MAURY USCG vessel records Sign in
← All vessels

CARLEY T

CARLEY T is a 1981 offshore supply vessel. The Coast Guard has recorded 61 inspections since 1981, most recently in May 2020, along with 69 deficiencies — 1 with no resolution recorded —, 1 operational control and 1 casualty investigation in 2013.

Records from 1981 to 2020. Most recent: operational control imposed, 12 May 2020.

Built
1981
Last inspected
11 May 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG 9986
Flag
UNITED STATES
366910320, 367593230 (licence lapsed)
Maury page id
psix-52900

Inspections, by type

…with no type recorded18
Years with a record 33 calendar years (1981–2020)
The 61 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it93 - Regulatory (Subpart C or D), Gross Ton
63 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDG9986MMSI 367593230 · expired · compulsorily equipped · granted 25 October 2013, cancelled 30 December 2023
WDB5500MMSI 366910320 · expired · compulsorily equipped · granted 21 October 2003, cancelled 22 December 2013 · licensed under a name not among this hull’s recorded names (not shown)
WAP4353MMSI not assigned · expired · compulsorily equipped · granted 30 January 1996, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 61

11 May 2020 Type not recorded
No type recorded · Station Indian River · USCG East District (CGD-E) · Activity 6951733
7 May 2020 Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6952430
6 May 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6949207
2 May 2020 Uninspected Other · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6947186
1 January 2016 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5843599
28 October 2014 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5012837
21 October 2014 Internal Structural Exam · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5008604
7 February 2012 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4240227
26 January 2012 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4237529
26 February 2011 Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 3954260
19 October 2010 Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3872288
13 November 2008 Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3362141
26 September 2007 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3085243
20 September 2006 Re-Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2783174
20 October 2005 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2518434
11 August 2004 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2162876
5 August 2004 Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2156598
21 October 2003 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1932776
27 September 2002 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1680965
25 September 2001 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395805
5 June 2001 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214613
18 August 2000 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361657
8 September 1999 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 796190
12 August 1999 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462773
21 August 1998 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452426
13 August 1997 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407951
5 December 1996 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 877382
20 August 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463979
1 March 1996 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884972
13 September 1995 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371188
1 December 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666478
8 November 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 211987
8 November 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214057
19 October 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666479
19 October 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 706638
5 October 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214000
4 October 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 524319
1 October 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213445
22 August 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394189
12 April 1994 Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420861
7 April 1994 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 183289
29 October 1993 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466329
30 September 1993 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1140316
2 March 1993 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358024
23 August 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467360
25 March 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666480
13 February 1992 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 956053
1 August 1991 Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939388
21 January 1991 Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223509
19 January 1991 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912993
20 August 1990 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1237764
11 September 1989 Re-Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 903065
21 November 1988 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1212007
15 August 1988 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1344956
3 September 1987 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1012694
22 August 1986 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1019838
10 February 1986 Credit Drydock
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1304319
23 December 1985 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1304312
17 August 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1283171
10 September 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 966949
30 October 1981 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 966895

Deficiency record · 69

Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 October 2014 Resolved
Vessel does not have the proper endorsement on thier COD for commercial service between U.S. Ports. Vessel only has "registry" and must have "coastwise". Vessel restricted from commercial operations until a proper COD is recieved with the applicable endorsement.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2014
Resolution: MI verified paperwork and e-mail submission to NVDC for the addition of the Coastwise Endorsement on the vessel''s COD. Cleared 835.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 October 2014 Resolved
Vessel's EPRIB was registered with the wrong call sign for the vessel. Required vessel to re-register the EPIRB with the proper call sign.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 November 2014
Resolved 30 October 2014
Resolution: MI verified that the EPIRB registration paperwork was submitted for the change in call sign.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 October 2014 No resolution recorded
Vessel has an unrestricted Oceans Gulf of Mexico route on the current COI. Vessel is restricted to operations within 100 miles until a NAVTEX has been installed.
Condition: Invalid
Action required: 705 - Other - as specified
Electrical › Electrical Distribution System (service) › Switchboard
Issued 28 October 2014 Resolved
The main switchboard does not have an interlock device to prevent both generators from supplying power to the switchboard simultaniously. Install in interlock to the satisfaction of the attending MI.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2014
Resolution: MI verified that an interlock has been installed and worked as designed.
Electrical › Electric Generation Source (service) › Generator
Issued 28 October 2014 Resolved
Both armatures and windings on the #1 and #2 generators are completely covered with oil and debris resulting in a significant fire hazard. Armatures and windings are to be sufficiently cleaned to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2014
Resolution: MI attended vessel and verified that the windings and armatures were sufficiently cleaned.
Construction/Loadline › Structures › Door
Issued 28 October 2014 Resolved
Both the engineroom main deck water tight door and the 01 deck accomadation space weather tight doors had dogs that were frozen and inoperable. The Engineroom main deck access watertight door was also not water tight. Affect repairs to allow for proper operation of watertight and weather tight doors.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2014
Resolution: MI attended vessel and witnessed proper operation of all Water tight and weather tight door dogs and seals.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 28 October 2014 Resolved
Vessel is not maintaining a lifesaving equipment maintenance record. No lifesaving equipment checks are being done or documented. Vessel to implement a lifesaving equipment maintenance record and implement a program to ensure checks are completed as required.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 November 2014
Resolved 30 October 2014
Resolution: MI attended vessel and verified that the vessel has implemented a "checklist" and record to ensure that the vessel has and is maintaining a lifesaving maintenance record.
Electrical › Electrical Distribution System (service) › Cable
Issued 28 October 2014 Resolved
Electrical cables near the aft operation station were found actively sparking/smoking and grounding to the vessel's hull. Remove and renew all wasted electrical cables IVO the aft operating station. To be verified by the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2014
Resolution: The wasted electrical cable has been removed and the MI verified that proper shipboard cable has been reinstalled as required. MI verified via site visit.
Construction/Loadline › Hull › Bottom Plating
Issued 19 October 2010 Resolved
Wastage under stbd main eng. needs to be cropped/renewed. Keel cooler leaks into eng. room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2010
Resolution: New steel inserted and tested by CGMI.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 October 2010 Resolved
STBD Fuel reach rod inop
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2010
Resolution: Reach rod repaired and verified working properly by attending inspector.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 13 November 2008 Resolved
Paint draft marks on stern port and stbd
Action required: 705 - Other - as specified
Resolved 14 November 2008
Resolution: Recieved call from vsl rep stating that draft marks were painted in the yard.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 November 2008 Resolved
Provide a current Light List
Action required: 705 - Other - as specified
Due 13 December 2008
Resolved 14 November 2008
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 November 2008 Resolved
Provide approach chart for area operating
Action required: 705 - Other - as specified
Due 13 December 2009
Resolved 14 November 2008
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 13 November 2008 Resolved
Provide OSHA approved safety harness for use during man-overboard operations
Action required: 705 - Other - as specified
Due 13 December 2009
Resolved 14 November 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 26 September 2007 Resolved
Stencil emergency exit in engine room
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 26 September 2007 Resolved
Clean both generator armatures.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Engineering › Compressed Air System (start air) › Control Gear
Issued 26 September 2007 Resolved
Provide proper size pressure relief valve of ships air receiver.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 26 September 2007 Resolved
Renew stbd lube oil vent flame screen.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Navigation › Piloting/Steering › Marine Charts
Issued 26 September 2007 Resolved
Provide charts for approaches and any other areas of operation.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Lifesaving › Lifefloat › Serviceable
Issued 26 September 2007 Resolved
Service one 12 man lifefloat and provide receipt.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Lifesaving › Lifebuoys › Serviceable
Issued 26 September 2007 Resolved
Replace bad retro tape on all life rings.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Electrical › Electric Generation Source (service) › Generator
Issued 4 October 2006 Resolved
Port and Starboard generator armatures saturated with oil and grime.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2006
Resolution: Corrected.
Engineering › Fuel Oil Service System › Valve, Control
Issued 4 October 2006 Resolved
Fuel transfer piping valves not labeled.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2006
Resolution: Corrected.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 4 October 2006 Resolved
Fuel transfer procedures not at the transfer stations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2006
Resolution: Corrected.
Engineering › Compressed Air System (start air) › Valve
Issued 4 October 2006 Resolved
Pressure vessel relief valve inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2006
Resolution: Corrected.
Stability › Watertight Integrity › General
Issued 4 October 2006 Resolved
Engine room watertight door gasket covered with paint.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2006
Resolution: Corrected.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 4 October 2006 Resolved
Dryer venting lint directly into the space unfiltered.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2006
Resolution: Corrected.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 4 October 2006 Resolved
SSB inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2006
Resolution: Corrected.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 20 October 2005 Resolved
Provide vsl specific Ballast Water management plan prior to 20 Nov or before conducting ballast water operations.
Condition: Unknown
Due 20 November 2005
Resolved 24 October 2005
Resolution: Plan provided.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 October 2005 Resolved
Vessel operated from 19 August 2005 to 17 October 2005 with an expired certificate.
Condition: Unknown
Due 20 October 2005
Resolved 24 October 2005
Lifesaving › Hand Flares › Quantity
Issued 21 October 2003 Resolved
Provide 1 orange smoke and 1 red flare.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 October 2003 Resolved
Renew anchor light.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Construction/Loadline › Structures › Door
Issued 21 October 2003 Resolved
Make repairs and adjustments to main deck, 01 deck aft, and 01 deck port watertight doors.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Engineering › Fuel Oil Service System › Hose
Issued 21 October 2003 Resolved
Make reairs to all marked fuel hoses on both main engines and both generators.
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 October 2003 Resolved
Renew all marked aft steering hydraulic hoses.
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 21 October 2003 Resolved
Renew batteries for emergency lighting.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 October 2003 Resolved
Properly splice electrical wires on both main engines.
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Construction/Loadline › Penetrations
Issued 21 October 2003 Resolved
Tighten and seal stuffing tubes over engine room watertight door. LEGACY COMPONENT DESC: Stuffing Tube
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 21 October 2003 Resolved
Provide light cover and globe for lighting fixture in generator room.
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 October 2003 Resolved
Provide first aid kit.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 October 2003 Resolved
Provide updated light list and US coast pilot.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Fire Fighting › Means of Escape › Escape Route Signs
Issued 21 October 2003 Resolved
Stencil engine room emergency exit.
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 21 October 2003 Resolved
Provide 3 new lifejackets.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 October 2003 Resolved
Provide missing covers for 110v outlets.
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Accommodation/Occupational Safety › Potable Water System
Issued 21 October 2003 Resolved
Provide bug screen for potable water vent. LEGACY COMPONENT DESC: Bug Screens
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 September 2002 Resolved
Restencil liferings throughout vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Lifesaving › Lifebuoys
Issued 27 September 2002 Resolved
Renew retroflective markings on port lifering. LEGACY COMPONENT DESC: Retro tape
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Lifesaving › Buoyant Apparatus
Issued 27 September 2002 Resolved
Repair water light on lifefloat. LEGACY COMPONENT DESC: Water light
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Electrical › Lighting (service) › Lighting Fixture
Issued 27 September 2002 Resolved
Provide globe for flourscent light in engineroom.
Due 27 October 2002
Resolved 2 October 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 27 September 2002 Resolved
Provide flame screen for main deck lube oil vent.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2002
Resolved 2 October 2002
Stability › Watertight Integrity
Issued 27 September 2002 Resolved
Renew gasket on aft watertight door. LEGACY COMPONENT DESC: Gasket
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Stability › Watertight Integrity
Issued 27 September 2002 Resolved
Adjust all watertight doors. LEGACY COMPONENT DESC: Watertight doors
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Electrical › Electric Supply System (service)
Issued 27 September 2002 Resolved
Repair overspeed device on port generator. LEGACY COMPONENT DESC: Overspeed device
Action required: 705 - Other - as specified
Due 27 October 2002
Resolved 2 October 2002
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 September 2002 Resolved
Provide current 2002 Light lists.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 27 September 2002 Resolved
Provide current 2002 notice to mariners.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 September 2002 Resolved
Provide current coast pilot.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 September 2002 Resolved
Provide current Tide/Current tables.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Navigation › Piloting/Steering › Compass Deviation Table
Issued 27 September 2002 Resolved
Provide current compass deviation table.
Action required: 705 - Other - as specified
Due 27 October 2002
Resolved 2 October 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 27 September 2002 Resolved
Provide annual testing of diesel fuel transfer hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2002
Resolved 2 October 2002
Communications › Radio Communications › EPIRB
Issued 27 September 2002 Resolved
Renew EPIRB antennae.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Construction/Loadline › Hull › Bottom Plating
Issued 27 September 2002 Resolved
Crop and renewt existing doubler plate under starboard shaft.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Engineering › Steering Gear System › Rudder Bearing
Issued 27 September 2002 Resolved
Renew rudder bearings.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Lifesaving
Issued 12 August 1999 Resolved
DEMONSTRATE COMPLIANCE WITH 8TH COAST GUARD DISTRICT POLICY FOR RESCUE BOATREQUIREMENT OF OFFSHORE SUPPLY VESSELS DATED 12NOV98 TO THE SATISFACTION OFATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Engineering
Issued 20 August 1996 Resolved
REPAIR MAIN ENGINE EXHAUST LEAKS TO THE SATISFACTION OF ATTENDING CG MARINEINSPECTOR.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Construction/Loadline
Issued 20 August 1996 Resolved
MAKE REPAIRS TO ENGINE ROOM EMERGENCY ESCAPE HATCH AND TRUNK TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Fire Fighting
Issued 20 August 1996 Resolved
RENEW (ADDITIONAL) SECTION OF FIRE MONITOR PIPING IN GENERATOR ROOM TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Electrical
Issued 20 August 1996 Resolved
INSTALL BATTERY CHARGER FOR PORT GENERATOR MEETING THE REQUIREMENTS OF UL1236, INSTALLATION TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Construction/Loadline
Issued 20 August 1996 Resolved
MAKE 100% PENETRATION WELDS ON EXISTING ENGINE ROOM ACCESS CUT-OUTS ON MAINDECK TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Unknown
Issued 19 January 1991 Resolved
MAKE PERMANENT REPAIRS TO COLLISION DAMAGE AT PORT SIDE OF FOREDECK.
Condition: Unknown
Due 19 January 1991
Resolved 19 January 1991

Casualty record · 1

11 July 2013Routine · role: Involved in a Marine Casualty · activity 4650147
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.