Records from 1981 to 2007. Most recent: inspection, 5 November 2007.
Inspection history · 75
5 November 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3093334
31 October 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3093250
19 June 2007
Re-Inspection · Ballast Water Examination · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2977628
15 April 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2912785
30 May 2006
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2664054
13 May 2005
Explosive Handling Operation-Fireworks
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2366173
15 February 2005
COI Inspection · MTSA/ISPS Verification · Hull Examination · Internal Structural Exam · Examination of Repairs · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2310041
6 January 2005
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2270028
11 September 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1902816
26 August 2002
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1666677
21 August 2002
Annual Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1664285
20 August 2002
Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1663857
26 June 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1651358
6 May 2002
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1613760
2 December 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 43378
19 November 2001
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1391721
21 June 2001
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1065424
6 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 167426
6 May 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 225915
6 May 2001
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1469349
14 March 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 215598
13 March 2001
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1430996
28 February 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 104779
28 February 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 139965
28 February 2001
Damage Survey · Permit to Proceed
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1370025
24 August 2000
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1406751
2 March 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804552
11 December 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1408216
14 January 1998
Re-Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1396855
4 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 783944
4 October 1997
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1433261
3 October 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 50241
19 December 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1437188
17 April 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448758
14 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 129835
14 December 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1424178
11 December 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 40733
3 January 1995
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 654616
21 December 1994
Type not recorded
No type recorded · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 654611
20 December 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 229201
20 December 1994
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 847708
20 December 1994
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1466916
2 November 1994
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 122717
17 April 1994
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1170428
4 February 1994
Re-Inspection · Hull Examination · MARPOL Annex V Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 860153
13 October 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1133596
1 January 1993
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 159843
21 December 1992
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 830895
14 January 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 957369
7 November 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 654604
17 April 1991
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 923857
8 February 1991
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1217725
28 January 1991
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 918783
18 January 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 900843
8 March 1990
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1213822
21 February 1990
MARPOL Annex II Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 920458
22 May 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1200780
16 March 1989
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 894767
27 February 1989
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 889291
19 January 1989
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 890042
28 November 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 894828
28 November 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 895166
8 February 1988
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1327937
5 January 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1322595
1 December 1987
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028726
3 November 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326575
14 February 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1307268
3 January 1986
Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1300427
26 December 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987508
3 December 1985
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 985709
22 March 1985
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290354
30 December 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278663
13 November 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 970063
29 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 965104
27 October 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1281510
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 19 June 2007
Resolved
Place signs near galley CO2 remotes directing personnel to manual controls at CO2 system
Due 19 July 2007
Resolved 19 June 2007
Lifesaving › Lifebuoys › Stowage
Issued 19 June 2007
Resolved
Remove duct tape from life ring
Due 26 June 2007
Resolved 19 June 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 19 June 2007
Resolved
Label all breakers at panal board next to bow thruster ladder and renew box latch
Due 19 June 2007
Resolved 19 June 2007
Communications › Alarms/Indicators › General Alarm
Issued 19 June 2007
Resolved
Renew general alrm light in E/R
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2007
Engineering › Generator (propulsion-electric) › Winding
Issued 19 June 2007
Resolved
Clean both generator armatures
Due 19 July 2007
Resolved 25 July 2007
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 19 June 2007
Resolved
Place rubber mat in fromt of E/R electrical panal
Due 19 June 2007
Resolved 19 June 2007
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 19 June 2007
Resolved
Double-nut shaft packings and tighten port packing to stop excessive leak
Due 19 June 2007
Resolved 19 June 2007
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 June 2007
Resolved
Remove water from E/R battery boxes
Due 19 June 2007
Resolved 19 June 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 June 2007
Resolved
Screw down all deck plating prior to sail
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2007
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 19 June 2007
Resolved
Conduct 5 MOB drills using rescue platform and harness within the next 30 days. Submit evidence of drills to marine inspector.
Due 19 July 2007
Resolved 25 July 2007
Lifesaving › Work Vest › Approval
Issued 19 June 2007
Resolved
Renew MOB harness.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2007
Lifesaving › Buoyant Apparatus › Lifeline
Issued 30 May 2006
Resolved
RENEW ALL LINES ON ALL RING BOUYSMEETING CFR REQUIREMENTS PRIOR TO SAILING.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 1 June 2006
Resolution: RENEWED ALL LINES.
Electrical › Electric Generation Source (service) › Metallic Enclosure/Frame
Issued 30 May 2006
Resolved
INSTALL LAGGING ON #1 GENERATOR
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 1 June 2006
Resolution: INSTALLED EXHAUST LAGGING AS DISCUSSED.
Construction/Loadline › Structures › Door
Issued 30 May 2006
Resolved
DEMONSTRATE PROPER OPERATION OF MAIN DECK WATER TIGHT DOORS.
Action required: 17 - Rectify deficiencies prior to departure
Due 30 June 2006
Resolved 1 June 2006
Resolution: RENEWED BOTH MAIN DECK WATER TIGHT DOORS, ALL SAT.
Deck/Cargo
Issued 19 November 2001
Resolved
Dry bulk cargo tanks require inspection OOA17 April 2001. Tanks were not available for inspection at reinspection date (13 Nov 2001). Issued 835 for completion prior to 13 december 2001.
Condition: Unknown
Due 13 December 2001
Resolved 21 November 2001
Construction/Loadline
Issued 6 May 2001
Resolved
REPAIR CRUSHED BULWARK, ASSOCIATED STIFFNERS, TORN DECK, AND GOOSE NECK VENTS AT STBD QUARTER AND ACROSS STERN.
Condition: Unknown
Due 6 May 2001
Resolved 6 May 2001
Construction/Loadline
Issued 4 October 1997
Resolved
Make permanent repairs to starboard aft peak wrap around where temporary repairs were made to repair casualty damage (4 inch gash welded over).
Condition: Unknown
Due 4 October 1997
Resolved 4 October 1997
Lifesaving
Issued 20 December 1994
Resolved
Provide operable EPIRB on board vessel prior to departure from Port O'Connor, Texas, no later than 21 Dec 94._x001C_ _x001C_ (New unit provided on board prior to departure)_x001C_
Condition: Unknown
Due 21 December 1994
Resolved 23 December 1994
Documentation
Issued 20 December 1994
Resolved
Provide validly licensed Master on board vessel prior to departure, no later than 21 Dec 94._x001C_ _x001C_ (Corrected 20 Dec)_x001C_
Condition: Unknown
Due 21 December 1994
Resolved 23 December 1994
Lifesaving
Issued 20 December 1994
Resolved
MAKE AIR RECEIVERS AND DRY BULK TANKS AVAILABLE FOR INTERNAL EXAMINATION BYMARINE INPSECTOR AT NEXT DRYDOCK HULL EXAMINATION.
Condition: Unknown
Due 20 December 1994
Resolved 20 December 1994
Fire Fighting
Issued 21 February 1990
Resolved
MAIL COPY OF THE FIXED CO2 SYSTEM SERVICE REPORT (ANNUAL) TO [name withheld] OR CONDUCT SYSTEM TEST IN THE PRESENCE OF ATTENDING COAST GUARD INSPECTOR.
Condition: Unknown
Due 21 February 1990
Resolved 21 February 1990
Documentation
Issued 27 February 1989
Resolved
PROVIDE ON BOARD A LEGIBLE COPY OF THE VESSEL STABILITY LETTERS IN CONFORMITY WITH 46 CFR 93.15-01. COMPLIANCE DATE IS: 30MAR89
Condition: Unknown
Due 27 February 1989
Resolved 27 February 1989
Unknown
Issued 28 November 1988
Resolved
PROVIDE ONBOARD, A COPY OF THE APPROVED TEST PROCEDURES FOR THE ENGINE ROOMAUTOMATION/ALARMS AND PROVE SATISFACTION OPERATION OF SAME, AS OUTLINED IN NAVIGATION INSPECTION CIRCULAR (NVIC) 1-78.
Condition: Unknown
Due 28 November 1988
Resolved 28 November 1988
Documentation
Issued 5 January 1988
Resolved
PROVIDE ON BOARD A COPY OF THE APPROVED TEST PROCEDURES FOR THE ENGINE ROOM AUTOMATION IN ACCORDANCE WITH 46CFR61.20-3 AND NVIC 1-78
Condition: Unknown
Due 5 January 1988
Resolved 5 January 1988
Construction/Loadline
Issued 1 December 1987
Resolved
FREE UP PORT ENGINEROOM ESCAPE HATCH DOGS.
Condition: Unknown
Due 1 December 1987
Resolved 1 December 1987
Engineering
Issued 1 December 1987
Resolved
PUMP EXCESS WATER AND OIL FROM ENGINEROOM BILGES AND CLEAN.
Condition: Unknown
Due 1 December 1987
Resolved 1 December 1987
Engineering
Issued 1 December 1987
Resolved
CLEAN ALL VENT SCREENS IN ENGINEROOM.
Condition: Unknown
Due 1 December 1987
Resolved 1 December 1987
Electrical
Issued 1 December 1987
Resolved
REPLACE ALL BURNED OUT LIGHT BULBS IN ENGINEROOM ALARM PANEL.
Condition: Unknown
Due 1 December 1987
Resolved 1 December 1987
Navigation
Issued 1 December 1987
Resolved
REPAIR RUDDER ANGLE INDICATOR AT ENGINEROOM STATION.
Condition: Unknown
Due 1 December 1987
Resolved 1 December 1987
Electrical
Issued 1 December 1987
Resolved
REPLACE ALL BURNED OUT LIGHT BULBS IN BRIDGE ALARM PANEL.
Condition: Unknown
Due 1 December 1987
Resolved 1 December 1987
Engineering
Issued 1 December 1987
Resolved
PROVIDE TEST PROCEDURES FOR E/R ALARM PANEL AND PROVE OPERATION IN THE PRESENTS OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 1 December 1987
Resolved 1 December 1987
Engineering
Issued 1 December 1987
Resolved
REMOVE PLASTIC SIGHT TUBES ON FUEL AND LUBE OIL SYSTEMS IN ENGINEROOM OR REPLACE WITH FIRE RESISTANT GLASS.
Condition: Unknown
Due 1 December 1987
Resolved 1 December 1987
Engineering
Issued 1 December 1987
Resolved
REPAIR STEERING COMPARTMENT BILGE ALARM FLOAT ASSEMBLY.
Condition: Unknown
Due 1 December 1987
Resolved 1 December 1987
Engineering
Issued 1 December 1987
Resolved
CLEAN MAIN ENGINE AIR INTAKES.
Condition: Unknown
Due 1 December 1987
Resolved 1 December 1987
Engineering
Issued 3 December 1985
Resolved
REPAIR SHAFT TACHS IN WHEELHOUSE.
Condition: Unknown
Due 3 December 1985
Resolved 3 December 1985
Construction/Loadline
Issued 3 December 1985
Resolved
REPAIR STBD ENGINEROOM ESCAPE SCUTTLE. THE SCUTTLE IS TO BE MADE WATERTIGHT
Condition: Unknown
Due 3 December 1985
Resolved 3 December 1985
Electrical
Issued 3 December 1985
Resolved
REPAIR BOTH GENERATOR OVERSPEED TRIPS.
Condition: Unknown
Due 3 December 1985
Resolved 3 December 1985
Engineering
Issued 3 December 1985
Resolved
REPLACE FILL VALVE TO PORT AIR RECEIVER.
Condition: Unknown
Due 3 December 1985
Resolved 3 December 1985
Engineering
Issued 3 December 1985
Resolved
OPEN BOTH SHIP SERVICE AIR RECEIVERS AND FOUR (4) BULK MUD TANKS FOR INTERNAL EXAM.
Condition: Unknown
Due 3 December 1985
Resolved 3 December 1985
Electrical
Issued 3 December 1985
Resolved
REPAIR GENERATOR PARALLEL CIRCUIT AND OPERATE REVERSE POWER TRIPS IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 3 December 1985
Resolved 3 December 1985
Unknown
Issued 29 October 1983
Resolved
PLACE AT THE ENGINE ROOM STEERING STATION THE INSTRUCTIONS FOR CHANGING STERRING GEAR AS REQUIRED BY 46 CFR 97.37-33.
Condition: Unknown
Due 29 October 1983
Resolved 29 October 1983
Unknown
Issued 29 October 1983
Resolved
REPAIR THE FATHOMETER.
Condition: Unknown
Due 29 October 1983
Resolved 29 October 1983
Unknown
Issued 29 October 1983
Resolved
REPLACE THE PRESENT DRY MUD COMPRESSOR PRESSURE GAUGE WITH ONE OF THE RANGE REQUIRED BY 46 CFR 54.15-5(F).
Condition: Unknown
Due 29 October 1983
Resolved 29 October 1983
Unknown
Issued 29 October 1983
Resolved
PLACE ON BOARD THE PLACARDS OF LIFESAVING SIGNALS AND BREECHES BUOY INSTRUCTIONS REQUIRED BY 46 CFR 97.43.
Condition: Unknown
Due 29 October 1983
Resolved 29 October 1983
Unknown
Issued 29 October 1983
Resolved
RENEW AS ORIGINAL THE FROZEN FIRE MONITOR VALVE.
Condition: Unknown
Due 29 October 1983
Resolved 29 October 1983
Unknown
Issued 29 October 1983
Resolved
REPAIR THE BOW THRUSTER BRAKE WHICH IS PRESENTLY INOPERATIVE.
Condition: Unknown
Due 29 October 1983
Resolved 29 October 1983
Unknown
Issued 29 October 1983
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE GOLDEN MOON, DN641961.
Condition: Unknown
Due 29 October 1983
Resolved 29 October 1983
Unknown
Issued 29 October 1983
Resolved
PLACE ON BOARD THE PERMANENT FCC RADIOTELEPHONE LICENSE.
Condition: Unknown
Due 29 October 1983
Resolved 29 October 1983
Unknown
Issued 29 October 1983
Resolved
INSTALL THE GLASS PANELED ENCLOSURES AND MARKINGS FOR THE VENTILATION SYSTEMS EMERGENCY STOP STATIONS AS REQUIRED BY 46 CFR 111.80-10.
Condition: Unknown
Due 29 October 1983
Resolved 29 October 1983
Unknown
Issued 29 October 1983
Resolved
INSTALL A REMOTE SHUT DOWN FOR THE MACHINERY SPACE VENTILATION AS REQUIRED BY 46 CFR 111.80-10.
Condition: Unknown
Due 29 October 1983
Resolved 29 October 1983
Unknown
Issued 29 October 1983
Resolved
REPAIR THE BOW THRUSTER TACHOMETER AND OIL PRESSURE GAUGE LOCATED IN THE PILOT HOUSE.
Condition: Unknown
Due 29 October 1983
Resolved 29 October 1983