MAURY USCG vessel records
← All vessels

LOOP LOADER

LOOP LOADER is a 1980 offshore supply vessel. The Coast Guard has recorded 14 inspections since 2016, most recently in June 2026, along with 37 deficiencies and 2 casualty investigations between 2013 and 2014.

Records from 2013 to 2026. Most recent: inspection, 10 June 2026.

Built
1980
Last inspected
10 June 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDH8485
Flag
UNITED STATES
Maury page id
psix-52860

Inspections, by type

Years with a record 10 calendar years (2016–2026)
The 14 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)81.6 ft × 26.0 ft × 9.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNORTH AMERICAN SHIPBUILDI · LAROSE LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 February 2026 · expires 31 March 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 14

10 June 2026 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8381606
11 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8157039
16 April 2024 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7893532
20 December 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7843056
29 January 2021 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7132844
24 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7064489
30 March 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6932990
10 February 2020 Hull Examination · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6905961
22 February 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6630779
28 January 2019 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6615868
31 January 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6346490
24 January 2017 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6076463
19 January 2017 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6074246
2 February 2016 Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5807933

Deficiency record · 37

10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 10 June 2026 Resolved
Steering required to be operational. Non-followup not operational.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 10 June 2026
Resolution: Corrected on the spot. electrical connection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2026 Resolved
Eletrical hazards shall be minimized. Multiple J-boxes open in engineroom.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 10 June 2026
Resolution: Covers installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2026 Resolved
Exhaust lagging required for hot surfaces. exhaust leak on STBD MDE and lagging missing in multiple areas.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 10 June 2026
Resolution: Leak repaired and lagging installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2026 Resolved
Switchboard installations shall meet a standard. Shore power cable entering swith board thru a vent.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 10 June 2026
Resolution: Cable remove and vent cover replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 June 2026 Resolved
Pressure guages on pressure vessels shall read 1.2 to not more than 2 timesthe PRV setting. PRV set to 175 guage 0-160.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 29 June 2026
Resolution: Gauge replaced
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 10 June 2026 Resolved
Potable water head tank needs a bracket. Head tank held in place with line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 29 June 2026
Resolution: Bracket replaced.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 16 April 2024 Resolved
Maste ris responsible for cunducting drills within 24 hours of leaving port if more than 25% of crew have been replaced at the port. Drills unsat. Prove proper logging of and evaluation of drills in USCG presence.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2024
Resolved 19 April 2024
Resolution: Conducted drills; all sat.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 16 April 2024 Resolved
Vessel subject to part III of title III of the Communications Act must, at a minimum, be equipped with VHF-DSC radiotelephone. Radio did not have MMSI or GPS integrated into DSC / replace. Cite: 47 CFR 80.905(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2024
Resolved 19 April 2024
Resolution: Repaired.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 16 April 2024 Resolved
Inspections to include but not limited to: fire & boat drills, prior to departure tests, hatches and openings are required to be logged in the vessels log book. Update log book accordingly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Logged.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 16 April 2024 Resolved
Every vessel must have PFD donning instructions. Found improper PFD type instructions for PFD's onboard. Replace. Cite: 46 CFR 97.39-1(a) (OLD I)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024 Resolved
All electrical cable power cable should be checked for proper insulation and resistance to ground and between cinductors. Power panel ground detection found inoperable. Repair/replace. Cite: 46 CFR 110.05-15(b) (17) (OLD-OLD J)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 16 April 2024 Resolved
FO transfer procedures must be posted in vicinity of transfer station. No procedures poated. repair/replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024 Resolved
The installation of all systems interior communication must be in accordance with subchapter J (electrical engineering), Sound powered phone in engine room painted over, unable to determine channel. Repair/replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024 Resolved
The installation of all marine engineering systems must be in accordance with subchapter J. Found numerous loose end wires and hydraulic fluid leaks under main control console on bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024 Resolved
The installation of all marine engineering systems must be in accordance with subchapter J. Alarm for WTD and / or STBD MDE JW sounding continuously. Troubleshoot to repair/replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Repaired.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 January 2021 Resolved
Each vessel must carry a category 1406 Mhz satellite EPRIB meeting the requirements of 47 CFR part 80. The callsign on the EPIRB registration was not correct.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2021
Resolved 8 March 2021
Resolution: Vessel reregistared EPIRB info.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 January 2021 Resolved
Vessel shall have appropriate charts and publications for the intended voyage. The charts were dated for 2019 without corrections. The Light List was dated 2019. The Coast Pilot was dated 2020. The vessel did not have a chart correction kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2021
Resolved 8 March 2021
Resolution: Vessel had new charts delivered.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 January 2021 Resolved
Non-metallic flexible hoses must be IAW SAE J1942. The Port side steering hydraulic hose on the ram has a leak and has duct tape over the hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021
Resolved 8 March 2021
Resolution: Vessel replaced steering gear hose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 January 2021 Resolved
Watertight doors shall be capable for securing the doors watergtight. The gasket to the engine room was replaced.
Action required: 10 - Deficiency Rectified
Due 29 January 2021
Resolved 29 January 2021
Resolution: Vessel replaced gasket for engine room door.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 January 2021 Resolved
Lifejacket instruction placards did not match the lifejackets for all types onboard.
Action required: 10 - Deficiency Rectified
Due 29 January 2021
Resolved 29 January 2021
Resolution: Vessel made copy of lifejact placard and posted it where necessary.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 February 2019 Resolved
Life floats deteriorated and not operational, structurally deficienant.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: Deteriorated Life floats were replaced with servicable life floats
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 February 2019 Resolved
Life floats not stowed in float free condition, float free link not attached.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: Life floats were installed with painter line attached to the weak link.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 22 February 2019 Resolved
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: Bilge alarm was replaced and proved operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 February 2019 Resolved
Gaskets on watertight doors to engine room are both unservicable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: Gaskets on water tight doors to the engine room were replaced and proved operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 January 2019 Resolved
Port MDE experienced major overheat warping critical engine components. Deficiencies which affect the safety of the vsl shall be corrected to the satisfaction of the OCMI.
Action required: 10 - Deficiency Rectified
Resolved 28 January 2019
Resolution: VSL replaced Port engine in kind. Power trials were conducted on the evening of Saturday the 25th with ABS survey Amed present. ABS's survey was forwarded to Houma DMI.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 January 2018 Resolved
Provide emergency lighting at embarkation stations, port + starboard IAW 46 CFR 111.75-15 (OLD "J").
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 1 February 2018
Resolution: Vessel installed e-lighting IAW regulation.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 19 January 2017 Resolved
Rudder angle indicator inop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: 3rd party repaired indicator.
Lifesaving › Lifefloat › Float-free Link
Issued 19 January 2017 Resolved
Unable to read specs on weak link for life floats.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: New weak link for life floats added.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 January 2017 Resolved
reflective tape for 2 PFDs need replacing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: Replaced reflective tape on 2 PFDs.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 January 2017 Resolved
reflective tape on all ring Bouys needs replacing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: reflective tape on all ring Bouysreplaced.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 19 January 2017 Resolved
rpm gauge inop
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: rpm gauge repaired.
Construction/Loadline › Structures › Door
Issued 19 January 2017 Resolved
Water tight door indicator inop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 20 January 2017
Resolution: Water tight door Indicator repaired.
Lifesaving › Rocket Parachute Flares › General
Issued 19 January 2017 Resolved
Vessel only has 6.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: Vessel has 12 rocket flares.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 19 January 2017 Resolved
Lagging missing on 1ft section of the port main exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 20 January 2017
Resolution: Lagging replaced.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 January 2017 Resolved
Wrong call sign on FCC Bridge to bridge and safety cert.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: Corrected call sign on FCC Bridge to bridge and safety cert.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 2 February 2016 Resolved
Provide protective guards for jacket water and stbd fuel storage tank sight glass.
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 2 February 2016
Resolution: Vessel rep provided proper guards for sight glass prior to completion of inspection.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 February 2016 Resolved
Replaced Life floats and Life Ring water activated lights with approved 6V batteries.
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 2 February 2016
Resolution: Vessel rep provided approved 6V battery prior to the completion of inspection.

Casualty record · 2

7 April 2013Routine · role: Involved in a Marine Casualty · activity 4564738
28 April 2014Routine · role: Involved in a Marine Casualty · activity 4847747
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record