MAURY USCG vessel records Sign in
← All vessels

DAUNTLESS

DAUNTLESS is a 1981 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1981, most recently in April 2026, along with 75 deficiencies, 2 operational controls and 1 casualty investigation in 2009.

Records from 1981 to 2026. Most recent: inspection, 9 April 2026.

Built
1981
Last inspected
9 April 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDP2672
Flag
UNITED STATES
368338510
Maury page id
psix-52876

Inspections, by type

…with no type recorded19
Years with a record 43 calendar years (1981–2026)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)100.5 ft × 24.6 ft × 3.4 ft
Registered tonnagegross 91 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSWIFTSHIPS INC · MORGAN CITY, LA, UNITED STATES · built 1981
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMORGAN CITY, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP2672MMSI 368338510 · active · voluntarily equipped · granted 19 October 2023, expires 19 October 2033
WDG9446MMSI 366818680 · expired · compulsorily equipped · granted 22 August 2013, cancelled 28 October 2023
WDA5302MMSI 366818680 · cancelled · compulsorily equipped · granted 9 July 2011, cancelled 19 August 2013
WCX4256MMSI not assigned · cancelled · voluntarily equipped · granted 25 April 1997, cancelled 9 April 2001 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 79

9 April 2026 Vessel Attendance
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8345406
16 January 2026 Annual Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8297529
23 January 2025 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8069025
21 June 2024 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7939337
19 January 2024 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7877960
23 October 2023 Deficiency Check · COI Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7813493
4 November 2022 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7585065
29 August 2022 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7546245
5 July 2022 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7524082
19 August 2021 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7291354
13 May 2021 Deficiency Check · DAPI Audit · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7196444
7 February 2021 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7149615
4 September 2020 Annual Inspection · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7050253
20 August 2019 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6789143
16 July 2018 Examination of Repairs · Administrative Inspection · COI Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6481690
10 July 2017 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6204597
23 June 2017 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6184420
16 June 2017 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6181263
14 June 2016 Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5902417
11 May 2016 Drydock Exam · Hull Examination · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5874678
29 September 2015 Deficiency Check
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5724405
18 August 2015 Internal Structural Exam · Periodic Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 5213847
19 June 2014 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4951776
27 May 2014 Drydock Exam · Internal Structural Exam · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4864644
21 May 2012 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4317341
11 May 2012 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4308451
25 August 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4125754
3 April 2008 Administrative Inspection · Examination of Repairs · Re-Inspection · Deficiency Check · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3176706
29 February 2008 Damage Survey · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3158890
13 February 2008 In-Service Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3147018
13 February 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3147035
31 May 2007 Examination of Repairs
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2947328
26 May 2007 Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2940927
17 May 2007 Permit to Proceed · Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2925259
15 June 2006 Internal Structural Exam · Hull Examination · Examination of Repairs · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2693538
17 August 2005 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2465228
21 June 2004 Hull Examination · Examination of Repairs · Internal Structural Exam · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2105850
8 October 2003 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1924192
24 September 2003 Deficiency Check
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1912121
22 August 2003 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1883811
17 May 2002 COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1618014
5 April 2001 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447081
18 August 2000 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1379175
14 July 2000 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1417100
12 May 1999 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1131278
23 June 1998 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1418378
10 December 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 779327
24 July 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 781115
24 July 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 786280
15 November 1996 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 865998
4 June 1996 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456380
18 May 1995 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 871692
26 May 1994 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1179497
26 May 1994 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1455170
2 December 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1158502
25 May 1993 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 832537
28 May 1992 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473317
29 January 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 680576
26 November 1991 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1470856
26 June 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1194341
23 August 1990 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 919762
31 July 1990 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 926510
7 June 1990 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1225060
6 December 1989 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240839
22 June 1989 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1199402
17 June 1988 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 893517
18 June 1987 COI Inspection
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1336444
8 May 1987 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1020445
23 April 1987 Hull Examination
Physical examination · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1008383
11 December 1986 Type not recorded
No type recorded · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1025014
4 December 1986 Administrative
Administrative · MSO DULUTH · USCG Great Lakes District (CGD-GL) · Activity 1021857
26 February 1986 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310501
26 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289315
25 February 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1289422
16 April 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1281378
16 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971335
17 February 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1276627
11 March 1982 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278152
18 March 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274167

Deficiency record · 75

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 April 2026 Resolved
Exhaust gas must not leak from the piping or any connections. Vessel observed to have exhaust leak on port engine fitted with temporary repair. Vessel shall perform permanent exhaust repair prior to completion of next dry dock credit scheduled for June 2026. 46 CFR 182.430(b)
Action required: 705 - Other - as specified
Due 30 September 2026
Resolved 7 August 2026
Resolution: Exhaust can rebuilt.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 9 April 2026 Resolved
On a vessel of more than 65 feet, the public address system must be a fixed installation and be audible during normal operating conditions throughout the accommodation spaces and other spaces normally manned by crew members. Vessel observed to have no functional public address speaker in the upper accommodation space. Vessel restricted from the carriage of passengers in the upper accommodation area until a functional public address speaker is installed.184.610(a)
Action required: 705 - Other - as specified
Due 30 September 2026
Resolved 13 April 2026
Resolution: Video evidence of functional public address speaker from upper accommodation area submitted.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 January 2026 Resolved
An inflatable liferaft must be serviced at a facility specifically approved by the Commandant meeting the requirements of part 160, subpart 160.151 of this chapter. Vessel liferaft servicing was expired. Vessel limited to operation within 3nm of shore. 46 CFR 185.730
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2026
Resolved 13 February 2026
Resolution: New life rafts observed to be installed properly.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 January 2026 Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] team observed unapproved hull plate renewal located to the port side of the rudder room hatch. Plate insert does not cover frame space. Vessel shall complete plate renewal prior to completion of next dry dock of July 2026.
Action required: 705 - Other - as specified
Due 30 November 2026
Resolved 7 August 2026
Resolution: Vessel completed repairs in dry dock 2026 at Lighthouse Marine in Bolivar, TX
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 October 2023 Resolved
Repairs or alterations to the hull that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel conducted hull repairs at Seacraft Shipyard while on dry-dock without OCMI approval or prior notification. Provide list of all hull repairs conducted and conduct satisfactory non-destructive testing of repairs/alterations int he presence of a marine inspector prior to carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 31 October 2023
Resolution: Observed completed inserts and satisfactory NDT of repairs conducted in shipyard.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 4 November 2022 Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float-free link is not required if the vessel operates only on waters not as deep as the length of the painter; stowed so that when the vessel sinks the survival craft floats free and, if inflatable, inflates automatically. Port and starboard liferafts' painters were not connected to the float-free link. 46 CFR 185.700 Part 185 applicable to Old-T
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2022
Resolved 4 November 2022
Resolution: Corrected on the spot.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 November 2022 Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. Ring life buoy light batter was expired 07/16. Vessel is restricted to daylight operations only. 46 CFR 185.726(d) applicable to Old-T.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 November 2022
Resolved 10 November 2022
Resolution: Battery replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 November 2022 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments, under all practical conditions. Crew was unable to demonstrate proper operation of the bilge pumping system from the lazarette. 46 CFR 182.25-1(a) Old-T
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 November 2022
Resolved 10 November 2022
Resolution: Bilge operation demonstrated.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 4 November 2022 Resolved
At each inspection for certification and reinspection the marine inspector shall examine the bilges and other spaces to see that there is no accumulation of oil or other spaces to see that there is no accumulation of oil or other matter which might create a fire hazard. M/E room at the centerline M/E bilge had accumulated oil and indicated a fuel oil leak. 46 176.25-50(b) Old-T
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2022
Resolved 10 November 2022
Resolution: Leak repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 4 November 2022 Resolved
Vessels shall be inspected for compliance with the standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. The safety valve hand relieving gear pin on the starboard air receiver was missing and needs to be replaced. 46 CFR 176.25-1(a) Old-T
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2022
Resolved 10 November 2022
Resolution: Pin replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2022 Resolved
Accessories, such as switches, fuses, and sockets shall be Standard National Electrical Code types for the loads to be carried and shall be of type listed by, or types equal to those listed by Underwriter's Laboratories, Inc or other recognized testing laboratory. Junction box in the generator room and M/E CL bilge alarm cover was off. 46 CFR 183.05-35 Old-T
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2022
Resolved 10 November 2022
Resolution: Junction boxes repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 November 2022 Resolved
Vessels shall be inspected for compliance with the standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Wiring under the bridge console was left unmaintained. 46 CFR 176.25-1(a) Old-T
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2022
Resolved 10 November 2022
Resolution: Wiring repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 4 November 2022 Resolved
The manufacturer's instruction for onboard maintenance of survival craft must be onboard and readily available at each inspection. The owner or managing operator shall make sure that maintenance is carried out in accordance with the instructions under 46 CFR 185.702(a). 46 CFR 185.702 applicable to Old-T.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 December 2022
Resolved 10 November 2022
Resolution: Maintenance log established.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2021 Resolved
Propulsion machinery shall be suitable in type and design for propulsion requirements and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Starboard main diesel engine is leaking excessive amount of oil from main seal. Reapir must be made to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 13 June 2021
Resolved 27 May 2021
Resolution: New main seal inst.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 May 2021 Resolved
he engine cooling water system shall be in accordance with the following provisions: the engine head, block and exhaust manifold shall be water jacketed and cooled by water from a pump. Starboard main diesel engine heat exchanger has temporary patch to prevent leaks. Permanent repair must be made to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 13 June 2021
Resolved 27 May 2021
Resolution: New heat exchanger was inst.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 13 May 2021 Resolved
At every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Bilge has excessive amount of oil that creates a fire hazard or may clog bilge pumping systems. Bilge must be cleaned following engine repair to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 13 June 2021
Resolved 27 May 2021
Resolution: Bilge was emptied and cleaned.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 May 2021 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. Starboard generator has excessive oil leak that must be repaired to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 13 June 2021
Resolved 27 May 2021
Resolution: Upper seal inst.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 13 May 2021 Resolved
Rails shall be installed near the periphery of all weather decks accessible to passengers and crews. Port stern railing is sheared and requires repair to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 30 - Ship detained
Due 13 June 2021
Resolved 27 May 2021
Resolution: New railing inst.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 13 May 2021 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. Engine room bulkhead has approx. 12-inch crack on the starboard quarter underneath the bulwark. Crack must be repaired to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 30 - Ship detained
Due 13 June 2021
Resolved 27 May 2021
Resolution: Crack repaired and tested.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 13 May 2021 Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part and, when applicable, the duties listed in the station bill required by § 185.514 of this part. Vessel has not completed drills since December 2020. Drills must be conducted to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 13 June 2021
Resolved 27 May 2021
Resolution: Drills conducted.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 13 May 2021 Resolved
A vessel must comply with the applicable requirements for any radio installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessels operated beyond the 20 nautical mile but not more than 200 nautical miles from the nearest land, must be equipped with a MF-DSC frequency, in addition to the other requirements under 47 CFR part 80. Vessel is not equipped with MF-DSC radio. Vessel is restricted from operating past 20 nautical miles until MF-DSC radio or equivalent is installed.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 27 May 2021
Resolution: Verified SSB has MF freq.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage
Issued 13 May 2021 Resolved
The master or person in charge of a ship to which this section applies shall ensure that a written record is maintained on the ship for discharge to a reception facility or to another ship; (2) Incineration on the ship; (3) Discharge into the sea; and/or (4) Accidental or other exceptional discharges. Garbage log has not been updated since 2018. Log must be updated and completed to the satisfaction of the attending marine inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 June 2021
Resolved 27 May 2021
Resolution: Garbage log not req.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 May 2021 Resolved
Vessel given over 100 days to provide 5 years of records for crew working in safety sensitive positions / drug and alcohol records and was unable to do so.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 August 2021
Resolved 31 August 2021
Resolution: Ship owners representative stated to issue a civil penalty for the deficiency as company unable to produce the records required.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2018 Resolved
When flexible section is a nonconductor of electricity, the metallic sections of the fill pipe separated thereby must be joined by a conductor for protection against generation of a static charge when filling with fuel. There was no grounding straps on the fuel fill pipes. Connected together by rubber hose.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 22 August 2018
Resolved 22 August 2018
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 August 2018 Resolved
A Vessel must be provided with a satisfactory arrangement for draining any watertight compartment. The bilge suction piping was holed.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 22 August 2018
Resolved 22 August 2018
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 August 2018 Resolved
A vessel must be fitted with ground tackle necessary for the vessel to safely anchored. Hardware was not available to connect anchor line to the anchor.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 22 August 2018
Resolved 22 August 2018
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 July 2018 Resolved
Vessel is past due for dry-dock and internal structure exam dates on its COI. Vessel must conduct dry-dock and internal structure exam prior to movement of vessel.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 15 August 2018
Resolved 16 August 2018
Resolution: Completed drydock.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 26 June 2017 Resolved
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 July 2017
Resolved 29 June 2017
Lifesaving › Lifejacket/PFD (Type III) › Retroreflective Material
Issued 26 June 2017 Resolved
Impropper Retroreflective Material
Condition: Improper Installation
Due 27 July 2017
Resolved 28 June 2017
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 26 June 2017 Resolved
Crack in WTBLKHD in main steering room STBD INBD longitudinal.
Condition: Damaged By Earlier Event
Due 27 July 2017
Resolved 29 June 2017
Documentation › Certificates/Documents › Certificate of Inspection
Issued 16 June 2017 Resolved
Vessel was operating without a valid Certificate of Inspection.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 21 September 2017
Resolution: Obtained COI matter referred to Enforcement.
Operations/Management › Vessel Activity › Underway
Issued 16 June 2017 Resolved
Operating the vessel with an expired Certificate of Inspection.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 June 2017
Resolved 26 June 2017
Resolution: Sector Morgan City completed inspection for certification.
Electrical › Mast › Lightning Ground
Issued 14 June 2016 Resolved
Junction Box on deck aft of bridge not properly mounted.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 14 July 2016
Resolved 14 June 2016
Resolution: Junction Box on deck aft of bridge has been properly mounted.
Construction/Loadline › Structures › Door
Issued 18 August 2015 Resolved
Repair or replace fractured and warped weather-tight door at the aft of the deck house and demonstrate proper operation to the satisfaction of the attending Marine inspector.
Action required: 705 - Other - as specified
Due 18 September 2015
Resolved 29 September 2015
Resolution: Renewed weather-tight door and demonstrated proper operation to the attending Marine Inspectors.
Fire Fighting › Fire Pumps › Pressure
Issued 19 June 2014 Resolved
Fire pump gauge reading 40psi.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2014
Resolution: Gauge replaced on firepump. Fire pump met the minimum of 60psi. All Sat.
Engineering › Fuel Oil Service System › Hose
Issued 19 June 2014 Resolved
Fuel supply hose worn on center engine.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 June 2014
Resolution: Fuel supply hose replaced on center engine and chaffing gear was installed. All Sat.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 June 2014 Resolved
Plug two holes on distribution panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 July 2014
Resolved 20 June 2014
Resolution: Holes plugged on distribution panel. All Sat.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 29 April 2008 Resolved
Flammables were stowed in the machinery space and not on open deck in the paint locker.
Action required: 705 - Other - as specified
Resolved 2 May 2008
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 3 April 2008 Resolved
The base of the WTD entering the machinery space from the mess deck had loose metal that was used to hold insulation in place over the door. (Cutting Hazard)
Action required: 705 - Other - as specified
Resolved 2 May 2008
Communications › Radio Communications › EPIRB
Issued 3 April 2008 Resolved
The EPIRB was not registered.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 May 2008
Navigation › Piloting/Steering › Marine Charts
Issued 13 February 2008 Resolved
No current up to date charts available on vessel for area vessel operating in.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 February 2008
Resolved 29 April 2008
Communications › Radio Communications › VHF Radiotelephone
Issued 17 May 2007 Resolved
Conduct proper radio check on signal sideband (HF).
Action required: 705 - Other - as specified
Resolved 31 May 2007
Communications › Radio Communications › Satellite Communications Capability
Issued 17 May 2007 Resolved
Properly secure wiring to satellite radio.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 May 2007 Resolved
Secure junction box cover for lazarette bilge alarm.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Deck/Cargo › Mooring/Anchoring › Mooring Line/Hawser
Issued 17 May 2007 Resolved
Repair pinholes in hawser pipe and forepeak snorkel vents.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2007 Resolved
Update expired first aid kit consumables.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Stability › Watertight Integrity › General
Issued 17 May 2007 Resolved
Adjust ill-fitting watertight doors.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Stability › Watertight Integrity › General
Issued 17 May 2007 Resolved
Repair/replace limit switch activating arms for watertight doors.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Construction/Loadline › Hull › Weld
Issued 17 May 2007 Resolved
Repair all fractures & cracked welds in lazarette.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Engineering › Steering Gear System › Hydraulic Hose
Issued 17 May 2007 Resolved
Reattach hydraulic hoses to steering rams in lazarette.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Construction/Loadline › Hull › Hull Plating
Issued 17 May 2007 Resolved
Clean lazarette bilge areas of all dissimilar metals.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Stability › Unintentional Flooding › General
Issued 17 May 2007 Resolved
Locate/repair source of flooding in lazarette.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Engineering › Steering Gear System › Rudder
Issued 17 May 2007 Resolved
Repair/replace cracked stbd rudder arm.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 17 May 2007 Resolved
Replace gasket in exhaust flange on portside of center main engine.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Construction/Loadline › Penetrations › Weld
Issued 17 May 2007 Resolved
Inspect/repair portside exhaust at through hull penetration as needed.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Construction/Loadline › Structures › Deck Plating
Issued 17 May 2007 Resolved
Repair cracks/cuts to all engine room hatch covers, plating, and framing.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Construction/Loadline › Hull › Transverse Frame
Issued 17 May 2007 Resolved
Permanently attach all exhaust support cross members and framing.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Construction/Loadline › Hull › Weld
Issued 17 May 2007 Resolved
Repair broken welds on exhaust support cross members and framing.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Engineering › Diesel Engine (propulsion-direct drive) › Turbocharger
Issued 17 May 2007 Resolved
Securely mount main engine clutch actuators (aka 110 valves).
Action required: 705 - Other - as specified
Resolved 31 May 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 17 May 2007 Resolved
Properly secure piping on top of fuel pump.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Construction/Loadline › Hull › Transverse Frame
Issued 17 May 2007 Resolved
Repair holes in deck framing above port main engine.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 17 May 2007 Resolved
Apply hose clamps on stbd forward exhaust.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Accommodation/Occupational Safety › Occupational Safety › Smoking
Issued 17 May 2007 Resolved
Inspect/repair stbd side exhaust at flange connection for possible leaks.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Engineering › Diesel Engine (propulsion-direct drive) › Air Cleaner
Issued 17 May 2007 Resolved
Secure and apply chafing gear to air lines on all main engnes.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 17 May 2007 Resolved
Check/repair smoke detectors.
Action required: 705 - Other - as specified
Resolved 31 May 2007
Stability › Watertight Integrity › General
Issued 15 June 2006 Resolved
Several water tight doors unable to be adjusted unless the striking plates are shimmed or welded. Additionally the door handles are excessively loose requiring an excessive amount of time in securing the door. Recommend replacing these with adjustable ones.
Due 15 July 2006
Resolved 17 May 2007
Resolution: Watertight doors replaced with adjustable ones; issued another 835 for loosely-seated adjustable doors.
Engineering › Fuel Oil Service System › Valve, Control
Issued 17 August 2005 Resolved
Prove satisfactory operation of starboard fuel shut-off valve, to eliminate chaffing of rod against panel box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 September 2005
Resolved 15 June 2006
Resolution: Corrected.
Stability › Watertight Integrity
Issued 22 August 2003 Resolved
Install stuffing tube in port side bulhead IWO generator room. LEGACY COMPONENT DESC: Bulkhead
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 August 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 22 August 2003 Resolved
Install new dryer exhaust vent hose. LEGACY COMPONENT DESC: Laundry
Due 21 September 2003
Resolved 8 October 2003
Resolution: Written statement from vessels master stating that Dryer flex hose has been repair.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 22 August 2003 Resolved
Missing service tag on Paint locker portable extinguiser.
Due 22 September 2003
Resolved 29 September 2003
Resolution: Received fax report from Aqua Safety who inspected the fire extinguisher. All satisfactory.
Operations/Management › Passenger Operations
Issued 22 August 2003 Resolved
Provide Employee Assistance information, Emergency Instruction list, Passenger Safety Orientation instruction. LEGACY COMPONENT DESC: Safety Orientation
Due 22 September 2003
Resolved 12 September 2003
Resolution: Received fax copies of all required placards.
Communications › Radio Communications › Emergency Source of Power
Issued 17 May 2002 Resolved
VHF RADIO AND SSB DO NOT OPERATE UNDER EMERGENCY POWER.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2002
Resolved 17 May 2002
Navigation › Piloting/Steering › Compass Deviation Table
Issued 17 May 2002 Resolved
COMPASS DEVIATION TABLE NOT RECORDED
Due 17 May 2002
Resolved 17 May 2002
Engineering › Steering Gear System › Rudder Stock
Issued 17 May 2002 Resolved
RUDDER SHAFT PACKING BOXES NOT DOUBLE NUTTED.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2002
Resolved 17 May 2002
Construction/Loadline
Issued 7 June 1990 Resolved
PROVIDE A REACH ROD AND PROVE REMOTE OPERATION OF 1-1/4" AIR CONDITION SEA SUCTION VALVE.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990

Casualty record · 1

2 October 2009Routine · role: Involved in a Marine Casualty · activity 3610011
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CRYSTAL CLEAR (2009). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.