Records from 1981 to 2012. Most recent: inspection, 24 May 2012.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Construction/Loadline › Hull › Side Shell
Issued 24 February 2011
Resolved
Repair areas marked on stbd bow & areas marked on hull IAW NVIC 7-95.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2011
Construction/Loadline › Hull › Transverse Frame
Issued 24 February 2011
Resolved
Replace frames 3, 4, 5, &7 located stbd engine room & frames 6, 7, & 8 on port engine room (marked).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2011
Construction/Loadline › Hull › Side Shell
Issued 24 February 2011
Resolved
Replace PVC cap with metal cap for E/R thru hull fitting.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2011
Engineering › Steering Gear System › Rudder Bearing
Issued 24 February 2011
Resolved
Replace both rudders on vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2011
Engineering › Steering Gear System › Rudder
Issued 12 January 2009
Resolved
Repack rudders (port and starboard) side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2009
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 12 January 2009
Resolved
Replace cutlass bearings on starboard shaft.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2009
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 12 January 2009
Resolved
Replace/Repair starboard propeller.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2009
Construction/Loadline › Hull › Side Shell
Issued 12 January 2009
Resolved
Replace two marked hull planks on starboard side.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2009
Construction/Loadline › Hull › Side Shell
Issued 12 January 2009
Resolved
Fill seams marked on port and starboard sides of vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2009
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 12 January 2009
Resolved
Remove all oil and water from bilges.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2009
Construction/Loadline › Structures › Transverse Bulkhead
Issued 12 January 2009
Resolved
Refasten marked transverse frame in forward bilge.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2009
Construction/Loadline › Hull › Side Shell
Issued 12 January 2009
Resolved
Fill strip planking on starboard bow below deck.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2009
Construction/Loadline › Hull › Stiffener
Issued 12 January 2009
Resolved
Replace port and starboard butt blocks located outboard of port and starboard engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 February 2009
Communications › Radio Communications › EPIRB
Issued 19 August 2008
Resolved
Register expired EPIRB registration.
Due 19 September 2008
Resolved 28 August 2008
Communications › Radio Communications › EPIRB
Issued 19 August 2008
Resolved
Replace expired EPIRB battery.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2008
Lifesaving › Lifefloat › Serviceable
Issued 19 August 2008
Resolved
Repair or replace life float (retroflective cracked foam, and properly attach sea painter).
Due 19 September 2008
Resolved 28 August 2008
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 19 August 2008
Resolved
Repair bilge high water alarms.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 September 2008
Resolved 28 August 2008
Navigation › Piloting/Steering › Magnetic Compass
Issued 19 August 2008
Resolved
Properly mount bridge compass.
Due 19 September 2008
Resolved 28 August 2008
Engineering › Fuel Oil Service System › Valve
Issued 19 August 2008
Resolved
Repair and label access to emergency fuel shut downs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 August 2008
Resolved
Remove all items under bridge console around electrical wires.
Due 19 September 2008
Resolved 28 August 2008
Construction/Loadline › Penetrations › Gasket
Issued 19 August 2008
Resolved
Tighten loose rudder post on port side.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 August 2008
Electrical › Electric Generation Source (service) › Grounding Conductor
Issued 19 August 2008
Resolved
Remove loose wires on generator, and on the starboard side of the engine room.
Due 19 September 2008
Resolved 28 August 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 19 August 2008
Resolved
Provide documentation for service of portable, and fixed fire extinguishers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 August 2008
Pollution Prevention/Response › Prevention Equipment › Standard Discharge Connection
Issued 19 August 2008
Resolved
Repair leak on PVC elbow for live well.
Due 19 September 2008
Resolved 28 August 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 August 2008
Resolved
Provide battery box covers for battery banks.
Due 19 September 2008
Resolved 28 August 2008
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 17 May 2007
Resolved
Service all portable fire appliances, noted to be 3 months past due. 46CFR176
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2007
Resolved 22 May 2007
Lifesaving › Lifefloat › Platform
Issued 17 May 2007
Resolved
Provide a mount and support for lifefloat, noted to be unsecured on foredeck. 46CFR180
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2007
Resolved 22 May 2007
Lifesaving › Lifebuoys › Serviceable
Issued 17 May 2007
Resolved
Provide new retroflective tape for lifering buoy. 46CFR185.604
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2007
Resolved 22 May 2007
Lifesaving › Hand Flares › Expired
Issued 17 May 2007
Resolved
Renew expired flares which expired on 01JUN07 as per 46 CFR 180.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2007
Resolved 22 May 2007
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 17 May 2007
Resolved
Provide handle for MSD overboard shutoff valve. 33CFR159
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2007
Resolved 22 May 2007
Engineering › Lubricating Oil Storage/Transfer System › Hose
Issued 17 May 2007
Resolved
Repair/replace leaking oil pressure line to starboard main engine. 46CFR176
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2007
Resolved 22 May 2007
Operations/Management › Drills/Instruction › Abandon Ship
Issued 17 May 2007
Resolved
Conduct sea trials and drills. 46CFR (var. sec's)
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2007
Resolved 22 May 2007
Engineering › Thrusters › Bearing
Issued 21 March 2007
Resolved
Replace the port cutlass bearing in accordance with 46 CFR 176.630.
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 26 March 2007
Resolution: Replaced port cutlass bearing as required
Construction/Loadline › Penetrations › Valve Flange
Issued 21 March 2007
Resolved
Prove proper operation of the head overboard discharge valve in accordance with 46 CFR 176.16.
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 26 March 2007
Resolution: Head overboard discharge repaired
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 21 March 2007
Resolved
Prove proper operation of the lazarette hatch in accordance with 46 CFR 176.16.
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 26 March 2007
Resolution: Lazarette hatch repaired
Construction/Loadline › Structures › Superstructure
Issued 21 March 2007
Resolved
Make repairs on starboard side deck aft of the pilot house where rotting in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 21 April 2007
Resolved 26 March 2007
Resolution: Rotting area replaced
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 March 2006
Resolved
Repair operational stern light. COLREGS
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 April 2006
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 30 March 2006
Resolved
Conduct annual inspection and servicing of fixed and portable fire fighting systems and provide evidence as required by 46CFR181.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 April 2006
Operations/Management › Drills/Instruction › Abandon Ship
Issued 30 March 2006
Resolved
Provide logbook, conduct and log required drills and EPIRB tests as required by 46CFR185.420.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 April 2006
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 30 March 2006
Resolved
Properly adjustment shaft packing to stop/slow continuous flow of seawater.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2006
Resolved 9 May 2006
Stability › Unintentional Flooding › General
Issued 30 March 2006
Resolved
Label bilge "High Level Alarm" panel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 April 2006
Electrical › Electric Generation Source (service) › Generator
Issued 30 March 2006
Resolved
Make repairs to non-operational generator or remove from service.
Action required: 705 - Other - as specified
Resolved 4 April 2006
Resolution: Witnessed electrical connections and fuel lines disconnected from generator.
Documentation › Certificates/Documents › FCC SSL
Issued 19 September 2005
Resolved
Obtain FCC Radio Safety Certificate. 47CFR80.
Action required: 705 - Other - as specified
Due 19 October 2005
Resolved 30 March 2006
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 19 September 2005
Resolved
Obtain Radio Operator Permit.
Action required: 705 - Other - as specified
Due 19 October 2005
Resolved 30 March 2006
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 September 2005
Resolved
Replace stern and masthead navigation lights. COLREGS
Action required: 705 - Other - as specified
Due 19 October 2005
Resolved 21 November 2005
Construction/Loadline › Structures › Superstructure
Issued 19 September 2005
Resolved
Replace cracked and glazed windows (3).
Action required: 705 - Other - as specified
Due 19 October 2005
Resolved 21 November 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 19 September 2005
Resolved
Demonstrate start of port MDE from bridge.
Action required: 705 - Other - as specified
Due 19 October 2005
Resolved 30 March 2006
Lifesaving › Lifefloat › Lifeline
Issued 19 September 2005
Resolved
Repair cracks on Lifefloat and replace retro-tape and grab line.
Action required: 705 - Other - as specified
Due 19 October 2005
Resolved 30 March 2006
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 19 September 2005
Resolved
Remove garbage and cleaning/repair materials from behind the radio installation.
Action required: 705 - Other - as specified
Due 19 October 2005
Resolved 21 November 2005
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 19 September 2005
Resolved
Repair aft rails on upper deck; label access ladder "No Passengers".
Action required: 705 - Other - as specified
Due 19 October 2005
Resolved 30 March 2006
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 19 September 2005
Resolved
Mount, repair and test forward high level alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2006
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 19 September 2005
Resolved
Replace missing panel form aft engine room bulkhead.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 November 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 19 September 2005
Resolved
Repair excessive shaft leakage.
Action required: 705 - Other - as specified
Due 19 October 2005
Resolved 21 November 2005
Construction/Loadline › Hull › Hull Plating
Issued 17 March 2005
Resolved
Repair rotten area in strip planking six inches below waterline at starboard bow in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 4 April 2005
Resolution: Two strip planks were cut out and replace with a single plank which was then cross-nailed to adjacent planks.
Construction/Loadline › Hull › Hull Plating
Issued 17 March 2005
Resolved
Replace rotted plank on starboard side, three feet aft of stem, one foot below waterline in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 4 April 2005
Resolution: Plank was replaced in kind.
Construction/Loadline › Hull › Hull Plating
Issued 17 March 2005
Resolved
Recaulk three planks on starboard side fifteen feet from stem, four foot inboard of chine in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 17 April 2005
Resolved 4 April 2005
Resolution: Planks were recaulked.
Construction/Loadline › Hull › Hull Plating
Issued 17 March 2005
Resolved
Replace holed plank on transom one inch above waterline in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 4 April 2005
Resolution: Plank was replaced in kind.
Construction/Loadline › Hull › Hull Plating
Issued 17 March 2005
Resolved
Renew/repair cracked floating frame on port side forward of collision bulkhead in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 4 April 2005
Resolution: A similar plank was laminated by epoxying wood strips and sistering the new plank to the cracked one.
Construction/Loadline › Hull › Hull Plating
Issued 17 March 2005
Resolved
Renew/replace proud plankthree feet aft of stem one inch below waterline on port side in accordance with NVIC 7-95.
Action required: 705 - Other - as specified
Due 17 March 2005
Resolved 4 April 2005
Resolution: Plank was replaced in kind.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 18 August 2004
Resolved
Noted control panel functions to be inoperative on fixed fire fighting system. Have certified technician make repairs and provide report.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2004
Resolved 20 August 2004
Documentation › Logs/Records › Logbook (official)
Issued 18 August 2004
Resolved
Provide "Lifesaving Equipment Maintenance Record" for applicable equipment listed in 46FR185.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 September 2004
Resolved 21 November 2005
Documentation › Logs/Records › Logbook (official)
Issued 18 August 2004
Resolved
Provide "Bridge Log " or other suitable method of recording all required entries under 46CFR185.
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 September 2004
Resolved 21 November 2005
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 18 August 2004
Resolved
Repair vessel's main signaling device. 33CFR86
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2004
Resolved 20 August 2004
Communications › Internal Communications System › Sound-powered Telephone
Issued 18 August 2004
Resolved
Repair Public Address System/Bullhorn. 46CFR184.610
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2004
Resolved 20 August 2004
Communications › Radio Communications › EPIRB
Issued 18 August 2004
Resolved
Service or Replace EPIRB. Noted attenna to break off in hand. 46CFR180.64
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2004
Resolved 20 August 2004
Operations/Management › Drills/Instruction › Safety Orientation
Issued 18 August 2004
Resolved
Provide "Passenger Safety Orientation" IAW 46 CFR 185.506
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 September 2004
Resolved 21 November 2005
Lifesaving › Lifefloat › Lifeline
Issued 18 August 2004
Resolved
Replace Pendants, Painter and Basket Support Lines on Lifefloat IAW 46 CFR 180.137.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2004
Resolved 21 November 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 August 2004
Resolved
Provide approved First Aid Kit. 46CFR184.710
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2004
Resolved 20 August 2004
Fire Fighting › Fire Bucket › Capacity
Issued 18 August 2004
Resolved
Provide (3) two-half gallon capacity "Fire Buckets". 46CFR181.610
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 September 2004
Resolved 20 August 2004
Engineering › Bilge Water Management System › Not Operational
Issued 18 August 2004
Resolved
Repair "High Level Alarm" in forward compartment. 46CFR182.530
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 September 2004
Resolved 20 August 2004
Documentation › Certificates/Documents
Issued 17 April 2003
Resolved
Provide proper statoin license & safety radio telephone certificate per 47 CFR 80 LEGACY COMPONENT DESC: Station License
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 17 April 2003
Resolution: Provide temporary certificates.
Documentation › Manuals/Policy Documentation
Issued 17 April 2003
Resolved
Provide waste management plan per 33 CFR 151.57 LEGACY COMPONENT DESC: Waste management Plan
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided waste management plan.
Documentation › Certificates/Documents
Issued 17 April 2003
Resolved
Provide updated fixed fire fighting servicing certificates per 46 CFR 176.810(b)(2) LEGACY COMPONENT DESC: Fixed FF Servicing
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided fixed fire fighting servicing certificate.
Documentation › Logs/Records
Issued 17 April 2003
Resolved
Provide training logbook wiht a description of the training & persons attended per 46CFR185.420 LEGACY COMPONENT DESC: Training
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided training logbook wiht a description of the training & persons attended per 46CFR185.420
Documentation › Markings/Placards
Issued 17 April 2003
Resolved
Provide emergency instructions per 46CFR185.570 LEGACY COMPONENT DESC: Emergency Instructions
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided emergency instructions.
Navigation › Piloting/Steering
Issued 17 April 2003
Resolved
Provide current navigation publications and charts per 46CFR184.420 LEGACY COMPONENT DESC: Marine Charts
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided current navigation publications and charts per 46CFR184.420
Navigation › Collision/Grounding Avoidance
Issued 17 April 2003
Resolved
Provide a bell with a clanker per 72COLREGS. LEGACY COMPONENT DESC: Sound signal
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided a bell with a clanker per 72COLREGS.
Navigation › Piloting/Steering
Issued 17 April 2003
Resolved
Provide emergency broadcast placard per 46CFR184.506
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided emergency broadcast placard per 46CFR184.506
Communications › Internal Communications System
Issued 17 April 2003
Resolved
Demonstrate proper operation of the public address system per 46CFR184.610
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner demonstrated proper operation of the public address system per 46CFR184.610
Accommodation/Occupational Safety › Occupational Safety
Issued 17 April 2003
Resolved
Remove bilge oil and flotsom from stringers throughout vessel prior to carrying passengers.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner removed bilge oil and flotsom from stringers throughout vessel prior to carrying passengers.
Fire Fighting › Miscellaneous Items
Issued 17 April 2003
Resolved
Provide at least 3 2-1/2 gallon buckets with name of vessel & "FIRE BUCKET" stenciled and 6 ft lanyard per 46CFR1851.610.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided at least 3 2-1/2 gallon buckets with name of vessel & "FIRE BUCKET" stenciled and 6 ft lanyard per 46CFR1851.610.
Fire Fighting › Means of Escape
Issued 17 April 2003
Resolved
Mark forward escape hatch per 46CFR185.30-15(1995) LEGACY COMPONENT DESC: Marking
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner marked forward escape hatch per 46CFR185.30-15(1995)
Accommodation/Occupational Safety › Medical/First Aid
Issued 17 April 2003
Resolved
Provide first aid kit with proper items per 46CFR180.70 LEGACY COMPONENT DESC: Medicine Chest
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided first aid kit with proper items per 46CFR180.70
Lifesaving › Lifebuoys
Issued 17 April 2003
Resolved
Provide waterlight for lifering & proper lanyard per 46CFR180.70. LEGACY COMPONENT DESC: Self-igniting Lights
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided waterlight for lifering & proper lanyard per 46CFR180.70.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 17 April 2003
Resolved
Re-locate fixed firefighting ageant in the engine room
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 17 April 2003
Resolution: Fireboy relocated from port side forward to the center of the engine room with the nozzle facing aft.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 April 2003
Resolved
Replace non-metallic hose on port main engine for the fuel return line. Ensure hose meet requirements of 46CFR182.720.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner replaced non-metallic hose on port main engine for the fuel return line. Ensured hose met requirements of 46CFR182.720.
Construction/Loadline › Penetrations
Issued 17 April 2003
Resolved
Plug through hull penetration at Frame 1, below the sheer clamp. 46CFR179.350.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner plugged through hull penetration at Frame 1, below the sheer clamp. 46CFR179.350.
Pollution Prevention/Response › Prevention Equipment
Issued 17 April 2003
Resolved
Replace piping for sewage overboard discharge & provide lock per 33CFR159 LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 17 April 2003
Pollution Prevention/Response › Prevention Equipment
Issued 17 April 2003
Resolved
Provide screen for sewage tank vent. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided screen for sewage tank vent.
Construction/Loadline › Penetrations
Issued 17 April 2003
Resolved
Remove dead-ended PVC pipe, starboard side, in the forward bulkhead of the engine room. 46CFR182.710
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner removed dead-ended PVC pipe, starboard side, in the forward bulkhead of the engine room. 46CFR182.710
Engineering › Fuel Oil Service System
Issued 17 April 2003
Resolved
Remove fuel filter & associated piping for the ship's service generator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 17 April 2003
Resolution: Fuel piping for generator removed and supply lines properly plugged.
Engineering › Steering Gear System
Issued 17 April 2003
Resolved
Replace non-metalic hose for hydraulic fluid supply on the steering system, starboard side per 46 CFR 182.720. LEGACY COMPONENT DESC: Hydraulic Hose
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner replaced non-metalic hose for hydraulic fluid supply on the steering system, starboard side per 46 CFR 182.720.
Engineering › Steering Gear System
Issued 17 April 2003
Resolved
Mount hydraulic lines in the starboard side of the engine room, aft, leading to the fuel tank/lazarrette space. 46CFR182.710. LEGACY COMPONENT DESC: Hydraulic Hose
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner mounted hydraulic lines in the starboard side of the engine room, aft, leading to the fuel tank/lazarrette space. 46CFR182.710.
Engineering › Steering Gear System
Issued 17 April 2003
Resolved
Remove dead-ended hydraulic lines on the starboard side of the fuel tank/lazarrette space.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner removed dead-ended hydraulic lines on the starboard side of the fuel tank/lazarrette space.
Construction/Loadline › Penetrations
Issued 17 April 2003
Resolved
Repair leak on the starboard exhaust pipe located in the lazarrette. 46CFR179.350
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 17 April 2003
Construction/Loadline › Hull
Issued 17 April 2003
Resolved
Re-fasten sideshell to the floorboards located in the lazarrette.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner re-fastened sideshell to the floorboards located in the lazarrette.
Engineering › Steering Gear System
Issued 17 April 2003
Resolved
Replace cotter pin on the port side rudder assembly. 46CFR182.610
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner replaced cotter pin on the port side rudder assembly. 46CFR182.610
Electrical › Electrical Distribution System (service)
Issued 17 April 2003
Resolved
Provide supports for cooling line on the port engine where hanging on port solenoid.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided supports for cooling line on the port engine where hanging on port solenoid.
Electrical › Electrical Distribution System (service)
Issued 17 April 2003
Resolved
Provide cable clamps for all wires and cable in the engine room and bilges throughout the vessel. 46 CFR 183.340.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided cable clamps for all wires and cable in the engine room and bilges throughout the vessel. 46 CFR 183.340.
Electrical › Electrical Distribution System (service)
Issued 17 April 2003
Resolved
Remove dead-ended wiring in the engine room. 46 CFR 183.340
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner removed dead-ended wiring in the engine room. 46 CFR 183.340
Electrical › Lighting (service)
Issued 17 April 2003
Resolved
Remove lamp assembly located in the overhead of the forward part of the engine room. 46CFR183.340
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner removed lamp assembly located in the overhead of the forward part of the engine room. 46CFR183.340
Communications › Alarms/Indicators
Issued 17 April 2003
Resolved
Remove old float switch located in the forward bilge of the engine room. LEGACY COMPONENT DESC: Bilge Alarm
Due 17 May 2003
Resolved 17 April 2003
Electrical › Electrical Distribution System (service)
Issued 17 April 2003
Resolved
Replace non-approved electrical wiring with UL approved boat cable. 46 CFR 183.340.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner replaced non-approved electrical wiring with UL approved boat cable. 46 CFR 183.340.
Electrical › Electric Generation Source (service)
Issued 17 April 2003
Resolved
Provide cover & proper mounting for the port battery. 46CFR183.354
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided cover & proper mounting for the port battery. 46CFR183.354
Electrical › Electrical Distribution System (service)
Issued 17 April 2003
Resolved
Replace the wiring leading to the motor for the sewage pump.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner replaced the wiring leading to the motor for the sewage pump.
Electrical › Electric Generation Source (service)
Issued 17 April 2003
Resolved
Disconnect & terminate all piping for the ship's service generator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 17 April 2003
Operations/Management › Drills/Instruction
Issued 17 April 2003
Resolved
Complete underway checks, man-overboard, & fire drill
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2003
Resolved 17 April 2003
Resolution: U/w checks sat.
Engineering › Bilge Water Management System
Issued 17 April 2003
Resolved
Permanently mount submersible bilge pump located in the cabin. 46CFR182.520 LEGACY COMPONENT DESC: Pump
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner permanently mount submersible bilge pump located in the cabin. 46CFR182.520
Communications › Alarms/Indicators
Issued 17 April 2003
Resolved
Provide independant smoke detectors for cabin & accomodations spaces per 46CFR182.520(c) LEGACY COMPONENT DESC: Fire Alarm
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner provided independant smoke detectors for cabin & accomodations spaces per 46CFR182.520(c)
Engineering › Diesel Engine (propulsion-direct drive)
Issued 17 April 2003
Resolved
Replace support strap for starboard exhaust.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner replaced support strap for starboard exhaust.
Lifesaving › Lifejacket/PFD (General)
Issued 17 April 2003
Resolved
Mark lifejacket stowage box to reflect location. LEGACY COMPONENT DESC: Storage
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner marked lifejacket stowage box to reflect location.
Lifesaving › Buoyant Apparatus
Issued 17 April 2003
Resolved
Permanently mount lifefloat.
Due 17 May 2003
Resolved 21 May 2003
Resolution: Owner permanently mounted lifefloat.
Fire Fighting › Fixed Fire Detection System
Issued 15 May 2002
Resolved
Renew smoke detectors in berthing area, in accordance with 46CFR141.400 prior to carriage of passengers on an overnight trip. LEGACY COMPONENT DESC: Smoke Detectors
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2002
Resolved 7 June 2002
Lifesaving › Buoyant Apparatus
Issued 15 May 2002
Resolved
Replace lifefloat weak link with one appropriately sized in accordance with 46CFR180.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 22 June 2002
Resolved 23 May 2002
Stability › Watertight Integrity
Issued 15 May 2002
Resolved
Properly attach aft deck and forepeak hatches in accordance with 46CFR171.
Action required: 705 - Other - as specified
Due 22 June 2002
Resolved 7 June 2002
Engineering › Steering Gear System › Ram
Issued 15 May 2002
Resolved
Prior to carrying passengers, properly refasten steering ram shim.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 May 2002
Engineering › Steering Gear System
Issued 15 May 2002
Resolved
Tighten port and starboard rudder shaft packing. LEGACY COMPONENT DESC: Rudder Bearing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2002
Resolved 7 June 2002
Fire Fighting › Miscellaneous Items
Issued 15 May 2002
Resolved
By 01JUN02, service fixed and portable fire extinguishers, after which vessel may not carry more than six passengers unless systems have been serviced.
Due 1 June 2002
Resolved 7 June 2002
Communications › Radio Communications
Issued 15 May 2002
Resolved
Renew EPIRB battery no later than 01JUN02, else vessel is restricted to 3 miles from land. LEGACY COMPONENT DESC: EPIRB
Due 1 June 2002
Resolved 7 June 2002
Electrical › Electrical Distribution System (service)
Issued 15 May 2002
Resolved
Replace switchboard cover. LEGACY COMPONENT DESC: Switchboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 June 2002
Resolved 7 June 2002
Communications › Radio Communications
Issued 15 May 2002
Resolved
Obtain and affix on vessel an emergency broadcast placard required by 46CFR184.506. LEGACY COMPONENT DESC: VFH Radiotelephone
Action required: 705 - Other - as specified
Due 22 June 2002
Resolved 7 June 2002
Lifesaving
Issued 10 May 2001
Resolved
PRIOR TO CARYING PASSENGERS, RENEW EPIRB HYDROSTATIC RELEASE, AS REQUIRED BY 46CFR180.64.
Condition: Unknown
Due 9 June 2001
Resolved 12 July 2001
Lifesaving
Issued 10 May 2001
Resolved
PLACE VESSEL'S NAME ON INDICATED PFDs IN ACCORDANCE WITH 46CFR185.604.
Condition: Unknown
Due 9 June 2001
Resolved 12 July 2001
Construction/Loadline
Issued 10 May 2001
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, INSTALL BILGE HIGH LEVEL ALARMS REQUIRED BY 46CFR182.530.
Condition: Unknown
Due 9 June 2001
Resolved 12 July 2001
Engineering
Issued 10 May 2001
Resolved
PROVIDE MACHINERY GUARD ON PORT MDE IN ACCORDANCE WITH 46CFR177.960.
Condition: Unknown
Due 9 June 2001
Resolved 12 July 2001
Fire Fighting
Issued 10 May 2001
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, DEMONSTRATE PROOF OF ANNUAL SERVICE FOR FIXED FIRE FIGHTING SYSTEM, PER 46CFR176.810.
Condition: Unknown
Due 9 June 2001
Resolved 12 July 2001
Lifesaving
Issued 10 May 2001
Resolved
RENEW RETRO TAPE ON INDICATED PFDs IN ACCORDANCE WITH 46CFR SUBCHAPTER Q.
Condition: Unknown
Due 9 June 2001
Resolved 12 July 2001
Lifesaving
Issued 10 May 2001
Resolved
PRIOR TO CARRIAGE OF PASSENGERS, PROVIDE ON BOARD DISTRESS SIGNALS REQUIREDBY 46CFR180.68.
Condition: Unknown
Due 9 June 2001
Resolved 12 July 2001
Lifesaving
Issued 10 May 2001
Resolved
RENEW RING LIFE BUOY REQUIRED BY 46CFR180.70 PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 9 June 2001
Resolved 12 July 2001
Lifesaving
Issued 10 May 2001
Resolved
PRIOR TO CARRIAGE OF PASSENGERS ON OVERNIGHT VOYAGES, PROVIDE SMOKE DETECTORS IN ACCOMODATION SPACES PER 46CFR181.450.
Condition: Unknown
Due 9 June 2001
Resolved 12 July 2001
Lifesaving
Issued 16 April 1998
Resolved
RETRO TAPE ON BOUYANT APPARATUS DETERIORATED._x001C_
Condition: Unknown
Due 16 April 1998
Resolved 19 April 1998
Lifesaving
Issued 16 April 1998
Resolved
SIX HAND HELD FLARES EXPIRED_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 April 1998
Resolved 16 April 1998
Lifesaving
Issued 16 April 1998
Resolved
RETRO REFLECTIVE TAPE ON RING BOUY DETERIORATED.
Condition: Unknown
Due 16 April 1998
Resolved 19 April 1998
Documentation
Issued 16 April 1998
Resolved
FCC RADIO SAFETY CERTIFICATE EXPIRED.
Condition: Unknown
Due 16 April 1998
Resolved 19 April 1998
Engineering
Issued 16 April 1998
Resolved
NO FUEL SHUT OFF VALVES LOCATED BETWEEN ACCESORIES AND MAIN ENGINES.
Condition: Unknown
Due 16 April 1998
Resolved 19 April 1998
Electrical
Issued 16 April 1998
Resolved
GENERATOR MISSING GENERATOR SPECIFICATION PLATE MISSING.
Condition: Unknown
Due 16 April 1998
Resolved 19 April 1998
Lifesaving
Issued 16 April 1998
Resolved
EPIRB DID NOT PASS A SATISFACTORY TEST.
Condition: Unknown
Due 16 April 1998
Resolved 19 April 1998
Navigation
Issued 16 April 1998
Resolved
NO CURRENT CHARTS OR NAVIGATION INFORMATION OBOARD.
Condition: Unknown
Due 16 April 1998
Resolved 19 April 1998
Electrical
Issued 16 April 1998
Resolved
VOLTAGE AND FREQUENCY METERS ARE LOOSE IN THEIR MOUNTINGS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 April 1998
Resolved 19 April 1998
Engineering
Issued 31 July 1997
Resolved
PROVIDE FUEL CUTOUT VALVES AT GENERATOR AS PER 46 CFR 182.455(B)(4).
Condition: Unknown
Due 1 September 1997
Resolved 6 October 1997
Engineering
Issued 31 July 1997
Resolved
REPAIR AND DEMONSTRATE OPERATION OF STBD PROPULSION ENGINE REMOTE START/STOP.
Condition: Unknown
Due 1 September 1997
Resolved 6 October 1997
Engineering
Issued 31 July 1997
Resolved
PROVIDE REMOTE FUEL CUT OUT VALVE FOR FUEL SUPPLY TO GENERATOR AT FUEL TANK46 CFR 182.455(B)(4)
Condition: Unknown
Due 1 September 1997
Resolved 6 October 1997
Construction/Loadline
Issued 11 April 1995
Resolved
MAKE AFT MAINDECK HATCH WATER TIGHT.
Condition: Unknown
Due 6 May 1995
Resolved 29 May 1995
Navigation
Issued 11 April 1995
Resolved
PROVIDE PROPER SIZE BELL IAW 72 COLREGS ANNEX III
Condition: Unknown
Due 6 May 1995
Resolved 29 May 1995
Lifesaving
Issued 11 April 1995
Resolved
RENEW RETRO TAPE ON 1 ADULT PFD AND 1 CHILD PFD AS MARKED.
Condition: Unknown
Due 6 May 1995
Resolved 29 May 1995
Construction/Loadline
Issued 11 April 1995
Resolved
RENEW DECAYED MAINDECK IN FORPEAK.
Condition: Unknown
Due 23 April 1995
Resolved 29 May 1995
Documentation
Issued 11 April 1995
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 May 1995
Resolved 29 May 1995
Documentation
Issued 11 April 1995
Resolved
POST ALL LICENSE'S AND DOCUMENTS.
Condition: Unknown
Due 6 May 1995
Resolved 29 May 1995
Accommodation/Occupational Safety
Issued 1 April 1992
Resolved
REMOVE OR PROVE BY TEST ALL TINTED PILOT HOUSE WINDOWS THAT NO MORE THAN 20% LIGHT TRANSMISSIONS IS BLOCKED OUT.
Condition: Unknown
Due 1 April 1992
Resolved 10 April 1992
Construction/Loadline
Issued 6 November 1991
Resolved
RECAULK ALONG STERN DECK HATCH FRAME AND PROVE WATERTIGHTNESS OF HATCH COVER AND FRAME WITH THIRTY PSI OF WATER PRESSURE._x001C_ _x001C_ X
Condition: Unknown
Due 13 November 1991
Resolved 27 November 1991
Construction/Loadline
Issued 6 November 1991
Resolved
RENEW WORM DAMAGED SHOE APPROXIMATELY THREE FT AFT OF STEM._x001C_
Condition: Unknown
Due 13 November 1991
Resolved 27 November 1991
Construction/Loadline
Issued 6 November 1991
Resolved
RENEW BASKET STRAINER TO PORT MAIN DIESEL ENGINE SEA SUCTION STRAINER ASSEMBLY._x001C_
Condition: Unknown
Due 13 November 1991
Resolved 27 November 1991
Construction/Loadline
Issued 6 November 1991
Resolved
REPAIR LOOSE MOUNTING FOR STEERING SYSTEM HYDRAULIC RAM._x001C_
Condition: Unknown
Due 13 November 1991
Resolved 27 November 1991
Engineering
Issued 20 March 1991
Resolved
REPLACE FLEX HOSE FOR PORT MAIN DIESEL ENGINE RAW WATER SUCTION
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Engineering
Issued 20 March 1991
Resolved
REMOVE EXISTING RACOR FUEL FILTER AND INSTALL FUEL FILTER THAT ARE U/L APPROVED FOR MARINE USE.
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Engineering
Issued 20 March 1991
Resolved
PROVIDE A SUITABLE WARNING DEVICE TO INDICATE ANY FAILURE OF WATER FLOW IN THE EXHAUST SYSTEM
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Lifesaving
Issued 20 March 1991
Resolved
RENEW WATER LIGHT LINE OF AT LEAST 18FT TO BOUYANT APPARATUS
Condition: Unknown
Due 20 March 1991
Resolved 20 March 1991
Unknown
Issued 31 May 1988
Resolved
TIGHTEN AND OR RE-PACK AS NECESSARY: A) BOTH RUDDER PACKING TUBES B) PORT TAILSHAFT PACKING TUBE
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Unknown
Issued 31 May 1988
Resolved
REMOVE WATER FROM FORE PEAK AND MAKE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Unknown
Issued 31 May 1988
Resolved
REPAIR BUOYANT APPARATUS LIFE LINE BRACKETS OR PROVIDE NEW BUOYANT APP OR LIFE FLOAT.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Unknown
Issued 31 May 1988
Resolved
PROVIDE PROPER SIZED WEAK LINK FOR B. APP.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Unknown
Issued 31 May 1988
Resolved
RECHARGE 1 EMPTY B - II FIRE EXT. (DRY CHEM.)
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Unknown
Issued 31 May 1988
Resolved
PROVIDE PROPER BRACKET FOR CABIN FIRE EXT.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Unknown
Issued 31 May 1988
Resolved
PROVIDE WATERTIGHT BOX FOR FLARES.
Condition: Unknown
Due 31 May 1988
Resolved 31 May 1988
Documentation
Issued 2 June 1987
Resolved
PROVIDE FCC: A) STATION LICENSE B) SAFETY CERTIFICATE
Condition: Unknown
Due 2 June 1987
Resolved 2 June 1987