Records from 1981 to 2007. Most recent: inspection, 27 April 2007.
Documentation record
Registered dimensions (L × B × D)90.0 ft × 28.0 ft × 5.6 ft
Registered tonnagegross 206 / net 206
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBOURG BARGES INC · HOUMA, LA, UNITED STATES · built 1980
Hull materialSteel
PropulsionNot recorded
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 19 November 2025 · expires 31 December 2026
Service, as the file records itUnclassified
Hull formunknown (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it206 - Regulatory (Subpart C or D), Net Ton
206 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 27
27 April 2007
Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2916972
21 March 2006
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2606397
21 June 2005
Security Plan Amendment Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2398030
13 June 2005
Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2389282
31 May 2004
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2110372
4 March 2004
Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2018142
5 March 2003
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1753135
11 December 2002
Internal Structural Exam · Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1626554
17 February 2002
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1607785
15 July 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380010
20 September 1993
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 647598
24 August 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 74601
24 March 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1429734
6 April 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1473541
20 May 1991
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224724
11 April 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 928311
21 March 1990
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 900926
22 March 1989
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036554
22 June 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016732
15 May 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028255
7 May 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1025183
27 April 1987
COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1028258
30 January 1987
Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1308909
9 April 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 989904
26 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983502
22 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276316
7 May 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275856
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 9 March 2006
Resolved
Provide test certificates for new transfer hoses.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2006
Resolution: Sighted test certificate.
Accommodation/Occupational Safety › Washroom/Toilet › Hot and Cold Running Water
Issued 9 March 2006
Resolved
Cap off plumbing for water closet.
Action required: 705 - Other - as specified
Resolved 30 March 2006
Resolution: plumbing capped.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 9 March 2006
Resolved
Replace panel cover for breaker in accomodation space.
Action required: 705 - Other - as specified
Resolved 30 March 2006
Resolution: Cover replaced.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 9 March 2006
Resolved
Blank off breakers that are unused in generator panel.
Action required: 705 - Other - as specified
Resolved 30 March 2006
Resolution: Blanks in place.
Accommodation/Occupational Safety › Potable Water System › General
Issued 9 March 2006
Resolved
Label aft stbd tank as NON-POTABLE water hatch.
Action required: 705 - Other - as specified
Resolved 30 March 2006
Resolution: Hatch stenciled.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 March 2006
Resolved
Repair link on fwd stbd railing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 March 2006
Resolution: Link replaced.
Deck/Cargo › Cargo Heating › General
Issued 9 March 2006
Resolved
Replace hydraulic control plate & wasted conections.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 March 2006
Resolution: Plate replaced.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 9 March 2006
Resolved
Re-paint draft marks.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 30 March 2006
Resolution: Repainted.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 March 2006
Resolved
Replace metal conduit for nav lights.
Action required: 705 - Other - as specified
Resolved 30 March 2006
Resolution: Repaired conduit.
Pollution Prevention/Response › Prevention Equipment › Oily Residue (sludge/slop) Tank
Issued 9 March 2006
Resolved
Pump out slop tank.
Action required: 705 - Other - as specified
Resolved 30 March 2006
Resolution: Done.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 9 March 2006
Resolved
Clean out excess oil under prime mover & generator.
Action required: 705 - Other - as specified
Resolved 30 March 2006
Resolution: Done.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 9 March 2006
Resolved
Clean out seals for 2 fwd stbd hatch covers.
Action required: 705 - Other - as specified
Resolved 30 March 2006
Resolution: Hatches resealed.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 9 March 2006
Resolved
Replace stanchions for deck rails, stbd fwd & aft.
Action required: 705 - Other - as specified
Resolved 30 March 2006
Resolution: Deck rail stanchions repaired.
Engineering › Gasoline Engine (auxiliary) › Camshaft (4 cycle)
Issued 9 March 2006
Resolved
Blank off open camshaft on prime mover.
Action required: 705 - Other - as specified
Resolved 30 March 2006
Resolution: Guard in place.
Stability › Intact Stability (when using lifting gear) › General
Issued 9 March 2006
Resolved
Repair/replace wasted spuds and support brackets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 March 2006
Resolution: Bad sections of spuds repaired.
Operations/Management › Pollution › Removal Methods/Procedures
Issued 31 May 2004
Resolved
Changes to VRP not approved.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 6 January 2006
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 5 March 2003
Resolved
Missing CG approval letter for vsl response plan
Action required: 705 - Other - as specified
Due 5 June 2003
Resolved 15 December 2005
Resolution: Approved VRP provided.
Engineering
Issued 27 April 1987
Resolved
FIX OR SUPPLY TFH DRAFT LOSS INTERLOCK SWITCH TO MEET 46 CFR 63.05-40(F). LABEL DISCONNECT SWITCH LOCATED ON TFH PANEL.
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987
Engineering
Issued 27 April 1987
Resolved
46 CFR 63.05-50 REQUIRES TWO FUEL CONTROL SOLANOID VALVES BE INSTALLED IN SERIES AND CONNECTED ELCTRICALLY IN PARALLEL. PRESENTLY THE VALVES ARE INSTALLED IN PARALLEL. PROVIDE ADDITIONAL VALVES TO MEET THE EQUIVALENCY ORINSTALL PRESENT VALVES IN SERIES & PROVIDE OPERATION OF EACH INDIVIDUALLY.
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987
Engineering
Issued 27 April 1987
Resolved
PROVIDE THERMAL FLUID HEATER (TFH) TEST PROCEDURES FOR [name withheld] (46 CFR 63.05-95(B)). ALSO PROVIDE APPROVED OIL TRANSFER PROCEDURES ABOARDTHE BARGE.
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987
Engineering
Issued 27 April 1987
Resolved
PROVIDE AUDIBLE AND VISUAL ALARMS FOR TFH FLAME SAFETY SYSTEM (IGNITION & FLAME FAILURE). SEE 46 CFR 63.05-35(A) AND 63.05-80(B) AND (C).
Condition: Unknown
Due 27 April 1987
Resolved 27 April 1987