Records from 1981 to 2020. Most recent: operational control imposed, 12 May 2020.
Inspection history · 61
11 May 2020
Type not recorded
No type recorded · Station Indian River · USCG East District (CGD-E) · Activity 6951733
7 May 2020
Administrative Inspection
Administrative · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 6952430
6 May 2020
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6949207
2 May 2020
Uninspected Other · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6947186
1 January 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5843599
28 October 2014
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5012837
21 October 2014
Internal Structural Exam · Hull Examination · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5008604
7 February 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4240227
26 January 2012
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4237529
26 February 2011
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 3954260
19 October 2010
Examination of Repairs · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3872288
13 November 2008
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3362141
26 September 2007
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3085243
20 September 2006
Re-Inspection · Internal Structural Exam · Hull Examination · Examination of Repairs · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2783174
20 October 2005
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2518434
11 August 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2162876
5 August 2004
Internal Structural Exam · Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2156598
21 October 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1932776
27 September 2002
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1680965
25 September 2001
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1395805
5 June 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214613
18 August 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1361657
8 September 1999
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 796190
12 August 1999
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462773
21 August 1998
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1452426
13 August 1997
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407951
5 December 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 877382
20 August 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1463979
1 March 1996
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884972
13 September 1995
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1371188
1 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666478
8 November 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 211987
8 November 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214057
19 October 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666479
19 October 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 706638
5 October 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214000
4 October 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 524319
1 October 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 213445
22 August 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1394189
12 April 1994
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1420861
7 April 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 183289
29 October 1993
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466329
30 September 1993
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1140316
2 March 1993
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1358024
23 August 1992
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1467360
25 March 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 666480
13 February 1992
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 956053
1 August 1991
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939388
21 January 1991
Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1223509
19 January 1991
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 912993
20 August 1990
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1237764
11 September 1989
Re-Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 903065
21 November 1988
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1212007
15 August 1988
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1344956
3 September 1987
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1012694
22 August 1986
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1019838
10 February 1986
Credit Drydock
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1304319
23 December 1985
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1304312
17 August 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1283171
10 September 1982
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 966949
30 October 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 966895
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 28 October 2014
Resolved
Vessel does not have the proper endorsement on thier COD for commercial service between U.S. Ports. Vessel only has "registry" and must have "coastwise". Vessel restricted from commercial operations until a proper COD is recieved with the applicable endorsement.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2014
Resolution: MI verified paperwork and e-mail submission to NVDC for the addition of the Coastwise Endorsement on the vessel''s COD. Cleared 835.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 28 October 2014
Resolved
Vessel's EPRIB was registered with the wrong call sign for the vessel. Required vessel to re-register the EPIRB with the proper call sign.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 4 November 2014
Resolved 30 October 2014
Resolution: MI verified that the EPIRB registration paperwork was submitted for the change in call sign.
Communications › Radio Communications › VHF Radiotelephone
Issued 28 October 2014
No resolution recorded
Vessel has an unrestricted Oceans Gulf of Mexico route on the current COI. Vessel is restricted to operations within 100 miles until a NAVTEX has been installed.
Condition: Invalid
Action required: 705 - Other - as specified
Electrical › Electrical Distribution System (service) › Switchboard
Issued 28 October 2014
Resolved
The main switchboard does not have an interlock device to prevent both generators from supplying power to the switchboard simultaniously. Install in interlock to the satisfaction of the attending MI.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2014
Resolution: MI verified that an interlock has been installed and worked as designed.
Electrical › Electric Generation Source (service) › Generator
Issued 28 October 2014
Resolved
Both armatures and windings on the #1 and #2 generators are completely covered with oil and debris resulting in a significant fire hazard. Armatures and windings are to be sufficiently cleaned to the satisfaction of the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2014
Resolution: MI attended vessel and verified that the windings and armatures were sufficiently cleaned.
Construction/Loadline › Structures › Door
Issued 28 October 2014
Resolved
Both the engineroom main deck water tight door and the 01 deck accomadation space weather tight doors had dogs that were frozen and inoperable. The Engineroom main deck access watertight door was also not water tight. Affect repairs to allow for proper operation of watertight and weather tight doors.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2014
Resolution: MI attended vessel and witnessed proper operation of all Water tight and weather tight door dogs and seals.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 28 October 2014
Resolved
Vessel is not maintaining a lifesaving equipment maintenance record. No lifesaving equipment checks are being done or documented. Vessel to implement a lifesaving equipment maintenance record and implement a program to ensure checks are completed as required.
Condition: Invalid
Action required: 705 - Other - as specified
Due 4 November 2014
Resolved 30 October 2014
Resolution: MI attended vessel and verified that the vessel has implemented a "checklist" and record to ensure that the vessel has and is maintaining a lifesaving maintenance record.
Electrical › Electrical Distribution System (service) › Cable
Issued 28 October 2014
Resolved
Electrical cables near the aft operation station were found actively sparking/smoking and grounding to the vessel's hull. Remove and renew all wasted electrical cables IVO the aft operating station. To be verified by the attending MI.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 October 2014
Resolution: The wasted electrical cable has been removed and the MI verified that proper shipboard cable has been reinstalled as required. MI verified via site visit.
Construction/Loadline › Hull › Bottom Plating
Issued 19 October 2010
Resolved
Wastage under stbd main eng. needs to be cropped/renewed. Keel cooler leaks into eng. room
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2010
Resolution: New steel inserted and tested by CGMI.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 October 2010
Resolved
STBD Fuel reach rod inop
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2010
Resolution: Reach rod repaired and verified working properly by attending inspector.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 13 November 2008
Resolved
Paint draft marks on stern port and stbd
Action required: 705 - Other - as specified
Resolved 14 November 2008
Resolution: Recieved call from vsl rep stating that draft marks were painted in the yard.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 November 2008
Resolved
Provide a current Light List
Action required: 705 - Other - as specified
Due 13 December 2008
Resolved 14 November 2008
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 13 November 2008
Resolved
Provide approach chart for area operating
Action required: 705 - Other - as specified
Due 13 December 2009
Resolved 14 November 2008
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 13 November 2008
Resolved
Provide OSHA approved safety harness for use during man-overboard operations
Action required: 705 - Other - as specified
Due 13 December 2009
Resolved 14 November 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 26 September 2007
Resolved
Stencil emergency exit in engine room
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 26 September 2007
Resolved
Clean both generator armatures.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Engineering › Compressed Air System (start air) › Control Gear
Issued 26 September 2007
Resolved
Provide proper size pressure relief valve of ships air receiver.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 26 September 2007
Resolved
Renew stbd lube oil vent flame screen.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Navigation › Piloting/Steering › Marine Charts
Issued 26 September 2007
Resolved
Provide charts for approaches and any other areas of operation.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Lifesaving › Lifefloat › Serviceable
Issued 26 September 2007
Resolved
Service one 12 man lifefloat and provide receipt.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Lifesaving › Lifebuoys › Serviceable
Issued 26 September 2007
Resolved
Replace bad retro tape on all life rings.
Action required: 705 - Other - as specified
Due 26 October 2007
Resolved 27 September 2007
Electrical › Electric Generation Source (service) › Generator
Issued 4 October 2006
Resolved
Port and Starboard generator armatures saturated with oil and grime.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2006
Resolution: Corrected.
Engineering › Fuel Oil Service System › Valve, Control
Issued 4 October 2006
Resolved
Fuel transfer piping valves not labeled.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2006
Resolution: Corrected.
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 4 October 2006
Resolved
Fuel transfer procedures not at the transfer stations.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2006
Resolution: Corrected.
Engineering › Compressed Air System (start air) › Valve
Issued 4 October 2006
Resolved
Pressure vessel relief valve inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2006
Resolution: Corrected.
Stability › Watertight Integrity › General
Issued 4 October 2006
Resolved
Engine room watertight door gasket covered with paint.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2006
Resolution: Corrected.
Fire Fighting › Combustible Materials › Furniture/Furnishings
Issued 4 October 2006
Resolved
Dryer venting lint directly into the space unfiltered.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2006
Resolution: Corrected.
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 4 October 2006
Resolved
SSB inoperable.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 October 2006
Resolution: Corrected.
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 20 October 2005
Resolved
Provide vsl specific Ballast Water management plan prior to 20 Nov or before conducting ballast water operations.
Condition: Unknown
Due 20 November 2005
Resolved 24 October 2005
Resolution: Plan provided.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 20 October 2005
Resolved
Vessel operated from 19 August 2005 to 17 October 2005 with an expired certificate.
Condition: Unknown
Due 20 October 2005
Resolved 24 October 2005
Lifesaving › Hand Flares › Quantity
Issued 21 October 2003
Resolved
Provide 1 orange smoke and 1 red flare.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 October 2003
Resolved
Renew anchor light.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Construction/Loadline › Structures › Door
Issued 21 October 2003
Resolved
Make repairs and adjustments to main deck, 01 deck aft, and 01 deck port watertight doors.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Engineering › Fuel Oil Service System › Hose
Issued 21 October 2003
Resolved
Make reairs to all marked fuel hoses on both main engines and both generators.
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Engineering › Steering Gear System › Hydraulic Hose
Issued 21 October 2003
Resolved
Renew all marked aft steering hydraulic hoses.
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 21 October 2003
Resolved
Renew batteries for emergency lighting.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 October 2003
Resolved
Properly splice electrical wires on both main engines.
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Construction/Loadline › Penetrations
Issued 21 October 2003
Resolved
Tighten and seal stuffing tubes over engine room watertight door. LEGACY COMPONENT DESC: Stuffing Tube
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 21 October 2003
Resolved
Provide light cover and globe for lighting fixture in generator room.
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 October 2003
Resolved
Provide first aid kit.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 October 2003
Resolved
Provide updated light list and US coast pilot.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Fire Fighting › Means of Escape › Escape Route Signs
Issued 21 October 2003
Resolved
Stencil engine room emergency exit.
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 21 October 2003
Resolved
Provide 3 new lifejackets.
Action required: 17 - Rectify deficiencies prior to departure
Due 21 November 2003
Resolved 23 October 2003
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 October 2003
Resolved
Provide missing covers for 110v outlets.
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Accommodation/Occupational Safety › Potable Water System
Issued 21 October 2003
Resolved
Provide bug screen for potable water vent. LEGACY COMPONENT DESC: Bug Screens
Action required: 705 - Other - as specified
Due 21 November 2003
Resolved 23 October 2003
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 September 2002
Resolved
Restencil liferings throughout vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Lifesaving › Lifebuoys
Issued 27 September 2002
Resolved
Renew retroflective markings on port lifering. LEGACY COMPONENT DESC: Retro tape
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Lifesaving › Buoyant Apparatus
Issued 27 September 2002
Resolved
Repair water light on lifefloat. LEGACY COMPONENT DESC: Water light
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Electrical › Lighting (service) › Lighting Fixture
Issued 27 September 2002
Resolved
Provide globe for flourscent light in engineroom.
Due 27 October 2002
Resolved 2 October 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Flame Screens
Issued 27 September 2002
Resolved
Provide flame screen for main deck lube oil vent.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2002
Resolved 2 October 2002
Stability › Watertight Integrity
Issued 27 September 2002
Resolved
Renew gasket on aft watertight door. LEGACY COMPONENT DESC: Gasket
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Stability › Watertight Integrity
Issued 27 September 2002
Resolved
Adjust all watertight doors. LEGACY COMPONENT DESC: Watertight doors
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Electrical › Electric Supply System (service)
Issued 27 September 2002
Resolved
Repair overspeed device on port generator. LEGACY COMPONENT DESC: Overspeed device
Action required: 705 - Other - as specified
Due 27 October 2002
Resolved 2 October 2002
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 September 2002
Resolved
Provide current 2002 Light lists.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 27 September 2002
Resolved
Provide current 2002 notice to mariners.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Navigation › Piloting/Steering › US Coast Pilot
Issued 27 September 2002
Resolved
Provide current coast pilot.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 September 2002
Resolved
Provide current Tide/Current tables.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Navigation › Piloting/Steering › Compass Deviation Table
Issued 27 September 2002
Resolved
Provide current compass deviation table.
Action required: 705 - Other - as specified
Due 27 October 2002
Resolved 2 October 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 27 September 2002
Resolved
Provide annual testing of diesel fuel transfer hose.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 October 2002
Resolved 2 October 2002
Communications › Radio Communications › EPIRB
Issued 27 September 2002
Resolved
Renew EPIRB antennae.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Construction/Loadline › Hull › Bottom Plating
Issued 27 September 2002
Resolved
Crop and renewt existing doubler plate under starboard shaft.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Engineering › Steering Gear System › Rudder Bearing
Issued 27 September 2002
Resolved
Renew rudder bearings.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 October 2002
Resolved 2 October 2002
Lifesaving
Issued 12 August 1999
Resolved
DEMONSTRATE COMPLIANCE WITH 8TH COAST GUARD DISTRICT POLICY FOR RESCUE BOATREQUIREMENT OF OFFSHORE SUPPLY VESSELS DATED 12NOV98 TO THE SATISFACTION OFATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 August 1999
Resolved 12 August 1999
Engineering
Issued 20 August 1996
Resolved
REPAIR MAIN ENGINE EXHAUST LEAKS TO THE SATISFACTION OF ATTENDING CG MARINEINSPECTOR.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Construction/Loadline
Issued 20 August 1996
Resolved
MAKE REPAIRS TO ENGINE ROOM EMERGENCY ESCAPE HATCH AND TRUNK TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Fire Fighting
Issued 20 August 1996
Resolved
RENEW (ADDITIONAL) SECTION OF FIRE MONITOR PIPING IN GENERATOR ROOM TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Electrical
Issued 20 August 1996
Resolved
INSTALL BATTERY CHARGER FOR PORT GENERATOR MEETING THE REQUIREMENTS OF UL1236, INSTALLATION TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Construction/Loadline
Issued 20 August 1996
Resolved
MAKE 100% PENETRATION WELDS ON EXISTING ENGINE ROOM ACCESS CUT-OUTS ON MAINDECK TO THE SATISFACTION OF ATTENDING CG MARINE INSPECTOR.
Condition: Unknown
Due 20 August 1996
Resolved 20 August 1996
Unknown
Issued 19 January 1991
Resolved
MAKE PERMANENT REPAIRS TO COLLISION DAMAGE AT PORT SIDE OF FOREDECK.
Condition: Unknown
Due 19 January 1991
Resolved 19 January 1991