Records from 2016 to 2026. Most recent: inspection, 10 February 2026.
Documentation record
Registered dimensions (L × B × D)100.6 ft × 26.0 ft × 12.0 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)100.6 ft × 26.0 ft × 12.0 ft
ITC tonnagegross 212 / net 63
BuilderOFFSHORE TRAWLERS INC · BAYOU LA BATRE, AL, UNITED STATES · built 1980
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPHILADELPHIA, PA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 9 February 2026 · expires 28 February 2027
Service, as the file records itOil Recovery
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
212 - Convention (Subpart B), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
63 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
10 February 2026
Deficiency Check · MSP Select Additional Oversight – Risk Assessment · Administrative Inspection · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8308502
12 August 2025
Deficiency Check · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8208050
30 July 2025
Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8198593
17 April 2025
MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8096697
25 March 2024
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7883472
27 March 2023
Periodic Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7657419
7 September 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7553555
22 March 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7412676
14 January 2021
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7124621
2 July 2020
Administrative Inspection · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6984396
3 March 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6919021
25 February 2019
Periodic Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6631826
20 February 2018
Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6358173
14 August 2017
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6222724
21 February 2017
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6089886
17 February 2016
Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 5816517
16 February 2016
Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5815516
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 February 2026
Resolved
Fire Detection systems, if installed must meet the requirements of PART 76. Fire panel displays a fault due to inoperable strobe lights/alarms when activated. Submit technician's report attesting to repairs prior to vessel operations. USCG re-attendance is requested once the system is fully operational.
Action required: 705 - Other - as specified
Resolved 19 February 2026
Resolution: Received documentation attesting to proper operation of the Fire Detection System.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 February 2026
Resolved
DAPI Program spot check was conducted during the COI Inspection and it is determined that the company shall schedule a DAPI audit with the USCG or submit documentation of the same conducted within 5 years to this office.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2026
Resolution: DAPI audit received and filed within the vessel's file. Deficiency cleared.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 February 2026
Resolved
Ring life buoy on port side has grab lines that wasted and worn. Replace grab lines.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 February 2026
Resolution: Captains statement received attesting to the renewal of the Ring Life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 27 March 2023
Resolved
The manufacturer's instructions for onboard maintenance of lifesaving appliances must be on board the vessel. The following must be provided for each appliance. Maintenance and repair instructions, A schedule of periodic maintenance, A log for records of inspections and maintenance. Immersion suits on board vessel were manufactured in 2002 and vessel operator was not able to provide evidence that manufacture's recommended maintenance was completed.
46CFR199.190(b)(1)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 8 May 2023
Resolution: Suits were inflated and tested as required
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 March 2023
Resolved
An inspection either general or partial depending upon the circumstances shall be made whenever any important repairs or alterations are undertaken. Vessel installed a new fire detection system during prior dry-dock. Operator provided approved plan review from MSC under subchapter T, however no CG oversight was completed during installation. Operator shall make vessel and fire detection available for oversight inspection.
46CFR91.45-5(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 8 May 2023
Resolution: System checked to approved plans by CGMI
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 27 March 2023
Resolved
In the event of alterations involving the safety of the vessel, the applicable plans shall be submitted for approval covering the proposed work except as modified by § 91.45-1. The general scope of the plans shall be as noted in § 91.55-5. Vessel installed a new fire detection system during prior dry-dock, however fire control plan has not been updated with new system. Operator shall update fire control plan to reflect vessel layout and submit plan for review to local OCMI.
46CFR91.55-10(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 April 2023
Resolved 8 May 2023
Resolution: Fire control plan updated
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 22 February 2021
Resolved
Bilge overboard discharge check valve fitted backwards preventing discharge of bilge system. Engineer to trouble shoot and demonstrate operation of overboard discharge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 23 February 2021
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 February 2021
Resolved
Low lube oil engine trip of port main engine not operational. Engine operator to trouble shoot and demonstrate operation of low LO trip.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2021
Resolved 22 February 2021
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 20 February 2018
Resolved
1. Provide valid certificate for vessels Drug and Alcohol Program.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 March 2018
Resolved 27 February 2018
Lifesaving › Hand Flares › Quantity
Issued 20 February 2018
Resolved
2. Provide 12 approved rocket parachute flares.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 March 2018
Resolved 27 February 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 21 February 2017
Resolved
The exhaust piping on the STBD main diesel engine is leaking. Make repairs and prove proper operation.
Due 21 July 2017
Resolved 21 April 2017
Resolution: Exhaust leak has fixed, witnessed operational test, all sat.
Communications › Radio Communications › EPIRB
Issued 21 February 2017
Resolved
Vessel did not possess an EPIRB. Vessel is not to operate beyond 3 nautical miles from shore until the EPIRB returns from servicing. 46 CFR 199.510(a)
Action required: 705 - Other - as specified
Resolved 22 February 2017
Resolution: EPIRB was onboard with a new battery and was tested satisfactory.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 February 2016
Resolved
Examination of the navigation lights found that the starboard running light lens is cracked. CG835 issued to place the lens.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 2 March 2016
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 17 February 2016
Resolved
Check of the air intakes and goose neck vents found that thye use studs and wing nuts to secure the covers, many of the wing nuts are missing and studs are painted over making it difficult to secure. CG835 issued to demonstrate proper operation and securing of all vents.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 2 March 2016
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 17 February 2016
Resolved
Issued CG-835 Prove proper operation of lube oil shut down on starboard generator.
Action required: 705 - Other - as specified
Due 29 February 2016
Resolved 2 March 2016