Records from 1981 to 1999. Most recent: inspection, 17 August 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 70
17 August 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1112757
16 August 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1115885
16 September 1998
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1381335
26 May 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 790775
16 May 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 122748
15 March 1998
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 794408
25 November 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 774773
8 October 1997
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431864
26 August 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 9601
28 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781003
20 May 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1098078
13 May 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 13581
14 April 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1094134
8 January 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1097014
19 September 1996
Deficiency Check · COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1355935
12 May 1995
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1355222
13 April 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1187584
22 February 1995
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1400142
14 December 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1147718
20 September 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 869833
26 July 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1171910
14 July 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1177643
22 June 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1470093
13 April 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1167725
18 August 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 847347
2 August 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 848169
23 June 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1157486
2 June 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415847
11 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 181576
11 May 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 688530
21 January 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1141501
13 November 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1139797
6 October 1992
Hull Examination · Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1140114
11 July 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 936084
19 June 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243618
13 June 1991
Deficiency Check · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1244261
5 February 1991
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1235190
22 August 1990
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 910968
3 May 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1213895
5 March 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223449
3 March 1990
Deficiency Check · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920740
29 January 1990
Drydock Extension
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 920109
4 December 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1227743
13 November 1989
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 909445
3 November 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1009544
2 August 1989
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1038984
29 June 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347095
17 May 1989
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1344929
11 October 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1194704
19 August 1988
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1347961
27 August 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1000419
16 July 1987
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1023396
13 February 1987
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1319927
20 February 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1296931
13 December 1985
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 986916
18 April 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 978895
25 January 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 975073
17 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282386
26 January 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 975597
20 January 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 975596
4 January 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971922
4 January 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 972377
3 August 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971392
12 July 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 971590
13 April 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1275499
5 October 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1274977
30 April 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 968499
19 April 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 970451
19 April 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1278358
1 October 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 969122
Construction/Loadline
Issued 8 October 1997
Resolved
F-5 VOID: CROP AND RENEW DECK INSERT FOLLOWING PROPER INSERT PROCEDURES.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 8 October 1997
Resolved
D-5 VOID: RENEW OVERHEAD STIFFENER ADJACENT TO MANHOLE.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 8 October 1997
Resolved
GAUGE OVERHEAD STIFFENERS IN A-1 VOID, FWD LEG WELL, STBD LEG WELL, AND B-4BALLAST TANK. RENEW IF WASTAGE EXCEEDS 25% IN VOIDS AND 15% IN LEG WELLS.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 8 October 1997
Resolved
RENEW MANHOLE COVERS ON VOID TANKS AND BALLAST TANKS THROUGHOUT RIG AS NECESSARY.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 8 October 1997
Resolved
CONDUCT MAT SWIM-BY INSPECTION TO SATISFACTON OF ATTENDING INSPECTOR.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Electrical
Issued 8 October 1997
Resolved
INSTALL LIFEBOAT AND LIFERAFT EMERGENCY FLOODLIGHTS THAT ILLUMINATE FROM LAUNCHING AREA TO THE WATER.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Lifesaving
Issued 8 October 1997
Resolved
PROVIDE 12 HAND HELD PARACHUTE FLARES.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 8 October 1997
Resolved
E-G VOID: PUMP OUT WATER. GAUGE OUTBOARD BKHD STIFFENERS AND RENEW IF WASTAGE EXCEEDS 25%
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Electrical
Issued 8 October 1997
Resolved
REPAIR OR REPLACE BREAKER FOR #3 S/S GENERATOR.
Condition: Unknown
Due 15 October 1997
Resolved 15 October 1997
Lifesaving
Issued 8 October 1997
Resolved
REFILL BREATHING AIR BOTTLE AND ARREST CORROSION ON BREATHING AIR HOSE FITTINGS IN LIFEBOAT #2.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Accommodation/Occupational Safety
Issued 8 October 1997
Resolved
INSTALL GENERAL ALARM BELL ON FORWARD MAIN DECK.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Engineering
Issued 8 October 1997
Resolved
REPLACE NON-METALLIC FLEXIBLE FUEL LINES ON S/S GENERATOR PRIME MOVERS WITHHARD PIPING SO THAT FLEXIBLE LINES ARE NO GREATER THAN 30 INCHES LONG.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Electrical
Issued 8 October 1997
Resolved
ADJUST OVERSPEED TRIPS FOR S/S GENERATOR PRIME MOVERS #2 AND 4.
Condition: Unknown
Due 15 October 1997
Resolved 15 October 1997
Construction/Loadline
Issued 8 October 1997
Resolved
MAKE ONE DUMP VALVE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 15 October 1997
Resolved 15 October 1997
Lifesaving
Issued 8 October 1997
Resolved
RENEW WASTED FRAMES UNDER WALKWAY OUTSIDE OF DRILL FLOOR, STARBOARD SIDE.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Documentation
Issued 8 October 1997
Resolved
PROVIDE APPROVED COPY OF OPERATIONS MANUAL ON BOARD.
Condition: Unknown
Due 5 November 1997
Resolved 5 November 1997
Accommodation/Occupational Safety
Issued 8 October 1997
Resolved
GAUGE PITTED AREAS OF RIG FLOOR AIR RECEIVER. ARREST CORROSION, MAKE REPAIRS, OR REPLACE RECEIVER AS NECESSARY. TEST RELIEF VALVE.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Electrical
Issued 8 October 1997
Resolved
CONDUCT TEST OF EMERGENCY RIG SHUT-DOWNS.
Condition: Unknown
Due 15 October 1997
Resolved 15 October 1997
Accommodation/Occupational Safety
Issued 8 October 1997
Resolved
GAUGE BULK TANKS, WITH PARTICULAR ATTENTION TO PITTED AREAS. GUAGE COLD START AIR RECEIVER.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 8 October 1997
Resolved
CONDUCT NDT EXAM OF LEG-TO-MAT CONNECTIONS TO SATISFACTION OF ATTENDING INSPECTOR. SUBMIT REPORT AND VIDEO OF EXAM TO [name withheld].
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Lifesaving
Issued 8 October 1997
Resolved
REVISE POLICY AND PROCEDURES TO MEET REQUIREMENTS OF NEW 46CFR109 (SUMMARY OF REGULATIONS RECEIVED BY JOHNNY KING, OIM).
Condition: Unknown
Due 15 October 1997
Resolved 15 October 1997
Construction/Loadline
Issued 8 October 1997
Resolved
F-1 VOID: GAUGE STIFFENERS ON AFT BULKHEAD. RENEW IF WASTAGE EXCEEDS 25%.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 8 October 1997
Resolved
G-1 VOID: REPAIR ELECTRICAL CABLE WITH BROKEN INSULATION. RENEW OVERHEAD STIFFENER FLANGE, 5TH FROM OUTBOARD IN BAYS 1 THROUGH 4.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 8 October 1997
Resolved
G-1 VOID: GOUGE AND WELD SEPERATED BUTT JOINT BETWEEN BOTTOM STIFFENERS (PERPENDICULAR MEMBERS) IN 1ST BAY STARBOARD.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Construction/Loadline
Issued 8 October 1997
Resolved
F-5 VOID: RENEW HORIZONTAL STIFFENERS ON BULKHEAD UNDER LADDER WHERE WASTAGE EXCEEDS 25%.
Condition: Unknown
Due 8 October 1997
Resolved 8 October 1997
Documentation
Issued 8 January 1997
Resolved
SUBMIT TO MSO PORT ARTHUR COPY OF FINAL ABS APPROVAL FOR MODIFICATIONS TO INCREASE VARIABLE LOADING CAPACITY BY ADDING RE-ENFORCEMENT TO BOTTOM OF FRAMES #17, 20, & 20 AND TO TRANSVERSE BULKHEADS AT FRAMES #17 & 20.
Condition: Unknown
Due 8 January 1997
Resolved 8 January 1997
Documentation
Issued 19 September 1996
Resolved
SUBMIT TO THIS OFFICE COPY OF ABS REPORT OF FINAL INSTALLATION HULL STRAPPING.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Fire Fighting
Issued 12 May 1995
Resolved
INSTALL TIME DELAY SYSTEM TO FIXED FIRE SUPPRESSION HALON SYSTEM TO SCR SPACE AS PER NFPA 12A REQUIREMENT. TO BE COMPLETED AT REACTIVATION AND PRIOR TO VESSEL LEAVING SABINE PASS.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Fire Fighting
Issued 12 May 1995
Resolved
PERFORM FIRE DRILL IN PRESENCE OF A MARINE INSPECTOR PRIOR TO COMMENCING DRILLING OPERATIONS. TO BE COMPLETED AT REACTIVATION AND PRIOR TO VESSEL LEAVING SABINE PASS.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Lifesaving
Issued 12 May 1995
Resolved
PREFORM ABANDONMENT DRILLS IN PRESENCE OF A MARINE INSPECTOR PRIOR TO COMMENCING DRILLING OPERATIONS. TO BE COMPLETED AT REACTIVATION AND PRIOR TO VESSEL LEAVING SABINE PASS.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Fire Fighting
Issued 12 May 1995
Resolved
PERFORM FUNCTIONAL TEST OF HALON SYSTEM AND PIPING TEST I.A.W. 46 CFR 108.449 OF NEWLY INSTALLED TIME DELAY SYSTEM TO SCR SPACE IN THE PRESENCE OF A MARINE INSPECTOR. TO BE COMPLETED AT REACTIVATION AND PRIOR TO VESSEL LEAVING SABINE PASS.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Fire Fighting
Issued 12 May 1995
Resolved
SUBMIT TO MSC FOR PLAN APPROVAL FIXED HALON FIRE SUPPRESSION SYSTEM FOR THESCR SPACE AND SUBMIT PLAN APPROVAL COPIES TO PATMS. TO BE COMPLETED AT REACTIVATION AND PRIOR TO VESSEL LEAVING SABINE PASS.
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Unknown
Issued 22 February 1995
Resolved
PROVIDE FINAL ABS REPORT CONCERNING MAT REPAIRS AND MAT TO LEG REPAIRS.
Condition: Unknown
Due 22 April 1995
Resolved 12 April 1995
Accommodation/Occupational Safety
Issued 26 July 1994
Resolved
MAKE PERMANENT REPAIRS OR REPLACE MARINE SANITATION DEVICE (RED FOXX UNIT) DUE TO LEAKAGE.
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Documentation
Issued 26 July 1994
Resolved
PROVIDE ON BOARD UPDATED AND APPROVED OPERATING MANUAL.
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Construction/Loadline
Issued 26 July 1994
Resolved
MAKE PERMANENT REPAIRS TO WASTED UNDERDECK STRUCTURAL MEMBERS AND WASTED PLATING IN OVERHEAD OF MUDPIT ROOM.
Condition: Unknown
Due 26 July 1994
Resolved 26 July 1994
Accommodation/Occupational Safety
Issued 22 June 1994
Resolved
REPLACE RELIEF VALVE ON POTABLE WATER TANK WITH ONE SET AT OR BELOW 100 PSI.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Accommodation/Occupational Safety
Issued 22 June 1994
Resolved
REWIRE MUDPIT ROOM VENTILATION ALARMS SO THEY ARE WIRED/WORK INDEPENDENTLY OF VENTILATION FAN MOTORS OR CONTROLLERS.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Construction/Loadline
Issued 22 June 1994
Resolved
PROVIDE REPAIR PROPOSAL FOR WASTED UNDERDECK STRUCTURAL MEMBERS IN OVERHEADOF MUDPIT ROOM. PROPOSAL SHALL INCLUDE METHOD OF REPLACEMENT, EXTENT OF REPLACEMENTS, GUAGING REPORT OF MAIN DECK IN AREAS OF WASTAGE AND TIMETABLEFOR REPAIRS.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Documentation
Issued 22 June 1994
Resolved
PROVIDE COPIES OF USCG APPROVED FIRE CONTROL PLAN, OPERATING MANUAL AND CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Electrical
Issued 22 June 1994
Resolved
PROVIDE MEANS TO SHUT-OFF FUEL OIL FROM DAY TANK TO EMERGENCY GENERATOR ENGINE FROM OUTSIDE SPACE.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Accommodation/Occupational Safety
Issued 22 June 1994
Resolved
MAKE TEMPORARY REPAIRS TO WASTED AREAS OF RED FOXX MSD UNIT WHERE LEAKING. PROVIDE PROPOSAL FOR PERMANENT REPAIRS.
Condition: Unknown
Due 29 July 1994
Resolved 29 July 1994
Electrical
Issued 2 June 1993
Resolved
TEST TOTAL RIG SHUTDOWN FROM BOTH DRILL FLOOR AND TOOL PUSHERS OFFICE.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Engineering
Issued 2 June 1993
Resolved
INSTALL SIGHT GLASS PROTECTOR ON ENGINE ROOM DAY TANK.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Construction/Loadline
Issued 2 June 1993
Resolved
TEST AND REPAIR WATERTIGHT DOORS.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Engineering
Issued 2 June 1993
Resolved
REPAIR FUEL OIL CONTAINMENT TO PORT SIDE FUEL HOSE
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Lifesaving
Issued 2 June 1993
Resolved
REPLACE OR HYDROSTATICALLY TEST (3) AIR BOTTLES IN #2 LIFEBOAT.
Condition: Unknown
Due 2 June 1993
Resolved 2 June 1993
Documentation
Issued 6 October 1992
Resolved
PROVIDE LEGIBLE COPIES OF APPROVED HAZARDOUS LOCATION PLAN ON BOARD. UPDATETO SHOW NEW SAFE WELDING AREA.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Documentation
Issued 6 October 1992
Resolved
PROVIDE COPY OF DIVER'S REPORT AND VIDEO OF UNDERWATER SURVEY TO MARINE SAFETY OFFICE NEW ORLEANS, LA.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Lifesaving
Issued 6 October 1992
Resolved
CONDUCT WEIGHT TEST OF BOTH DAVITS FOR DAVIT LAUNCHED RAFT SYSTEMS DUE TO FALLS BEING CHANGED OUT.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Lifesaving
Issued 6 October 1992
Resolved
HYDROSTATICALLY TEST LOWER AIR CYLINDER IN #1 LIFEBOAT.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Electrical
Issued 6 October 1992
Resolved
MAKE REPAIRS TO SCR SYSTEM AND PROVE THAT RIG WILL MAINTAIN POWER WHEN MASTER GENERATOR IS LOST. TEST TO BE CONDUCTED IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 16 December 1992
Resolved 16 December 1992
Lifesaving
Issued 13 June 1991
Resolved
REPAIR THE FOLLOWING GENERAL ALARM BELLS: 1) OUTSIDE TOOL PUSHER'S OFFICE,2) NEXT TO DRILL WATER VENT E-3, 3) SHALE SHAKER, 4) MUD PIT ROOM, AND 5) PORT SIDE EXT. OF HOUSE.
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Navigation
Issued 13 June 1991
Resolved
REPLACE PORT AND STARBOARD RUNNING LIGHTS
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Lifesaving
Issued 13 June 1991
Resolved
REPAIR AIR SUPPLY CONNECTIONS AND HOSES TO PREVENT LEAKING IN #1 LIFEBOAT.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Lifesaving
Issued 13 June 1991
Resolved
SERVICE #4 LIFERAFT._x001C_
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Lifesaving
Issued 13 June 1991
Resolved
INSTALL CHECKVALVE MODIFICATION KIT FOR #1 AND #2 LIFEBOATS TO PREVENT EXHAUST SMOKE FROM ENTERING LIFEBOATS.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Documentation
Issued 13 June 1991
Resolved
PROVIDE APPROVED CONSTRUCTION PORTFOLIO FOR RIG.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Fire Fighting
Issued 13 June 1991
Resolved
REPLACE WASTED ELBOW IN FIRE MAIN ATR #12 FIRE STATION ON DRILL FLOOR. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Lifesaving
Issued 13 June 1991
Resolved
RE-ADJUST DOGS AND/OR RENEW GASKETS AROUND HATCHES AND WINDOWS IN #1 AND #2LIFEBOATS TO PREVENT LEAKING WHEN OPERATING SPRINKLER SYSTEM.
Condition: Unknown
Due 13 June 1991
Resolved 13 June 1991
Construction/Loadline
Issued 5 March 1990
Resolved
REPAIR FIRE DAMPER VENTILATION SHUT DOWN ON PAINT LOCKER.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Electrical
Issued 5 March 1990
Resolved
PROVIDE A WRITTEN PROPOSAL TO COMPLETE THE ELECTRIC INSTALLATION WORK LIST ISSUED FOR THE HAZARDOUS LOCATION.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Electrical
Issued 5 March 1990
Resolved
REPLACE KICK PIPES ON ELECTRICAL THROUGH DECK FITTINGS AS NECESSARY THROUGHOUT VESSEL.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Deck/Cargo
Issued 5 March 1990
Resolved
REPAIR OR REPLACE FUEL FITTING HOSE ON STBD. CRANE.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Fire Fighting
Issued 5 March 1990
Resolved
REPAIR OR REPLACE BRACKETS FOR PORTABLE FIRE EXTINGUISHERS STATIONS NO. 38 AND 42.]
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Deck/Cargo
Issued 5 March 1990
Resolved
INSTALL HANDRAILS IN THE ENGIN ROOM ON THE OUT BOARD SIDE OF THE CAT WALK. 33CFR 140.
Condition: Unknown
Due 5 March 1990
Resolved 5 March 1990
Construction/Loadline
Issued 29 January 1990
Resolved
GAUGE SIDE SHELL IN TANK B-5 PER 46 USC 3306
Condition: Unknown
Due 29 January 1990
Resolved 29 January 1990
Lifesaving
Issued 29 January 1990
Resolved
PROVE PROPER OPERATION OF THE INFLATION LANYARDS FOR THE DAVIT LAUNCHED LIFERAFTS. PROPER MARK AND COLOR CODE ALL REQUIRED OPERATORS ON THE DAVIT,REPAIR BRAKE HOUSING ON STBD DAVIT.
Condition: Unknown
Due 29 January 1990
Resolved 29 January 1990
Construction/Loadline
Issued 29 January 1990
Resolved
REPLACE DETERIORATED BOLTS IN/ON MAIN SEA CHEST VALVE AND STRAINER FLANGES PER 46 USC 3306.
Condition: Unknown
Due 29 January 1990
Resolved 29 January 1990
Construction/Loadline
Issued 29 January 1990
Resolved
MAKE OPERATIONAL OF REPAIR THE FOLLOWING WTD'S: SCR TO ENG RM, MUD PUMP TO SCR, HALIBURTON TO WORKSHOP (QAWTD), MUD PUMP TO MUD PIT (GASKET), SACK ROMM TO MUD PPIUT(HOLE IN KNIFE EDGE), MAIN DECK TO HYDRAULIC PUMP ROOM (WASTED KNIFE EDGE), MUD PUMP TO SCR (STEELPIN, DOOR NOT ALIGNED)
Condition: Unknown
Due 29 January 1990
Resolved 29 January 1990
Electrical
Issued 29 June 1989
Resolved
DEMONSTRATE PROPER OPERATION OF THE OVERSPEED PROTECTION ON THE #3 SHIP SERVICE GENERATOR IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Lifesaving
Issued 29 June 1989
Resolved
PROVIDE ONBOARD A SECOND HOOK FOR THE DAVIT LAUNCHED LIFERAFT ONBOARD OR PROVIDE VALID FACTORY INSPECTION/TEST CERTIFICATE TO THE COGNIZANT OCMI
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Electrical
Issued 29 June 1989
Resolved
DEMONSTRATE PROPER OPERATION OF THE #2 REVERSE POWER RELAY IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 29 June 1989
Resolved 29 June 1989
Lifesaving
Issued 11 October 1988
Resolved
PROVIDE EVIDENCE OF INSTALLATION AND PROPER OPERATION AND TESTING OF EMERGENCY LIGHTING FOR LIFEBOAT EMBARKATION LOCATIONS.
Condition: Unknown
Due 11 October 1988
Resolved 11 October 1988
Electrical
Issued 19 August 1988
Resolved
DEMONSTRATE ALARM FOR LOSS OF VENTILATION TO MUD PIT ROOM, IAW 46 CFR 108.185(C)(2).
Condition: Unknown
Due 19 August 1988
Resolved 19 August 1988
Construction/Loadline
Issued 16 July 1987
Resolved
MAKE PERMANENT REPAIR TO INDICATION IN THE PORT STERN COLUMN (C-2) AT THE PORT SIDE OF THE FORWARD RACK.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Unknown
Issued 16 July 1987
Resolved
REPAIR OR REPLACE AND LABEL THE WASTED VENTILATION PANEL BOX 4B.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Fire Fighting
Issued 16 July 1987
Resolved
TEST THE PORT FIRE PUMP.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Engineering
Issued 16 July 1987
Resolved
TEST THE REMOTE SHUTDOWN AND THE HALON SHUTDOWN OF THE GENERATOR ENGINES.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Unknown
Issued 16 July 1987
Resolved
INSTALL A GENERAL ALARM CONTACT MAKER APPROVED FOR HAZARDOUS LOCATIONS.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Construction/Loadline
Issued 16 July 1987
Resolved
COMPLETE THE UNDERWATER PORTION OF THE DRYDOCK.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Electrical
Issued 16 July 1987
Resolved
REPAIR OR REMOVE FROM THE HAZARDOUS LOCATION THE BATERY CHARGER CRACKED GLASS, AFT BHD DRILL FLOOR.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Construction/Loadline
Issued 16 July 1987
Resolved
INSTALL BOLTS TO MAN HOLE COVER AT STARBOARD STERN LEG.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Electrical
Issued 16 July 1987
Resolved
REPAIR THE ELECTRICAL CONNECTION TO THE STARBOARD LIFE CAPSULE CONTROL BOX.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Lifesaving
Issued 16 July 1987
Resolved
EXERCISE BOTH LIFE CAPSULES IN THE WATER; I.E. FORE AND AFT PROPULSION, FULL STARBOARD AND PORT RUDDER MOVEMENT.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Lifesaving
Issued 16 July 1987
Resolved
PROVIDE A HAND CRANK FOR THE STARBOARD LIFE CAPSULE WINCH.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Lifesaving
Issued 16 July 1987
Resolved
CONDUCT A FIRE AND BOAT DRILL AND RELEASE BOTH BOATS IN THE PRESENCE OF A CVOAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Unknown
Issued 16 July 1987
Resolved
PROVE OPERATION OF THE FUEL OIL SHUTDOWN REACH RODS FROM A READILY ACCESSIBLE LOCAITON.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Unknown
Issued 16 July 1987
Resolved
CONDUCT AN INTERNAL EXAM OR HYDROSTATICALLY TEST THE AIR RECEIVER IN THE MUD PUMP ROOM.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Unknown
Issued 16 July 1987
Resolved
TEST THE PURGE AIR SYSTEM ON THE DRILL FLOOR PRIOR TO DRILLING OPERATIONS.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Construction/Loadline
Issued 16 July 1987
Resolved
MAKE PERMANENT REPAIR TO INDICATION IN THE BOW COLUMN (C-1) AT THE FRONT SIDE OF THE PORT RACK.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Electrical
Issued 16 July 1987
Resolved
REPAIR AND/OR INSTALL EMERGENCY LIGHTING IN THE FOLLOWING LOCATIONS: WATERTIGHT DOOR TO ELECTRICIAN'S SHOP FROM COMPRESSOR ROOM, THE MUD PIT ROOM (WHICH IS TO BE APPROVED/MEET HAZARDOUS LOCATION SPACE), AND THE GENERATOR ROOM.
Condition: Unknown
Due 16 July 1987
Resolved 16 July 1987
Unknown
Issued 13 December 1985
Resolved
INSTALL CORRECT LENS ON PORT BOW OBSTRUCTION LIGHT.
Condition: Unknown
Due 13 December 1985
Resolved 13 December 1985
Lifesaving
Issued 13 December 1985
Resolved
INSTALL SPACER BARS ON BOTH SMOKE SIGNAL BRACKETS AT LIFEBOAT STATIONS.
Condition: Unknown
Due 13 December 1985
Resolved 13 December 1985
Navigation
Issued 13 December 1985
Resolved
INSTALL CORRECT BULBS IN RUNNING LIGHTS(3 1/8 FUCAL HT.)
Condition: Unknown
Due 13 December 1985
Resolved 13 December 1985
Documentation
Issued 13 December 1985
Resolved
OBTAIN STABILITY LETTER DATED 27FEB85 AND PLACE ABOARD THE RIG.
Condition: Unknown
Due 13 December 1985
Resolved 13 December 1985
Accommodation/Occupational Safety
Issued 13 December 1985
Resolved
CONDUCT INTERNAL EXAM OR HYDROSTATICALLY TEST 3 AIR RECEIVERS AND 6 BULK CHEMICAL HANDLING PRESSURE VESSELS.
Condition: Unknown
Due 13 December 1985
Resolved 13 December 1985
Deck/Cargo
Issued 13 December 1985
Resolved
TEST MUD PUMP RELIEF VALVES.
Condition: Unknown
Due 13 December 1985
Resolved 13 December 1985
Documentation
Issued 13 December 1985
Resolved
PROVIDE COPIES OF USCG/ABS APPROVED PLANS FOR THE CONVERSION OF VOID SPACESD7 & D8 TO SERVICE AREAS.
Condition: Unknown
Due 13 December 1985
Resolved 13 December 1985
Documentation
Issued 13 December 1985
Resolved
PROVIDE PROOF OF ACCEPTABLE ABS INSTALLATION WEIGHT TEST ON BOTH CRANES.
Condition: Unknown
Due 13 December 1985
Resolved 13 December 1985
Electrical
Issued 25 January 1985
Resolved
REPAIR THE AIR PURGE ALARM ON THE SCR CONSOLE ON THE RIG FLOOR.
Condition: Unknown
Due 25 January 1985
Resolved 25 January 1985
Accommodation/Occupational Safety
Issued 25 January 1985
Resolved
TEST THE THREE (3) RIG AIR RECEIVER RELIEF VALVES WHEN RIG OPERATING CONDI-TIONS ALLOW FOR A SHUTDOWN OF THE COMPRESSED AIR SYSTEM.
Condition: Unknown
Due 25 January 1985
Resolved 25 January 1985
Fire Fighting
Issued 25 January 1985
Resolved
REPAIR THE HALON SYSTEM REMOTE OPERATING STATIONS.
Condition: Unknown
Due 25 January 1985
Resolved 25 January 1985
Unknown
Issued 25 January 1985
Resolved
INSTALL NON-CONDUCTING HANDRAILS ON THE FRONT OF ALL SWITCHBOARDS.
Condition: Unknown
Due 25 January 1985
Resolved 25 January 1985
Documentation
Issued 25 January 1985
Resolved
DESIGNATE THE MASTER IN WRITING.
Condition: Unknown
Due 25 January 1985
Resolved 25 January 1985
Accommodation/Occupational Safety
Issued 25 January 1985
Resolved
REPAIR THE DAMAGED HAND RAILING ON THE STARBOARD AFTER CORNER ON THE MAIN DECK.
Condition: Unknown
Due 25 January 1985
Resolved 25 January 1985
Navigation
Issued 25 January 1985
Resolved
REPLACE THE BROKEN COVER ON THE FORWARD PORT OBSTRUCTION LIGHT.
Condition: Unknown
Due 25 January 1985
Resolved 25 January 1985
Lifesaving
Issued 25 January 1985
Resolved
PROVIDE EIGHT (8) ADDITIONAL PFD'S WITH REFLECTIVE TAPE AND LIGHTS FOR A TOTAL OF 73. THE NUMBER OF PERSONS ALLOWED ON BOARD IS LIMITED TO 52 UNTILTHIS ITEM IS COMPLETED.
Condition: Unknown
Due 25 January 1985
Resolved 25 January 1985
Deck/Cargo
Issued 20 January 1984
Resolved
MAKE PERMANENT REPAIRS TO # E-3 DRILL WATER TANK.
Condition: Unknown
Due 3 February 1984
Resolved 20 January 1984
Electrical
Issued 4 January 1984
Resolved
REPLACE MISSING BREAKER PANEL BLANKS WHERE REQUIRED ON WORKLIST.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Accommodation/Occupational Safety
Issued 4 January 1984
Resolved
PROVIDE ON BOARD SUITABLE LOCKERS IN BERTHING AREAS WHERE MISSING.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Lifesaving
Issued 4 January 1984
Resolved
PROVIDE WEIGHT TEST OF INFLATABLE LIFERAFT DAVITS.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Documentation
Issued 4 January 1984
Resolved
PROVIDE ON BOARD A COAST GUARD APPROVED OPERATIONS MANUAL.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Lifesaving
Issued 4 January 1984
Resolved
REPLACE MISSING EXTERIOR DOOR HANDLE ON STARBOARD CAPSULE.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Lifesaving
Issued 4 January 1984
Resolved
RENEW FRACTURED FLOORBOARD IN PORT CAPSULE.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Lifesaving
Issued 4 January 1984
Resolved
RENEW BROKEN SEAT IN PORT CAPSULE.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Lifesaving
Issued 4 January 1984
Resolved
REPLACE MISSING OR BROKEN WINDOW LATCHES ON BOTH CAPSULES.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Lifesaving
Issued 4 January 1984
Resolved
EFFECT PERMANENT REPAIRS TO SPRINKLER SYSTEM IN WAY OF TEMPORARY REPAIR IN THE PORT BOAT.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Unknown
Issued 4 January 1984
Resolved
TEST MUD PUMP SAFETY RELIEFS IN PRESENCE OF MARINE INSPECTOR.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Fire Fighting
Issued 4 January 1984
Resolved
PROVIDE SUITABLE HANGERS FOR FIXED FOAM PIPING SYSTEM.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Lifesaving
Issued 4 January 1984
Resolved
RENEW AS NECESSARY, GRABLINES ON LIFEBOATS, BENT OR MISSING FOOT RAILS AND KEEL COOLER OF PORT BOAT IF OPERATIONS INDICATE EXCESS RESTRICTION.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Lifesaving
Issued 4 January 1984
Resolved
EFFECT PERMANENT REPAIRS TO THE SPRINKLER SYSTEMS PUMP IN BOTH SURVIVAL CAPSULS.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Electrical
Issued 4 January 1984
Resolved
PROVIDE ON BOARD AN APPROVED GENERAL ALARM SYSTEM
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Navigation
Issued 13 April 1983
Resolved
RENEW DAMAGED OBSTRUCTION LIGHT ON THE AFT STARBOARD CORNER OF THE MAINDECK
Condition: Unknown
Due 13 April 1983
Resolved 13 April 1983
Construction/Loadline
Issued 13 April 1983
Resolved
RENEW OR REPAIR THE MUDPIT ROOM DOOR CLOSURES SO AS TO MAKE THE DOORS SELF CLOSING.
Condition: Unknown
Due 13 April 1983
Resolved 13 April 1983
Electrical
Issued 13 April 1983
Resolved
PROPERLY SEAL CABLE PENETRATIONS IN WATER TIGHT BULKHEADS BELOW THE MAIN DECK.
Condition: Unknown
Due 13 April 1983
Resolved 13 April 1983
Electrical
Issued 13 April 1983
Resolved
INSURE THAT ALL PORTABLE ELECTRIC WIRING TO TEMPORARILY INSTALLED LOGGING EQUIPMENT IS IN ACCORDANCE WITH 46 CFR 111.60-5.
Condition: Unknown
Due 13 April 1983
Resolved 13 April 1983
Construction/Loadline
Issued 13 April 1983
Resolved
RENEW OR REPAIR THE WATERTIGHT DOOR FRAME BETWEEN THE HALLIBURTON ROOM AND THE REDFOX ROOM.
Condition: Unknown
Due 13 April 1983
Resolved 13 April 1983
Lifesaving
Issued 1 October 1981
Resolved
PROVIDE ANNUAL SERVICING FOR DAVIT LAUNCHED INFLATABLE LIFERAFTS.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Fire Fighting
Issued 1 October 1981
Resolved
PROVIDE AN ADDITIONAL C-II FIRE EXTINGUISHER IN THE MUD PUMP ROOM.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Unknown
Issued 1 October 1981
Resolved
AIR PURGE DRILLERS CONSOLE.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Electrical
Issued 1 October 1981
Resolved
RENEW END GUARD ON BRAKE COOLING PUMP
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Electrical
Issued 1 October 1981
Resolved
RENEW MISSING FASTENERS FOR ELECTRICAL PANEL ON AFTER BULKHEAD ON DRILL FLOOR.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Electrical
Issued 1 October 1981
Resolved
REMOVE CARDBOARD BOXES FROM ELECTRICAL CABLE TRAY IN GENERATOR ROOM.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Construction/Loadline
Issued 1 October 1981
Resolved
RENEW VENT SCREENS AS NECESSARY THROUGHOUT VESSEL.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Fire Fighting
Issued 1 October 1981
Resolved
PROVIDE AN ADDITIONAL C-II FIRE EXTINGUISHER IN HYDRAULIC PUMP ROOM.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Electrical
Issued 1 October 1981
Resolved
SEAL ALL ELECTRICAL EY FITTINGS IN CLASSIFIED LOCATIONS.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Electrical
Issued 1 October 1981
Resolved
SECURE PROPERLY ALL LOOSE JUNCTION BOXES.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Electrical
Issued 1 October 1981
Resolved
SECURE LOOSE WIRING THROUGHOUT VESSEL.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Electrical
Issued 1 October 1981
Resolved
RENEW LIGHT-TUBE COVER IN MUD-PIT ROOM.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Accommodation/Occupational Safety
Issued 1 October 1981
Resolved
RENEW MISSING OR DAMAGED HANDRAILING AS REQUIRED.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Fire Fighting
Issued 1 October 1981
Resolved
PROVIDE A C-II FIRE EXTINGUISHER ON THE MAIN DECK IN THE VICINITY OF THE SHALESHAKER.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Lifesaving
Issued 1 October 1981
Resolved
RENEW ALL DAMAGED LIFERINGS AND LIFERING LINES.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Documentation
Issued 1 October 1981
Resolved
PROVIDE ON BOARD A VALID MARINE DOCUMENT.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Documentation
Issued 1 October 1981
Resolved
PROVIDE ON BOARD A VALID LOADLINE CERTIFICATE.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Construction/Loadline
Issued 1 October 1981
Resolved
DRY DOCK VESSEL DURING NEXT RIG MOVE BUT NOT LATER THAN 01OCT82.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Unknown
Issued 1 October 1981
Resolved
WELD DRAINAGE PIPE PENETRATIONS PIERCING WATERTIGHT BULKHEAD IN MUDPIT ROOM.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981
Electrical
Issued 1 October 1981
Resolved
RENEW GUARD OVER EXPOSED SHAFT OF PUMP BELOW SHALE SHAKER.
Condition: Unknown
Due 1 October 1981
Resolved 1 October 1981