Records from 1981 to 2008. Most recent: inspection, 13 November 2008.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 30
13 November 2008
Examination of Repairs · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3362491
9 October 2007
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3075798
18 January 2006
Hull Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2568779
18 August 2005
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 2509905
13 November 2003
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1953482
15 September 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399453
12 October 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401091
8 October 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1375503
23 September 1997
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371986
24 September 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431679
4 January 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 670613
7 November 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213079
7 November 1995
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189898
7 November 1995
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385569
13 September 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423995
18 October 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 828062
27 September 1993
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1442064
18 November 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467827
13 September 1991
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 938757
9 November 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 917352
26 February 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1228806
15 September 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1348777
13 September 1989
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1035515
9 September 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890459
7 January 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004518
3 July 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 998352
8 May 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1316761
13 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983747
13 May 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315013
28 April 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277370
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 November 2008
Resolved
Loose/Dead end wiring to be removed from under pilot house controls
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2009
Resolved 6 March 2009
Navigation › Piloting/Steering › Marine Charts
Issued 13 November 2008
Resolved
Provide marine charts
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2009
Resolved 5 February 2009
Resolution: Provided marine charts
Engineering › Bilge Water Management System › Valve
Issued 18 August 2005
Resolved
Repair bilge suction valve leading to forepeak.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 August 2005
Resolved
Repair port and stbd NAVLTS.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Construction/Loadline › Structures › Superstructure
Issued 18 August 2005
Resolved
Repair broken window in pass accom space.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Stability › Unintentional Flooding › General
Issued 18 August 2005
Resolved
Replace gasket on scuttle leading to rudder compartment.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Engineering › Fuel Oil Service System › Hose
Issued 18 August 2005
Resolved
Prove F/O supp and ret hoses meet SAE J1942 for the intended service.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 18 August 2005
Resolved
Clean E/R bilges after removing excess oil/ fuel oil.
Action required: 705 - Other - as specified
Resolved 20 September 2005
Lifesaving
Issued 15 September 2000
Resolved
Provide copy of random drug testing program._x001C_
Condition: Unknown
Due 26 September 2000
Resolved 26 September 2000
Electrical
Issued 12 October 1999
Resolved
PROVE OPERATION OF GENERATOR VOLTAGE GAUGES IN PILOTHOUSE.
Condition: Unknown
Due 12 October 1999
Resolved 12 October 1999
Documentation
Issued 27 September 1993
Resolved
FAILURE TO HAVE CERTIFICATE OF DOCUMENTATION ON BOARD.
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993
Documentation
Issued 27 September 1993
Resolved
FAILURE TO HAVE ON BOARD VALID FCC RADIO STATION LICENSE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 27 September 1993
Resolved 27 September 1993
Documentation
Issued 13 September 1989
Resolved
NEED A VALID FCC SAFETY CERTIFICATE ONBOARD.
Condition: Unknown
Due 13 September 1989
Resolved 13 September 1989