MAURY USCG vessel records Sign in
← All vessels

DIXILYN FIELD 76

DIXILYN FIELD 76 is a 1957 mobile offshore drilling unit. The Coast Guard has recorded 17 inspections since 1981, most recently in August 1987, along with 57 deficiencies.

Records from 1981 to 1987. Most recent: inspection, 18 August 1987.

Built
1957
Last inspected
18 August 1987
Documentation
Invalid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-52947

Inspections, by type

…with no type recorded12
Years with a record 7 calendar years (1981–1987)
The 17 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 39 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Registered dimensions (L × B × D)181.0 ft × 151.0 ft × 11.4 ft
Registered tonnagegross 2,372 / net 2,105
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilt 1957
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNot recorded
Trade endorsementsNot recorded
DocumentationInvalid
Service, as the file records itMobile Offshore Drilling Unit
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it2105 - Regulatory (Subpart C or D), Net Ton
2372 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 17

18 August 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1029306
28 April 1986 Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 985505
27 November 1985 Examination of Repairs · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993499
4 November 1985 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993758
1 November 1985 Damage Survey
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 994430
10 October 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1299467
28 August 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 987972
1 June 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287788
10 April 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 980379
24 May 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973338
28 July 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275543
14 June 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963547
10 May 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964908
2 June 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277640
10 May 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271715
27 April 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966189
10 May 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 964337

Deficiency record · 57

Unknown
Issued 28 April 1986 Resolved
COMPLET WORKLIST ISSUED 28APR86 DURING MID-PERIOD EXAM PRIOR TO STACKING. WORKLIST TO BE COMPLETED PRIOR TO LEAVING MOBILE, AL, TO THE SATISFACTION OF THE [name withheld], AL.
Condition: Unknown
Due 1 January 1999
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 27 November 1985 Resolved
PROVIDE ACCESS AND CLEAN THE WELDS FOR EXAMINATION BY A COAST GUARD INSPECTOR. THE MAIN DECK FORE AND AFT FRAMING IN WAY OF THE CELLAR DECK 46CFR231. COMPLIANCE DATE IS 27DEC85.
Condition: Unknown
Due 17 January 1986
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 4 November 1985 Resolved
REPAIR REVERSE POWER TRIP FOR #1 AND #2 SHIP SERVICE MAIN GENERATORS REF 46CFR 111.12-11
Condition: Unknown
Due 4 November 1985
Resolved 4 November 1985
Electrical
Issued 4 November 1985 Resolved
REPAIR THE LOW LUBE OIL AND HIGH TEMP ALARM ON THE #1 #2 AND #3 MAIN GENERATOR DRIVE ENGINES, REF 46 CFR 58.10
Condition: Unknown
Due 4 November 1985
Resolved 4 November 1985
Construction/Loadline
Issued 1 November 1985 Resolved
DRYDOCK THE RIG UPON MOVING FROM CURRENT DRILLING SITE TO MAKE PERMANENT REPAIRS TO THE LOWER HULL.
Condition: Unknown
Due 1 November 1985
Resolved 1 November 1985
Construction/Loadline
Issued 1 November 1985 Resolved
MAKE TEMPORARY REPAIRS TO THE FORWARD BULKHEAD HULL PLATING IN THE PUMPROOMADJACENT TO 20.2 BALLAST TANK.
Condition: Unknown
Due 1 November 1985
Resolved 1 November 1985
Construction/Loadline
Issued 1 November 1985 Resolved
PROVIDE THICKNESS GAGING REPORT FOR THE BULKHEAD BETWEEN THE PUMPROOM AND 20.1 BALLAST TANK PRIOR TO COMPLETING PERMANENT REPAIRS TO THE LOWER HULL.
Condition: Unknown
Due 1 November 1985
Resolved 1 November 1985
Construction/Loadline
Issued 10 October 1985 Resolved
REMOVE OIL FROM PUMP ROOM BILGE.
Condition: Unknown
Due 10 October 1985
Resolved 10 October 1985
Documentation
Issued 10 October 1985 Resolved
PROVIDE A VALID SHIP RADIO STATION LICENSE ON BOARD VESSEL.
Condition: Unknown
Due 10 October 1985
Resolved 10 October 1985
Electrical
Issued 1 June 1985 Resolved
REPAIR REVERSE POWER TRIP FOR #1 AND #2 SHIP SERVICE MAIN GENERATORS REF 46CFR 11.12-11.
Condition: Unknown
Due 1 June 1985
Resolved 1 June 1985
Electrical
Issued 1 June 1985 Resolved
REPAIR THE LOW LUBE OIL AND HIGH TEMP ALARM ON THE #1 AND #3 MAIN GENERATORDRIVE ENGINES, REF 46 CFR 58.10.
Condition: Unknown
Due 1 June 1985
Resolved 1 June 1985
Unknown
Issued 1 June 1985 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL DIXILYN FIELD 76 CG000002
Condition: Unknown
Due 1 June 1985
Resolved 1 June 1985
Fire Fighting
Issued 24 May 1984 Resolved
PROVIDE ONE 10 FOOT FOG APPLICATOR FOR EACH FIRE HOSE USED FOR HELO-DECK PROTECTION. 46 CFR 108.425(D)2.
Condition: Unknown
Due 24 May 1984
Resolved 24 May 1984
Unknown
Issued 24 May 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESESEL, DIXILYN FIELD 76, CG000002
Condition: Unknown
Due 24 May 1984
Resolved 24 May 1984
Fire Fighting
Issued 24 May 1984 Resolved
PROVIDE TWO OXYGEN METERS AND ONE EXPLOSIVE METER (U/L OR F/M APPROVED) 46 CFR 108.499(C).
Condition: Unknown
Due 24 May 1984
Resolved 24 May 1984
Lifesaving
Issued 24 May 1984 Resolved
PROVIDE MARKINGS ON ALL LIFE FLOATS IN ACCORDANCE WITH 33 CFR 146.135. SEE NVC 4-78.
Condition: Unknown
Due 24 May 1984
Resolved 24 May 1984
Lifesaving
Issued 24 May 1984 Resolved
MARK RINGBUOYS WITH RIG NAME, AS NEEDED. 46 CFR 108.649.
Condition: Unknown
Due 24 May 1984
Resolved 24 May 1984
Lifesaving
Issued 24 May 1984 Resolved
REALIGN HAND CRANK ASSEMBLY AND REPLACE THE OPERATING DRIVE BELT FOR NO.2 CAPSULE DAVIT. 46 CFR 108.507.
Condition: Unknown
Due 24 May 1984
Resolved 24 May 1984
Lifesaving
Issued 24 May 1984 Resolved
REPLACE THE OUTSIDE LIFELINE ON THE NO. 2 CAPSULE. 46 CFR 108.503.
Condition: Unknown
Due 24 May 1984
Resolved 24 May 1984
Unknown
Issued 24 May 1984 Resolved
PROVIDE PRESSURE GAUGES ON BOTH FIRE PUMPS DISCHARGE SIDES. 46 CFR 108.417(B).
Condition: Unknown
Due 24 May 1984
Resolved 24 May 1984
Fire Fighting
Issued 24 May 1984 Resolved
INSURE THAT ALL FIRE HOSE STATIONS ARE EQUIPPED IN ACCORDANCE WITH APPROVEDFIRE CONTROL PLAN. 46 CFR 108.423 AND 46 CFR 108.425.
Condition: Unknown
Due 24 May 1984
Resolved 24 May 1984
Fire Fighting
Issued 24 May 1984 Resolved
HYDROSTATICALLY TEST AND SERVICE ALL A/R PACK BOTTLES WITH HYDRO DATES OF 5/79 OR EARLIER. 46 CFR 160.01
Condition: Unknown
Due 24 May 1984
Resolved 24 May 1984
Unknown
Issued 24 May 1984 Resolved
MAKE SEA CHEST AND SEA VALVES AVAILABLE FOR INSPECTION. THIS ITEM TO BE COMPLETED AT NEXT RIG MOVE OR 19SEP84 WHICH EVER COMES FIRST.
Condition: Unknown
Due 24 May 1984
Resolved 24 May 1984
Electrical
Issued 24 May 1984 Resolved
PROVIDE EMERGENCY LIGHTING FOR BOTH CAPSULE SATIONS TO PROVIDE ILLUMINAT- ION OF THE WATER AND BOAT AT THE LOWERED POSITION. 46 CFR 111.75-15(E)
Condition: Unknown
Due 24 May 1984
Resolved 24 May 1984
Unknown
Issued 10 May 1983 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL DIXILYN FIELD RIG 76, CG000002.
Condition: Unknown
Due 10 May 1983
Resolved 10 May 1983
Fire Fighting
Issued 10 May 1983 Resolved
PROVIDE MARINE BRACKETS FOR ALL PORTABLE EXTINGUISHERS.
Condition: Unknown
Due 10 May 1983
Resolved 10 May 1983
Lifesaving
Issued 10 May 1983 Resolved
REPLACE TORN DRIVE BELT ON NO. 1 CAPSULE WINCH.
Condition: Unknown
Due 10 May 1983
Resolved 10 May 1983
Unknown
Issued 10 May 1983 Resolved
PROVIDE LOAD CHART TO STARBOARD CRANE.
Condition: Unknown
Due 10 May 1983
Resolved 10 May 1983
Electrical
Issued 10 May 1983 Resolved
MAKE OVERSPEED TRIPS OPERABLE ON ALL GENERATORS. OPERATION TO BE DEMONSTRA-TED TO COAST GUARD INSPECTOR. HAND TACHOMETER TO BE PROVIDED FOR INSPECTION
Condition: Unknown
Due 10 May 1983
Resolved 10 May 1983
Electrical
Issued 10 May 1983 Resolved
MAKE JUNCTION BOX ABOVE MUD HOPPER SUITABLE FOR CLASSIFIED LOCATION.
Condition: Unknown
Due 10 May 1983
Resolved 10 May 1983
Electrical
Issued 10 May 1983 Resolved
MAKE JUNCTION BOX (THYAC RESISTOR) ABOVE EACH MUD PUMP MOTOR SUITABLE FOR CLASSIFIED LOCATION.
Condition: Unknown
Due 10 May 1983
Resolved 10 May 1983
Unknown
Issued 10 May 1983 Resolved
REPAIR/REPLACE MOTOR CONTROLLED BALLAST VALVES NO. 12 AND NO. 13.
Condition: Unknown
Due 10 May 1983
Resolved 10 May 1983
Electrical
Issued 10 May 1983 Resolved
MAKE REVERSE POWER TRIP OPERABLE ON NO. 3 AC GENERATOR.
Condition: Unknown
Due 10 May 1983
Resolved 10 May 1983
Navigation
Issued 10 May 1982 Resolved
PROVIDE NAVIGATIONAL LIGHTS AND SIGNALS FOR NOT UNDER COMMAND.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Navigation
Issued 10 May 1982 Resolved
CLEAN AND LEVEL OBSTRUCTION LIGHTS.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Unknown
Issued 10 May 1982 Resolved
PROVIDE CONTAINMENT FOR FUEL OIL.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
PROVIDE COVERS FOR BUNK LIGHTS.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
INSTALL MISSING EYS SEALS ON MUD CLEANER
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
MAKE SOUND POWERED PHONE IN MUD PIT AREA SUITABLE FOR INSTALLATION IN A CLASSIFIED AREA AS REQUIRED BY 46 CFR 111.80.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
REPLACE MISSING COVER ON MUD MIXER MOTOR TERMINAL (RESERVE PIT)
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
PROVIDE BLANK COVERS FOR MISSING CIRCUIT BREAKERS IN TWO POWER PANELS IN MOTOR ROOM.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
SECURE COVER TO ELEVATOR SWITCH BOX.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Lifesaving
Issued 10 May 1982 Resolved
CLEAN TWO FIFTEEN (15) MAN LIFEFLOATS ON STERN (#1 & #2). PROVIDE BRACKET FOR LIGHT ON #4 LIFEFLOAT.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Lifesaving
Issued 10 May 1982 Resolved
REPLACE MISSING LIGHTS AND WHISTLE ON LIFE JACKETS.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Lifesaving
Issued 10 May 1982 Resolved
CLEAN LINE TROWING GUN AND PROVIDE 25 CARTRIGES AND 10 PROJECTILES.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
MARK QUARTERS VENTILATION SHUTDOWN AS REQUIRED BY 46 CFR 111.80-10,13
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
PROVIDE REMOTE SHUTDOWNS FOR FUEL OIL TRANSFER PUMP, MACHINERY SPACE VENTILATION, AND QUARTERS VENTILATION AS REQUIRED BY 46 CFR 111.80-10,13
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Deck/Cargo
Issued 10 May 1982 Resolved
REPLACE OR REPAIR VALVES MV 14, 15, 16.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
REPLACE MISSING GENERAL ALARM BELL IN UPPER QUARTERS PASSAGE WAY.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
REPLACE OR REPAIR INOPERATIVE GENERAL ALARM BELL IN PUMPROOM.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
REPLACE MISSING COVERS ON ELECTRICAL JUNCTION BOXES 2 IN PUMP ROOM, 2 IN MOTOR ROOM.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Lifesaving
Issued 10 May 1982 Resolved
RECHARGE DISCHARGED AIR BOTTLE IN AIR PACK IN PUMPROOM.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
MAKE INTERCOMS IN MUD PIT AND SHALE SHAKER AREAS SUITABLE FOR INSTALLATION IN A CLASSIFIED AREA.
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Electrical
Issued 10 May 1982 Resolved
REMOVE NON-EXPLOSION PROOF EQUIPMENT AND EXTENSION CORDS FROM SHALE SHAKER AREA
Condition: Unknown
Due 10 May 1982
Resolved 10 May 1982
Lifesaving
Issued 27 April 1982 Resolved
REPLACE RING BUOYS THROUGHOUT RIG AND PERMANENTLY MOUNT WATER LIGHT BRACKETS.
Condition: Unknown
Due 27 April 1982
Resolved 27 April 1982
Electrical
Issued 27 April 1982 Resolved
REMOVE PLASTIC TIE WRAPS ON WIRES AT DRILL FLOOR AND OVER MUD PUMPS.
Condition: Unknown
Due 27 April 1982
Resolved 27 April 1982
Electrical
Issued 27 April 1982 Resolved
REPAIR OR REPLACE EMERGENCY BATTERY LANTERNS.
Condition: Unknown
Due 27 April 1982
Resolved 27 April 1982