← All vessels
STARLITE HORIZON
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southeast District (CGD-SE) · Other hulls named STARLITE HORIZON
STARLITE HORIZON is a 1981 passenger vessel (inspected). The Coast Guard has recorded 104 inspections since 1981, most recently in July 2026, along with 190 deficiencies, 1 operational control and 4 casualty investigations between 2009 and 2015.
Records from 1981 to 2026. Most recent: inspection, 6 July 2026.
- Built
- 1981
- Last inspected
- 6 July 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 104
- Deficiencies
- 190 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 4 investigations · 2009–2015
Identity
641630
WCX8324
52963
Flag
UNITED STATES
367311850
Maury page id
psix-52963
Inspections, by type
…with no type recorded15
Years with a record
41 calendar years (1981–2026)
The 104 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)98.2 ft × 30.0 ft × 6.6 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderQUEEN CRAFT DIV MARINE · PANAMA CITY, FL, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portST PETERSBURG, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 11 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WCX8324MMSI 367311850 · active · compulsorily equipped · granted 23 August 2017, expires 7 November 2027
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 104
6 July 2026
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8430410
18 November 2025
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8249938
29 May 2025
Administrative Inspection · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8146925
18 November 2024
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8027856
3 September 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7995464
15 November 2023
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7804637
7 November 2023
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7807636
1 May 2023
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7674681
7 September 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7555228
23 August 2022
Deficiency Check · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7517733
10 March 2022
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7407392
16 November 2021
Annual Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7336570
16 March 2021
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7157120
11 August 2020
DAPI Audit · Permit to Proceed · MTSA Verification · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6984072
28 July 2020
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7030772
22 May 2020
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6955452
19 November 2019
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6848835
14 November 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6566343
5 September 2018
Deficiency Check · Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6532718
28 August 2018
Drydock Exam · Deficiency Check · Administrative Inspection · Examination of Repairs · Permit to Proceed
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6499217
15 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6512783
29 August 2017
Deficiency Check · DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6173753
1 November 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6009648
19 July 2016
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5945574
30 November 2015
MTSA Verification · Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5772014
21 November 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5769593
8 March 2014
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4813930
5 December 2011
Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4214350
29 November 2010
Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3900963
9 September 2010
Internal Structural Exam · Administrative Inspection · Drydock Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3845816
10 November 2008
DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3360383
22 September 2008
Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3330313
2 October 2007
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3074174
6 September 2007
MTSA Verification · COI Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3049815
20 June 2007
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2967802
23 October 2006
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2806424
20 September 2006
Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2777537
26 September 2005
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2498016
18 January 2005
Internal Structural Exam · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2268822
9 December 2004
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2256257
14 September 2004
Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2183420
30 June 2004
MTSA Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2114675
4 December 2003
Deficiency Check · In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1958269
30 September 2003
Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1907075
17 January 2003
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1724242
10 October 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1688000
6 September 2002
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1667971
19 August 2002
Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1663348
8 May 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1614628
4 January 2002
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1475436
31 October 2001
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1432573
13 September 2001
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1075736
7 September 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1445875
3 May 2001
Deficiency Check · Drydock Extension
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1062373
29 January 2001
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1061146
27 January 2001
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 16761
12 March 2000
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 57888
5 October 1999
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1194258
7 September 1999
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1375892
30 July 1999
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1397217
29 March 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 664476
16 March 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 119516
5 October 1998
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1415055
26 March 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 787192
23 March 1998
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 120136
27 October 1997
Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1381159
7 August 1997
Hull Examination · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1454470
1 August 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 180851
13 March 1997
Damage Survey · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1441197
12 March 1997
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 25776
21 October 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 753381
16 September 1996
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 196633
16 September 1996
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1466986
23 January 1996
Deficiency Check · Hull Examination · Inclining Experiment
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1425683
18 September 1995
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 884238
19 September 1994
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1178591
22 March 1994
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 856345
11 January 1994
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 852117
5 January 1994
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1164172
20 December 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1160405
4 October 1993
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 826726
11 February 1993
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 836393
5 October 1992
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 961721
9 January 1992
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 954153
13 November 1991
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1311487
15 October 1991
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 938599
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1249268
2 May 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1228463
9 November 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1232250
15 October 1990
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1214610
26 February 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 905004
16 January 1990
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1219009
16 October 1989
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1314241
20 June 1989
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1341671
13 January 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1198203
27 September 1988
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 886468
21 July 1988
Drydock Extension
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1341150
19 October 1987
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1330206
9 January 1987
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1318535
21 October 1986
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1017112
22 October 1985
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1300056
23 September 1985
Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 990860
23 October 1984
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1283565
29 October 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1275549
Deficiency record · 190
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 November 2024
Resolved
At each inspection the marine inspector shall inspect all life saving equipment to determine its servicability.
03 liferings had damaged or faded retro reflective tape. Replace retro on each ring to the satisfaction of the Coast Guard.
46CFR176.25-22
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 18 November 2024
Resolved
fuel system to include tanks, vents, piping, and fittings.
The centerline generator fuel line, going into the raycor filter was found chaffed. Replace fuel line to the Coast Guards satisfaction.
46 CFR 176.25-10
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 November 2024
Resolved
At each inspection the marine inspector shall examine fuel system to include tanks, vents, piping, and fittings.
A fuel leak was found on the port propulsion engine leaking onto the exhaust manifold. This was a loose fitting that was corrected on the spot.
46 CFR 176.25-10
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 18 November 2024
Resolved
150 passengers, shall meet the requirements of subpart 72.05 subchapter H.
01 fire door was not closing. Adjustments were made and the door was operating properly before inspection completion.
46 CFR 177.10-5
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 18 November 2024
Resolved
At each inspection the marine inspector shall examine electrical systems to ensure they are in operating condition.
The emergency lighting system did not activate upon power failure. A switch for the emergency light systems located under the console in the pilothouse was off. One energized, the emergency light system functioned properly.
46 CFR 176.25-15
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 23 August 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks.
In Laz space, identified corrosion on stringer/bulkhead/deck plate on fwd port side along with fractured weld from tripping bracket to stiffener aft port side. On deck 1 transom, identified 3" diameter hole.
46 CFR 176.20-1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 August 2022
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including: (a) Operation of the main propulsion machinery both ahead and astern.
Port M/E has exhaust leak and is not gas tight.
46 CFR 182.20-20
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in charge, Marine Inspection.
Pilothouse DC system fuses are missing labels.
46 CFR (Old T)183.01-15
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 23 August 2022
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection.
Pilothouse AC distribution system breaker is missing a label for the marine radar.
46 CFR (Old T)183.01-15(a)
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 August 2022
Resolved
Remote fuel shutoff stations shall be marked in at least 1-inch letters indicating purpose of the valve and direction of operation.
Remote fuel shutoff valve not easily marked/identified.
46 CFR (Old T)185.30-20
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 23 August 2022
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall require that all observed unsafe practices and hazardous situations be corrected.
Tripping hazard identified on main deck by port/stbd
galley/service entry.
46 CFR (Old T)176.25-50
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 14 November 2018
Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters at least 25 millimeters 1 inch high. MI found markings on watertight door non-legible, mark door to the satisfaction of attending MI.
46 CFR 122.610
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2018
Resolved
Deficiency code 13199
Starboard side propeller has a cracked blade, show suitable service condition to attending marine inspector. 46CFR115.840
Action 705c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2018
Resolved
Deficiency code 13199
Both propellers shaft need to be pulled out for further
inspection by the Marine Inspector. 46CFR115.670(a)
Action 705c
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 August 2018
Resolved
Deficiency code 02112
Lazzarette, UT Shot deck plate under watertight hatch area, show proper material thickness to attending marine inspector satisfaction. 46CFR115.700(d)
Action 705c
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 28 August 2018
Resolved
Deficiency code 02107
Found holes on top sewage tank, repair to attending marine inspector satisfaction. 46CFR115.800(a)
Action 705 c
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 28 August 2018
Resolved
Deficiency code 03112
Lazzarette s/side thru hull piping needs to be replaced,
replace to attending marine inspector atisfaction. 46CFR115.700(d)
Action 705 c
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 August 2018
Resolved
Deficiency code 02112
UT shot, engine Room port side under main fire pump,
show proper material thickness to attending marine
inspector. 46CFR115.700(d)
Action 705 c
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 August 2018
Resolved
Deficiency code 02112
UT shot, engine room under watertight door to water
room, show proper material thickness to attending marine
inspector. 46CFR115.700(d)
Action 705 c
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 28 August 2018
Resolved
Deficiency code 02112
UT shot, starboard side water room aft and bow, show
proper material thickness to attending marine inspector. 46CFR115.700(d)
Action 705 c
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2018
Resolved
Bilge pipes under valves at engine room, replace bad pipes and submit working plan in order to replace flex hoses. - 46CFR119.510
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2018
Resolved
Engine room aft, starboard side and port side insulation needs to be refreshed. - 46CFR116.415(a)(2)(i)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 August 2018
Resolved
Found a hole in bilge pipe in the liquor room. - 46CFR119.510
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018
Resolved
Vsl is broadcasting: Greater/smaller than expected vessel length and no dimension information (AIS Antenna Position ABCD values equals 0).
Engineering › Bilge Water Management System › Strainer
Issued 29 August 2017
Resolved
Repair fuel supply space and machinery space bilge suction units. 46CFR182.25-5
Fire Fighting › Structural - A Class Divisions › Doors
Issued 29 August 2017
Resolved
Repair door on third deck of stairwell. 46CFR116.435
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 1 November 2016
Resolved
Ensure fire doors fully self close on main and 3rd deck. 46 CFR 116.435
Fire Fighting › Portable CO2 Fire Extinguisher › Discharge Hose/Tube
Issued 1 November 2016
Resolved
Replace discharged B-II portable fire extinguisher in aft storage space. 46 CFR 115.810
Engineering › Fuel Oil Service System › Piping
Issued 1 November 2016
Resolved
Install proper pipe hangars in Larazette. 46 CFR 56.60-25
Construction/Loadline › Hull › Hull Plating
Issued 25 July 2016
Resolved
Submit repair plan for approval then execute repairs for severe hull pitting IAW 46CFR176.25-5.
Construction/Loadline › Hull › Bottom Plating
Issued 19 July 2016
Resolved
Repair two holes identified by vessel rep as planned IAW 46CFR176.25-5
Construction/Loadline › Structures › End Bulkhead
Issued 19 July 2016
Resolved
Repair two wasted tripping brackets found in aft void IAW 46CFR176.25-5.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 1 December 2015
Resolved
Install guard over fan in aft steering space on port side per 46CFR177.35-15
Electrical › Electric Supply System (service) › Cable
Issued 1 December 2015
Resolved
Properly terminate or splice wires in aft steering space and aft decks port/starboard sides per 46CFR183.05-50.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 29 November 2010
Resolved
Cracked waterlight on starboard life ring must be repaired or replaced as per 46 CFR 117.70 (d).
Engineering › Bilge Water Management System › Piping
Issued 29 November 2010
Resolved
Engine room bilges need to be cleaned as per 46 CFR 115.830(b)
Construction/Loadline › Structures › End Bulkhead
Issued 9 September 2010
Resolved
Complete fabrication & fit-up of the handrails on port and starboard aft weather decks, to the satisfaction of the attending Marine Inspector. 46 CFR 176.100.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 9 September 2010
Resolved
Complete the installation of steel pipe inserts for water & drain piping to meet structural fire protection requirements IAW existing 46 CFR 177.10-5 (old).
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 November 2008
Resolved
SERVICE PORTABLE FIRE EXTINGUISHER IN AFT STORAGE.
Engineering › Pressure Vessel › Relief Valve
Issued 10 November 2008
Resolved
TEST OR REPLACE RELIEF VLV ON PRESSURE VESSEL.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 November 2008
Resolved
REMOVE DEAD-ENDED CABLE IWO PORT GENERATOR.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 10 November 2008
Resolved
INSTALL CHAFING NUT ON JUNCTION BOX FOR INBOARD FIRE PUMP.
Fire Fighting › Structural - A Class Divisions › Door Frames
Issued 10 November 2008
Resolved
INSULATE STBD SIDE A-60 DOOR AROUND FRAME LEADING TO THE GALLEY.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 10 November 2008
Resolved
REPAIR L/O LEAK ON STBD PROPULSION ENGINE'S FILTER ASSEMBLY.
Engineering › Diesel Engine (auxiliary) › Block
Issued 10 November 2008
Resolved
REPAIR L/O LEAK ON STBD SHIPS SERVICE GENERATOR'S OUTBOARD SENSOR.
Electrical › Electrical Distribution System (service) › Cable
Issued 10 November 2008
Resolved
REPAIR/REPLACE POWER CORD FOR MIXER LOCATED IN AFT STORAGE COMPARTMENT.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 10 November 2008
Resolved
PROVIDE COAST PILOT, LIGHT LIST & TIDE TABLES WITHIN 3 YEARS.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 10 November 2008
Resolved
PROVIDE COMPASS DEVIATION CARD.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 10 November 2008
Resolved
UPDATE FIRE CONTROL PLAN TO SHOW FIRE EXT CHANGE AND FIRE BOUNDRY CLASSIFICATION.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 10 November 2008
Resolved
PROVIDE UPDATED DRUG CONSORTIUM EMPLOYEE LIST.
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 10 November 2008
Resolved
UPDATE EMERGENCY PLAN TO IDENTIFY SPECIFIC OTHER CREW POSITIONS AND TRAINING FOR DUTIES (CROWD CONTROL). IDENTIFY WHICH BILLET IS IN CHARGE OF PASSENGERS ON REFUGE AREA DECK.
Documentation › Markings/Placards › Garbage Placard
Issued 10 November 2008
Resolved
POST GARBAGE PLACARDS.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 November 2008
Resolved
PROVIDE A PATCH FOR PORT SIDE GALLEY A CLASS DOOR.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 10 November 2008
Resolved
ADJUST PORTSIDE MAINDECK STAIRWELL DOOR TO FULLY CLOSE.
Communications › Radio Communications › EPIRB
Issued 10 November 2008
Resolved
PROVIDE HYDRO RELEASE FOR EPIRB. VSL RESTRICTED TO SHOREWARD OF DEMARCATION LINE PER 33 CFR PART80.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 10 November 2008
Resolved
MAKE EMERGENCY LIGHTING AT 3RD DK OPERABLE.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 10 November 2008
Resolved
PROVIDE MONTHLY MAINTENANCE CHECKLIST FOR PORTABLE FIRE EXT.
Communications › Radio Communications › EPIRB
Issued 10 November 2008
Resolved
PROVIDE MONTLY EPIRB TEST RECORDS.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 September 2008
Resolved
REPLACE A-0 DOOR IN WAY OF STAIRTOWER EXIT LEADING OUT TO TH THIRD DK. PROVIDE LOCAL OCMI A COPY OF THE PROCUREMENT REQUEST ONCE ORDER IS MADE.
Electrical › Electric Generation Source (service) › Generator
Issued 2 October 2007
Resolved
Throughout the course of the servicing and repairs of the port and stbd generators prove proper operation of each generator as they are re-installed and prior to the carriage of passengers. The vessel is restricted to 353 total passengers, 185 of these passengers may be on the 2nd and 3rd deck of which 48 may be on the upper most deck until the temporary generator is removed from the 3rd deck.
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 6 September 2007
Resolved
Repair chalkfast on Stbd. propulsion engine. The existing chalkfast is cracked and missing from engine mounts.
Communications › Alarms/Indicators › Bilge Alarm
Issued 6 September 2007
Resolved
Install bilge high water alarm in liquor compartment. A high water alarm has never been installed in this compartment, one is required due to transducers located in the bilge.
Electrical › Electric Supply System (service) › Cable
Issued 6 September 2007
Resolved
Remove extension cord from DC converters in engine room.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 6 September 2007
Resolved
Remove oil and debris throughout vsl's bilges.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 6 September 2007
Resolved
Properly train crewmembers on EAP requirements before they assume sensitive positions.
Electrical › Electric Generation Source (service) › Generator Cable
Issued 6 September 2007
Resolved
Clean oil and grime from generator windings.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 September 2007
Resolved
Conduct satisfactory underway MOB drill ICO MI.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 September 2007
Resolved
Provide written training program for MOB evolutions.
Fire Fighting › Structural - A Class Divisions › Main Galleys
Issued 6 September 2007
Resolved
Prior to credit for next drydock, provide A-60 insulation in overhead and FWD bulkhead of galley.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 6 September 2007
Resolved
Provide plans and material for wait station void A-0 hatch.
Fire Fighting › Structural - A Class Divisions › Open Deck Spaces
Issued 6 September 2007
Resolved
Make all A-0 main deck piping penetrations proper as recommended by NVIC 9-97 prior to next drydock.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 October 2006
Resolved
Repair or replace exhaust blankets on both generator exhaust systems. The generators have the old style hard exhaust blankets and are falling off and or missing a section exposing the hot muffler. POC stated that they will replace it with the cloth/soft blankets like they did for the MDE's.
Electrical › Electric Supply System (service) › Cable
Issued 23 October 2006
Resolved
Repair wiring going into outlet box in freezer space, AFT, behind ladder. The insullation was pulled back exposing the wires inside.
Navigation › Collision/Grounding Avoidance › Danger Messages
Issued 23 October 2006
Resolved
Repair or replace bell. Bell was missing the clacker.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 October 2006
Resolved
Properly hook float light to ring buoy. Line was to short and it wasn't wrapped around the body of ring.
Navigation › Piloting/Steering › Marine Charts
Issued 23 October 2006
Resolved
Provide a new nautical chart or provide an up-to-date chart with notice to mariners.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 23 October 2006
Resolved
Provide a proposal to make service station ladder area A-0. This area has no proper A-0 boundary. They have a makeshift entrance made out of wood and the wall boards are hollow covered by laminate. Discussed proper means of structural fire protection on this class vessel with owner.
Construction/Loadline › Structures › Deck Plating
Issued 20 September 2006
Resolved
Crop and renew wasted outside deck area IWO PORT AFT door. Found two holes through deck over side rub rail. Found the entire deck area outside door to be wasted. POC stated they plan on replacing the entire area with new steel.
Construction/Loadline › Penetrations › Weld
Issued 20 September 2006
Resolved
Crop and renew PORT AFT cleat. Cleat is wasted and holed.
Construction/Loadline › Penetrations › Pipe Flange
Issued 20 September 2006
Resolved
Crop and renew both PORT side water tank vents. Vents are wasted at the bend. Authorized POC to install PVC piping onto existing steel pipe due to height above margin line/main deck.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 September 2006
Resolved
Remove light fixture on FWD BLKHD of refrigerator space or hardwire per CFR, Part 120.
Engineering › Bilge Water Management System › Strainer
Issued 20 September 2006
Resolved
Provide a proper bilge strainer for engine room bilge pick-up. POC installed a home made bilge strainer that doesn't meet the regulations.
Construction/Loadline › Structures › Superstructure
Issued 20 September 2006
Resolved
Provide copies of existing plans for vessel for review. This office has no plans of vessel.
Stability › Incline Test › General
Issued 14 September 2004
Resolved
PROVIDE MSC INFORMATION CONCERNING 9 CUBIC YARDS OF FIXED CEMENT BALLAST LOCATED IN FOREPEAK OF VESSEL. CURRENT STABILITY LETTER ISSUED 29SEP03 DOES NOT ADDRESS EXISTING FIXED BALLAST INSTALLATION.
Engineering › Bilge Water Management System › Strainer
Issued 14 September 2004
Resolved
PROPERLY INSTALL FOOT VALVE ON ENGINE ROOM BILGE SUCTION LINE PRIOR TO CARRIAGE OF PASSENGERS.
Fire Fighting › Fire Hoses
Issued 30 September 2003
Resolved
REPLACE 03 DECK 1.5" X 50' FIRE HOSE. LEGACY COMPONENT DESC: Condition
Engineering › Bilge Water Management System
Issued 30 September 2003
Resolved
REMOVE PVC BILGE EXTENSION IN ENGINE ROOM AND REPLACE WITH METALLIC PIPING AND STRAINER. PIPE SPLICE MUST BE ACCOMPLISHED WITH SAE J-1942 APPROVED HOSE WITH DOUBLE HOSE CLAMPS OR WELDED PIPE. LEGACY COMPONENT DESC: Piping
Engineering › Bilge Water Management System › Valve
Issued 30 September 2003
Resolved
REPAIR BILGE SUCTION IN FUEL ROOM PRIOR TO CARRIAGE OF PASSENGERS.
Engineering › Lubricating Oil Service System
Issued 30 September 2003
Resolved
REPAIR OIL PRESSURE GAUGES IN PILOT HOUSE. LEGACY COMPONENT DESC: Gauge
Construction/Loadline › Structures › Door
Issued 30 September 2003
Resolved
ADJUST DOGS AS NEEDED ON ALL WATERTIGHT DOORS PRIOR TO CARRIAGE OF PASSENGERS.
Operations/Management › Lifesaving
Issued 30 September 2003
Resolved
UPDATE FIRST AID/CPR CERTIFICATIONS. LEGACY COMPONENT DESC: First Aid Certification
Accommodation/Occupational Safety › Ventilation
Issued 10 January 2003
Resolved
Clean both galley exhaust. LEGACY COMPONENT DESC: Galley Exhaust Fan
Electrical › Electrical Distribution System (service)
Issued 6 September 2002
Resolved
Repair double burner wire conduit. LEGACY COMPONENT DESC: Cable
Electrical › Electrical Distribution System (service)
Issued 6 September 2002
Resolved
Repair junction box behind oven. LEGACY COMPONENT DESC: Junction Box
Stability › Weathertight Integrity
Issued 6 September 2002
Resolved
Prior to the completion of your next Credit Drydock Examination, repair/replace wasted STBD side galley door frame. LEGACY COMPONENT DESC: Galley Door
Electrical › Electrical Distribution System (service)
Issued 6 September 2002
Resolved
Repair wire connections going into the control junction box on the air compressor. LEGACY COMPONENT DESC: Junction Box
Electrical › Electrical Distribution System (service)
Issued 6 September 2002
Resolved
Provide a rubber mat, and place it at the foot of the switch board in the engine room. LEGACY COMPONENT DESC: Switchboard
Construction/Loadline › Penetrations
Issued 30 August 2002
Resolved
Prior to next drydock provide [name withheld] with CG MSC approved plans for enclosing and providing watertight closure for the port side engine room ventilation intake to meet downflooding requirements for continued operation on a partially protected route out to the Clearwater Pass Jetty's. LEGACY COMPONENT DESC: Engineroom Ventilation
Construction/Loadline › Hull
Issued 30 August 2002
Resolved
Prior to completion of next drydock provide Marine Safety Center approved stability letter for operation on partially protected water to continue operation beyond demarcation out to Clearwater Pass Jetty.
Operations/Management › Drug and Alcohol Testing
Issued 8 May 2002
Resolved
Provide approved EAP pamphlet for training crew IAW NVIC 8-93, and refer to 46 CFR 116.530, 116.520 for content. LEGACY COMPONENT DESC: EAP Training Requirements
Fire Fighting
Issued 31 October 2001
Resolved
SERVICE 2 B-II FIRE EXTINGUISHERS PRIOR TO CARRIAGE OF PASSENGERS.
Lifesaving
Issued 31 October 2001
Resolved
SECURE STOVE TOP IN GALLEY.
Lifesaving
Issued 31 October 2001
Resolved
INSTALL 2 EMERGENCY LIGHTS ON FWD PASSENGER DECK.
Lifesaving
Issued 31 October 2001
Resolved
REPAIR RETRO ON LIFEJACKETS AS NEEDED
Lifesaving
Issued 31 October 2001
Resolved
REPLACE TWO 24" LIFERING PRIOR TO CARRIAGE OF PASSENGERS.
Lifesaving
Issued 31 October 2001
Resolved
SECURE REFRIGERATOR IN COMPT. UNDER GALLEY.
Fire Fighting
Issued 31 October 2001
Resolved
INSTALL VENT CLOSURE IN GALLEY VENT PORT SIDE.
Fire Fighting
Issued 31 October 2001
Resolved
REPAIR/REPLACE STRUCTURAL FIRE PROTECTION INSULATION IN ENGINE ROOM AS NEEDED. (ONE FOOT DOWN SIDE SHELL FROM OVERHEAD).
Lifesaving
Issued 31 October 2001
Resolved
REPAIR/REPALCE 6 ADULT LIFEJACKETS. PASSENGER COUNT REDUCED BY 6 UNTIL COMPLETED.
Lifesaving
Issued 31 October 2001
Resolved
PROVIDE EEP PAMPHLET FOR TRAINING CREW IAW NVIC 8-93.
Lifesaving
Issued 31 October 2001
Resolved
POST/PROVIDE EMERGENCY EVACUATION PLAN IAW 46 CFR 116.530 TO MSO TAMPA FOR REVIEW AND APPROVAL.
Construction/Loadline
Issued 31 October 2001
Resolved
REPAIR ENGINE ROOM HIGH LEVEL AUDIO ALARM
Engineering
Issued 31 October 2001
Resolved
INSTALL LAGGING AS NEEDED ON MAIN EXHAUST AND GENSET EXHAUST.
Fire Fighting
Issued 31 October 2001
Resolved
PRIOR TO COMPLETION OF DRYDOCK, PROVE CONDITION OF STRUCTURAL FIRE PROTECTION THROUGHOUT VESSEL AND REPAIR/REPLACE AS NEEDED.
Engineering
Issued 31 October 2001
Resolved
REPLACE PLASTIC PLUG ON STBD FUEL STRAINER WITH METALLIC PLUG.
Construction/Loadline
Issued 7 September 2001
Resolved
MAKE PROPER REPAIR ON TEMPORARY ACCESS CUT ON FWD NON WATERTIGHT BULKHEAD IN LAZARETTE TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR ON NEXT DRYDOCK.
Construction/Loadline
Issued 7 September 2001
Resolved
CROP AND RENEW TO GOOD METAL TRANSVERSE BOTTOM LONG ON PORT SIDE FWD BAY INLAZARETTE ON NEXT DRYDOCK.
Construction/Loadline
Issued 7 September 2001
Resolved
GAUGE WASTAGE ON BILGE AREA OF FREEZER ROOM TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR ON NEXT DRYDOCK.
Construction/Loadline
Issued 20 November 2000
Resolved
INSTALL VENT CLOSURES FOR ENGINE ROOM VENTILATION.
Lifesaving
Issued 7 September 1999
Resolved
INSTALL RETROFLECTIVE TAPE ON AFT RING BOUY PRIOR TO SAILING.
Electrical
Issued 7 September 1999
Resolved
GROUND COMPRESSOR FOR SODA MACHINE UNDER BAR.
Construction/Loadline
Issued 7 September 1999
Resolved
INSTALL VISUAL ALARM FOR AFT RUDDER ROOM HIGH LEVEL BILGE ALARM.
Lifesaving
Issued 7 September 1999
Resolved
SECURE GALLEY EQUIPMENT FOR SEA.
Lifesaving
Issued 7 September 1999
Resolved
REPLACE RETROFLECTIVE MATERIAL ON LIFE JACKETS AS NEEDED PRIOR TO SAILING.
Electrical
Issued 7 September 1999
Resolved
REMOUNT BATTERY SWITCH FOR STBD GENERATOR AND SECURE SWITCH FOR FIRE PUMP.
Electrical
Issued 5 October 1998
Resolved
INSTALL BATTERY SWITCHES IN GENERATOR BATTERY SYSTEM.
Electrical
Issued 5 October 1998
Resolved
REMOVE EXTENSION CORDS FROM SERVICE OF EQUIPMENT USED WHILE PASSENGERS ARE ON BOARD.
Electrical
Issued 5 October 1998
Resolved
REMOVE DAMAGED SHORE POWER CABLE FROM SERVICE.
Fire Fighting
Issued 5 October 1998
Resolved
PRIOR TO CARRIAGE OF PASSENGERS INSTALL LATCH ASSEMBLY IN ENG RM FIRE SCREEN DOOR.
Navigation
Issued 23 March 1998
Resolved
FITTING BEGAN LEAKING WHILE MASTER WORKED RUDDERS WHILE VESSEL AGROUND.
Fire Fighting
Issued 27 October 1997
Resolved
ADJUST/MODIFY FSD'S IN STAIRTOWER TO MEET REQUIUREMENTS OF 46 CFR 116.435(C).
Electrical
Issued 27 October 1997
Resolved
REMOVE EXTENSION CORDS FROM SERVICE.
Lifesaving
Issued 27 October 1997
Resolved
PROVIDE SUITABLE RESCUE BOAT FOR PERSONNEL RETRIEVAL. DEMONSTRATE ABILITY_x001C_OF CREW TO LAUNCH AND RECOVER PERSON IN WATER.
Lifesaving
Issued 27 October 1997
Resolved
MOUNT LIFE PRESERVER DONNING INSTRUCTION PLACARD @ 2ND DECK PFD LOCKER.
Lifesaving
Issued 27 October 1997
Resolved
MOUNT EMERG BROADCAST PLACARD ADJACENT TO VHF STATION.
Fire Fighting
Issued 27 October 1997
Resolved
INDICATE LOCATION OF F/E ON MAINDECK ADJACENT TO STAGE OR RELOCATE IN PLAINVIEW.
Fire Fighting
Issued 27 October 1997
Resolved
REPLACE F/E @ 2ND DECK BAR WITH USCG APPROVED F/E.
Fire Fighting
Issued 27 October 1997
Resolved
REMOVE HOLD-BACK DEVICE ON PORTSIDE GALLEY DOOR.
Documentation
Issued 27 October 1997
Resolved
PROVIDE COPY OF FCC RADIO STATION LICENSE.
Lifesaving
Issued 27 October 1997
Resolved
PROVIDE EAP TRNG FOR CREW.
Fire Fighting
Issued 27 October 1997
Resolved
REPLACE B-I F/E IN GALLEY WITH B-II F/E.
Lifesaving
Issued 27 October 1997
Resolved
SCHEDULE CG OVERSIGHT OF: MAN-OVER-BOARD; FIRE; AND, DAMAGE CONTROL DRILLS.
Engineering
Issued 7 August 1997
Resolved
REMOVE PETCOCK TYPE DRAIN VALVES FROM ALL FUEL AND LUBE OIL STRAINERS.
Engineering
Issued 1 August 1997
Resolved
Shaft was misaligned when installed causing it to shear.
Engineering
Issued 1 August 1997
Resolved
Same as MCDR 0001 deficiency identification.
Fire Fighting
Issued 13 March 1997
Resolved
INSTALL ADEQUATE STOP VALVES AT EACH FIRE STATION CONFIGURED SO THAT EACH FIRE STATION MAY BE ISOLATED FROM THE FIRE MAIN SYSTEM.
Fire Fighting
Issued 16 September 1996
Resolved
REPAIR LATCH MECHANISM ON ENG RM DOOR.
Documentation
Issued 16 September 1996
Resolved
PROVIDE CHEMICAL TESTING MIS REPORT (46 CFR 16.500).
Engineering
Issued 16 September 1996
Resolved
MARK DIRECTION OF CLOSURE ON EMERGENCY F/O SHUT-OFF VALVE.
Lifesaving
Issued 16 September 1996
Resolved
INSTALL RETRO-REFLECTIVE MATERIAL ON RINGBUOYS.
Fire Fighting
Issued 16 September 1996
Resolved
DEMONSTRATE ADEQUATE AND OIL FREE FIRE FIGHTING WATER PRESSURE AT UPPERMOSTFIRE STATION.
Fire Fighting
Issued 16 September 1996
Resolved
REMOVE HOLDBACK DEVICES FROM ENG RM DOOR AND GALLEY DOOR.
Engineering
Issued 5 January 1994
Resolved
Prove no excessive vibration on port shaft from nicked propeller via underway test by attending inspector.
Construction/Loadline
Issued 5 January 1994
Resolved
Attending inspector to verify proper draft marks, homeport, and vessel nameare marked/painted on hull.
Accommodation/Occupational Safety
Issued 4 October 1993
Resolved
Stencil forward below deck emergency exit above & below with "emergency exit keep clear".
Electrical
Issued 4 October 1993
Resolved
Label breaker in the following panels: bridge, 2nd deck, and galley.
Electrical
Issued 4 October 1993
Resolved
Install globe cover on emergency light in 2nd to 3rd deck stair well.
Lifesaving
Issued 5 October 1992
Resolved
Repair or replace retro-tape on adult and child pfd's.
Lifesaving
Issued 5 October 1992
Resolved
Repair outer covering on 3rd deck/port life ringbuoy.
Lifesaving
Issued 5 October 1992
Resolved
Label pfd lockers on 2nd/3rd deck.
Lifesaving
Issued 5 October 1992
Resolved
Provide 60' line on 3rd deck/starboard life ringbuoy and repair damage to outer covering.
Lifesaving
Issued 15 October 1991
Resolved
REPLACE REFLECTIVE TAPE ON 6 ADULT PFD'S.
Accommodation/Occupational Safety
Issued 15 October 1991
Resolved
INSTALL CHAINS (2 AFT, 1 FWD) FOR PREVENTING PASSENGERS FROM USING MAIN DECK WHEN AUTHORIZED 2 DECKHANDS.
Engineering
Issued 15 October 1991
Resolved
INSTALL HANDWHEEL IN PORT FUEL RETURN @ TANK.
Construction/Loadline
Issued 15 October 1991
Resolved
RESTENCIL ALL WT DOORS AT FRAMES 12,18,24,30&38: "WATER TIGHT DOOR-MUST BE CLOSED AT ALL TIMES.
Electrical
Issued 15 October 1990
Resolved
SOLDER ALL GENERATOR BATTERY CONNECTIONS.
Deck/Cargo
Issued 15 October 1990
Resolved
REMOVE SPOOLS OF ROPE FROM MACHINERY SPACES.
Electrical
Issued 15 October 1990
Resolved
REPAIR SHORE TIE AND GENERATOR AVAILABLE LIGHTS.
Lifesaving
Issued 15 October 1990
Resolved
REPLACE 3 ORANGE DISTRESS SIGNALS PRIOR TO CARRYING PASSENGERS.
Electrical
Issued 15 October 1990
Resolved
REWIRE LIGHTS IN PILOT HOUSE CONSOLE ENDS WITH MARINE TYPE WIRE.
Deck/Cargo
Issued 15 October 1990
Resolved
REPAIR/REPLACE 3 BROKEN MOLDED SEATS (ONE ON 2ND DECK AND TWO ON 3RD DECK).
Documentation
Issued 15 October 1990
Resolved
POST STABILITY LETTER IN PILOT HOUSE SO THAT BOTH PAGES ARE VISIBLE.
Documentation
Issued 15 October 1990
Resolved
POST EMERGENCY CHECKOFF LIST ON EACH DECK.
Fire Fighting
Issued 15 October 1990
Resolved
RENEW 2 FIREHOSES WITH ALUMINUM COUPLINGS AND REPLACE WITH ONES HAVING BRONZE COUPLINGS.
Electrical
Issued 15 October 1990
Resolved
REMOVE EXTENSION CORDS FROM BOTH REFRIGERATORS (BELOW DECK).
Documentation
Issued 16 January 1990
Resolved
CREDIT DRYDOCK DUE 31JUL91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Construction/Loadline
Issued 16 January 1990
Resolved
PROVIDE CAPTIVE CHAIN ON HATCH TO FOREPEAK COMPARTMENT.
Engineering
Issued 16 January 1990
Resolved
REPAIR OIL LIAK AT PORT MAIN ENGINE OIL FILTER.
Electrical
Issued 16 January 1990
Resolved
REMOVE EXTENSION CORDS AND PERMANENTLY WIRE EXISTING INSTALLATIONS IN COMPARTMENT AFT OF ENGINE ROOM.
Electrical
Issued 20 June 1989
Resolved
REPAIR EXHAUST LINE FOR STBD GENERATOR AS ORIGINAL. TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION PRIOR TO 06JUL89.
Lifesaving
Issued 27 September 1988
Resolved
PROVIDE ADDITIONAL 35 ADULT AND 4 CHILD LIFE PRESERVERS. PERSONS CARRIED REDUCED BY THESE AMOUNTS UNTIL PROVIDED.
Lifesaving
Issued 27 September 1988
Resolved
PROVIDE SIX ORANGE SMOKE HAND DISTRESS SIGNALS.
Accommodation/Occupational Safety
Issued 27 September 1988
Resolved
CLEAN GREASE FROM GALLEY EXHAUST FANS.
Fire Fighting
Issued 19 October 1987
Resolved
RENEW FIRE HOZE ON THIRD DECK.
Lifesaving
Issued 19 October 1987
Resolved
PROVIDE ONE ADDITIONAL ADULT AND SIX ADDITIONAL CHILD LIFE PRESERVERS. PASSENGERS ARE REDUCED BY THAT AMOUNT UNTIL LIFE PRESERVERS ARE PROVIDED.
Documentation
Issued 19 October 1987
Resolved
POST EMERGENCY CHECK-OFF LIST.
Lifesaving
Issued 23 October 1984
Resolved
PROVIDE 5 ADDITIONAL LIFE PRESERVERS.
Unknown
Issued 23 October 1984
Resolved
PROVE OPERATION OF RELIEF VALVE ON AIR RECEIVER.
Lifesaving
Issued 23 October 1984
Resolved
REPAIR WATER LIGHT FOR STB. RING BUOY.
Unknown
Issued 23 October 1984
Resolved
FREE UP REACH ROD TO SUCTION LINE IN FWD. COMPARTMENT.
Casualty record · 4
9 August 2009Routine · role: Involved in a Marine Investigation (non-casualty) · serious marine incident, as classified · 1 injured · activity 3565016
3 October 2012Routine · role: Involved in a Marine Casualty · activity 4456734
8 March 2014Routine · role: Involved in a Marine Casualty · 1 injured · activity 4813930
21 November 2015Routine · role: Transiting Vicinity of Primary Subject · at BELLEAIR CAUSEWAY · activity 5769593
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 1
STARLITE MAJESTY (2009–2015). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.