Records from 2009 to 2026. Most recent: inspection, 6 July 2026.
Inspection history · 24
6 July 2026
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8430410
18 November 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8249938
29 May 2025
Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8146925
18 November 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8027856
3 September 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7995464
15 November 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7804637
7 November 2023
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7807636
1 May 2023
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7674681
7 September 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7555228
23 August 2022
Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7517733
10 March 2022
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7407392
16 November 2021
Annual Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7336570
16 March 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7157120
11 August 2020
DAPI Audit · Permit to Proceed · MTSA Verification · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6984072
28 July 2020
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7030772
22 May 2020
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6955452
19 November 2019
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6848835
14 November 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6566343
5 September 2018
Deficiency Check · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6532718
28 August 2018
Drydock Exam · Deficiency Check · Administrative Inspection · Examination of Repairs · Permit to Proceed
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6499217
15 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6512783
29 August 2017
Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6173753
1 November 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6009648
19 July 2016
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5945574
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2024
Resolved
At each inspection the marine inspector shall inspect all life saving equipment to determine its servicability.
03 liferings had damaged or faded retro reflective tape. Replace retro on each ring to the satisfaction of the Coast Guard.
46CFR176.25-22
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2024
Resolved 22 November 2024
Resolution: Replaced life ring retro, SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 November 2024
Resolved
fuel system to include tanks, vents, piping, and fittings.
The centerline generator fuel line, going into the raycor filter was found chaffed. Replace fuel line to the Coast Guards satisfaction.
46 CFR 176.25-10
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2024
Resolved 22 November 2024
Resolution: Replaced fuel hose, SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 November 2024
Resolved
At each inspection the marine inspector shall examine fuel system to include tanks, vents, piping, and fittings.
A fuel leak was found on the port propulsion engine leaking onto the exhaust manifold. This was a loose fitting that was corrected on the spot.
46 CFR 176.25-10
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 November 2024
Resolved 18 November 2024
Resolution: Tightened leaking fitting.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 November 2024
Resolved
150 passengers, shall meet the requirements of subpart 72.05 subchapter H.
01 fire door was not closing. Adjustments were made and the door was operating properly before inspection completion.
46 CFR 177.10-5
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 November 2024
Resolved 18 November 2024
Resolution: Adjustments were made. Operation SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 November 2024
Resolved
At each inspection the marine inspector shall examine electrical systems to ensure they are in operating condition.
The emergency lighting system did not activate upon power failure. A switch for the emergency light systems located under the console in the pilothouse was off. One energized, the emergency light system functioned properly.
46 CFR 176.25-15
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 18 November 2024
Resolved 18 November 2024
Resolution: Energized system. Tests were SAT.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 23 August 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks.
In Laz space, identified corrosion on stringer/bulkhead/deck plate on fwd port side along with fractured weld from tripping bracket to stiffener aft port side. On deck 1 transom, identified 3" diameter hole.
46 CFR 176.20-1
Action required: 705 - Other - as specified
Due 30 September 2022
Resolved 29 September 2022
Resolution: Replaced tripping bracket and installed doubler for 3" diameter hole discovered between galley vents on stern.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 August 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including: (a) Operation of the main propulsion machinery both ahead and astern.
Port M/E has exhaust leak and is not gas tight.
46 CFR 182.20-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2022
Resolved 29 September 2022
Resolution: Exhaust pipe rewelded and gas tight.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in charge, Marine Inspection.
Pilothouse DC system fuses are missing labels.
46 CFR (Old T)183.01-15
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2022
Resolved 6 September 2022
Resolution: Received photo of DC system with fuse labels.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.
Pilothouse AC distribution system breaker is missing a label for the marine radar.
46 CFR (Old T)183.01-15(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 September 2022
Resolved 6 September 2022
Resolution: Marine radar breaker labeled.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 August 2022
Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation.
Remote fuel shutoff valve not easily marked/identified.
46 CFR (Old T)185.30-20
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2022
Resolved 6 September 2022
Resolution: Fuel shutoff valve painted red and labeled.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 23 August 2022
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected.
Tripping hazard identified on main deck by port/stbd
galley/service entry.
46 CFR (Old T)176.25-50
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 September 2022
Resolved 6 September 2022
Resolution: Tripping hazard ledge painted white.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 November 2018
Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters at least 25 millimeters 1 inch high. MI found markings on watertight door non-legible, mark door to the satisfaction of attending MI.
46 CFR 122.610
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 November 2018
Resolved 26 November 2018
Resolution: Door properly marked, deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2018
Resolved
Deficiency code 13199
Starboard side propeller has a cracked blade, show suitable service condition to attending marine inspector. 46CFR115.840
Action 705c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 September 2018
Resolved 25 September 2018
Resolution: Both props were sent in for sent for repair and came back satisfatory and blue fitted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2018
Resolved
Deficiency code 13199
Both propellers shaft need to be pulled out for further
inspection by the Marine Inspector. 46CFR115.670(a)
Action 705c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2018
Resolved 25 September 2018
Resolution: Both Shafts were pulled and had excessive pitting, both shafts were reconditioned to the satisfaction of the MI
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 August 2018
Resolved
Deficiency code 02112
Lazzarette, UT Shot deck plate under watertight hatch area, show proper material thickness to attending marine inspector satisfaction. 46CFR115.700(d)
Action 705c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2018
Resolved 25 September 2018
Resolution: UT shots showed exessive wear and was cropped and renewed see repair plan, insert was approved and water tested.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 August 2018
Resolved
Deficiency code 02107
Found holes on top sewage tank, repair to attending marine inspector satisfaction. 46CFR115.800(a)
Action 705 c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2018
Resolved 25 September 2018
Resolution: UT shot showed exessvie watage, see repair plan in documents. insert was approved and witnessed water test in the presence of CG inspector.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 August 2018
Resolved
Deficiency code 03112
Lazzarette s/side thru hull piping needs to be replaced,
replace to attending marine inspector atisfaction. 46CFR115.700(d)
Action 705 c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2018
Resolved 25 September 2018
Resolution: Overboard for sewage was replaced with new screen. MI accepted new installations
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 August 2018
Resolved
Deficiency code 02112
UT shot, engine Room port side under main fire pump,
show proper material thickness to attending marine
inspector. 46CFR115.700(d)
Action 705 c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2018
Resolved 25 September 2018
Resolution: UT shot showed exessvie watage, see repair plan in documents. insert was approved and witnessed water test in the presence of CG inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 August 2018
Resolved
Deficiency code 02112
UT shot, engine room under watertight door to water
room, show proper material thickness to attending marine
inspector. 46CFR115.700(d)
Action 705 c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2018
Resolved 25 September 2018
Resolution: UT shot showed exessvie watage, see repair plan in documents. insert was approved and witnessed water test in the presence of CG inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 August 2018
Resolved
Deficiency code 02112
UT shot, starboard side water room aft and bow, show
proper material thickness to attending marine inspector. 46CFR115.700(d)
Action 705 c
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 August 2018
Resolved 25 September 2018
Resolution: UT shot showed exessvie watage, see repair plan in documents. insert was approved and witnessed water test in the presence of CG inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2018
Resolved
Bilge pipes under valves at engine room, replace bad pipes and submit working plan in order to replace flex hoses. - 46CFR119.510
Action required: 10 - Deficiency Rectified
Resolved 4 September 2018
Resolution: Repair proposal accepted, replaced piping in question.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2018
Resolved
Engine room aft, starboard side and port side insulation needs to be refreshed. - 46CFR116.415(a)(2)(i)
Action required: 10 - Deficiency Rectified
Resolved 4 September 2018
Resolution: Insulation refreshed to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2018
Resolved
Found a hole in bilge pipe in the liquor room. - 46CFR119.510
Action required: 10 - Deficiency Rectified
Resolved 4 September 2018
Resolution: Repair proposal accepted and pipe replaced.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018
Resolved
Vsl is broadcasting: Greater/smaller than expected vessel length and no dimension information (AIS Antenna Position ABCD values equals 0).
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 19 November 2019
Resolution: AIS verified by MI for proper info, SAT.
Engineering › Bilge Water Management System › Strainer
Issued 29 August 2017
Resolved
Repair fuel supply space and machinery space bilge suction units. 46CFR182.25-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 30 August 2017
Resolution: Tested bilge suction, all sat.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 29 August 2017
Resolved
Repair door on third deck of stairwell. 46CFR116.435
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2017
Resolved 29 August 2017
Resolution: Repaired door on 3rd deck readjusting.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 1 November 2016
Resolved
Ensure fire doors fully self close on main and 3rd deck. 46 CFR 116.435
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 1 November 2016
Resolution: Fire doors fully self close.
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 1 November 2016
Resolved
Replace discharged B-II portable fire extinguisher in aft storage space. 46 CFR 115.810
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 1 November 2016
Resolution: Replaced B-II portable fire extinguisher.
Engineering › Fuel Oil Service System › Piping
Issued 1 November 2016
Resolved
Install proper pipe hangars in Larazette. 46 CFR 56.60-25
Action required: 705 - Other - as specified
Due 1 December 2016
Resolved 22 November 2016
Resolution: Proper pipe hangars installed to the satisfaction of the Marine Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 25 July 2016
Resolved
Submit repair plan for approval then execute repairs for severe hull pitting IAW 46CFR176.25-5.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2016
Resolution: Affected areas was croped and renewed.
Construction/Loadline › Hull › Bottom Plating
Issued 19 July 2016
Resolved
Repair two holes identified by vessel rep as planned IAW 46CFR176.25-5
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2016
Resolution: Affected area was croped and renewed.
Construction/Loadline › Structures › End Bulkhead
Issued 19 July 2016
Resolved
Repair two wasted tripping brackets found in aft void IAW 46CFR176.25-5.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 August 2016
Resolution: Affected area was croped and renewed.