LOOP LOADER

LOOP LOADER is a 1980 offshore supply vessel. The Coast Guard has recorded 73 inspections since 1981, most recently in June 2026, along with 113 deficiencies and 2 casualty investigations between 2013 and 2014.

Records from 1981 to 2026. Most recent: inspection, 10 June 2026.

Built
1980
Last inspected
10 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH8485
Flag
UNITED STATES
367658480
Maury page id
psix-52860

Inspections, by type

…with no type recorded16
Years with a record 42 calendar years (1981–2026)
The 73 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)81.6 ft × 26.0 ft × 9.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderNORTH AMERICAN SHIPBUILDI · LAROSE LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 February 2026 · expires 31 March 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH8485MMSI 367658480 · active · compulsorily equipped · granted 24 January 2025, expires 24 February 2035
WYQ7947MMSI 367018970 · expired · compulsorily equipped · granted 17 February 2005, cancelled 23 May 2015
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 73

10 June 2026 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8381606
11 June 2025 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8157039
16 April 2024 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7893532
20 December 2023 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7843056
29 January 2021 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7132844
24 September 2020 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7064489
30 March 2020 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6932990
10 February 2020 Hull Examination · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6905961
22 February 2019 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6630779
28 January 2019 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6615868
31 January 2018 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6346490
24 January 2017 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6076463
19 January 2017 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6074246
2 February 2016 Administrative Inspection · COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5807933
1 May 2014 Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4848090
25 March 2014 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4822255
3 February 2012 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4236752
11 January 2012 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4222994
7 February 2011 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3939423
5 February 2010 MTSA Verification · Internal Structural Exam · Examination of Repairs · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3675658
2 February 2009 Re-Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3420898
19 May 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3210887
20 March 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3188987
5 February 2007 Deficiency Check · Examination of Repairs · Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2867113
8 January 2007 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2852280
5 January 2007 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2851717
7 February 2006 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2635123
26 September 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2501565
25 May 2005 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2368092
9 March 2005 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2306188
24 February 2005 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2298816
16 February 2005 Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2293918
9 February 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2002870
3 November 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1979469
3 July 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1833764
21 June 2002 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1688017
14 February 2002 Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1486436
8 February 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1366161
25 January 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 770248
21 January 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 200179
18 April 2000 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464939
8 February 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384355
26 July 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 680555
10 February 1999 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213967
10 February 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1365054
22 January 1998 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446592
15 April 1997 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418153
6 February 1997 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380755
4 July 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764997
30 June 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 200180
6 February 1996 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1390194
2 May 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355237
9 February 1995 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456243
17 February 1994 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354571
26 April 1993 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 832827
16 February 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387297
22 April 1992 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1354136
12 April 1991 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 914331
22 February 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 910577
5 April 1990 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1232408
25 July 1989 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199980
1 March 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 887695
16 March 1988 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 976081
8 October 1987 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1015346
18 September 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316461
6 March 1987 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1325612
12 March 1986 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001512
13 March 1985 Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1001511
13 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287905
13 March 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1292042
17 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281309
28 March 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 967919
27 March 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964444

Deficiency record · 113

10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 10 June 2026 Resolved
Steering required to be operational. Non-followup not operational.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 10 June 2026
Resolution: Corrected on the spot. electrical connection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2026 Resolved
Eletrical hazards shall be minimized. Multiple J-boxes open in engineroom.
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 10 June 2026
Resolution: Covers installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 June 2026 Resolved
Exhaust lagging required for hot surfaces. exhaust leak on STBD MDE and lagging missing in multiple areas.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 10 June 2026
Resolution: Leak repaired and lagging installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 10 June 2026 Resolved
Switchboard installations shall meet a standard. Shore power cable entering swith board thru a vent.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 10 June 2026
Resolution: Cable remove and vent cover replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 10 June 2026 Resolved
Pressure guages on pressure vessels shall read 1.2 to not more than 2 timesthe PRV setting. PRV set to 175 guage 0-160.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 29 June 2026
Resolution: Gauge replaced
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 10 June 2026 Resolved
Potable water head tank needs a bracket. Head tank held in place with line.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 29 June 2026
Resolution: Bracket replaced.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 16 April 2024 Resolved
Maste ris responsible for cunducting drills within 24 hours of leaving port if more than 25% of crew have been replaced at the port. Drills unsat. Prove proper logging of and evaluation of drills in USCG presence.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2024
Resolved 19 April 2024
Resolution: Conducted drills; all sat.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 16 April 2024 Resolved
Vessel subject to part III of title III of the Communications Act must, at a minimum, be equipped with VHF-DSC radiotelephone. Radio did not have MMSI or GPS integrated into DSC / replace. Cite: 47 CFR 80.905(a)
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 22 April 2024
Resolved 19 April 2024
Resolution: Repaired.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Emergency preparedness
Issued 16 April 2024 Resolved
Inspections to include but not limited to: fire & boat drills, prior to departure tests, hatches and openings are required to be logged in the vessels log book. Update log book accordingly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Logged.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 16 April 2024 Resolved
Every vessel must have PFD donning instructions. Found improper PFD type instructions for PFD's onboard. Replace. Cite: 46 CFR 97.39-1(a) (OLD I)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024 Resolved
All electrical cable power cable should be checked for proper insulation and resistance to ground and between cinductors. Power panel ground detection found inoperable. Repair/replace. Cite: 46 CFR 110.05-15(b) (17) (OLD-OLD J)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 16 April 2024 Resolved
FO transfer procedures must be posted in vicinity of transfer station. No procedures poated. repair/replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024 Resolved
The installation of all systems interior communication must be in accordance with subchapter J (electrical engineering), Sound powered phone in engine room painted over, unable to determine channel. Repair/replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024 Resolved
The installation of all marine engineering systems must be in accordance with subchapter J. Found numerous loose end wires and hydraulic fluid leaks under main control console on bridge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 April 2024 Resolved
The installation of all marine engineering systems must be in accordance with subchapter J. Alarm for WTD and / or STBD MDE JW sounding continuously. Troubleshoot to repair/replace.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2024
Resolved 19 April 2024
Resolution: Repaired.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 29 January 2021 Resolved
Each vessel must carry a category 1406 Mhz satellite EPRIB meeting the requirements of 47 CFR part 80. The callsign on the EPIRB registration was not correct.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2021
Resolved 8 March 2021
Resolution: Vessel reregistared EPIRB info.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 January 2021 Resolved
Vessel shall have appropriate charts and publications for the intended voyage. The charts were dated for 2019 without corrections. The Light List was dated 2019. The Coast Pilot was dated 2020. The vessel did not have a chart correction kit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2021
Resolved 8 March 2021
Resolution: Vessel had new charts delivered.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 29 January 2021 Resolved
Non-metallic flexible hoses must be IAW SAE J1942. The Port side steering hydraulic hose on the ram has a leak and has duct tape over the hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 February 2021
Resolved 8 March 2021
Resolution: Vessel replaced steering gear hose.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 29 January 2021 Resolved
Watertight doors shall be capable for securing the doors watergtight. The gasket to the engine room was replaced.
Action required: 10 - Deficiency Rectified
Due 29 January 2021
Resolved 29 January 2021
Resolution: Vessel replaced gasket for engine room door.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 29 January 2021 Resolved
Lifejacket instruction placards did not match the lifejackets for all types onboard.
Action required: 10 - Deficiency Rectified
Due 29 January 2021
Resolved 29 January 2021
Resolution: Vessel made copy of lifejact placard and posted it where necessary.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 22 February 2019 Resolved
Life floats deteriorated and not operational, structurally deficienant.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: Deteriorated Life floats were replaced with servicable life floats
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 22 February 2019 Resolved
Life floats not stowed in float free condition, float free link not attached.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: Life floats were installed with painter line attached to the weak link.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 22 February 2019 Resolved
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: Bilge alarm was replaced and proved operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 22 February 2019 Resolved
Gaskets on watertight doors to engine room are both unservicable.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 February 2019
Resolution: Gaskets on water tight doors to the engine room were replaced and proved operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 January 2019 Resolved
Port MDE experienced major overheat warping critical engine components. Deficiencies which affect the safety of the vsl shall be corrected to the satisfaction of the OCMI.
Action required: 10 - Deficiency Rectified
Resolved 28 January 2019
Resolution: VSL replaced Port engine in kind. Power trials were conducted on the evening of Saturday the 25th with ABS survey Amed present. ABS's survey was forwarded to Houma DMI.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 January 2018 Resolved
Provide emergency lighting at embarkation stations, port + starboard IAW 46 CFR 111.75-15 (OLD "J").
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 1 February 2018
Resolution: Vessel installed e-lighting IAW regulation.
Communications › Alarms/Indicators › Rudder Angle Indicator
Issued 19 January 2017 Resolved
Rudder angle indicator inop.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: 3rd party repaired indicator.
Lifesaving › Lifefloat › Float-free Link
Issued 19 January 2017 Resolved
Unable to read specs on weak link for life floats.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: New weak link for life floats added.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 19 January 2017 Resolved
reflective tape for 2 PFDs need replacing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: Replaced reflective tape on 2 PFDs.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 January 2017 Resolved
reflective tape on all ring Bouys needs replacing.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: reflective tape on all ring Bouysreplaced.
Communications › Alarms/Indicators › Engine RPM Gauge/Indicator
Issued 19 January 2017 Resolved
rpm gauge inop
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: rpm gauge repaired.
Construction/Loadline › Structures › Door
Issued 19 January 2017 Resolved
Water tight door indicator inop.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 20 January 2017
Resolution: Water tight door Indicator repaired.
Lifesaving › Rocket Parachute Flares › General
Issued 19 January 2017 Resolved
Vessel only has 6.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: Vessel has 12 rocket flares.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 19 January 2017 Resolved
Lagging missing on 1ft section of the port main exhaust.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 January 2017
Resolved 20 January 2017
Resolution: Lagging replaced.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 19 January 2017 Resolved
Wrong call sign on FCC Bridge to bridge and safety cert.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 January 2017
Resolution: Corrected call sign on FCC Bridge to bridge and safety cert.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 2 February 2016 Resolved
Provide protective guards for jacket water and stbd fuel storage tank sight glass.
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 2 February 2016
Resolution: Vessel rep provided proper guards for sight glass prior to completion of inspection.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 2 February 2016 Resolved
Replaced Life floats and Life Ring water activated lights with approved 6V batteries.
Action required: 705 - Other - as specified
Due 16 February 2016
Resolved 2 February 2016
Resolution: Vessel rep provided approved 6V battery prior to the completion of inspection.
Engineering › Fuel Oil Service System › Gauge
Issued 25 March 2014 Resolved
Renew sight glass gauge for lube oil and dirty oil tanks, current gauges were plastic and should be glass.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 March 2014
Engineering › Fuel Oil Service System › Hose
Issued 3 February 2012 Resolved
Port MDE leaking fuel line. Vessel shall replace prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2012
Resolution: Visually verified Port MDE fuel line replaced.
Engineering › Fuel Oil Service System › Valve
Issued 3 February 2012 Resolved
Port and Starboard MDE, valves need replacement on the RACOR filter system.
Action required: 705 - Other - as specified
Due 13 February 2012
Resolved 6 February 2012
Resolution: Visually verified RACOR valves replaced.
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 3 February 2012 Resolved
Bus Bar failed to prevent simultaneously operation. Vessel shall show proper operation of switchboard Bus Bar prior to sail.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2012
Resolution: Visually verified proper operation of switchboard Bus Bar.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 3 February 2012 Resolved
Port side engine room, fuel spicket requires plug for fire safety/pollution control.
Action required: 705 - Other - as specified
Due 13 February 2012
Resolved 6 February 2012
Resolution: Visually verified plug added to fuel spicket.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 3 February 2012 Resolved
Circuit Breaker Panel, Breaker #9 located starboard side of engine room, missing cap to prevent ingress of water.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2012
Resolution: Visually verified cap restored on Circuit Breaker Panel, Breaker #9.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 3 February 2012 Resolved
Label all control boxes.
Action required: 705 - Other - as specified
Due 13 February 2012
Resolved 6 February 2012
Resolution: Visually verified all control boxes properly labeled.
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 February 2012 Resolved
Starboard MDE, sensor needs to be rewired, located near reduction gear on the outboard side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2012
Resolution: Visually verified sensor rewired.
Electrical › Lighting (service) › Lighting Fixture
Issued 3 February 2012 Resolved
Light fixture located on starboard side of engine room, not properly secured, mounted and dangling from the overhead.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2012
Resolution: Visually verified light fixture properly mounted and secured.
Engineering › Fuel Oil Service System › Valve
Issued 3 February 2012 Resolved
Starboard MDE, fuel return valve needs to be replaced.
Action required: 705 - Other - as specified
Due 13 February 2012
Resolved 6 February 2012
Resolution: Visually verified fuel return valve replaced.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 3 February 2012 Resolved
Port SSDG, improper wiring for the overspeed controls.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2012
Resolution: Visually verified overspeed wiring on Port SSDG re-wired.
Communications › Internal Communications System › Sound-powered Telephone
Issued 7 February 2011 Resolved
Sound powered phone system not properly working. Show proper operation of SPP.
Due 7 March 2011
Resolved 16 February 2011
Resolution: SPP working properly in all spaces.
Fire Fighting › Fire Hydrants › Condition
Issued 7 February 2011 Resolved
All fire stations not properly outfitted with Spanner Wrench. Ensure each fire wrench is properly outfitted with spanner wrench.
Due 7 March 2011
Resolved 7 February 2011
Resolution: All Fire Station were properly outfitted with Spanner wrench prior to MI''''s departing vsl
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 February 2011 Resolved
A/C Disconnect control box inoperable. Repair electrical connections and properly label control box.
Due 7 March 2011
Resolved 16 February 2011
Resolution: All wires properly connected and box properly labeled.
Documentation › Logs/Records › Logbook (official)
Issued 7 February 2011 Resolved
Emergency Drills not properly logged. Ensure drills are logged and conducted IAW applicable regulations.
Due 7 February 2011
Resolved 7 February 2011
Resolution: Discussed importance of drills with crew, captain, vsl rep. Ran sat drills and discussed consequence of not properly logging emergency drills.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 7 February 2011 Resolved
Dead end cables located aft of PORT MDE. Properly secure and lable cables.
Due 7 March 2011
Resolved 16 February 2011
Resolution: Dead end cables were placed in junction box. wires properly secured and box properly labled.
Engineering › Generator (propulsion-electric) › Overcurrent Devices Circuitry
Issued 18 February 2010 Resolved
Provide service ticket for overspeeds on both generators.
Action required: 705 - Other - as specified
Due 18 March 2010
Resolved 18 February 2010
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 February 2009 Resolved
Install proper USCG approved battery charger above air receiver in E/R. Remove existing extension cord, install wiring/J box IAW sub J.
Due 2 March 2009
Resolved 10 February 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 February 2009 Resolved
Remove all dead wiring and secure loose wiring with proper supports in E/R. Properly secure MDE guage
Due 3 March 2009
Resolved 10 February 2009
Electrical › Electrical Distribution System (service) › Junction Box
Issued 2 February 2009 Resolved
Provide junction box cover for J box above air receiver.
Due 3 March 2009
Resolved 10 February 2009
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 2 February 2009 Resolved
Renew control box for air conditioner in E/R
Action required: 705 - Other - as specified
Due 3 March 2009
Resolved 10 February 2009
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 2 February 2009 Resolved
Properly install panal cover on Fwd E/R bulkhead distribution panal.
Due 3 March 2009
Resolved 3 February 2009
Electrical › Lighting (service) › Lighting Branch Circuit
Issued 2 February 2009 Resolved
Properly mount port nav light junction box.
Due 2 March 2009
Resolved 3 February 2009
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 2 February 2009 Resolved
Provide plugs for all oil tank fills in engine room.
Due 2 March 2009
Resolved 10 February 2009
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 February 2009 Resolved
Repair port E/R vent cover on main deck
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2009
Fire Fighting › Ventilation Systems › Operating Controls
Issued 2 February 2009 Resolved
Mark vent closures "close in case of fire"
Due 2 March 2009
Resolved 3 February 2009
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 2 February 2009 Resolved
Renew flame screens in day tank and #1 fuel tank vent.
Due 2 March 2009
Resolved 10 February 2009
Fire Fighting › Means of Escape › Emergency Lighting
Issued 2 February 2009 Resolved
Provide emergency light for fwd berthing area.
Due 2 March 2009
Resolved 3 February 2009
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 2 February 2009 Resolved
Renew transfer pump manifold gasket to stop excess fuel leak
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 February 2009
Navigation › Piloting/Steering › Marine Charts
Issued 20 March 2008 Resolved
Outdated.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2008
Stability › Watertight Integrity › General
Issued 20 March 2008 Resolved
All watertight door gaskets need replacement.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2008
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 20 March 2008 Resolved
Starboard MDE exhaust piping exposed and leaking.
Action required: 705 - Other - as specified
Resolved 21 March 2008
Electrical › Electric Generation Source (service) › Overcurrent Device
Issued 20 March 2008 Resolved
Not working.
Action required: 705 - Other - as specified
Resolved 21 March 2008
Lifesaving › Lifefloat › Serviceable
Issued 20 March 2008 Resolved
Worn lifelines, reflective tape and not labeled as required on life float and paddles.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2008
Lifesaving › Lifebuoys › Serviceable
Issued 20 March 2008 Resolved
Worn lines and reflective tape.
Action required: 705 - Other - as specified
Resolved 21 March 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 March 2008 Resolved
Electrical lines throughout engine room supported by multiple plastic ties.
Action required: 705 - Other - as specified
Resolved 21 March 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 5 February 2007 Resolved
Provide
Due 5 March 2007
Resolved 5 February 2007
Lifesaving › Lifefloat › Capacity
Issued 5 February 2007 Resolved
Label capacity on all lifefloats.
Due 5 March 2007
Resolved 5 February 2007
Electrical › Electric Generation Source (service) › Generator
Issued 5 February 2007 Resolved
demonstrate proper operation of stbd generator overspeed trip.
Due 5 March 2007
Resolved 5 February 2007
Lifesaving › Lifefloat › Lifeline
Issued 5 February 2007 Resolved
Provide lifeline and harness for use with the Rescue Platform.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 February 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 January 2007 Resolved
VSL IS TO DEMONSTRATE PROPER OPERATION OF ALL NAVIGATION LIGHTS PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2007
Resolved 8 January 2007
Resolution: COMPLETED
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 5 January 2007 Resolved
VSL IS TO REINSTALL MAST AND DEMONSTRATE PROPER OPERATION OF MAST LIGHT.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2007
Resolved 8 January 2007
Resolution: COMPLETED
Electrical › Lighting (service) › Lighting Fixture
Issued 5 January 2007 Resolved
INSTALL COVERS ON GALLEY RANGE HOOD LIGHT FIXTURE.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Resolution: COMPLETED
Engineering › Diesel Engine (propulsion-direct drive) › Block
Issued 5 January 2007 Resolved
REPAIR STARBOARD MAIN ENGINE FOUNDATION BRACKETS PRIOR TO SAILING.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Resolution: COMPLETED
Construction/Loadline › Structures › Door
Issued 5 January 2007 Resolved
CLOSE ALL WATER TIGHT DOORS WHILE UNDERWAY.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2007
Resolved 8 January 2007
Resolution: COMPLETED
Documentation › Markings/Placards › Oil Discharge Placard
Issued 5 January 2007 Resolved
PROVIDE OIL POLLUTION PLACARD.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Resolution: COMPLETED
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 5 January 2007 Resolved
REMOVE EXCESSIVE OIL IN BILGE PRIOR TO SAILING.
Action required: 705 - Other - as specified
Due 5 February 2007
Resolved 8 January 2007
Resolution: COMPLETED
Construction/Loadline › Penetrations › Gasket
Issued 9 March 2005 Resolved
renew WTD gaskets
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: Corrected and tested by MSU Houma
Lifesaving › Hand Flares › Not on Board
Issued 9 March 2005 Resolved
not enough on brd, those that were expired
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: Corrected
Lifesaving › Lifefloat › Float-free Link
Issued 9 March 2005 Resolved
renew link and secure paddles/ pendants
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: Corrected
Communications › Radio Communications › EPIRB
Issued 9 March 2005 Resolved
replace expired hydro release
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: Corrected
Electrical › Electric Generation Source (service) › Generator
Issued 9 March 2005 Resolved
demonstrate operation of overspeed trips and main panel meters and indicator lights
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: Corrected
Fire Fighting › Fire Pumps › Pressure
Issued 9 March 2005 Resolved
replace guage and demonstrate required pressure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: Corrected
Engineering › Compressed Air System (start air) › Valve
Issued 9 March 2005 Resolved
renew pressure-relief valves
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: Corrected
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 9 March 2005 Resolved
wrap hot exhaust pipe
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2005
Resolution: Corrected
Navigation › Collision/Grounding Avoidance
Issued 3 July 2003 Resolved
Provide (1) ball day shape. LEGACY COMPONENT DESC: Day Shapes
Action required: 705 - Other - as specified
Due 3 August 2003
Resolved 23 July 2003
Lifesaving › Buoyant Apparatus
Issued 3 July 2003 Resolved
Provide (2) additional paddles for the life floats. LEGACY COMPONENT DESC: Life Float
Action required: 17 - Rectify deficiencies prior to departure
Due 3 August 2003
Resolved 23 July 2003
Engineering › Bilge Water Management System
Issued 3 July 2003 Resolved
Label bilge manifold valves with the compartment name being serviced. LEGACY COMPONENT DESC: Manifold
Action required: 705 - Other - as specified
Due 3 August 2003
Resolved 23 July 2003
Pollution Prevention/Response › Prevention Equipment
Issued 3 July 2003 Resolved
Provide a lock for the sewage overboard discharge valve. LEGACY COMPONENT DESC: Sewage System Valve
Action required: 705 - Other - as specified
Due 3 August 2003
Resolved 23 July 2003
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 3 July 2003 Resolved
Provide proof of hydrostatic test for the fuel transfer hoses. LEGACY COMPONENT DESC: Transfer Hose
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 August 2003
Resolved 23 July 2003
Fire Fighting › Fire Pumps › Pressure
Issued 26 February 2002 Resolved
PRIOR TO VESSEL MOVEMENT DEMONSTRATE MINIMUM REQUIRED FIRE MAIN PRESSURE
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2002
Resolved 26 February 2002
Engineering › Bilge Water Management System
Issued 26 February 2002 Resolved
PRIOR TO VESSEL MOVEMENT DEMONSTRATE PROPER OPERATION OF PILOTHOUSE AND ENGINE ROOM ALARM PANELS LEGACY COMPONENT DESC: ALARMS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2002
Resolved 26 February 2002
Engineering › Bilge Water Management System
Issued 26 February 2002 Resolved
PRIOR TO VESSEL MOVEMENT PROVIDE A WRENCH FOR THE FOREPEAK REACH ROD LEGACY COMPONENT DESC: REACH ROD
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2002
Resolved 26 February 2002
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 26 February 2002 Resolved
PROVIDE AND INSTALL FLAME RESISTANT SIGHT GLASSES FOR THE FUEL OIL DAY TANKS
Condition: Improper/Lack of Maintenance
Due 26 February 2002
Resolved 26 February 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 26 February 2002 Resolved
PRIOR TO SAILING REMOVE ALL EXTRA 12 AND 24 VOLT BATTERIES LYING IN THE ENGINE ROOM. LEGACY COMPONENT DESC: HAZARDS
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2002
Resolved 26 February 2002
Construction/Loadline › Structures › Door
Issued 26 February 2002 Resolved
PRIOR TO VESSEL MOVEMENT CONDUCT MAINTENANCE ON THE ENGINE ROOM LOWER WATERTIGHT DOOR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2002
Resolved 26 February 2002
Construction/Loadline › Structures › Door
Issued 26 February 2002 Resolved
PRIOR TO SAILING REMOVE ITEMS DEFEATING ALL DOOR ADJAR LIGHTS.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 26 February 2002
Resolved 26 February 2002
Engineering › Steering Gear System › Starter
Issued 26 February 2002 Resolved
PROPERLY LABEL ALL ENGINE ROOM STEERING SYSTEM ELECTRICAL CUT-OFFS
Condition: Improper/Lack of Maintenance
Due 26 February 2002
Resolved 26 February 2002
Electrical › Electrical Distribution System (service)
Issued 26 February 2002 Resolved
REMOVE EXTENSION CORD SERVING AS PERMANENT WIRING IN THE MASTERS CABIN. LEGACY COMPONENT DESC: CORDS
Condition: Improper Installation
Due 26 February 2002
Resolved 26 February 2002
Lifesaving › Lifejacket/PFD (Type I)
Issued 26 February 2002 Resolved
PROVIDE PROPER DONNING INSTRUCTIONS FOR TYPE OF PFD'S CARRIED LEGACY COMPONENT DESC: PLACARD
Due 26 February 2002
Resolved 26 February 2002
Navigation › Piloting/Steering › Coast Guard Light List
Issued 26 February 2002 Resolved
PROVIDE UP TO DATE LIGHT LIST
Due 26 February 2002
Resolved 26 February 2002
Construction/Loadline
Issued 8 February 2000 Resolved
REPLACE MISSING DOGS ON FWD AND AFT CREW LOUNGE AREA QUICK ACTING WATERTIGHT DOORS, (QAWTDS), AND PROVE PROPER OPERATION TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 8 February 2000
Resolved 8 February 2000
Documentation
Issued 9 February 1995 Resolved
PROVIDE ON BOARD UPDATED CARGO TRANSFER PROCEDURE PER 33 CFR 155.750
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Navigation
Issued 9 February 1995 Resolved
REBUSH RUDDER STOCK AND ALL PIVOT POINTS AT NEXT DRYDOCK.
Condition: Unknown
Due 9 February 1995
Resolved 9 February 1995
Fire Fighting
Issued 16 February 1993 Resolved
1. PROVIDE APPROVED PLANS DETAILING FIREMAIN SYSTEM(S) DIAGRAM.
Condition: Unknown
Due 16 February 1993
Resolved 16 February 1993
Navigation
Issued 22 February 1991 Resolved
REPLACE THE LIGHT SOCKETS IN ALL NAV LIGHTS IF REFIT IS POSSIBLE WITH THE FIXTURE. IF REFIT IS NOT POSSIBLE TO MEET 46 CFR 11.75-17(D), ALL FIXTURE_x001C_MUST BE REPLACED.
Condition: Unknown
Due 22 February 1991
Resolved 22 February 1991

Casualty record · 2

7 April 2013Routine · role: Involved in a Marine Casualty · activity 4564738
28 April 2014Routine · role: Involved in a Marine Casualty · activity 4847747
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.