FISH TALES

Built
1981
Last inspected
9 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCX 4073
Flag
UNITED STATES
Maury page id
psix-52975

Documentation record

Registered dimensions (L × B × D)60.0 ft × 18.6 ft × 8.3 ft
Registered tonnagegross 72 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA-1 MARINE INC · PANAMA CITY, FL, UNITED STATES · built 1981
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT ISABEL, TX
Endorsements, as the file codes themcw_un
DocumentationValid · issued 9 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72 - Regulatory (Subpart C or D), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 24 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 19

9 April 2026 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8330594
24 October 2025 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8258376
8 April 2025 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8090010
30 April 2024 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7881732
11 January 2024 Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7863460
5 December 2023 Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7834366
19 October 2023 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7791788
16 May 2023 Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7689754
18 February 2022 COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7398529
29 October 2021 Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7376939
5 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7190966
20 May 2020 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6965487
16 October 2019 Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6846386
15 May 2019 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6685709
2 May 2018 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6404610
13 October 2017 Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6294837
14 March 2017 Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6104571
21 February 2017 COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6092119
26 April 2016 Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5863618

Deficiency record · 24

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2026 Resolved
Repairs to the hull that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] observed crack in FRP hull approximately 6" below main deck on stbd side of transom. Internally on transom multiple locations of delamination of the FRP. Damaged wood brace in stbd quarter near deck. Submit Repair plan, and fix. *Limitations: Route reduced to Lakes, Bays, Sounds. No operation in seas over 3' or wind speed over 25knts. Vessels Captain is to check space for water intrusion prior to each trip.
Action required: 705 - Other - as specified
Resolved 16 April 2026
Resolution: MI attended vessel to observe repair. All sat.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 9 April 2026 Resolved
A vessel must be fitted with a FCC type accepted general marine radar system. MI was informed that the radar onboard was no longer operational. Repair or Replace. *Route reduced to Lakes, Bays, Sounds.
Action required: 705 - Other - as specified
Resolved 23 April 2026
Resolution: MI reviewed proof of def rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 April 2026 Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI found 02 life jackets unuseable and 04 missing. Replace. *Passengers allowed reduced to 100.
Action required: 705 - Other - as specified
Resolved 23 April 2026
Resolution: MI reviewed proof of def rectification.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 April 2026 Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. MI observed 03 life float lights to have expired batteries. Replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2026
Resolved 23 April 2026
Resolution: MI reviewed proof of def rectification.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 9 April 2026 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. MI observed no vent screen on tank vent. Replace. 46CFR182.20-35
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2026
Resolved 23 April 2026
Resolution: MI reviewed proof of def rectification.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2026 Resolved
All electrical installations shall be to the satisfaction of the Officer In Charge, Marine Inspections. MI observed one connection on the house battery and one on the stbd main engine to be corroded and have damaged strands. Renew connections. 46CFR183.01-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2026
Resolved 23 April 2026
Resolution: MI reviewed proof of def rectification.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 April 2026 Resolved
On a vessel of at least 26' in length, a visual and audible alarm must be provided at the operation station. MI observed lazarette light inoperable. Repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2026
Resolved 10 April 2026
Resolution: MI reviewed proof of def rectification.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 9 April 2026 Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33CFR159. MI observed overboard valve to not be secured closed as required by 33CFR159. Secure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 April 2026
Resolved 10 April 2026
Resolution: MI reviewed proof of def rectification.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 April 2025 Resolved
The owner or managing operator must provide satisfactory evidence of the required annual Fire Extinguisher servicing to the marine inspector. Marine Inspector found the fire extinguisher in the galley by fridge to have been missed during the annual servicing. Have extinguisher serviced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: Owner sent proof of deficiency rectification.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2025 Resolved
Portable Fire Extinguisher installation must be to the satisfaction of the Officer in Charge, Marine Inspection. Fire extinguisher stowed in the fwd galley space had a broken bracket. Replace or repair bracket.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 22 April 2025
Resolution: Owner sent proof of deficiency rectification.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 April 2025 Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Port side light and mast head light defective. Repair or replace.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 13 April 2025
Resolution: Owner sent proof of repair.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 April 2025 Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a) Installed eductor bilge system failed to operate. Repair and test. 46CFR182.25-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 10 April 2025
Resolution: MI received video evidence of bunk room and laz installed eductor bilge system working with no deficiencies identified. MI attended in person to confirm eng room suction also worked with no defeciencies.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 April 2025 Resolved
Each major generator shall be fitted with a name plate. Marine Inspector could not find data plate on generator to verify temperature rating. Procure data plate or derate generator. 46CFR183.10-5
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 15 April 2025
Resolution: MI attended vessel and observed new 60amp breaker in place of 100amp breaker and proper labeling showing the generator was derated.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 April 2025 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. One battery terminal for the generator battery had frayed conductors, one battery terminal for the port MDE had a cable conductors trimmed to fit the terminal connector, and one battery terminal for the port MDE was severely corroded causing the cable to overheat. Repair and replace cable ends appropriately. 46CFR183.01-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 April 2025
Resolved 10 April 2025
Resolution: MI attended vessel and observed new battery terminals with no deficiencies identified.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 30 April 2024 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The master did not have a valid medical certificate on board during the inspection. The vessels master shall have a valid medical certificate onboard. 46 CFR 10.301
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 29 May 2024
Resolution: Master showed proof of completion of mariners physical. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2024 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/ or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Vessel was found with an an unserviceable ground detection system. 46 CFR 183.05-30 (a) Do not use until approved by OCMI.
Action required: 705 - Other - as specified
Resolved 7 August 2024
Resolution: MI attended the vessel and inspected IAW MSC approved drawing. All sat.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 April 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline. Prove operation of the high water alarm during the next MI attendance prior to the carriage of passengers. 46 CFR 182.530
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 May 2024
Resolution: MI attended vessel and observed proper operation of bilge high water level indicators. All sat.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 May 2018 Resolved
missing three life jackets
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 May 2018
Resolved 15 May 2019
Resolution: replaced pfd
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 22 February 2017 Resolved
Total capacity of passengers and crew is reduced until life jackets can be provided for capacity on COI. Passenger and crew capacity reduced to 94.
Action required: 705 - Other - as specified
Resolved 14 March 2017
Resolution: Replaced 15 lofe jackets
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 February 2017 Resolved
Vessel is restricted from operation until drills have been conducted to the satisfaction of the attending USCG MI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2017
Resolution: conducted drills
Electrical › Electric Supply System (service) › Cable
Issued 22 February 2017 Resolved
12 volt battery cable for starboard engine must be replaced.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2017
Resolution: replaced cable
Engineering › Steering Gear System › Linkage
Issued 22 February 2017 Resolved
Steering ram needs cotter key in Lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2017
Resolution: replaced key
Electrical › Electrical Distribution System (service) › Cable
Issued 22 February 2017 Resolved
Vertically bind wire next to port engine in engine room.
Action required: 705 - Other - as specified
Due 1 March 2017
Resolved 22 February 2017
Resolution: installed verticle hangers
Electrical › Electrical Distribution System (service) › Cable
Issued 21 February 2017 Resolved
Butt connectors on high level alram needs to be replaced in Lazarette.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 February 2017
Resolution: added butt conectors