Records from 1981 to 2017. Most recent: inspection, 13 June 2017.
Inspection history · 49
13 June 2017
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6174799
12 January 2010
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3662609
30 January 2009
Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3402551
17 March 2008
Internal Structural Exam · Cargo Tank Internal · MTSA Verification · Examination of Repairs · Ballast Water Examination · Hull Examination · Periodic Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3166338
19 January 2007
Re-Inspection · Ballast Water Examination · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2867834
31 January 2006
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2623729
20 April 2005
MTSA Verification · COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2260495
5 March 2005
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2322047
8 April 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1984075
21 April 2003
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1766059
21 April 2003
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1771152
7 August 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1658024
18 April 2002
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1484993
9 August 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 112912
19 April 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453878
21 January 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 114929
20 April 2000
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1397297
16 December 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395076
7 January 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1400689
21 December 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406018
16 April 1996
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 72129
20 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 171730
20 December 1995
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1183230
13 December 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 882506
13 December 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451023
21 December 1994
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1455221
13 February 1994
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396050
2 December 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470893
18 December 1992
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435351
27 August 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 945601
6 August 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 937963
14 November 1990
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899666
5 October 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 901131
6 September 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1238466
5 September 1990
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1216052
19 July 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1226291
20 January 1990
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1239358
30 August 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 891754
9 September 1988
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1040611
17 September 1987
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1314890
2 February 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003927
20 November 1986
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321111
24 January 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998362
15 January 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 984770
20 November 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282532
27 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283368
22 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964597
3 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964928
18 February 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275041
Lifesaving › Lifebuoys › Serviceable
Issued 30 January 2009
Resolved
Plugs on two lifebouys were wasted.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2009
Resolution: Plugs replaced.
Electrical › Electrical Distribution System (service)
Issued 18 April 2002
Resolved
Power supply boxes underneath the pilothouse control panel needed to be secured.
Condition: Design Flaw
Due 18 April 2002
Resolved 18 April 2002
Resolution: Boxes secured.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 April 2002
Resolved
Lifeline on lifebuoy on port bridge wing wasted away from sun exposure.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: Lifeline replaced.
Communications › Radio Communications
Issued 18 April 2002
Resolved
Mayday placard missing from radio installation. LEGACY COMPONENT DESC: Mayday placard
Condition: Unknown
Due 18 April 2002
Resolved 18 April 2002
Resolution: Placard supplied.
Pollution Prevention/Response › Prevention Equipment
Issued 18 April 2002
Resolved
Waste management plan missing. LEGACY COMPONENT DESC: Waste Management Program
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 April 2002
Resolution: Waste management plan posted.
Electrical › Mast
Issued 18 April 2002
Resolved
Masthead light damaged.
Condition: Damaged By Earlier Event
Due 18 April 2002
Resolved 18 April 2002
Resolution: Light fixed.
Documentation
Issued 6 August 1991
Resolved
UPDATE FUEL OIL TRANSFER PROCEDURES TO COMPLY WITH 33CFR155 AND INCLUDE _x001C_ LIQUID MUD SYSTEM.
Condition: Unknown
Due 17 October 1991
Resolved 17 October 1991
Engineering
Issued 5 September 1990
Resolved
REPLACE PUSH-ON FUEL LINE FITTINGS WITH COAST GUARD APPROVED TYPE FITTINGS ON BOW THRUSTER DIESEL ENGINE.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Deck/Cargo
Issued 5 September 1990
Resolved
HYDRO-TEST DIESEL AND LIQUID MUD CARGO TRANSFER HOSES AT 1.5 TIMES MAXIMUM ALLOWABLE WORKING PRESSURE AND PROVIDE DOCUMENTATION OF TESTS TO THE COAST GUARD.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Engineering
Issued 5 September 1990
Resolved
CLEAN UP EXCESSIVE OIL/FUEL IN DRIP PAN AROUND BOW THRUSTER DIESEL ENGINE.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Engineering
Issued 5 September 1990
Resolved
PROVIDE THE PILOTHOUSE CONTROL STATION WITH MEANS TO AND MONITOR SPEED AND DIRECTION OF SHAFT ROTATION IN ACCORDANCE WITH NVIC 1-78.
Condition: Unknown
Due 5 September 1990
Resolved 5 September 1990
Electrical
Issued 9 September 1988
Resolved
PROVIDE ELECTRICAL MATTING IN FRONT OF SWITCHBOARD.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Documentation
Issued 9 September 1988
Resolved
PROVIDE OIL TRANSFER PROCEDURES FOR CARGO DISCHARGE AND BUNKERING.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Engineering
Issued 9 September 1988
Resolved
REPAIR/RENEW BILGE ALARM SENSORS FOR FORWARD PASSAGEWAY AND STEERING GEAR SPACE.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Fire Fighting
Issued 9 September 1988
Resolved
HAVE ALL PORTABLE FIRE EXTINGUISHERS SERVICED. FORWARD SERVICE REPORT TO USCG MSO CORPUS CHRISTI, TX.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Electrical
Issued 9 September 1988
Resolved
HAVE ENGINE AUTOMATION PROTECTION SYSTEM SERVICED AND FORWARD SERVICE REPORT TO USCG MSO CORPUS CHRISTI, TX
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Lifesaving
Issued 15 January 1986
Resolved
REPLACE OR REPAIR INOPERATIVE LINE THROWING GUN.
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986
Electrical
Issued 15 January 1986
Resolved
REPAIR VENTILATION SHUT-DOWN SWITCH LOCATED IN WHEELHOUSE.
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986
Accommodation/Occupational Safety
Issued 15 January 1986
Resolved
REPLACE FAULTY ELECTRICAL SWITCH ON PORTABLE WATER PUMP.
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986
Electrical
Issued 15 January 1986
Resolved
STENCIL ALL REMOTE SHUT-DOWN SWITCHES.
Condition: Unknown
Due 15 January 1986
Resolved 15 January 1986