Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southwest District (CGD-SW) · Other hulls named SUNSET HORNBLOWER
SUNSET HORNBLOWER is a 1981 passenger vessel (inspected). The Coast Guard has recorded 106 inspections since 1981, most recently in June 2025, along with 193 deficiencies — 1 with no resolution recorded —, 7 operational controls and 2 casualty investigations between 2004 and 2010.
Records from 1981 to 2025. Most recent: inspection, 23 June 2025.
- Built
- 1981
- Last inspected
- 23 June 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Inspections
- 106
- Deficiencies
- 193 recorded · 1 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 2 investigations · 2004–2010
Identity
636835
WDF5955
52985
Flag
UNITED STATES
367469070
Maury page id
psix-52985
Inspections, by type
…with no type recorded17
Years with a record
42 calendar years (1981–2025)
The 106 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)98.0 ft × 23.4 ft × 6.3 ft
Registered tonnagegross 91 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · JEAN LAFITTE, LA, UNITED STATES · built 1981
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDF5955MMSI 367469070 · active · compulsorily equipped · granted 26 August 2020, expires 15 October 2030 · licensed under a name not among this hull’s recorded names (not shown)
WDA2451MMSI not assigned · expired · compulsorily equipped · granted 4 October 2000, cancelled 4 December 2010
WCU3587MMSI not assigned · expired · voluntarily equipped · granted 29 August 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 106
23 June 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8164992
16 January 2025
Deficiency Check · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8063025
11 June 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7932391
31 August 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7781299
16 May 2023
In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7689607
23 February 2023
Drydock Exam · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7641092
28 June 2022
Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7472303
29 September 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7323487
1 April 2021
Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7166810
26 February 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7146792
1 October 2020
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7069069
20 August 2019
MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6789097
6 August 2019
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6805001
24 January 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6613963
12 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6538703
10 September 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6537295
21 June 2017
Deficiency Check · COI Inspection · Administrative Inspection · Construction Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6199160
12 May 2017
Deficiency Check · Administrative Inspection · Examination of Repairs · Drydock Exam · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6174963
23 January 2017
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6075240
24 August 2016
Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5980316
24 September 2015
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5732913
26 June 2014
Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4900536
23 June 2012
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4352935
15 May 2012
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4321641
23 February 2012
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4249575
22 July 2011
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4090865
10 October 2010
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3868266
14 January 2010
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3663521
11 August 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3291616
12 July 2007
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2976957
26 June 2007
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2974070
12 June 2007
Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2966042
18 May 2007
DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2955634
13 February 2007
Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2871666
17 October 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2802981
25 July 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2720100
31 May 2006
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2666670
18 July 2005
Hull Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2424288
16 June 2005
Internal Structural Exam · Drydock Extension · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2376244
24 August 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2174017
21 July 2004
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2134371
9 June 2004
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2093573
8 June 2004
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2109346
17 October 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1929289
22 August 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1887466
5 August 2003
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1832492
27 May 2003
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1787283
3 March 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1748672
10 February 2003
Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1736977
15 January 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1731084
10 December 2002
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1718063
19 July 2002
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1648841
23 July 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384831
20 April 2001
Excursion Permit
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1469031
30 March 2001
Deadweight Survey · Inclining Experiment
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1413896
19 March 2001
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1395657
22 February 2001
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1435176
8 August 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1420380
21 July 1999
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1103125
14 June 1999
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1079059
3 June 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1360920
14 April 1999
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1393132
15 April 1998
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 789319
8 October 1997
Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1111196
9 April 1997
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1100789
15 October 1996
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1153471
20 October 1995
COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 884243
13 September 1995
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1422617
5 July 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177282
12 April 1994
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1168949
16 March 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 857703
2 February 1994
Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 851710
7 January 1994
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 850460
13 December 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444773
9 December 1993
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 849124
8 October 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 826538
24 August 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 847536
8 July 1993
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399886
15 April 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410803
8 September 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941412
3 August 1992
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1270949
7 July 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943607
4 December 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942740
23 July 1991
Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249039
26 June 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 920048
18 June 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902924
24 May 1990
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232908
29 December 1989
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 925164
29 December 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1229164
30 June 1989
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 898213
19 June 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202390
17 April 1989
Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1032317
7 July 1988
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 897657
23 June 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 893421
9 December 1987
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1308057
20 November 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1025688
4 November 1987
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332655
24 September 1987
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1005603
25 June 1987
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019764
21 December 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309410
21 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283984
21 December 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285199
12 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970394
6 April 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969069
12 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968873
17 June 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277385
Deficiency record · 193
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 23 June 2025
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Replace vent rings. (46 CFR 182.450(e))
02 - Structural Conditions › N/A - No Subsystem › Enhanced survey programme (ESP)
Issued 23 June 2025
No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel ... giving consideration to provisions for a seaworthy hull... and necessary facilities for passengers and crew. MI observed gaps and cracks in top longitudinal members in the vessel's liquor cabinet. Grind out and renew welds at next DDX. (46 CFR 177.100)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 June 2024
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartments under all practical conditions. MI observed the refrigerator condenser pipe dripping into a the bilge space below. MI requests plan proposal for tying this into an overboard discharge pipe by 25JUN2024.
46 CFR 182.25-1(a)(OLD-T)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 June 2024
Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. MI observed electrical conduit passing through a watertight boundary, underneath the dishwasher, with evidence of dishwasher fluid leaking past the conduit into the watertight space below. Repair watertight boundary to the satisfaction of the Marine Inspector.
46 CFR 171.114(a)(2)(Old-T)
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 11 June 2024
Resolved
Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. MI observed inadequate exhaust lagging on the starboard engine exhaust. Lagging needs to be reattached in order to cover the entire piping or protective grating installed.
46 CFR 182.15-20 (g)
(Old-T)
09 - Working and Living Conditions › 092 - Working Conditions › Adequate lighting - mooring arrangements
Issued 11 June 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment. MI observed a light fixture inoperable and another with a missing cover in the vessel's storeroom. Repair light fixtures to the satisfaction of the Marine Inspector.
46 CFR 176.806
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 June 2024
Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. MI observed the paddles in the forward/starboard buoyant apparatus with faded stenciling. Restencil paddles to the satisfaction of the Marine Inspector.
46 CFR 185.604 (g)
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 11 June 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: inspection of all accessible parts of the interior of the hull and the watertight bulkheads. MI observed small cracks in the starboard steering compartment, on the forward peak, on top of the stem. Vessel must repair the cracks prior to next credit drydock.
46 CFR 176.802 (a)(1)
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 August 2023
Resolved
Fire hydrants, when required, shall be of sufficient number and so located that any part of the vessel may be reached with an effective stream of water from a single length of hose. Hole in fire main found in void #2. Repair fire main piping to the satisfaction of the attending marine inspector.
46 CFR 181.15-5(a)
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 August 2023
Resolved
Penetrations and openings in watertight bulkheads must have means of making them watertight. Void #1 stbd side wire transit penetration is not watertight. Seal wire transit to the satisfaction of the attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 August 2023
Resolved
Penetrations and openings in watertight bulkheads must have means of making them watertight. Engine room / Generator bulkhead high port side penetration is not watertight. Seal penetration to the satisfaction of the attending marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 August 2023
Resolved
An inspection for renewal of a certificate of inspection in conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It includes inspection and testing of the structure, machinery, equipment, and drills. The vessel must conduct a satisfactory man overboard drill, fire drill, and have their machinery, equipment, and structure inspected and tested underway.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 August 2023
Resolved
Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout accommodation spaces. (1) Each stowage container for life jackets must not be capable of being locked. If practicable, the container must be designed to allow the life jackets to float free. Stowage areas of lifejackets were found to have locks that would compromise the ability to be float free. Repair the stowage areas to the satisfaction of the attending Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 August 2023
Resolved
The bilge pipe piercing the collision bulkhead shall be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from above the weather deck. Bilge piping piercing FWD of collision bulkhead screw down valve inoperable. Vessel completed repairs and operationally tested to the satisfaction of the marine inspector.
46 CFR 182.25-5(d)
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 31 August 2023
Resolved
Each inflatable liferaft, inflatable buoyant apparatus, life float, and buoyant apparatus on the vessel on March 11, 1996, may be used to meet the requirements of this part for these survival craft as long as the survival craft is continued in use on the vessel, and is in good and serviceable condition. Life floats orange color was faded from dirt and age. Vessel to clean dirt from life floats to the satisfaction of the attending marine inspector. Vessel cleaned life floats to the satisfaction of the marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 28 June 2022
Resolved
An interior or exterior opening that is temporarily closed by cover plates or boards held in place only by hook bolts is considered open to the weather. Hook bolts were not visible and additional paneling material has been added to the interior of the tonnage door. Make corrections at next credit drydock.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 June 2022
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Diesel fuel supply piping is connected to the fire main piping with a closed valve and temporary lock-out tag preventing contamination. Permanent means for segregation must be made at next credit drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 June 2022
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments. Bilge pump in the engine compartment was not operable.
46 CFR 182.25-1(a) OLD T
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 September 2021
Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Aluminum hull vessels: Lloyd's Yachts and Small Craft; or For a vessel of not more than 30.5 meters (100 feet) in length: ABS Steel Vessel Rules (<61 Meters), with the appropriate conversions from the ABS Aluminum Vessel Rules. One inch crack found on port and starboard sides where the second transverse frame meets the first longitudinal frame.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 September 2021
Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. The port rudder shaft seal was leaking at a rate of approximately one half gallong per minute while underway. The operator tightened the packing gland to the satisafction of the Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2021
Resolved
A vessel exposed to salt water more than three months in any 12 month period must undergo a drydock and internal structural examination at least once every two years. Vessel has failed to schedule drydock and internal structural examination within two years of last drydock as listed on the COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 October 2020
Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Valve for forepeak bilge is inoperable.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2019
Resolved
Except as otherwise provided in this paragraph, all engine exhaust pipes must be water cooled. Vessel's port engine exhaust cooling was leaking at a rate of approximately 1 drop/5 seconds while underway. Repair the exhaust cooling leak.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 24 January 2019
Resolved
Cracked weld on starboard side of Frame 14, where the deck meets the frame. Repair prior to dry dock completion.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018
Resolved
IMO: Vsl is broadcasting invalid IMO #, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 11 September 2018
Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. Call sign incorrect; update registration. 47 CFR 80.1061(f)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 September 2018
Resolved
Provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from electrical shock of personnel. Dead-end wire found in engine room below A/C chill water pump junction box. Connected to electrical panel, breaker taped off, however could accidentally be energized; remove wire. 46 CFR 183.01-5
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 September 2018
Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters at least 1 inch high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. Labeling on both QAWTD illegible due to fading color; replace labeling.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 September 2018
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. NTM available, but charts not updated since February 2018; correct charts.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 September 2018
Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Pitting found at the intersection of Frame 1 and the first longitudinal bulkhead. Rectify deficiency during next drydock inspection. 46 CFR 177.01-5
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 September 2018
Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Weld crack found on the starboard side at the intersection of Frame 14 and the connection to the deck. Rectify deficiency during next drydock inspection. 46 CFR 177.01-5
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 August 2017
Resolved
Provide proof of purchase for the approved man overboard net demonstrated to the Coast Guard on 08/01/2017.
Engineering › Bilge Water Management System › Pump
Issued 6 July 2017
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Vessel shall demonstrate the proper operation of the bilge system at 50 gallons per minute. 46 CFR 182.25-10(a) (Old T)
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 July 2017
Resolved
Crew shall demonstrate adequate means to recover injured or unconcious man overboard. 46CFR185.420(a)
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 28 June 2017
Resolved
1) Replace the 12” wide vertical ladder leading from the large (4’x6’) escape hatch on the second deck into the aft starboard corner of the main deck with the originally approved installation. Remove all stored items currently preventing the quick escape of passengers to the satisfaction of the attending marine inspector. 46CFR177.15-1
Engineering › Bilge Water Management System › Piping
Issued 12 May 2017
Resolved
Repair small leak in the bilge system directly in front of the starboard main engine.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 May 2017
Resolved
New strainer for the generator is not in compliance with CVC Policy 16-02 and is not accepted. Provide plan for the renewal of the strainer and replace current strainer with compliant strainer.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 May 2017
Resolved
All raw water systems were utilizing only single hose clamps, double clamps must be added per 46CFR182.720(e)(3)(v)(B).
Construction/Loadline › Hull › Side Shell
Issued 29 July 2014
Resolved
Submit repair proposal for through-hull penetrations in way of stbd exhaust hull penetration.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 29 July 2014
Resolved
Provide working gauges for generators.
Stability › Watertight Integrity › General
Issued 29 July 2014
Resolved
Properly seal/cap penetrations: under engine room. watertight door, stbd side near the overhead in between main engine room and generator room.
Documentation › Markings/Placards › Capacity Marking
Issued 29 July 2014
Resolved
Renew 02 deck placards to restrict total persons to 66 IAW vessel's stability letter.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 29 July 2014
Resolved
Make proper temp repairs to the MSD tank at identified locations to stop leaking.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 29 July 2014
Resolved
Provide repair proposal for permanent repairs to MSD tank. Permanent repairs shall be completed during next available drydock.
Lifesaving › Lifefloat › Serviceable
Issued 29 July 2014
Resolved
Make primary lifesaving equipment available for inspection upon removal of protected species.
Electrical › Electric Supply System (service) › Cable
Issued 23 June 2012
Resolved
Prpoerly terminate dead ended wires in void under galley.
Engineering › Pressure Vessel › Relief Valve
Issued 23 June 2012
Resolved
Complete a test of the pressure relief valve on STBD pressure vessel.
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 23 June 2012
Resolved
Provide a suitable cover for battery box installation
Electrical › Lighting (service) › Lighting Fixture
Issued 23 June 2012
Resolved
Provide a suitable cover over lights in captain and crew state rooms.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012
Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012
Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16.
Engineering › Bilge Water Management System › Piping
Issued 25 July 2011
Resolved
Found hole in bilge piping from suction side of PTO Bilge Pump. Repair in kind and proce proper operation to the satisfaction of the attending marine inspector.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 25 July 2011
Resolved
Found excessive sludge in bottom of start air receiver. Make receiver ready for proper internal inspection.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 25 July 2011
Resolved
Provide serviced B-II fire extinguisher in engine room.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 January 2010
Resolved
Repair fasteners on two noted lifejackets on the upper deck.
Communications › Radio Communications › EPIRB
Issued 14 January 2010
Resolved
Provide onboard Catagory I EPIRB.
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 14 January 2010
Resolved
Prove proper operation of engine room blowers.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 August 2008
Resolved
Emergency light fixture was missing light bulb. This is the light that shows the path to the emergency escape hatch. Fixed on the spot.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 11 August 2008
Resolved
Emergency escape hatch was not marked as such and is located behind the switch board making it hard to find. Fixed on the spot.
Lifesaving › Lifebuoys › Stowage
Issued 11 August 2008
Resolved
The throwable life ring did not have a corrosion resistant clip connecting it to the light. It was tied on. Corrected on the spot.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 July 2007
Resolved
Correct vessel owner on certificate of documentation.
Stability › Watertight Integrity › General
Issued 12 July 2007
Resolved
Seal hole in lazarette/engine room bulkhead to make watertight.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 July 2007
Resolved
Make repairs to fluorescent lighting fixture in captain's cabin.
Documentation › Logs/Records › Drug Test Records
Issued 18 May 2007
Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently enrolls new employees in its contracted drug testing consortium on a quarterly basis, rather than at the time of hiring.
Documentation › Logs/Records › Drug Test Records
Issued 18 May 2007
Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently is waiving random drug testing for some employees, based upon their participation in another unaffiliated company.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 13 February 2007
Resolved
Prove proper operation of lazarette bilge high level alarm.
Engineering › Fuel Oil Service System › Piping
Issued 13 February 2007
Resolved
Repair fuel leak on port #2 generator fuel line.
Lifesaving › Lifefloat › Float-free Link
Issued 13 February 2007
Resolved
Properly connect life floats to weak link.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 25 July 2006
Resolved
Install emergency escape exit signs for engine room and lazarette In Accordance with 46 CFR 122.606
Lifesaving › Lifefloat › Serviceable
Issued 25 July 2006
Resolved
Make repairs/replace all lifefloats.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2006
Resolved
Dead end all identified wires outboard port generator next to battery banks.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 July 2006
Resolved
Renew expired eye wash In Accordance with 46 CFR 160.041
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 25 July 2006
Resolved
Post lifejacket donning on second deck near lifejacket stowage area.
Fire Fighting › Fire Main › Pressure
Issued 25 July 2006
Resolved
Prove proper operation for installed firemain system IAW 46 CFR 118.300
Construction/Loadline › Hull › Weld
Issued 21 July 2004
Resolved
Make repairs to cracked welds at base of spray shield starboard side of the focsle.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 21 July 2004
Resolved
Remove items that are a possible fire hazard from the top of the galley range vents.
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 21 July 2004
Resolved
Replace light in refer space.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 July 2004
Resolved
Repair exhaust leak on port side generator prior to using generator.
Electrical › Electric Supply System (service) › Cable
Issued 21 July 2004
Resolved
Remove wire nuts or place in a junction box, wire connections on aft bulkhead below galley deck.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 July 2004
Resolved
Replace glass globes in lighting fixtures in engine room and lazarette.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 July 2004
Resolved
Provide metallic wire supports for wiring on overhead in engine room.
Engineering › Compressed Air System (control)
Issued 22 August 2003
Resolved
Provide safety guard for rotating machinery on starboard air compressor.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 5 August 2003
Resolved
Prove operation of all installed smoke detectors on main deck.
Lifesaving › Buoyant Apparatus
Issued 5 August 2003
Resolved
Replace 1 missing paddle.
Lifesaving › Buoyant Apparatus
Issued 5 August 2003
Resolved
Replace retro on life floats.
Lifesaving › Buoyant Apparatus
Issued 5 August 2003
Resolved
Replace pendant on life float.
Fire Fighting › Fire Pumps
Issued 5 August 2003
Resolved
Provide hand fire pump.
Engineering › Bilge Water Management System
Issued 5 August 2003
Resolved
Replace check valve in bilge line leading to compartment forward of collision bulkhead.
Engineering › Bilge Water Management System
Issued 5 August 2003
Resolved
Add strainer to bilge suction in compartment forward of engine room.
Engineering › Bilge Water Management System
Issued 5 August 2003
Resolved
Label bilge handle for fore peak bilge valve.
Engineering › Compressed Air System (control)
Issued 5 August 2003
Resolved
Demonstrate proper operation of pressure relief valve. LEGACY COMPONENT DESC: Compressor
Electrical › Electric Supply System (service)
Issued 5 August 2003
Resolved
Provide plans to replace all welding cable in DC electrical system with marine grade battery cable. LEGACY COMPONENT DESC: Battery Conductor
Electrical › Electrical Distribution System (service)
Issued 5 August 2003
Resolved
Remove dead wire on outboard side of stbd generator.
Construction/Loadline › Penetrations › Valve Flange
Issued 27 May 2003
Resolved
Renew starboard side aft condensor thru hull fitting spool piece.
Construction/Loadline › Hull
Issued 27 May 2003
Resolved
Crop and renew shell plate in way of stbd side aft condensor overboard as indicated by the attending marine inspector. LEGACY COMPONENT DESC: Hull Plating
Construction/Loadline › Hull › Hull Plating
Issued 27 May 2003
Resolved
Renove fairing compound in way of port side fwd and make area available for inspection.
Engineering
Issued 27 May 2003
Resolved
Clean and prep starboard shaft keyway for inspection.
Stability › Watertight Integrity
Issued 27 May 2003
Resolved
Install captive chain on forward peak scuttle.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 27 May 2003
Resolved
repair as new exhaust system, ports side aft in way of FRP repairs.
Construction/Loadline › Penetrations › Valve Flange
Issued 27 May 2003
Resolved
Make all sea valves available for inspection.
Electrical
Issued 27 May 2003
Resolved
Repair as new motor in way of stbd side aft air compressor.
Engineering › Compressed Air System (start air)
Issued 10 February 2003
Resolved
Make port air receiver located in generator/steering gear compartment available for inspection IAW 46 CFR 61.10. Pressure vessel is greater than 5 cubic feet in size and must be either internally examined or hydrostatically tested to the satisfaction of attending marine inspector. LEGACY COMPONENT DESC: Compressor
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 10 February 2003
Resolved
Properly lock MSD to prevent accidental discharge.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 10 February 2003
Resolved
Clean up the small amount of oil located in engine room bilge.
Engineering › Fuel Oil Service System
Issued 10 December 2002
Resolved
Submit proposal to install new fuel oil fill lines to service the starboard fuel oil tank from the port side of the vessel.
Engineering › Fuel Oil Service System
Issued 10 December 2002
Resolved
Discontinue the use of the vessel's upper fuel oil tanks as service tanks. The tanks may be used as storage tanks only.
Electrical
Issued 19 July 2002
Resolved
Remove electrical tape connections in battery charger wires in lazarette. LEGACY COMPONENT DESC: Wiring
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 July 2002
Resolved
Update Coast Pilot. (2000 version onboard)
Stability › Watertight Integrity
Issued 19 July 2002
Resolved
Remove old MSD supply line (pvc) and repair the hole in the bulkhead.
PVC pipe ran through hole in watertight bulkhead with no fitting.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 July 2002
Resolved
Renew expired aspirin in first aid kit.
Documentation › Logs/Records
Issued 19 July 2002
Resolved
Log periodic EPIRB tests.
Construction/Loadline
Issued 3 June 1999
Resolved
INSTALL HOLDING CHAIN ON HATCH COVER FOR FORE PEAK.
Lifesaving
Issued 3 June 1999
Resolved
RENEW HYDROSTATIC RELEASE FOR EPIRB.
Construction/Loadline
Issued 3 June 1999
Resolved
PROVE PROPER OPERATION OF AUDIBLE ALARM FOR BILGE HIGH WATER INDICATOR ON BRIDGE.
Lifesaving
Issued 3 June 1999
Resolved
INSTALL SAFETY CHAINS ON BRIDGE WINGS.
Lifesaving
Issued 3 June 1999
Resolved
INSTALL RETROREFLECTIVE TAPE ON RING BUOYS.
Lifesaving
Issued 3 June 1999
Resolved
PROVIDE AND DISPLAY PFD DONNING PLACARDS.
Navigation
Issued 3 June 1999
Resolved
PROVIDE AND POST EMERGENCY RADIO PLACARD.
Engineering
Issued 3 June 1999
Resolved
INSTALL FLAME IMPINGEMENT BOWL ON AFT RACOR FILTER FOR STARBOARD MAIN ENGINE.
Electrical
Issued 9 April 1997
Resolved
INSTALL RESPECTIVE ELECTRICAL PARTS SUCH AS WIRE NUTS, BOX COVERS AND BRACKETS TO THE ENGINEROOM ELECTRICAL COMPONENTS.
Construction/Loadline
Issued 9 April 1997
Resolved
REMOVE THE FIXED STRAINER VICINITY OF THE FORWARD STBD SIDE FOR CLOSER EXAMINATION OF THE SEA CHEST INTERNALS.
Construction/Loadline
Issued 9 April 1997
Resolved
MAKE OPERABLE THE ESCAPE SCUTTLE DOGGING MECHANISM FOR EXITING THE ENGINE ROOM.
Construction/Loadline
Issued 9 April 1997
Resolved
MAKE OPERABLE THE ESCAPE SCUTTLE DOGGING MECHANISM FOR EXITING THE STEERINGGEAR COMPT.
Electrical
Issued 9 April 1997
Resolved
RE-ATTACH ELECTRICAL BOX/CONDUIT TO THE REEFER COMPRESSOR LOCATED ON THE PORT SIDE BELOW THE GALLEY.
Construction/Loadline
Issued 9 April 1997
Resolved
RESTORE THE FWD STEERING GEAR COMPT BULKHEAD TO WATERTIGHT INTEGRITY BY PERMANENTLY PLUGGING HOLES THAT HAD BEEN DRILLED AND SEALING AROUND ESTABLISHED WIRE RUN PENETRATIONS.
Construction/Loadline
Issued 9 April 1997
Resolved
MAKE PERMANENT REPAIRS TO THE CRACKED WELD OF THE FAIRING TO THE PORT SHAFT
Construction/Loadline
Issued 9 April 1997
Resolved
REMOVE POROSITY FROM EXISTING WELD AND APPLY NEW WELD TO THE PORT STRUT INBOARD LEG.
Construction/Loadline
Issued 9 April 1997
Resolved
REMOVE FIXED STRAINER VICINITY OF THE PORT AFT INBOARD BOTTOM FOR CLOSER EXAMINATION OF THE SEA CHEST INTERIOR.
Documentation
Issued 15 October 1996
Resolved
PROVIDE PROOF OF ENROLLMENT OF CREW IN A RANDOM DRUG TESTING PROGRAM.
Lifesaving
Issued 20 October 1995
Resolved
RELOCATE WATERLIGHTS FROM MAST TO READILY ACCESSIBLE POSITION.
Construction/Loadline
Issued 20 October 1995
Resolved
PROVIDE ADEQUATE CLOSURES AND SAFETY CHAINS FOR MAIN DECK DOORS AFT.
Construction/Loadline
Issued 20 October 1995
Resolved
POST WARNING LABEL MAIN DECK DOOR AFT, DO NOT OPEN WHEN PASSENGERS ARE ON BOARD.
Engineering
Issued 20 October 1995
Resolved
LABEL FUEL AND WATER FILL PIPES AND VENTS.
Documentation
Issued 20 October 1995
Resolved
PROVIDE VALID FCC RADIO TELEPHONE SAFETY CERTIFICATE.
Documentation
Issued 20 October 1995
Resolved
PRODUCE VALID FCC RAQDIO TELEPHONE OPERATORS LICENSE.
Lifesaving
Issued 20 October 1995
Resolved
PROVIDE PROPER WEAK LINKS FOR LIFE FLOATS.
Lifesaving
Issued 20 October 1995
Resolved
DEMONSTRATE THE ABILITY TO LIFT A PERSON FROM THE WATER TO THE RAIL DURING DRILLS.
Lifesaving
Issued 20 October 1995
Resolved
LABEL LIFE JACKET STORAGE LOCKERS.
Lifesaving
Issued 20 October 1995
Resolved
PERMENANTLY MOUNT BRACKETS FOR LIFE FLOAT WATERLIGHTS.
Navigation
Issued 5 July 1994
Resolved
REMOVE INOPERABLE RADAR FM PILOT HOUSE.
Unknown
Issued 5 July 1994
Resolved
PROVIDE EVIDENCE OF ENROLLMENT IN CHEMICAL TESTING PROGRAM IAW 46 CFR SUBCHAPTER A.
Electrical
Issued 5 July 1994
Resolved
REMOVE DEAD END WIRES IN PILOT HOUSE, [name withheld], OFFICE, ENGINE ROOM AND STORAGE ROOM.
Navigation
Issued 5 July 1994
Resolved
REPLACE RUDDER ANGLE INDICATOR IN ENGINE ROOM.
Electrical
Issued 5 July 1994
Resolved
PROVIDE ADDITIONAL EMERGENCY LIGHT IN ENG ROOM.
Lifesaving
Issued 5 July 1994
Resolved
PROVIDE I ADDITONAL ADULT SIZE LIFE JACKETS. VSL PROHIBITED FROM OPERATINGWITH MORE THAN 161 PERSONS UNTIL REQUIREMENT CLEARED.
Lifesaving
Issued 5 July 1994
Resolved
MARK EMERGENCY EXIT IN CAPTAIN'S CABIN.
Construction/Loadline
Issued 5 July 1994
Resolved
REPAIR REACH ROD IN FORE PEAK.
Lifesaving
Issued 13 December 1993
Resolved
PROVIDE ON BOARD COAST GUARD APPROVED LIFE FLOATS OR BOUYANT APPARATUS._x001C_ VESSEL IS RESTRICTED TO SERVICE NOT MORE THAN ONE MILE FROM LAND.
Lifesaving
Issued 9 December 1993
Resolved
PROVIDE RESCUE BOAT WHEN PASSENGERS ARE ABOARD AND VESSEL IS ENGAGED IN DOCKSIDE RESTAURANT OPERATIONS.
Lifesaving
Issued 8 July 1993
Resolved
Repair or replace both life floats.
Accommodation/Occupational Safety
Issued 8 July 1993
Resolved
Replace existing dryer vent (plastic) with metal type vent.
Engineering
Issued 8 July 1993
Resolved
Remove and replace existing plastic tubing on fuel oil service to port generator prime mover with hard piping.
Electrical
Issued 7 July 1992
Resolved
REMOVE LOOSE DEAD-END CIRCUIT IN GENERATOR/STEERING SPACE BELOW WATERTIGHT DOOR.
Navigation
Issued 7 July 1992
Resolved
MAKE PROPER REPAIRS TO STBD HYDRAULIC STEERING RAM TO STOP LEAKAGE OF HYDRAULIC FLUID.
Navigation
Issued 7 July 1992
Resolved
PROVIDE VSL WITH USCG APPROVED, OR UL TO CURRENT STANDARDS, NAVIGATION LIGHTS.
Lifesaving
Issued 7 July 1992
Resolved
REMOVE OIL FROM BILGE AND DISPOSE AT PROPER SHORE SIDE FACILITY.
Electrical
Issued 7 July 1992
Resolved
PROVIDE GLOBE AND PLASTIC COVER FOR LIGHTING FIXTURES IN ENGINE ROOM.
Accommodation/Occupational Safety
Issued 7 July 1992
Resolved
CLEAN STOVE HOOD SCREENS IN GALLEY AND REPLACE (1) MISSING SCREEN.
Lifesaving
Issued 7 July 1992
Resolved
POST EMERGENCY CHECK-OFF LIST AND PFD DONNING INSTRUCTIONS.
Electrical
Issued 7 July 1992
Resolved
PROVIDE COVER FOR ELECTRICAL CONNECTION/JUNCTION BOX ON STBD HULL IN ENGINEROOM.
Navigation
Issued 7 July 1992
Resolved
MAKE PROPER REPAIRS TO PORT STEERING RUDDER STUFFING TO STEM FLOW OF WATER DRIPPING INTO COMPARTMENT.
Engineering
Issued 23 July 1991
Resolved
PROVIDE FUEL FILTER FLAME REFLECTOR AND VACUUM GAUGE ON STBD GENERATOR.
Construction/Loadline
Issued 23 July 1991
Resolved
REMOVE OIL WASTE FROM BILGE.
Engineering
Issued 23 July 1991
Resolved
PROVIDE 30 X 30 MESH SCREENS ON ALL FUEL VENTS.
Construction/Loadline
Issued 23 July 1991
Resolved
REPAIR FOREPEAK BILGE VALVE AND PROVE PROPER OPERATION.
Lifesaving
Issued 23 July 1991
Resolved
PROVIDE THE FOLLOWING FOR THE LIFE FLOATS:1-OAR, REPLACE TEHTER LINE, PROPERLY FASTEN WEAK LINK TO VESSEL, PROPERLY FAKE PAINTER.
Fire Fighting
Issued 23 July 1991
Resolved
PROVIDE TWO TYPE:B SIZE:II FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_
Navigation
Issued 23 July 1991
Resolved
PROVIDE UP TO DATE CHARTS & T-BOAT REGULATIONS. _x001C_ _x001C_ _x001C_
Fire Fighting
Issued 23 July 1991
Resolved
LABEL FIRE STATIONS #2 AND #3.
Fire Fighting
Issued 23 July 1991
Resolved
PROVIDE FIRE EXTINGUISHER BRACKET FOR EXTINGUISHER LOCATED IN ENGINE ROOM._x001C__x001C_ _x001C_
Navigation
Issued 18 June 1990
Resolved
PROVIDE A NEW BATTERY FOR EPIRB.
Lifesaving
Issued 18 June 1990
Resolved
PROVIDE 6 HAND RED FLARE DISTRESS SIGNALS.
Navigation
Issued 18 June 1990
Resolved
PROVIDE UPDATED COAST PILOT ACCORDANCE WITH 46 CFR 185.20-35.
Engineering
Issued 18 June 1990
Resolved
VESSEL'S TWO AIR RECEIVERS MUST BE VISUALLY INSPECTED OR HYDROTESTED.
Construction/Loadline
Issued 30 June 1989
Resolved
PROVIDE PORT & STARBOARD BOW MARKINGS WHICH DISPLAY VESSEL NAME CLEARLY ANDCONTRASTING TO THE HULL IN MINIMUM 4" LETTERS.
Electrical
Issued 19 June 1989
Resolved
REMOVE ALL HOUSEHOLD SCREWED WIRE FITTINGS ON UPPER DECK INSIDE BAR AREA, REPLACE WITH CRIMPED/SOLDERED TYPE.
Lifesaving
Issued 19 June 1989
Resolved
REPLACE ALL DETERIORATED TAG LINES AND WATERLIGHT LINES ON LIFEFLOATS.
Lifesaving
Issued 19 June 1989
Resolved
PROVIDE 8 ADULT LIFE PRESERVERS USCG APPROVED. UNTIL THIS REQUIREMENT IS SATISFIED TOTAL NUMBER OF PERSONS ALLOWED IS REDUCED TO 154.
Electrical
Issued 19 June 1989
Resolved
REPAIR AS NEEDED AND PROVE OPERATION OF EMERGENCY LIGHTING ON UPPER DECK.
Engineering
Issued 23 June 1988
Resolved
INSTALL FLAME SHIELDS ON ALL FUEL OIL FILTERS FOR MAIN ENGINES AND GENERATORS.
Electrical
Issued 23 June 1988
Resolved
REMOVE OR PROPERLY INSTALL BATTERY CHARGERS IN THE GENERATOR ROOM.
Engineering
Issued 23 June 1988
Resolved
PROVE PROPER OPERATION OF THE BILGE SUCTION VALVE FORWARD OF THE COLLISION BULKHEAD.
Electrical
Issued 23 June 1988
Resolved
PROVE PROPER OPERATION OF ALL EMERGENCY LIGHTING ON THE MAIN AND UPPER DECKS PRIOR TO PLACING THE VESSEL IN OPERATION.
Navigation
Issued 23 June 1988
Resolved
PROVIDE COPIES OF THE COAST PILOT AND CURRENT TIDE TABLES.
Lifesaving
Issued 23 June 1988
Resolved
POST EMERGENCY CHECK-OFF LIST.
Navigation
Issued 23 June 1988
Resolved
PLACE PROPER LIGHT BULBS IN ALL NAVIGATION LIGHTS.
Documentation
Issued 20 November 1987
Resolved
CORRECT SPELLING OF VESSEL'S NAME ON DOCUMENT.
Electrical
Issued 25 June 1987
Resolved
SUBMIT TO [name withheld] PLANS DETAILING NEW ELECTRICAL INSTALLATIONS AS PER CONVERSION.
Lifesaving
Issued 25 June 1987
Resolved
PRIOR TO CARRYING PASSENGERS PROVIDE TWO (2) ADDITIONAL CHILD PERSONNEL FLOTATION DEVICES.
Unknown
Issued 21 December 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL PATRICE LIRETTE DN636835.
Deck/Cargo
Issued 21 December 1984
Resolved
PROVIDE AN ADEQUATE WINCH TO RAISE AND LOWER THE VESSEL'S ANCHOR.
Unknown
Issued 21 December 1984
Resolved
PLACE BOTH MARINE SANITATION DEVICES (MSD) IN PROPER WORKING ORDER.
Lifesaving
Issued 12 October 1982
Resolved
SERVICE BOTH INFLATABLE LIFE RAFTS.
Casualty record · 2
8 June 2004Routine · role: Involved in a Marine Casualty · activity 2109346
10 October 2010Routine · role: Involved in a Marine Casualty · activity 3868266
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.