPLOSION PROOF SWITCH BOX LOCATED ON DRILLERS CONSOLE IN DRILLERS SHACK.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
TEST DRAW WORKS BLOWER MOTORS AND LOCKOUTS.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Deck/Cargo
Issued 21 August 1989
Resolved
LABEL ALL SWITCHES IN MUD PIT TO PARTICULAR SYSTEM SERVED.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
REPLACE NON-EXPLOSION PROOF PUSH BUTTON BOX WITH EXPLOSION PROOF TYPE (ADD EYS FITTING) LOCATED STBD ACCESS TO MUD PITS WITHIN FIVE FOOT RADIUS.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Navigation
Issued 21 August 1989
Resolved
TEST ALL RELIEF VALVES 4 EA AIR RECIEVERS, 6 DRY BULK.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Engineering
Issued 21 August 1989
Resolved
REPAIR FUEL LEAK ON RETURN LINE TO 2 CYLINDER LISTER COMPRESSOR ENGINE.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Accommodation/Occupational Safety
Issued 21 August 1989
Resolved
REPLACE WASTED MANIFOLDS ON HOTEL HOT WATER SERVICE. LINE IS WASTED IN FIVELOCATIONS.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Lifesaving
Issued 21 August 1989
Resolved
CONDUCT FIRE AND ABANDON SHIP DRILL.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Lifesaving
Issued 21 August 1989
Resolved
STENCIL CAPSULE CAPACITY ON THE OUTSIDE OF THE CAPSULES.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Lifesaving
Issued 21 August 1989
Resolved
RENEW THE STARBOARD DOOR WINDOW ON THE #2 CAPSULE.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Lifesaving
Issued 21 August 1989
Resolved
REPAIR THE INTERIOR LIGHTS ON THE #2 AND #4 CAPSULES.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
POUR EYS FITTING ON LIGHT BENEATH DRILL FLOOR STBD SIDE AFT.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Fire Fighting
Issued 21 August 1989
Resolved
LABEL FIRE HOSE STATION/REPAIR LEAKING VALVE IN HALLIBURTON ROOM.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
POUR EYS ON EXPLOSION PROOF BOX STBD. SIDE BELOW SHAKER AREA.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
PRIOR TO DRILLING CHECK MUD PITS POSITIVE PRESSURE AND LOSS OF VENTILATION ALARMS.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
TEST GENERAL ALARM SYSTEM AND BATTERIES.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Construction/Loadline
Issued 21 August 1989
Resolved
LABEL ALL PUMPS SWITCHES AND VALVES IN HALLIBURTON ROOM.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
TEST ALL PURGE SYSTEM AND ALARMS IN HAZARDOUS LOCATIONS.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Fire Fighting
Issued 21 August 1989
Resolved
REPLACE INOPERATIVE PRESSURE GAUGE ON FIRE PUMP #1.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
REPAIR/RENEW THE ELECTRICAL DECK PENETRATIONS AND WASTED KICK PIPES ON THE MAIN DECK AND LEVEL.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Construction/Loadline
Issued 21 August 1989
Resolved
REPAIR/RENEW THE WATERTIGHT DOOR FROM THE HOSPITAL SPACE TO THE PIPE DECK.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Construction/Loadline
Issued 21 August 1989
Resolved
REPLACE WASTED SECTIONS OF BOTH BILGE PUMP PIPING, REPLACE WASTED BOLTS ON PIPING FLANGES TO BILGE PUMP CONNECTIONS FREE UP BOTH BILGE PUMPS (FROZEN) AND PROVIDE TEST.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
LABEL ANNUCIATOR PANELS ON ALL FOUR EMD GENERATOR SETS.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
REPLACE BROKEN SIGHT GLASS ON 8 CYLINDER EMD FRESH WATER EXPANSION TANK.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Unknown
Issued 21 August 1989
Resolved
LABEL EMERGENCY FUEL SHUT OFF FOR DAY TANK SHUT OFFS LOCATED OUTSIDE OF MACHINERY SPACE.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Unknown
Issued 21 August 1989
Resolved
MAKE OPERABLE SELF CLOSING DOORS FOR MUD PITS.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Electrical
Issued 21 August 1989
Resolved
TEST ALL EMERGENCY LIGHTING AND SMOKE ALARMS.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Deck/Cargo
Issued 21 August 1989
Resolved
FASTEN PROTECTIVE GUARDS TO MUD PIT AGITATOR SHAFTS #1 AND #3.
Condition: Unknown
Due 21 August 1989
Resolved 21 August 1989
Navigation
Issued 28 September 1988
Resolved
PERMANENTLY CONNECT NAVIGATION LIGHTS TO ELECTRICAL SOURCE OF POWER, AND DISPLAY LIGHTS WHILE UNDERWAY IN ACCORDANCE WITH 72 COLREGS.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Electrical
Issued 28 September 1988
Resolved
RENEW CABLE IN MUD PITS FROM OVERHEAD TO EYS FITTING ON #1 AGITATOR PUMP (PORT SIDE) IN ACCORDANCE WITH 46 CFR 111.105.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Construction/Loadline
Issued 28 September 1988
Resolved
RE-FIT ESCAPE HATCH COVER LEADING OUT OF SACK ROOM, IN ACCORDANCE WITH 46 CFR 108.113-.115.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Deck/Cargo
Issued 28 September 1988
Resolved
DESIGNATE FORK LIFT RE-FUELING AREA AND PROVIDE EITHER 5 GALLON CAN W/ SELF-CLOSING SPOUT OR HOSE WITH "DEAD MAN" NOZZLE IN ACCORDANCE WITH 46 CFR 109.535FF.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Electrical
Issued 28 September 1988
Resolved
LINE ALL EMERGENCY BATTERY BOXES WITH LEAD OR OTHER ELECTROLYTE CORROSION RESISTANT MATERIAL IN ACCORDANCE WITH 46 CFR 111.15-5.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Electrical
Issued 28 September 1988
Resolved
DEMONSTRATE OPERATION OF EMERGENCY LIGHT(BATTLE LANTERN) ON STARBOARD SIDE OF MUD PITS IN ACCORDANCE WITH 46 CFR 112.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Construction/Loadline
Issued 28 September 1988
Resolved
RE-CONNECT AND ENSURE PROPER OPERATION OF SELF-CLOSING MECHANISM ON DOOR LOCATED STARBOARD SIDE BETWEEN MUD PUMP SPACE AND MUD PITS IN ACCORDANCE WITH 46 CFR 111.105.
Condition: Unknown
Due 28 September 1988
Resolved 28 September 1988
Unknown
Issued 1 September 1987
Resolved
CONDUCT FIRE AND BOAT DRILL.
Condition: Unknown
Due 1 September 1987
Resolved 1 September 1987
Lifesaving
Issued 1 September 1987
Resolved
CONDUCT TEST OF LIFEBOAT RELEASING GEAR.
Condition: Unknown
Due 1 September 1987
Resolved 1 September 1987
Unknown
Issued 1 September 1987
Resolved
PAINT HELO DECK MARKINGS.
Condition: Unknown
Due 1 September 1987
Resolved 1 September 1987
Electrical
Issued 1 September 1987
Resolved
REPAIR OR REPLACE INOPERATIVE GENERAL ALARM BELL LOCATED ON BOW LEG.
Condition: Unknown
Due 1 September 1987
Resolved 1 September 1987
Unknown
Issued 1 September 1987
Resolved
REPAIR FAN MOTOR FOR VENTILATION SYSTEM IN MUD PIT ROOM.
Condition: Unknown
Due 1 September 1987
Resolved 1 September 1987
Unknown
Issued 1 September 1987
Resolved
RENEW FAN MOTOR SUPPORT BRACKETS FOR MUD PIT ROOM EXHAUST SYSTEM.
Condition: Unknown
Due 1 September 1987
Resolved 1 September 1987
Unknown
Issued 1 September 1987
Resolved
REPAIR OR PEPLACE INOPERATIVE FAN IN PAINT LOCKER.
Condition: Unknown
Due 1 September 1987
Resolved 1 September 1987
Documentation
Issued 1 September 1987
Resolved
PROVIDE CRANE INSPECTION REPORT.
Condition: Unknown
Due 1 September 1987
Resolved 1 September 1987
Electrical
Issued 24 April 1986
Resolved
PROVIDE COVER FOR "PORT FWD CRANE" BREAKERS ON MAIN DIST. PANEL.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Electrical
Issued 24 April 1986
Resolved
PROVIDE INSULATING MATS OF GRATES BEHIND MAIN DIST PANEL AND SWITCHBOARDS.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Electrical
Issued 24 April 1986
Resolved
PROVIDE COVERS FOR COMPRESSOR CONTROL BOX (PORT SIDE).
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Construction/Loadline
Issued 24 April 1986
Resolved
SEAL ALL PENETRATIONS IN VARIOUS AREAS OF THE MUD PIT ROOM.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Construction/Loadline
Issued 24 April 1986
Resolved
ADJUST PORT DOOR OF MUD PIT ROOM.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Electrical
Issued 24 April 1986
Resolved
REPLACE FRAYED CABLE ON JUNCTION BOX JUST OUTSIDE PORT MUD PIT DOOR.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Unknown
Issued 24 April 1986
Resolved
REPAIR PURGE AIR SYS TO DRILLERS CONSOLE.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Engineering
Issued 24 April 1986
Resolved
PROVIDE CORRECT POLLUTION CONTAINMENT FOR FUEL TANK VENTS AND REMOVE HANDLES ON VALVES IN EACH VENT LINE.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Fire Fighting
Issued 24 April 1986
Resolved
PROVIDE TWO(2) ADDITIONAL O2 BOTTLES AND SERVICE ONE(1) FOR FIREMANS OUTFIT.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Navigation
Issued 24 April 1986
Resolved
REPAIR OR REPLACE PORT AND STARBOARD OBSTRUCTION LIGHTS.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Navigation
Issued 24 April 1986
Resolved
REPAIR OR REPLACE FOG SIGNAL.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Construction/Loadline
Issued 24 April 1986
Resolved
REPAIR OR REPLACE SELF CLOSURE STBD DOOR IN MUD PIT ROOM.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Electrical
Issued 24 April 1986
Resolved
PROVIDE SUITABLE LID FOR BATTERY BOX WHICH SERVICES INTERCOM SYS.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Electrical
Issued 24 April 1986
Resolved
REPLACE SHIELDED CABLE TO DESILTER MOTOR, TIGHTEN FITTING AND PROPERLY SECURE SHAFT COUPLING GUARD.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Electrical
Issued 24 April 1986
Resolved
REPAIR OR REPLACE EMERGENCY LIGHTS FOR THE MUD PUMP ROOM AND SINGLE P-TANK ROOM ON STARBOARD SIDE.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Lifesaving
Issued 24 April 1986
Resolved
REPAIR OR REPLACE CAPSULE #1 BRAKE RELEASE AND BREAK BAND.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Lifesaving
Issued 24 April 1986
Resolved
REPAIR OR REPLACE CAPSULE #2 BATTERY AND FIRE EXT (BC-I).
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Lifesaving
Issued 24 April 1986
Resolved
REPAIR OR REPLACE CAPSULE #3 CIRCUIT BREAKER, LUBRICATE FALLS.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Lifesaving
Issued 24 April 1986
Resolved
REPLACE IN CAPSULE #4, 3 INBOARD WINDOWS.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Fire Fighting
Issued 24 April 1986
Resolved
INSTALL CORRECT SPANNER WRENCHES AT VARIOUS FIRE STATIONS.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Electrical
Issued 24 April 1986
Resolved
PROPERLY SECURE DRILL WATER PRIME PUMP SHAFT COUPLING GUARD.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Accommodation/Occupational Safety
Issued 24 April 1986
Resolved
TEST RELIEF VALVES ON ALL PRESSURE VESSELS AT FIRST AVAILABLE OPPORTUNITY.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Accommodation/Occupational Safety
Issued 24 April 1986
Resolved
LUBRICATE AND FREE UP EYE BOLT WING NUTS ON VENT COVERS MAIN DECK HOUSE AFT.
Condition: Unknown
Due 24 April 1986
Resolved 24 April 1986
Engineering
Issued 7 November 1985
Resolved
REPAIR LOW LUBE OIL ALARM ON #2 GENERATOR DIESEL ENGINE NVC 4-78
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985
Documentation
Issued 7 November 1985
Resolved
PROVIDE A VALID FEDERAL MARITIME CERTIFICATE OF FINANCIAL RESPONSIBILITY ONBOARD VESSEL 33 CFR 13 9.96
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985
Electrical
Issued 7 November 1985
Resolved
REPAIR FAULTY REVERSE POWER RELAYS ON DIESEL GENERATORS REF: NVC 4-78 3(D) AND TEST IN PRESENSE OF COAST GUARD INSPECTOR.
Condition: Unknown
Due 7 November 1985
Resolved 7 November 1985
Lifesaving
Issued 6 March 1985
Resolved
REPLACE THE NO 3 FLOAT-FREE LIFERAFT WITH A PROPERLY SERVICED RAFT. 46 CFR 108.505.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Unknown
Issued 6 March 1985
Resolved
UNTIL SUCH TIME THAT THE NO 3 FLOAT-FREE LIFERAFT IS REPLACED, THE RIG'S TOTAL MANING IS REDUCED TO FORTY-EIGHT (48) PERSONS. NVC-4-78-(8).
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
PROVIDE EMERGENCY LIGHTS AT CAPSULE STATIONS 1 AND 2 TO ILLUMINATE ALONGSIDE THE CAPSULE LAUNCHING AREAS. 46 CFR 111.75-15(E)(4).
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Lifesaving
Issued 6 March 1985
Resolved
PROVIDE A SEA ANCHOR FOR EACH WHITAKER CAPSULE. 46 CFR 109.212(B).
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
REPAIR OR REPLACE LOSS OF VENTILATION ALARM IN MUD PIT AREA. 46 CFR 108.185.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
PROVIDE EMERGENCY LIGHTS AT THE STOWAGE POSITION OF LIFERAFT STATION NO 1, NO 2, AND NO 3. 46 CFR 111.75-15(E)(4).
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Unknown
Issued 6 March 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU [name withheld]549294.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Electrical
Issued 6 March 1985
Resolved
REPAIR OR REPLACE FAULTY OVERSPEED TRIP DEVICES, LOW LUBE OIL ALARMS, AND REVERSE POWER RELAYS ON DIESEL GENERATORS. NVIC 4-78-3(D).
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Deck/Cargo
Issued 6 March 1985
Resolved
REPLACE PLASTIC SIGHT GLASS ON FUEL OIL DAY TANK WITH HEAT RESISTANT SIGHT GLASS. 46 CFR 58.50-10.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Deck/Cargo
Issued 6 March 1985
Resolved
PROVIDE BULK BARITE AND CEMENT TANKS OPEN FOR INTERNAL INSPECTION. 46 CFR 54.10-3.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Navigation
Issued 6 March 1985
Resolved
PROVIDE ADEQUATE MARKING OF GENERAL ALARM ON DRILL FLOOR. 46 CFR 108.625.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Lifesaving
Issued 6 March 1985
Resolved
REPLACE THE BILLY PUGH PERSONNEL BASKET. 46 CFR 108.527.
Condition: Unknown
Due 6 March 1985
Resolved 6 March 1985
Unknown
Issued 16 September 1983
Resolved
PROVIDE DOCUMENTATION OF THE PREVIOUS INSPECTIONS OF THE FRACTURES ON THE STARBOARD LEG JACKING TEETH PRIOR TO COMMENCING DRILLING.
Condition: Unknown
Due 16 September 1983
Resolved 16 September 1983
Unknown
Issued 16 September 1983
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE [name withheld], DN549294.
Condition: Unknown
Due 16 September 1983
Resolved 16 September 1983
Unknown
Issued 16 September 1983
Resolved
REPLACE THE GENERATOR COOLING WATER SUCTION VALVE.
Condition: Unknown
Due 16 September 1983
Resolved 16 September 1983
Unknown
Issued 16 September 1983
Resolved
CONDUCT AN UNDERWATER SURVEY OF ALL LEGS BELOW THE SPUD CANS IN THE PRE- SENCE OF A COAST GUARD INSPECTOR PRIOR TO COMMENCING DRILLING.
Condition: Unknown
Due 16 September 1983
Resolved 16 September 1983
Electrical
Issued 5 March 1983
Resolved
REPAIR OBSTRUCTION LIGHTS TO MAKE OPERATIONAL.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Accommodation/Occupational Safety
Issued 5 March 1983
Resolved
REPAIR/REPLACE INOPERABLE RELIEF VALVES ON LEFT AND RIGHT HOT WATER HEATERS.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Construction/Loadline
Issued 5 March 1983
Resolved
REINSTALL WATER TIGHT DOOR TO ENGINE ROOM AND REPLACE MISSING DOG ON WATER TIGHT DOOR TO SACK ROOM.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
PROVIDE EMERGENCY LIGHTS FOR RED FOX ROOM AND STAIRWELL FROM ENGINE ROOM.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
REPAIR/REPLACE INOPERABLE EMERGENCY LIGHTS FOR ENGINE ROOM AND MUD PUMP ROOM.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Fire Fighting
Issued 5 March 1983
Resolved
PROVIDE APPLICATOR FOR FIRE STATION 56A.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Accommodation/Occupational Safety
Issued 5 March 1983
Resolved
PROVIDE GUARDS ON BELTS TO WATER MAKER UNITS.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Unknown
Issued 5 March 1983
Resolved
PROVIDE MATTING FOR MAIN SWITCHBOARD.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Fire Fighting
Issued 5 March 1983
Resolved
REPAIR/REPLACE INOPERABLE GAUGES ON BOTH FIRE PUMPS AND NO.2 DRILL WATER- PUMP.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Deck/Cargo
Issued 5 March 1983
Resolved
PROVIDE LOAD CHARTS FOR ALL 3 CRANES AND SIGNAL CHART FOR WHEELER CRANES.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Documentation
Issued 5 March 1983
Resolved
PROVIDE STABILITY LETTER ABOARD RIG.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Documentation
Issued 5 March 1983
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL [name withheld], DN549294.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
(REQUIREMENT E16 CONTINUED)VOLUME AND FLOW INDICATOR, RETURN FLOW INDICATORAND MUD VOLUME TOTALIZER, OPERATIONAL. ENSURE INDIVIDUAL AIR PURGE
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
(REQUIREMENT E16 CONTINUED) INDICATORS FOR ABOVE UNITS ARE ACCURATE AND OP-ERATIONAL, ITEM TO BE COMPLETED PRIOR TO DRILLIING.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Fire Fighting
Issued 5 March 1983
Resolved
REFILL CO2 BOTTLES ON THESE FIXED SYSTEM; (A) PAINT LOCKER, (B) ENGINE ROOMBOTTLE NEAREST SWITCHBOARD.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
DEMONSTRATE REVERSE POWER REPLAY AND OVERSPEED TRIP ON NO.3 EMD.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
DEMONSTRATE REVERSE POWER RELAY ON NO. 2 EMO.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
IN THE SHAKER AREA: (A) PROVIDE EYS SEAL FOR PHONE JUNCTION BOX. (B) PRO- VIDE EYS SEAL FOR SKID PUMP STARTER. (C) REMOVE DEAD END SENS0R CABLE
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
(REQUIREMENT E14 CONTINUED) NEAR PHONE, (D) PROVIDE EYS SEAL FOR FORWARD SHAKER MOTOR, (E) DEMONSTRATE VENTILATION OVERPRESSURE AND LOSS OF OVER-
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
(REQUIREMENT E14 CONTINUED) PRESSURE ALARM FOR LOGGING UNIT.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
IN THE MUD PIT AREA: (A) PROVIDE EYS SEAL ON FAN MOTOR, (B) PROVIDE EYS SEAL FOR PHONE JUNCTION BOX, (C) PROVIDE EXPLOSION PROOF BATTLE LANTERN,
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
(REQ. E15 CONTINUED) (D) SEAL BULKHEAD PENETRATIONS NEAR BOTH WATERTIGHT DOORS, (E) ADJUST PORT WATERTIGHT DOOR, (F) CROP AND RENEW WASTED BULKHEAD
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
(G) PROVIDE LOSS OF VENTILATION ALARM FOR VENTILATION FLOW FROM THE PUMP- ROOM TO THE MUD PITS.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
ON THE DRILL FLOOR: (A) PROVIDE EYS FOR STARTER BRAKE, (B) PROVIDE EYS SEALS FOR DYNAMATIC CONTRACTORS, (C) MAKE ROTARY AND DRAWWORKS DC MOTOR
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
(REQUIREMENT E16 CONTINUED) CONNECTIONS EXPLOSION PROOF OR AIR PURGED, (D) MAKE INSTALLED AIR PURGE SYSTEM TO DRILLERS CONSOLE GAS DETECT UNIT, PIT
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Construction/Loadline
Issued 5 March 1983
Resolved
CONDUCT DRYDOCKING OR SPECIAL EXAM OF RIG.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Lifesaving
Issued 5 March 1983
Resolved
PROVIDE 12 HAND HELD RED DISTRESS SIGNALS TO EACH LIFEBOAT.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Lifesaving
Issued 5 March 1983
Resolved
REPLACE WINCH HAND CRANK BELT GUARD ON NO. 1 LIFEBOAT.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Navigation
Issued 5 March 1983
Resolved
RELOCATE PORT AND STARBOARD SIDELIGHT SCREENS OUTBOARD OF FLOODLIGHT AND OBSTRUCTION LIGHT PEDESTALS. PAINT SCREENS FLAT BLACK. REPLACE BROKEN
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Navigation
Issued 5 March 1983
Resolved
(REQUIREMENT D8 CONTINUED) GLOBE ON STARBOARD LIGHT.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Lifesaving
Issued 5 March 1983
Resolved
PROVIDE EMERGENCY LIGHTING FOR LIFEBOAT AND LIFERAFTS STATIONS.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Lifesaving
Issued 5 March 1983
Resolved
PROVIDE ADDITIONAL EMERGENCY LIGHTS TO PROVIDE ADEQUATE ILLUMINATION IN QUARTERS TO PROVIDE FOR SAFE EXIT OF PERSONNEL.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Documentation
Issued 5 March 1983
Resolved
AUTHORIZED MANNING REDUCED TO 48 (TOTAL PERSONS ABOARD) UNTIL SUCH TIME AS 3-20 MAN RAFTS REINSTALLED ABOARD RIG.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Unknown
Issued 5 March 1983
Resolved
HAVE LOADLINE SURVEY CONDUCTED.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Documentation
Issued 5 March 1983
Resolved
PROVIDE CRANE RECORD BOOK ABOARD RIG.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Lifesaving
Issued 5 March 1983
Resolved
HAVE OUTDATED INFLATABLE LIFERAFTS AND HYDROSTATIC RELEASES SERVICED.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Documentation
Issued 5 March 1983
Resolved
PROVIDE APPROVED OPERATING MANUAL ABOARD RIG.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Electrical
Issued 5 March 1983
Resolved
PROVIDE HANDLE FOR FUEL OIL DAY TANK SUCTION VALVE.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Lifesaving
Issued 5 March 1983
Resolved
REPAIR NO. 1 LIFEBOAT WINCH CONTROLLER SWITCH.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Navigation
Issued 5 March 1983
Resolved
PROVIDE AN ADDITIONAL BLACK BALL (TOTAL OF THREE) ABOARD RIG.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Navigation
Issued 5 March 1983
Resolved
MAKE FOG HORN OPERATIONAL.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Fire Fighting
Issued 5 March 1983
Resolved
PROVIDE COMPLETE DOCUMENTATION OF SERVICING OF PORTABLE, SEMIPORTABLE AND FIXED FIRE EXTINGUISHERS IAW 46 CFR 109.435. SERVICING SHOULD BE DONE AS
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Fire Fighting
Issued 5 March 1983
Resolved
(REQUIREMENT D16 CONTINUED) CLOSE AS PRACTICAL TO ANNUAL CG INSPECTION AND MASTERS RECORD IS TO INCLUDE EXTINGUISHER NO.; INSPECTION OR TESTING DONE;
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Fire Fighting
Issued 5 March 1983
Resolved
(REQUIREMENT D16 CONTINUED) WEIGHT AND HYDRO DATE OF N2 CYLINDERS; AND NAMEAND COMPANY OF PERSON COMPLETING SERVICING.
Condition: Unknown
Due 5 March 1983
Resolved 5 March 1983
Unknown
Issued 16 August 1982
Resolved
HYDROSTATICALLY TEST AIR RECEIVER UNDER DRILL FLOOR TO 1 1/4 MAWP IN PRESCENCE OF CG INSPECTOR TO PROVE SOUNDNESS OF HEAVILY PITTED SHELL.
Condition: Unknown
Due 16 August 1982
Resolved 16 August 1982
Accommodation/Occupational Safety
Issued 9 August 1982
Resolved
MAKE RELIEF VALVE ON DRILL FLOOR AIR RECEIVER AVAILABLE FOR TEST.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Lifesaving
Issued 9 August 1982
Resolved
PROVIDE ADEQUATE INDICATION FOR GENERAL ALARM IN BELLS AND/OR FLASHING LIGHTS FOR GENERATOR ROOM.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Lifesaving
Issued 9 August 1982
Resolved
PROVIDE 500' AUXILIARY LINE FOR LINE THROWING GUN.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Documentation
Issued 9 August 1982
Resolved
HAVE ABS ANNUAL LOADLINE SURVEY CONDUCTED.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Documentation
Issued 9 August 1982
Resolved
HAVE ALTERNATE MASTERS ENDORSED ON MARINE DOCUMENT.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Fire Fighting
Issued 9 August 1982
Resolved
MARK FIRE STATIONS AT PORT LEG AND SHAKER HOUSE. PROVIDE SPANNERS AT PORT LEG, SHAKER, #7 AND #53.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Electrical
Issued 9 August 1982
Resolved
REPAIR QUARTERS AND MACHINERY SPACE VENT SHUTDOWNS.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Electrical
Issued 9 August 1982
Resolved
PROVIDE GUARD ON LIGHTS IN LAUNDRY STORES, UPPER QUARTERS STOREROOM AND RADIO ROOM.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Lifesaving
Issued 9 August 1982
Resolved
HAVE HYDROSTATIC RELEASES FOR PORT AND STBD LIFERAFTS TESTED AND TAGS STAMPED.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Navigation
Issued 9 August 1982
Resolved
REMOVE OR MAKE EXPLOSION PROOF, PHONE IN SHAKER HOUSE AND MUD PIT.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Lifesaving
Issued 9 August 1982
Resolved
PROVIDE 14 ADDITIONAL LIFE JACKETS WITH REFLECTIVE TAPE, LIGHTS AND WHISTLE FOR 125% COVERAGE.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Documentation
Issued 9 August 1982
Resolved
INSCRIBE AND PAINT NAME ON STBD BOW. PAINT STBD LOADLINE.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Lifesaving
Issued 9 August 1982
Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR LIFE BOATS:STBD-3 SPARE BATTERIES AND 1BULB FOR FLASLIGHTS, REPLACE SMOKE SIGNALS, PARACHUTES FLARES, WATER.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Lifesaving
Issued 9 August 1982
Resolved
STBD-PROVIDE FISHING KIT. PORT-REPLACE LIFE LINE AROUND CAPSULE, SMOKE SIG-NALS, PARACHUTE FLARES, WATER AND PROVIDE FISHING KIT.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Deck/Cargo
Issued 9 August 1982
Resolved
MAKE ALL MUD PUMP RELIEF VALVES AVAILABLE FOR TEST.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Accommodation/Occupational Safety
Issued 9 August 1982
Resolved
MAKE PERMANENT REPAIRS TO DECK UNDER #3 AGITATOR IN MUD PIT.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Electrical
Issued 9 August 1982
Resolved
REPAIR OR REMOVE TACHOMETERS ON ALL GENERATORS.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982
Navigation
Issued 9 August 1982
Resolved
MAKE FOG HORN OPERATIONAL WITH PROPER TIMING SEQUENCE OF 2 SECONDS ON AND 18 OFF.
Condition: Unknown
Due 9 August 1982
Resolved 9 August 1982