← All vessels
FISH TALES
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Heartland District (CGD-H) · Other hulls named FISH TALES
FISH TALES is a 1981 passenger vessel (inspected). The Coast Guard has recorded 97 inspections since 1981, most recently in April 2026, along with 133 deficiencies and 2 operational controls.
Records from 1981 to 2026. Most recent: inspection, 9 April 2026.
- Built
- 1981
- Last inspected
- 9 April 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 133 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
639514
WCX 4073
52975
Flag
UNITED STATES
367168580
Maury page id
psix-52975
Inspections, by type
…with no type recorded9
Years with a record
40 calendar years (1981–2026)
The 97 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)60.0 ft × 18.6 ft × 8.3 ft
Registered tonnagegross 72 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA-1 MARINE INC · PANAMA CITY, FL, UNITED STATES · built 1981
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT ISABEL, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it72 - Regulatory (Subpart C or D), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ6579MMSI 367168580 · active · compulsorily equipped · granted 11 July 2017, expires 11 July 2027
WCX4073MMSI 367168580 · expired · compulsorily equipped · granted 24 February 2007, cancelled 17 June 2017
WAG8781MMSI not assigned · expired · compulsorily equipped · granted 17 November 1994, cancelled 25 December 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 97
9 April 2026
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8330594
24 October 2025
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8258376
8 April 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 8090010
30 April 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7881732
11 January 2024
Initial Construction-Excluding Oversight · Plan Review "T" Boat
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7863460
5 December 2023
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7834366
19 October 2023
Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7791788
16 May 2023
Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7689754
18 February 2022
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7398529
29 October 2021
Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7376939
5 May 2021
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7190966
20 May 2020
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6965487
16 October 2019
Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6846386
15 May 2019
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6685709
2 May 2018
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6404610
13 October 2017
Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6294837
14 March 2017
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6104571
21 February 2017
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6092119
26 April 2016
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5863618
13 October 2015
Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5828724
25 March 2014
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4822570
21 February 2012
Deficiency Check · COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 4248419
20 February 2009
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3425494
4 April 2008
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3180537
26 February 2008
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3157415
7 December 2007
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3112690
16 October 2007
Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3084575
10 April 2007
Special · Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2904922
26 February 2007
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2877968
27 February 2006
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2594703
3 March 2005
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2305943
2 December 2004
Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2252610
30 August 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2181491
13 July 2004
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2135186
26 April 2004
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 2059069
8 April 2003
Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1773449
10 March 2003
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1755265
25 February 2002
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1489357
29 May 2001
Hull Examination
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 1062316
22 February 2001
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1444467
20 April 2000
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 817335
24 February 2000
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1379004
8 July 1999
Type not recorded
No type recorded · USCG Heartland District (dp) · USCG Heartland District (CGD-H) · Activity 717372
19 May 1999
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 799844
27 April 1999
Examination of Repairs
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1126625
18 April 1999
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 38896
18 April 1999
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1393139
18 April 1999
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 1510217
16 April 1999
Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1126624
5 April 1999
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 144046
23 February 1999
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1375707
10 March 1998
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1121469
23 February 1998
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1392870
8 October 1997
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1452336
30 April 1997
Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1095083
25 February 1997
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1368065
4 March 1996
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1077461
26 February 1996
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1081456
10 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1189457
4 August 1995
Deficiency Check · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1191558
8 December 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1162434
7 June 1994
Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1170856
20 October 1993
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 830346
21 June 1993
Deficiency Check · Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 846279
8 October 1992
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 949290
27 July 1992
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1265315
17 July 1992
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 946311
28 May 1992
Hull Examination · COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 949258
8 October 1991
Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1250291
16 September 1991
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1001944
9 July 1991
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 940946
4 October 1990
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 900131
1 August 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 908558
28 June 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1228514
6 June 1990
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 921166
6 June 1990
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1242612
3 May 1990
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 903699
18 April 1990
Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 906140
18 January 1990
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1246236
19 December 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 910319
21 November 1989
Inclining Experiment · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1238865
27 September 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 998186
1 September 1989
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1349156
15 August 1989
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1041869
26 July 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1043995
7 June 1989
COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1195050
8 February 1989
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1348296
20 December 1988
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1347718
1 November 1988
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 893943
12 August 1988
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1038480
8 June 1988
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1032705
1 October 1987
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1009092
17 June 1987
COI Inspection · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1314850
16 July 1986
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 991575
30 January 1986
Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 996971
24 July 1985
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1291867
19 August 1981
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 964025
Deficiency record · 133
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 April 2026
Resolved
Repairs to the hull that affect the safety of the vessel must not be made without the approval of the cognizant [name withheld] observed crack in FRP hull approximately 6" below main deck on stbd side of transom. Internally on transom multiple locations of delamination of the FRP. Damaged wood brace in stbd quarter near deck. Submit Repair plan, and fix.
*Limitations: Route reduced to Lakes, Bays, Sounds. No operation in seas over 3' or wind speed over 25knts.
Vessels Captain is to check space for water intrusion
prior to each trip.
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 9 April 2026
Resolved
A vessel must be fitted with a FCC type accepted general marine radar system. MI was informed that the radar onboard was no longer operational. Repair or Replace.
*Route reduced to Lakes, Bays, Sounds.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 April 2026
Resolved
An adult life jacket must be provided for each person carried on board a vessel. MI found 02 life jackets unuseable and 04 missing. Replace.
*Passengers allowed reduced to 100.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 9 April 2026
Resolved
Each item of lifesaving equipment with an expiration date on it must be replaced if the expiration date has passed. MI observed 03 life float lights to have expired batteries. Replace.
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 9 April 2026
Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. MI observed no vent screen on tank vent. Replace. 46CFR182.20-35
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 April 2026
Resolved
All electrical installations shall be to the satisfaction of the Officer In Charge, Marine Inspections. MI observed one connection on the house battery and one on the stbd main engine to be corroded and have damaged strands. Renew connections. 46CFR183.01-15(a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 April 2026
Resolved
On a vessel of at least 26' in length, a visual and audible alarm must be provided at the operation station.
MI observed lazarette light inoperable. Repair.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 9 April 2026
Resolved
A vessel with installed toilet facilities must have a marine sanitation device that complies with 33CFR159. MI observed overboard valve to not be secured closed as required by 33CFR159. Secure.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 April 2025
Resolved
The owner or managing operator must provide satisfactory evidence of the required annual Fire Extinguisher servicing to the marine inspector. Marine Inspector found the fire extinguisher in the galley by fridge to have been missed during the annual servicing. Have extinguisher serviced.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 April 2025
Resolved
Portable Fire Extinguisher installation must be to the satisfaction of the Officer in Charge, Marine Inspection. Fire extinguisher stowed in the fwd galley space had a broken bracket. Replace or repair bracket.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 April 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules. Port side light and mast head light defective. Repair or replace.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 April 2025
Resolved
All vessels shall be provided with bilge pumps in accordance with Table 182.25-10(a) Installed eductor bilge system failed to operate. Repair and test. 46CFR182.25-10
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 April 2025
Resolved
Each major generator shall be fitted with a name plate. Marine Inspector could not find data plate on generator to verify temperature rating. Procure data plate or derate generator. 46CFR183.10-5
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 April 2025
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. One battery terminal for the generator battery had frayed conductors, one battery terminal for the port MDE had a cable conductors trimmed to fit the terminal connector, and one battery terminal for the port MDE was severely corroded causing the cable to overheat. Repair and replace cable ends appropriately. 46CFR183.01-15
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 30 April 2024
Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. The master did not have a valid medical certificate on board during the inspection. The vessels master shall have a valid medical certificate onboard.
46 CFR 10.301
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2024
Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from fire caused by and/ or originating in electrical equipment, and reasonably safe from electrical shock of personnel. Vessel was found with an an unserviceable ground detection system.
46 CFR 183.05-30 (a) Do not use until approved by OCMI.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 30 April 2024
Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline. Prove operation of the high water alarm during the next MI attendance prior to the carriage of passengers.
46 CFR 182.530
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 2 May 2018
Resolved
missing three life jackets
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 22 February 2017
Resolved
Total capacity of passengers and crew is reduced until life jackets can be provided for capacity on COI. Passenger and crew capacity reduced to 94.
Operations/Management › Drills/Instruction › Not Conducted
Issued 22 February 2017
Resolved
Vessel is restricted from operation until drills have been conducted to the satisfaction of the attending USCG MI.
Electrical › Electric Supply System (service) › Cable
Issued 22 February 2017
Resolved
12 volt battery cable for starboard engine must be replaced.
Engineering › Steering Gear System › Linkage
Issued 22 February 2017
Resolved
Steering ram needs cotter key in Lazarette.
Electrical › Electrical Distribution System (service) › Cable
Issued 22 February 2017
Resolved
Vertically bind wire next to port engine in engine room.
Electrical › Electrical Distribution System (service) › Cable
Issued 21 February 2017
Resolved
Butt connectors on high level alram needs to be replaced in Lazarette.
Fire Fighting › Fire Pumps › Arrangement
Issued 6 April 2014
Resolved
Prove proper operation of fire pump. 46CFR 181.10-1
Lifesaving › Lifebuoys › Stowage
Issued 6 April 2014
Resolved
Provide corrosion resistant detachable clip for ring bouy waterlight. 46CFR 180.70 Vessel restricted to daylight operations.
Lifesaving › Lifebuoys › Serviceable
Issued 6 April 2014
Resolved
Renew retro-reflective tape on ring bouy. 46CFR180.70
Lifesaving › Buoyant Apparatus › Serviceable
Issued 6 April 2014
Resolved
Renew the four wooden paddles for two 15-man stbd lifefloats. 46CFR180.15-1 Vessel restricted to less than 3 miles from shore on limited coastwise route.
Stability › Unintentional Flooding › General
Issued 25 March 2014
Resolved
Prove proper operation of fixed bilge system. 46CFR 182.25-1
Documentation › Certificates/Documents › Stability Letter
Issued 27 February 2012
Resolved
Post stability letter. 46 CFR 176.306
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 February 2012
Resolved
Update Coast Pilot and Light lists. 46 CFR 184.420
Lifesaving › Lifefloat › Lifeline
Issued 27 February 2012
Resolved
Renew line for life floats holding baskets to life floats. 46 CFR 160.010. Vessel restricted to a lakes, bays, and sounds route until requirement is verified complete.
Engineering › Sea-water System (primary cooling) › Valve
Issued 27 February 2012
Resolved
Make repairs to secure loose port sea suction valve for MDE. 46 CFR 171.119
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 February 2012
Resolved
Conduct fire drill and man overboard drill in presence of CG inspector.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 27 February 2012
Resolved
Install grounding on port and stbd fuel fills. 46 CFR 182.
Documentation › Certificates/Documents › Stability Letter
Issued 20 February 2009
Resolved
Post Stability Letter.
Navigation › Piloting/Steering › Marine Charts
Issued 20 February 2009
Resolved
Place chart of operating area onboard vessel.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 20 February 2009
Resolved
Relabel pull station for fixed CO2 system to indicate extinguishing system is for engine room fire, to be activated only by the vessel's master or designated crew member. (pull for CO2 system is located in passenger cabin & only stated "pull in case of fire").
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 February 2008
Resolved
prove proper operation of stern light.
Communications › Alarms/Indicators › Bilge Alarm
Issued 26 February 2008
Resolved
Prove proper operation of laz. bilge high water alarm.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 26 February 2008
Resolved
Provide proof of enrollment in drug testing program.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 February 2008
Resolved
Restock expired items in 1st Aid kit.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 26 February 2008
Resolved
Provide copy of servicing report for fixed CO2 system to USCG inspector.
Communications › Radio Communications › EPIRB
Issued 26 February 2008
Resolved
Relocate EPIRB to an unobstructed location.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 26 February 2008
Resolved
Log monthly EPIRB testing & lifesaving equipment inspections.
Construction/Loadline › Structures › Deck Plating
Issued 16 October 2007
Resolved
Renew rotten plywood and framing above exhaust pipes in engine room.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 16 October 2007
Resolved
Repair leak in wet exhaust pipe.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 October 2007
Resolved
Install approved electrical wire supports where needed throughout vessel.
Lifesaving
Issued 24 February 2000
Resolved
REPAIR ALL FIVE LIFEFLOATS TO ORGINAL CONDITION. IAW 46 CFR 180.200
Navigation
Issued 24 February 2000
Resolved
REPLACE BOTH HYDRAULIC STEERING HOSES TO ENGINE._x001C_ _x001C_ _x001C_ _x001C_
Documentation
Issued 24 February 2000
Resolved
JOIN AN APPROVED DRUG TESTING CONSORTIUM THAT COMPLIES WITH ANNUAL DRUG SCREENING REQUIREMENTS. IAW 46 CFR 16.230
Lifesaving
Issued 24 February 2000
Resolved
PROVIDE SUITABLE RESCUE PLATEFORM. IAW 46 CFR 180.210
Construction/Loadline
Issued 24 February 2000
Resolved
PROVE OPERATION OF HIGH BILGE LEVEL ALARM AND LABEL SAME._x001C_ _x001C_ _x001C_ _x001C_
Construction/Loadline
Issued 24 February 2000
Resolved
REPAIR STDB RUBRAIL FROM BOW TO STERN AS NEEDED.
Lifesaving
Issued 24 February 2000
Resolved
INSTALL RETRO-REFLECTIVE TAPE TO RING BOUY. IAW 46 CFR 185.604 (H)._x001C_ _x001C_ _x001C_ _x001C_
Accommodation/Occupational Safety
Issued 27 April 1999
Resolved
Reweld and grind smooth welds on handrails.
Construction/Loadline
Issued 27 April 1999
Resolved
Bolt existing cleats to deck.
Construction/Loadline
Issued 27 April 1999
Resolved
Reweld deck supports in forepeak.
Accommodation/Occupational Safety
Issued 27 April 1999
Resolved
Rebolt ladder to 2nd deck on bow.
Fire Fighting
Issued 27 April 1999
Resolved
Install fixed CO2 system prior to carriage of passengers.
Lifesaving
Issued 23 February 1998
Resolved
RENEW RETROFLECTIVE TAPE ON 12 ADULT LIFE JACKETS.
Lifesaving
Issued 23 February 1998
Resolved
PLACE ONBOARD VESSEL COAST GUARD APPROVED FIRST AID KIT.
Unknown
Issued 23 February 1998
Resolved
OWNER TO VERIFIY CAPACITY OF PRESSURE VESSEL UNDER BRIDGE CONSOLE. IF TANKCAPACITY IS 5 CUBIC FEET OR OVER TANK MUST BE OPENDED FOR INSPECTION AND POP OFF VALVE TESTED.
Documentation
Issued 25 February 1997
Resolved
COMPLETE FCC REQUIRED INSPECTION AND PLACE ONBOARD VESSEL FCC RADIO SAFETY CERTIFICATE.
Lifesaving
Issued 4 August 1995
Resolved
Install one additional 15 person lifefloat. Total persons reduced to 97 until complete.
Lifesaving
Issued 7 June 1994
Resolved
Repair waterlight fo ring buoy.
Lifesaving
Issued 7 June 1994
Resolved
Lash paddles to inside netting on 3 lifefloats.
Navigation
Issued 7 June 1994
Resolved
Repair stern light.
Lifesaving
Issued 7 June 1994
Resolved
Provide 3 additional red flares.
Lifesaving
Issued 7 June 1994
Resolved
Provide 3 additional adult pfd's.
Engineering
Issued 7 June 1994
Resolved
Repair cable to starboard emergency fuel shutoff.
Fire Fighting
Issued 7 June 1994
Resolved
Repair engine driven fire pump.
Lifesaving
Issued 21 June 1993
Resolved
Repair one waterlight for lifefloat.
Construction/Loadline
Issued 21 June 1993
Resolved
Reinstall captive chain on aft deck hatch.
Engineering
Issued 21 June 1993
Resolved
Install heat shield on raycor filter.
Engineering
Issued 21 June 1993
Resolved
Open air receiver for internal exam.
Electrical
Issued 28 May 1992
Resolved
Repair emergency light in forward bunkroom. Bunkroom not to be used until completed.
Electrical
Issued 28 May 1992
Resolved
Install globe on light located port side in steering gear compartment.
Electrical
Issued 28 May 1992
Resolved
Clean corosion from battery terminals. (all 3 banks)
Lifesaving
Issued 28 May 1992
Resolved
Provide one additional adult PFD. Vessel is limited to not more than 132 total persons until completed.
Accommodation/Occupational Safety
Issued 9 July 1991
Resolved
FREE UP EMERGENCY ESCAPE HATCH FOR FWD ACCOMMODATION SPACE PRIOR TO CARRYING PASSENGERS IN THIS COMPT AND NO LATER THAN 16JUL91.
Lifesaving
Issued 9 July 1991
Resolved
REPLACE PAINTERS AND NETTING ON ALL LIFEFLOATS NO LATER THAN 09AUG91.
Engineering
Issued 6 June 1990
Resolved
MAKE PERMANEMT REPAIRS TO PORT FUEL TANK AND TEST TO 5 PSI, OR DISCONNECT FUEL PIPING & CAP OFF. DO NOT USE FOR FUEL UNTIL REPAIRED AND TESTED.
Engineering
Issued 6 June 1990
Resolved
PROPERLY LABLE STBD FUEL TANK REMOTE SHUTOFF VALVES.
Lifesaving
Issued 6 June 1990
Resolved
REPLACE ROTTED LIFELINE ON RING BOUY.
Lifesaving
Issued 6 June 1990
Resolved
PROVIDE TWO (2) RED HAND DISTRESS FLARES.
Electrical
Issued 6 June 1990
Resolved
PROVIDE GLOBE FOR PORT AFT LIGHT IN MACHINERY SPACE.
Construction/Loadline
Issued 3 May 1990
Resolved
CREDITED DRYDOCK DUE 03NOV91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE.
Construction/Loadline
Issued 18 April 1990
Resolved
DRYDOCK EXTENTION GRANTED THIS DATE. DRYDOCK DUE 01JUL90. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Navigation
Issued 21 November 1989
Resolved
RELOCATE EPIRB FLOAT FREE PRIOR TO CARRYING PASSENGERS.
Lifesaving
Issued 21 November 1989
Resolved
REPAIR 5 LIFEFLOAT LIGHTS PRIOR TO CARRYING PASSENGERS.
Electrical
Issued 21 November 1989
Resolved
REMOVE WASTED SWITCHBOARD DRIP SHIELD AND USE W.T. CABLE FITTINGS.
Fire Fighting
Issued 21 November 1989
Resolved
PROVIDE MARINE TYPE FIRE EXTINGUISER BRACKETS.
Engineering
Issued 21 November 1989
Resolved
PROVIDE HEAT SHIELDS - ALL RACOR FILTERS.
Deck/Cargo
Issued 21 November 1989
Resolved
PROVIDE MANUAL CONTROL OF ALL ELECTRIC BILGE PUMPS.
Lifesaving
Issued 21 November 1989
Resolved
STENCIL PFD STOWAGES BOTH DECKS.
Electrical
Issued 21 November 1989
Resolved
REMOVE EXTENSION CORDS ON WH DECK TOP AND NON W.T. LIGHTS HANGING ABOVE DECK.
Deck/Cargo
Issued 21 November 1989
Resolved
REPAIR E/R VENTS - LEAK AT MAIN DECK.
Electrical
Issued 21 November 1989
Resolved
REWIRE GALLEY.
Engineering
Issued 21 November 1989
Resolved
PROVIDE REMOTE FUEL SHUT-OFFS TO BE OPERABLE FROM ABOVE THE MAIN DECK.
Documentation
Issued 21 November 1989
Resolved
OPEN FOR EXAM PRESSURE VESSEL BY JUNE 90 (PER MI89020494).
Deck/Cargo
Issued 21 November 1989
Resolved
REMOVE AFT VENTS BELOW MAIN DECK AND INSTALL VENTS ABOVE MAIN DECK.
Engineering
Issued 21 November 1989
Resolved
INSTALL FLAME SCREENS ON FUEL VENTS, 30X30 PER INCH.
Electrical
Issued 21 November 1989
Resolved
REMOVE EXTENSION CORDS IN LAZARETTE.
Documentation
Issued 27 September 1989
Resolved
CONDUCT STABILITY TEST OR PROVIDE CALCULATIONS AS PER OCMI'S LETTER OF 15AUG89.
Lifesaving
Issued 26 July 1989
Resolved
PROVIDE 12' PENDENTS EACH 18" AROUND THE FOUR LARGE LIFE FLOATS. TO BE COMPLETED BY 30JUL89.
Lifesaving
Issued 26 July 1989
Resolved
PROVIDE PERMANENT SAFE MEANS TO ACCESS WHEELHOUSE ROOF AREA FOR LIFEFLOAT INSPECTION/LAUNCHING.
Lifesaving
Issued 7 June 1989
Resolved
STENCIL VSL NAME ON PADDLES. INSTALL 12' PENDENTS OF 3/8 DARK LINE AND MAKEWATERLIGHTS OPERATIONAL ON LIFEFLOATS. DON'T TIE WATERLIGHTS TO FRAMES. VSL LIMITED TO LAKES, BAYS AND SOUNDS.
Documentation
Issued 7 June 1989
Resolved
OBTAIN FCC RADIO SAFETY CERTIFICATE.
Navigation
Issued 7 June 1989
Resolved
HAVE SSB SERVICED FOR PROPER OPERATION.
Construction/Loadline
Issued 7 June 1989
Resolved
TEST AIR COMP. RELIEF VALVE FOR LIFT AND RESEAT PRESSURES.
Documentation
Issued 7 June 1989
Resolved
OPEN FOR EXAM PRESSURE VESSEL BY JUNE 90.
Accommodation/Occupational Safety
Issued 7 June 1989
Resolved
INSTALL EMERGENCY LIGHTING IN LOUNGE BELOW MAIN DECK THAT IS AUTOMATICALLY ACTUATED UPON FAILURE OF MAIN LIGHTING SYSTEM.
Lifesaving
Issued 7 June 1989
Resolved
PROVIDE WATERTIGHT CONTAINER FOR ALL FLARES AND REMOVE ALL EXPOSED FLARES FROM VSL.
Lifesaving
Issued 7 June 1989
Resolved
PROVID AND DEMONSTRATE ONBOARD STOWAGE OF ALL REQUIRED LIFEJACKETS. MAXIMUM35 UPPER DECK. NOT ALLOWED TO BE STOWED ON BUNKS.
Navigation
Issued 7 June 1989
Resolved
REPLACE SIDELIGHT LENSES PRIOR TO NIGHT OPERATION.
Construction/Loadline
Issued 7 June 1989
Resolved
FREE-UP EMERGENCY EXIT FROM LOWER LOUNGE.
Lifesaving
Issued 7 June 1989
Resolved
INSTALL LIGHTS FOR 60 ADULT AND 5 CHILD PFD'S AND REPAIR 5 ADULT PFD'S FOR STRAP AND PURCHASE TAPE FOR 3 PFD'S.
Lifesaving
Issued 7 June 1989
Resolved
PROVIDE 7 ADULT TYPE I PFD'S WITH LIGHT AND VSL NAME STENCILED PRIOR TO CARRYING MORE THAN 126 ADULT PERSONS.
Construction/Loadline
Issued 7 June 1989
Resolved
MAKE ENGINE DRIVEN FIRE AND BILGE PUMP OPERATIONAL PRIOR TO CARRYING PASSENGERS.
Construction/Loadline
Issued 7 June 1989
Resolved
PROVIDE HAND FIRE AND BILGE PUMP WITH ADEQUATE LENGTH SUCTION AND DISCHARGEHOSE.
Electrical
Issued 7 June 1989
Resolved
REPAIR PORT ENGINE ALARM.
Construction/Loadline
Issued 1 November 1988
Resolved
REGEL BROKEN GEL COAT ON HULL.
Lifesaving
Issued 1 November 1988
Resolved
STENCIL VSL NAME AND INSTALL LIGHTS TO NEW LIFEJACKETS.
Lifesaving
Issued 1 November 1988
Resolved
STENCIL THE NUMBER AND TYPE OF LIFEJACKETS AT ALL LIFEJACKET STORAGE UNITS.
Lifesaving
Issued 1 November 1988
Resolved
INSTALL A CG APPROVED BUOYANT APPARATUS OR LIFEFLOAT STENCILED WITH VSL NAME, ATTACHED TO VESSEL WITH 100' PAINTER AND PROPER SIZE FLOAT FREELINK AND A CG APPROVED WATERLIGHT PRIOR TO CARRYING MORE THAN 120 PERSONS COASTWISE.
Construction/Loadline
Issued 1 November 1988
Resolved
REINSTALL CAPTURE CHAIN TO AFT WEATHER DECK HATCH.
Construction/Loadline
Issued 1 November 1988
Resolved
CUT OUT ALL DELAMINATED OUTER GLASS LAYER AND REGLASS AS ORIGINAL PRIOR TO CARRYING PASSENGERS. A PICTURE OF REPAIR MAY BE TAKEN OF REPAIR BEFORE ANYCOATINGS AND SUBMITTED OR WAIT FOR A MARINE INSPECTOR TO EXAMINE.
Accommodation/Occupational Safety
Issued 1 November 1988
Resolved
PERMANENTLY INSTALL MISSING RAIL ON UPPER DECK.
Lifesaving
Issued 8 June 1988
Resolved
PROVIDE 7 ADULT TYPE I PFD'S WITH LIGHT AND VESSEL'S NAME STENCILED PRIOR TO CARRYING MORE THAN 126 ADULT PERSONS.
Documentation
Issued 8 June 1988
Resolved
OBTAIN FCC RADIO SAFETY CERTIFICATE.
Lifesaving
Issued 8 June 1988
Resolved
OBTAIN 6 ORANGE SMOKE SIGNALS.
Construction/Loadline
Issued 8 June 1988
Resolved
INSTALL CAPTIVE CHAINS FOR BOTH WEATHER DECK HATCHES.