MAURY USCG vessel records Sign in
← All vessels

SUNSET HORNBLOWER

SUNSET HORNBLOWER is a 1981 passenger vessel (inspected). The Coast Guard has recorded 106 inspections since 1981, most recently in June 2025, along with 193 deficiencies — 1 with no resolution recorded —, 7 operational controls and 2 casualty investigations between 2004 and 2010.

Records from 1981 to 2025. Most recent: inspection, 23 June 2025.

Built
1981
Last inspected
23 June 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDF5955
Flag
UNITED STATES
367469070
Maury page id
psix-52985

Inspections, by type

…with no type recorded17
Years with a record 42 calendar years (1981–2025)
The 106 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)98.0 ft × 23.4 ft × 6.3 ft
Registered tonnagegross 91 / net 62
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCAMCRAFT INC · JEAN LAFITTE, LA, UNITED STATES · built 1981
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it91 - Regulatory (Subpart C or D), Gross Ton
62 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF5955MMSI 367469070 · active · compulsorily equipped · granted 26 August 2020, expires 15 October 2030 · licensed under a name not among this hull’s recorded names (not shown)
WDA2451MMSI not assigned · expired · compulsorily equipped · granted 4 October 2000, cancelled 4 December 2010
WCU3587MMSI not assigned · expired · voluntarily equipped · granted 29 August 1995, cancelled 7 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 106

23 June 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8164992
16 January 2025 Deficiency Check · Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8063025
11 June 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7932391
31 August 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7781299
16 May 2023 In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7689607
23 February 2023 Drydock Exam · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7641092
28 June 2022 Internal Structural Exam · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7472303
29 September 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7323487
1 April 2021 Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7166810
26 February 2021 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7146792
1 October 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7069069
20 August 2019 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6789097
6 August 2019 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6805001
24 January 2019 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6613963
12 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6538703
10 September 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6537295
21 June 2017 Deficiency Check · COI Inspection · Administrative Inspection · Construction Oversight
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6199160
12 May 2017 Deficiency Check · Administrative Inspection · Examination of Repairs · Drydock Exam · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6174963
23 January 2017 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6075240
24 August 2016 Internal Structural Exam · Annual Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5980316
24 September 2015 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5732913
26 June 2014 Administrative Inspection · Annual Inspection · Examination of Repairs
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4900536
23 June 2012 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4352935
15 May 2012 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4321641
23 February 2012 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4249575
22 July 2011 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4090865
10 October 2010 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3868266
14 January 2010 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3663521
11 August 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3291616
12 July 2007 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2976957
26 June 2007 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2974070
12 June 2007 Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2966042
18 May 2007 DAPI Audit · Deficiency Check
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 2955634
13 February 2007 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2871666
17 October 2006 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2802981
25 July 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2720100
31 May 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2666670
18 July 2005 Hull Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2424288
16 June 2005 Internal Structural Exam · Drydock Extension · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2376244
24 August 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2174017
21 July 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2134371
9 June 2004 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2093573
8 June 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2109346
17 October 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1929289
22 August 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1887466
5 August 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1832492
27 May 2003 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1787283
3 March 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1748672
10 February 2003 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1736977
15 January 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1731084
10 December 2002 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1718063
19 July 2002 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1648841
23 July 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384831
20 April 2001 Excursion Permit
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1469031
30 March 2001 Deadweight Survey · Inclining Experiment
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1413896
19 March 2001 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1395657
22 February 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1435176
8 August 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1420380
21 July 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1103125
14 June 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1079059
3 June 1999 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1360920
14 April 1999 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1393132
15 April 1998 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 789319
8 October 1997 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1111196
9 April 1997 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1100789
15 October 1996 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1153471
20 October 1995 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 884243
13 September 1995 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1422617
5 July 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177282
12 April 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1168949
16 March 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 857703
2 February 1994 Administrative
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 851710
7 January 1994 Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 850460
13 December 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1444773
9 December 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 849124
8 October 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 826538
24 August 1993 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 847536
8 July 1993 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1399886
15 April 1993 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410803
8 September 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 941412
3 August 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1270949
7 July 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 943607
4 December 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 942740
23 July 1991 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1249039
26 June 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 920048
18 June 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 902924
24 May 1990 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232908
29 December 1989 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 925164
29 December 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1229164
30 June 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 898213
19 June 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1202390
17 April 1989 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1032317
7 July 1988 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 897657
23 June 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 893421
9 December 1987 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1308057
20 November 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1025688
4 November 1987 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1332655
24 September 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1005603
25 June 1987 Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019764
21 December 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1309410
21 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1283984
21 December 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1285199
12 October 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 970394
6 April 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969069
12 October 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968873
17 June 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1277385

Deficiency record · 193

02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 23 June 2025 Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. The flame screens must consist of a single screen of corrosion resistant wire of at least 30 × 30 mesh. The flame screens or flame arresters must be of such size and design as to prevent reduction in the net cross sectional area of the vent pipe and permit cleaning or renewal of the flame screens or arrester elements. Replace vent rings. (46 CFR 182.450(e))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 July 2025
Resolved 9 July 2025
Resolution: Vessel provided photograph of replaced vent rings.
02 - Structural Conditions › N/A - No Subsystem › Enhanced survey programme (ESP)
Issued 23 June 2025 No resolution recorded
The construction and arrangement of a vessel must allow the safe operation of the vessel ... giving consideration to provisions for a seaworthy hull... and necessary facilities for passengers and crew. MI observed gaps and cracks in top longitudinal members in the vessel's liquor cabinet. Grind out and renew welds at next DDX. (46 CFR 177.100)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 June 2024 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartments under all practical conditions. MI observed the refrigerator condenser pipe dripping into a the bilge space below. MI requests plan proposal for tying this into an overboard discharge pipe by 25JUN2024. 46 CFR 182.25-1(a)(OLD-T)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 16 July 2024
Resolution: Condensor piping was tied into the sink drain piping to the satisfaction of the MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 11 June 2024 Resolved
Penetrations and openings in watertight bulkheads must have means to make them watertight. MI observed electrical conduit passing through a watertight boundary, underneath the dishwasher, with evidence of dishwasher fluid leaking past the conduit into the watertight space below. Repair watertight boundary to the satisfaction of the Marine Inspector. 46 CFR 171.114(a)(2)(Old-T)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 16 July 2024
Resolution: Watertight boundary was repaired to the satisfaction of the MI.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 11 June 2024 Resolved
Protective gratings shall be provided at such locations where persons or gear might come in contact with the exhaust pipe. MI observed inadequate exhaust lagging on the starboard engine exhaust. Lagging needs to be reattached in order to cover the entire piping or protective grating installed. 46 CFR 182.15-20 (g) (Old-T)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 8 July 2024
Resolution: Replaced exhaust insulation and provided pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Adequate lighting - mooring arrangements
Issued 11 June 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of electrical equipment. MI observed a light fixture inoperable and another with a missing cover in the vessel's storeroom. Repair light fixtures to the satisfaction of the Marine Inspector. 46 CFR 176.806
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 16 July 2024
Resolution: All light fixtures were fixed to the satisfaction of the MI.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 11 June 2024 Resolved
The name of the vessel must be marked or painted in clearly legible letters on each life float paddle. MI observed the paddles in the forward/starboard buoyant apparatus with faded stenciling. Restencil paddles to the satisfaction of the Marine Inspector. 46 CFR 185.604 (g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 8 July 2024
Resolution: Restenciled paddles and sent pictures to the satisfaction of the MI.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 11 June 2024 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: inspection of all accessible parts of the interior of the hull and the watertight bulkheads. MI observed small cracks in the starboard steering compartment, on the forward peak, on top of the stem. Vessel must repair the cracks prior to next credit drydock. 46 CFR 176.802 (a)(1)
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 March 2025
Resolved 23 January 2025
Resolution: No cracks found in described area during JAN 2025 dry dock inspection. Cleared outstanding 835.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 31 August 2023 Resolved
Fire hydrants, when required, shall be of sufficient number and so located that any part of the vessel may be reached with an effective stream of water from a single length of hose. Hole in fire main found in void #2. Repair fire main piping to the satisfaction of the attending marine inspector. 46 CFR 181.15-5(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 September 2023
Resolution: Fire main repaired and tested to satisfaction of attending Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 August 2023 Resolved
Penetrations and openings in watertight bulkheads must have means of making them watertight. Void #1 stbd side wire transit penetration is not watertight. Seal wire transit to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 22 September 2023
Resolution: Vessel sealed wire transit to the satisfaction of the attending marine inspector.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 August 2023 Resolved
Penetrations and openings in watertight bulkheads must have means of making them watertight. Engine room / Generator bulkhead high port side penetration is not watertight. Seal penetration to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 22 September 2023
Resolution: Vessel sealed penetration to the satisfaction of the attending marine inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 August 2023 Resolved
An inspection for renewal of a certificate of inspection in conducted to determine if the vessel is in satisfactory condition, fit for the service intended, and complies with all applicable regulations. It includes inspection and testing of the structure, machinery, equipment, and drills. The vessel must conduct a satisfactory man overboard drill, fire drill, and have their machinery, equipment, and structure inspected and tested underway.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 22 September 2023
Resolution: Completed inspection and testing of the structure, machinery, equipment, and drills. Conducted a satisfactory man overboard drill, fire drill, and tesed underway their machinery, equipment, and structure.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 August 2023 Resolved
Unless otherwise stated in this section, life jackets must be stored in convenient places distributed throughout accommodation spaces. (1) Each stowage container for life jackets must not be capable of being locked. If practicable, the container must be designed to allow the life jackets to float free. Stowage areas of lifejackets were found to have locks that would compromise the ability to be float free. Repair the stowage areas to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 September 2023
Resolved 14 September 2023
Resolution: Locks removed from storage containers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 August 2023 Resolved
The bilge pipe piercing the collision bulkhead shall be fitted with a screw-down valve located on the forward side of the collision bulkhead and operable from above the weather deck. Bilge piping piercing FWD of collision bulkhead screw down valve inoperable. Vessel completed repairs and operationally tested to the satisfaction of the marine inspector. 46 CFR 182.25-5(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 September 2023
Resolution: Vessel completed repairs and operationally tested to the satisfaction of the marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 31 August 2023 Resolved
Each inflatable liferaft, inflatable buoyant apparatus, life float, and buoyant apparatus on the vessel on March 11, 1996, may be used to meet the requirements of this part for these survival craft as long as the survival craft is continued in use on the vessel, and is in good and serviceable condition. Life floats orange color was faded from dirt and age. Vessel to clean dirt from life floats to the satisfaction of the attending marine inspector. Vessel cleaned life floats to the satisfaction of the marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 1 September 2023
Resolution: Vessel cleaned life floats to the satisfaction of the marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Openings to cargo area, doors, ... scuttles
Issued 28 June 2022 Resolved
An interior or exterior opening that is temporarily closed by cover plates or boards held in place only by hook bolts is considered open to the weather. Hook bolts were not visible and additional paneling material has been added to the interior of the tonnage door. Make corrections at next credit drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 23 February 2023
Resolution: Verified removal of paneling material.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 June 2022 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Diesel fuel supply piping is connected to the fire main piping with a closed valve and temporary lock-out tag preventing contamination. Permanent means for segregation must be made at next credit drydock.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 23 February 2023
Resolution: Verified that piping was not a diesel supply piping.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 June 2022 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments. Bilge pump in the engine compartment was not operable. 46 CFR 182.25-1(a) OLD T
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 28 June 2022
Resolution: Crew replaced wasted gasket between two connection flanges and demonstrated sat operation.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 29 September 2021 Resolved
Except as otherwise allowed by this subpart, a vessel must comply with the structural design requirements of one of the standards listed below for the hull material of the vessel. Aluminum hull vessels: Lloyd's Yachts and Small Craft; or For a vessel of not more than 30.5 meters (100 feet) in length: ABS Steel Vessel Rules (<61 Meters), with the appropriate conversions from the ABS Aluminum Vessel Rules. One inch crack found on port and starboard sides where the second transverse frame meets the first longitudinal frame.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 October 2021
Resolved 15 October 2021
Resolution: Relief holes were drilled in frame IAW NVIC 7-68 to prevent further crack propogation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 29 September 2021 Resolved
At each initial and subsequent inspection for certification the owner or managing operator shall be prepared to test the steering systems of the vessel and make them available for inspection to the extent necessary to determine that they are in suitable condition and fit for the service intended. The port rudder shaft seal was leaking at a rate of approximately one half gallong per minute while underway. The operator tightened the packing gland to the satisafction of the Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 September 2021
Resolved 29 September 2021
Resolution: The operator tightened the packing gland to the satisafction of the Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 February 2021 Resolved
A vessel exposed to salt water more than three months in any 12 month period must undergo a drydock and internal structural examination at least once every two years. Vessel has failed to schedule drydock and internal structural examination within two years of last drydock as listed on the COI.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 9 April 2021
Resolved 16 April 2021
Resolution: Conducted satisfactory dry dock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 October 2020 Resolved
All vessels of 26 feet in length and over shall be provided with individual bilge lines and bilge suctions for each watertight compartment. Valve for forepeak bilge is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2021
Resolution: Bilge valve replaced. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 August 2019 Resolved
Except as otherwise provided in this paragraph, all engine exhaust pipes must be water cooled. Vessel's port engine exhaust cooling was leaking at a rate of approximately 1 drop/5 seconds while underway. Repair the exhaust cooling leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 September 2019
Resolution: Crew replaces a stretch of piping with approved flex piping and double hose clamp fittings.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 24 January 2019 Resolved
Cracked weld on starboard side of Frame 14, where the deck meets the frame. Repair prior to dry dock completion.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 January 2019
Resolved 12 February 2019
Resolution: Weld repaired.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 12 September 2018 Resolved
IMO: Vsl is broadcasting invalid IMO #, ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 20 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 11 September 2018 Resolved
To enhance protection of life and property it is mandatory that each 406.0-406.1 MHz EPIRB be registered with NOAA before installation and that information be kept up-to-date. Call sign incorrect; update registration. 47 CFR 80.1061(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2018
Resolved 13 September 2018
Resolution: Updated call sign on EPIRB registration.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 September 2018 Resolved
Provide a minimum standard of regulations for electrical installations and equipment that will result in a vessel that is reasonably safe from electrical shock of personnel. Dead-end wire found in engine room below A/C chill water pump junction box. Connected to electrical panel, breaker taped off, however could accidentally be energized; remove wire. 46 CFR 183.01-5
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2018
Resolved 13 September 2018
Resolution: Removed wire.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 11 September 2018 Resolved
Watertight doors and watertight hatches must be marked on both sides in clearly legible letters at least 1 inch high: “WATERTIGHT DOOR—KEEP CLOSED” or “WATERTIGHT HATCH—KEEP CLOSED”. Labeling on both QAWTD illegible due to fading color; replace labeling.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 September 2018
Resolved 24 September 2018
Resolution: Properly labeled watertight doors.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 11 September 2018 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. NTM available, but charts not updated since February 2018; correct charts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 October 2018
Resolved 9 October 2018
Resolution: Vessel submitted photos of charts with applicable notice to mariners with corresponding chart corrections.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 September 2018 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Pitting found at the intersection of Frame 1 and the first longitudinal bulkhead. Rectify deficiency during next drydock inspection. 46 CFR 177.01-5
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2019
Resolved 11 February 2019
Resolution: Received UT report. Corrosion is minor.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 September 2018 Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operation in accordance with the terms of its certificate of inspection. Weld crack found on the starboard side at the intersection of Frame 14 and the connection to the deck. Rectify deficiency during next drydock inspection. 46 CFR 177.01-5
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 January 2019
Resolved 12 February 2019
Resolution: Weld was repaired
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 August 2017 Resolved
Provide proof of purchase for the approved man overboard net demonstrated to the Coast Guard on 08/01/2017.
Action required: 705 - Other - as specified
Due 1 September 2017
Resolved 29 August 2017
Resolution: Received proof of payment for new MOB net arrangement.
Engineering › Bilge Water Management System › Pump
Issued 6 July 2017 Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Vessel shall demonstrate the proper operation of the bilge system at 50 gallons per minute. 46 CFR 182.25-10(a) (Old T)
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 July 2017
Resolved 7 July 2017
Resolution: Bilge system was tested satisfactorily.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 6 July 2017 Resolved
Crew shall demonstrate adequate means to recover injured or unconcious man overboard. 46CFR185.420(a)
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 1 August 2017
Resolution: Conducted adequate MOB drill with [name withheld] net off of another vessel. Operator has not yet purchased a net for themselves. Added an additional deficiency.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 28 June 2017 Resolved
1) Replace the 12” wide vertical ladder leading from the large (4’x6’) escape hatch on the second deck into the aft starboard corner of the main deck with the originally approved installation. Remove all stored items currently preventing the quick escape of passengers to the satisfaction of the attending marine inspector. 46CFR177.15-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 June 2017
Engineering › Bilge Water Management System › Piping
Issued 12 May 2017 Resolved
Repair small leak in the bilge system directly in front of the starboard main engine.
Due 6 July 2017
Resolved 3 July 2017
Resolution: Leaking section of pipe, removed/cleaned and reinstalled. Leak was at a joint in the piping.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 May 2017 Resolved
New strainer for the generator is not in compliance with CVC Policy 16-02 and is not accepted. Provide plan for the renewal of the strainer and replace current strainer with compliant strainer.
Due 31 July 2017
Resolved 1 August 2017
Resolution: Verified the installation of the new strainer for the generator. All Sat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 12 May 2017 Resolved
All raw water systems were utilizing only single hose clamps, double clamps must be added per 46CFR182.720(e)(3)(v)(B).
Due 3 July 2017
Resolved 3 July 2017
Construction/Loadline › Hull › Side Shell
Issued 29 July 2014 Resolved
Submit repair proposal for through-hull penetrations in way of stbd exhaust hull penetration.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 August 2014
Resolution: Vessel conducted proper repairs to the satisfaction of the attending MI.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 29 July 2014 Resolved
Provide working gauges for generators.
Due 29 September 2014
Resolved 16 October 2014
Stability › Watertight Integrity › General
Issued 29 July 2014 Resolved
Properly seal/cap penetrations: under engine room. watertight door, stbd side near the overhead in between main engine room and generator room.
Due 29 August 2014
Resolved 16 October 2014
Documentation › Markings/Placards › Capacity Marking
Issued 29 July 2014 Resolved
Renew 02 deck placards to restrict total persons to 66 IAW vessel's stability letter.
Due 29 July 2014
Resolved 16 October 2014
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 29 July 2014 Resolved
Make proper temp repairs to the MSD tank at identified locations to stop leaking.
Due 29 August 2014
Resolved 16 October 2014
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 29 July 2014 Resolved
Provide repair proposal for permanent repairs to MSD tank. Permanent repairs shall be completed during next available drydock.
Action required: 705 - Other - as specified
Due 30 June 2015
Resolved 24 August 2016
Resolution: Sewage tank replaced at 0215 dry dock.
Lifesaving › Lifefloat › Serviceable
Issued 29 July 2014 Resolved
Make primary lifesaving equipment available for inspection upon removal of protected species.
Due 29 August 2014
Resolved 16 October 2014
Electrical › Electric Supply System (service) › Cable
Issued 23 June 2012 Resolved
Prpoerly terminate dead ended wires in void under galley.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 14 August 2012
Resolution: Wires have been properly terminated and or removed.
Engineering › Pressure Vessel › Relief Valve
Issued 23 June 2012 Resolved
Complete a test of the pressure relief valve on STBD pressure vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 14 August 2012
Resolution: Pressure vessel pressure relief valve sat.
Electrical › Electrical Distribution System (service) › Bus Bar Connection
Issued 23 June 2012 Resolved
Provide a suitable cover for battery box installation
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 14 August 2012
Resolution: Suitable covers were properly installed.
Electrical › Lighting (service) › Lighting Fixture
Issued 23 June 2012 Resolved
Provide a suitable cover over lights in captain and crew state rooms.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 August 2012
Resolved 14 August 2012
Resolution: Corrected, New lights were properly installed.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
MIS form not submitted by March 15 as required by 46 CFR part 16.500.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed proof of MIS submission.
Documentation › Logs/Records › Drug Test Records
Issued 15 May 2012 Resolved
No copy of contract or proof of enrollment in Consortium as required by 46 CFR 16.
Due 14 June 2012
Resolved 21 May 2012
Resolution: DER emailed copy of updated consortium contract.
Engineering › Bilge Water Management System › Piping
Issued 25 July 2011 Resolved
Found hole in bilge piping from suction side of PTO Bilge Pump. Repair in kind and proce proper operation to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2011
Resolved 1 August 2011
Resolution: The vessel''''s mechanic replace the section of faulty piping in kind and tested.
Engineering › Compressed Air System (start air) › Receiver/Bottle
Issued 25 July 2011 Resolved
Found excessive sludge in bottom of start air receiver. Make receiver ready for proper internal inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 August 2011
Resolved 1 August 2011
Resolution: Visually inspected the air reciever after a thorough cleaning was conducted.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 25 July 2011 Resolved
Provide serviced B-II fire extinguisher in engine room.
Condition: Improper/Lack of Maintenance
Due 1 August 2011
Resolved 1 August 2011
Resolution: Inspected new B-II fir extinguisher.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 14 January 2010 Resolved
Repair fasteners on two noted lifejackets on the upper deck.
Action required: 705 - Other - as specified
Resolved 19 January 2010
Communications › Radio Communications › EPIRB
Issued 14 January 2010 Resolved
Provide onboard Catagory I EPIRB.
Action required: 705 - Other - as specified
Resolved 19 January 2010
Engineering › Diesel Engine (propulsion-direct drive) › Blower, Centrifugal
Issued 14 January 2010 Resolved
Prove proper operation of engine room blowers.
Due 14 April 2010
Resolved 23 April 2010
Resolution: The original blowers were not repairable, and the company who made them had gone out of business. The new blowers were made specifically to replace the old ones and were installed by Bay Ship & Yacht. Inspected operationally; all sat.
Electrical › Lighting (service) › Lighting Fixture
Issued 11 August 2008 Resolved
Emergency light fixture was missing light bulb. This is the light that shows the path to the emergency escape hatch. Fixed on the spot.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 August 2008
Resolved 11 August 2008
Fire Fighting › Means of Escape › Escape Route Signs
Issued 11 August 2008 Resolved
Emergency escape hatch was not marked as such and is located behind the switch board making it hard to find. Fixed on the spot.
Condition: Unknown
Action required: 705 - Other - as specified
Due 11 August 2008
Resolved 11 August 2008
Lifesaving › Lifebuoys › Stowage
Issued 11 August 2008 Resolved
The throwable life ring did not have a corrosion resistant clip connecting it to the light. It was tied on. Corrected on the spot.
Due 11 August 2008
Resolved 11 August 2008
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 12 July 2007 Resolved
Correct vessel owner on certificate of documentation.
Action required: 705 - Other - as specified
Due 12 August 2007
Resolved 24 August 2007
Stability › Watertight Integrity › General
Issued 12 July 2007 Resolved
Seal hole in lazarette/engine room bulkhead to make watertight.
Action required: 705 - Other - as specified
Due 12 August 2007
Resolved 24 August 2007
Electrical › Lighting (service) › Lighting Fixture
Issued 12 July 2007 Resolved
Make repairs to fluorescent lighting fixture in captain's cabin.
Action required: 705 - Other - as specified
Due 12 August 2007
Resolved 24 August 2007
Documentation › Logs/Records › Drug Test Records
Issued 18 May 2007 Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently enrolls new employees in its contracted drug testing consortium on a quarterly basis, rather than at the time of hiring.
Due 5 July 2007
Resolved 12 June 2007
Resolution: New employee''s names will be added to the company''s consortium''s random drug testing list prior the employee acting in a safety sensitive position.
Documentation › Logs/Records › Drug Test Records
Issued 18 May 2007 Resolved
Random drug testing was found to not be conducted in accordance with 46 CFR 16.230. Company currently is waiving random drug testing for some employees, based upon their participation in another unaffiliated company.
Due 5 July 2007
Resolved 12 June 2007
Resolution: Random drug tests will no longer be waived.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 13 February 2007 Resolved
Prove proper operation of lazarette bilge high level alarm.
Due 13 February 2007
Resolved 13 February 2007
Engineering › Fuel Oil Service System › Piping
Issued 13 February 2007 Resolved
Repair fuel leak on port #2 generator fuel line.
Action required: 705 - Other - as specified
Due 13 February 2007
Resolved 13 February 2007
Lifesaving › Lifefloat › Float-free Link
Issued 13 February 2007 Resolved
Properly connect life floats to weak link.
Action required: 705 - Other - as specified
Due 13 February 2007
Resolved 13 February 2007
Fire Fighting › Means of Escape › Escape Route Signs
Issued 25 July 2006 Resolved
Install emergency escape exit signs for engine room and lazarette In Accordance with 46 CFR 122.606
Due 25 August 2006
Resolved 17 October 2006
Lifesaving › Lifefloat › Serviceable
Issued 25 July 2006 Resolved
Make repairs/replace all lifefloats.
Due 25 August 2006
Resolved 17 October 2006
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 July 2006 Resolved
Dead end all identified wires outboard port generator next to battery banks.
Due 25 August 2006
Resolved 17 October 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 July 2006 Resolved
Renew expired eye wash In Accordance with 46 CFR 160.041
Due 25 August 2006
Resolved 25 July 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 25 July 2006 Resolved
Post lifejacket donning on second deck near lifejacket stowage area.
Due 25 July 2006
Resolved 25 July 2006
Fire Fighting › Fire Main › Pressure
Issued 25 July 2006 Resolved
Prove proper operation for installed firemain system IAW 46 CFR 118.300
Due 28 July 2006
Resolved 25 July 2006
Construction/Loadline › Hull › Weld
Issued 21 July 2004 Resolved
Make repairs to cracked welds at base of spray shield starboard side of the focsle.
Action required: 705 - Other - as specified
Due 28 February 2005
Resolved 12 July 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 21 July 2004 Resolved
Remove items that are a possible fire hazard from the top of the galley range vents.
Action required: 705 - Other - as specified
Due 21 July 2004
Resolved 21 July 2004
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 21 July 2004 Resolved
Replace light in refer space.
Action required: 705 - Other - as specified
Due 21 July 2004
Resolved 21 July 2004
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 21 July 2004 Resolved
Repair exhaust leak on port side generator prior to using generator.
Action required: 705 - Other - as specified
Due 5 August 2004
Resolved 24 August 2004
Electrical › Electric Supply System (service) › Cable
Issued 21 July 2004 Resolved
Remove wire nuts or place in a junction box, wire connections on aft bulkhead below galley deck.
Action required: 705 - Other - as specified
Due 5 August 2004
Resolved 24 August 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 21 July 2004 Resolved
Replace glass globes in lighting fixtures in engine room and lazarette.
Action required: 705 - Other - as specified
Due 5 August 2004
Resolved 24 August 2004
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 July 2004 Resolved
Provide metallic wire supports for wiring on overhead in engine room.
Action required: 705 - Other - as specified
Due 5 August 2004
Resolved 24 August 2004
Engineering › Compressed Air System (control)
Issued 22 August 2003 Resolved
Provide safety guard for rotating machinery on starboard air compressor.
Action required: 705 - Other - as specified
Due 1 September 2003
Resolved 17 October 2003
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 5 August 2003 Resolved
Prove operation of all installed smoke detectors on main deck.
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 22 August 2003
Lifesaving › Buoyant Apparatus
Issued 5 August 2003 Resolved
Replace 1 missing paddle.
Due 5 August 2003
Resolved 5 August 2003
Lifesaving › Buoyant Apparatus
Issued 5 August 2003 Resolved
Replace retro on life floats.
Due 5 August 2003
Resolved 5 August 2003
Lifesaving › Buoyant Apparatus
Issued 5 August 2003 Resolved
Replace pendant on life float.
Due 5 August 2003
Resolved 5 August 2003
Fire Fighting › Fire Pumps
Issued 5 August 2003 Resolved
Provide hand fire pump.
Action required: 705 - Other - as specified
Due 5 August 2003
Resolved 5 August 2003
Engineering › Bilge Water Management System
Issued 5 August 2003 Resolved
Replace check valve in bilge line leading to compartment forward of collision bulkhead.
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 22 August 2003
Engineering › Bilge Water Management System
Issued 5 August 2003 Resolved
Add strainer to bilge suction in compartment forward of engine room.
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 22 August 2003
Engineering › Bilge Water Management System
Issued 5 August 2003 Resolved
Label bilge handle for fore peak bilge valve.
Due 5 August 2003
Resolved 5 August 2003
Engineering › Compressed Air System (control)
Issued 5 August 2003 Resolved
Demonstrate proper operation of pressure relief valve. LEGACY COMPONENT DESC: Compressor
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 22 August 2003
Electrical › Electric Supply System (service)
Issued 5 August 2003 Resolved
Provide plans to replace all welding cable in DC electrical system with marine grade battery cable. LEGACY COMPONENT DESC: Battery Conductor
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 13 August 2003
Resolution: Approved plans.
Electrical › Electrical Distribution System (service)
Issued 5 August 2003 Resolved
Remove dead wire on outboard side of stbd generator.
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 22 August 2003
Construction/Loadline › Penetrations › Valve Flange
Issued 27 May 2003 Resolved
Renew starboard side aft condensor thru hull fitting spool piece.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 13 June 2003
Construction/Loadline › Hull
Issued 27 May 2003 Resolved
Crop and renew shell plate in way of stbd side aft condensor overboard as indicated by the attending marine inspector. LEGACY COMPONENT DESC: Hull Plating
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 13 June 2003
Construction/Loadline › Hull › Hull Plating
Issued 27 May 2003 Resolved
Renove fairing compound in way of port side fwd and make area available for inspection.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 12 June 2003
Engineering
Issued 27 May 2003 Resolved
Clean and prep starboard shaft keyway for inspection.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 5 August 2003
Stability › Watertight Integrity
Issued 27 May 2003 Resolved
Install captive chain on forward peak scuttle.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 5 August 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 27 May 2003 Resolved
repair as new exhaust system, ports side aft in way of FRP repairs.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 5 August 2003
Construction/Loadline › Penetrations › Valve Flange
Issued 27 May 2003 Resolved
Make all sea valves available for inspection.
Action required: 705 - Other - as specified
Due 10 July 2003
Resolved 12 June 2003
Electrical
Issued 27 May 2003 Resolved
Repair as new motor in way of stbd side aft air compressor.
Action required: 705 - Other - as specified
Due 5 September 2003
Resolved 22 August 2003
Engineering › Compressed Air System (start air)
Issued 10 February 2003 Resolved
Make port air receiver located in generator/steering gear compartment available for inspection IAW 46 CFR 61.10. Pressure vessel is greater than 5 cubic feet in size and must be either internally examined or hydrostatically tested to the satisfaction of attending marine inspector. LEGACY COMPONENT DESC: Compressor
Action required: 705 - Other - as specified
Due 30 June 2003
Resolved 3 March 2003
Resolution: Satifactorily tested.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 10 February 2003 Resolved
Properly lock MSD to prevent accidental discharge.
Due 10 February 2003
Resolved 10 February 2003
Resolution: Fixed.
Operations/Management › Pollution › Retention of Oily Mixture
Issued 10 February 2003 Resolved
Clean up the small amount of oil located in engine room bilge.
Due 10 February 2003
Resolved 10 February 2003
Resolution: Cleaned up.
Engineering › Fuel Oil Service System
Issued 10 December 2002 Resolved
Submit proposal to install new fuel oil fill lines to service the starboard fuel oil tank from the port side of the vessel.
Action required: 705 - Other - as specified
Due 9 January 2003
Resolved 5 August 2003
Resolution: Resolved by fueling policy on fax dated 02/10/2003, "Sunset Hornblower Fueling Policy".
Engineering › Fuel Oil Service System
Issued 10 December 2002 Resolved
Discontinue the use of the vessel's upper fuel oil tanks as service tanks. The tanks may be used as storage tanks only.
Action required: 705 - Other - as specified
Due 9 January 2003
Resolved 15 January 2003
Electrical
Issued 19 July 2002 Resolved
Remove electrical tape connections in battery charger wires in lazarette. LEGACY COMPONENT DESC: Wiring
Due 19 July 2002
Resolved 19 July 2002
Navigation › Piloting/Steering › US Coast Pilot
Issued 19 July 2002 Resolved
Update Coast Pilot. (2000 version onboard)
Due 19 July 2002
Resolved 19 July 2002
Stability › Watertight Integrity
Issued 19 July 2002 Resolved
Remove old MSD supply line (pvc) and repair the hole in the bulkhead. PVC pipe ran through hole in watertight bulkhead with no fitting.
Due 19 July 2002
Resolved 19 July 2002
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 July 2002 Resolved
Renew expired aspirin in first aid kit.
Due 19 July 2002
Resolved 19 July 2002
Documentation › Logs/Records
Issued 19 July 2002 Resolved
Log periodic EPIRB tests.
Due 19 July 2002
Resolved 19 July 2002
Construction/Loadline
Issued 3 June 1999 Resolved
INSTALL HOLDING CHAIN ON HATCH COVER FOR FORE PEAK.
Condition: Unknown
Due 11 June 1999
Resolved 28 June 1999
Lifesaving
Issued 3 June 1999 Resolved
RENEW HYDROSTATIC RELEASE FOR EPIRB.
Condition: Unknown
Due 3 June 1999
Resolved 3 June 1999
Construction/Loadline
Issued 3 June 1999 Resolved
PROVE PROPER OPERATION OF AUDIBLE ALARM FOR BILGE HIGH WATER INDICATOR ON BRIDGE.
Condition: Unknown
Due 11 June 1999
Resolved 28 June 1999
Lifesaving
Issued 3 June 1999 Resolved
INSTALL SAFETY CHAINS ON BRIDGE WINGS.
Condition: Unknown
Due 11 June 1999
Resolved 28 June 1999
Lifesaving
Issued 3 June 1999 Resolved
INSTALL RETROREFLECTIVE TAPE ON RING BUOYS.
Condition: Unknown
Due 11 June 1999
Resolved 28 June 1999
Lifesaving
Issued 3 June 1999 Resolved
PROVIDE AND DISPLAY PFD DONNING PLACARDS.
Condition: Unknown
Due 11 June 1999
Resolved 28 June 1999
Navigation
Issued 3 June 1999 Resolved
PROVIDE AND POST EMERGENCY RADIO PLACARD.
Condition: Unknown
Due 11 June 1999
Resolved 28 June 1999
Engineering
Issued 3 June 1999 Resolved
INSTALL FLAME IMPINGEMENT BOWL ON AFT RACOR FILTER FOR STARBOARD MAIN ENGINE.
Condition: Unknown
Due 11 June 1999
Resolved 28 June 1999
Electrical
Issued 9 April 1997 Resolved
INSTALL RESPECTIVE ELECTRICAL PARTS SUCH AS WIRE NUTS, BOX COVERS AND BRACKETS TO THE ENGINEROOM ELECTRICAL COMPONENTS.
Condition: Unknown
Due 9 April 1997
Resolved 10 April 1997
Construction/Loadline
Issued 9 April 1997 Resolved
REMOVE THE FIXED STRAINER VICINITY OF THE FORWARD STBD SIDE FOR CLOSER EXAMINATION OF THE SEA CHEST INTERNALS.
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Construction/Loadline
Issued 9 April 1997 Resolved
MAKE OPERABLE THE ESCAPE SCUTTLE DOGGING MECHANISM FOR EXITING THE ENGINE ROOM.
Condition: Unknown
Due 9 April 1997
Resolved 10 April 1997
Construction/Loadline
Issued 9 April 1997 Resolved
MAKE OPERABLE THE ESCAPE SCUTTLE DOGGING MECHANISM FOR EXITING THE STEERINGGEAR COMPT.
Condition: Unknown
Due 9 April 1997
Resolved 10 April 1997
Electrical
Issued 9 April 1997 Resolved
RE-ATTACH ELECTRICAL BOX/CONDUIT TO THE REEFER COMPRESSOR LOCATED ON THE PORT SIDE BELOW THE GALLEY.
Condition: Unknown
Due 9 April 1997
Resolved 10 April 1997
Construction/Loadline
Issued 9 April 1997 Resolved
RESTORE THE FWD STEERING GEAR COMPT BULKHEAD TO WATERTIGHT INTEGRITY BY PERMANENTLY PLUGGING HOLES THAT HAD BEEN DRILLED AND SEALING AROUND ESTABLISHED WIRE RUN PENETRATIONS.
Condition: Unknown
Due 9 April 1997
Resolved 10 April 1997
Construction/Loadline
Issued 9 April 1997 Resolved
MAKE PERMANENT REPAIRS TO THE CRACKED WELD OF THE FAIRING TO THE PORT SHAFT
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Construction/Loadline
Issued 9 April 1997 Resolved
REMOVE POROSITY FROM EXISTING WELD AND APPLY NEW WELD TO THE PORT STRUT INBOARD LEG.
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Construction/Loadline
Issued 9 April 1997 Resolved
REMOVE FIXED STRAINER VICINITY OF THE PORT AFT INBOARD BOTTOM FOR CLOSER EXAMINATION OF THE SEA CHEST INTERIOR.
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Documentation
Issued 15 October 1996 Resolved
PROVIDE PROOF OF ENROLLMENT OF CREW IN A RANDOM DRUG TESTING PROGRAM.
Condition: Unknown
Due 31 October 1996
Resolved 9 December 1996
Lifesaving
Issued 20 October 1995 Resolved
RELOCATE WATERLIGHTS FROM MAST TO READILY ACCESSIBLE POSITION.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Construction/Loadline
Issued 20 October 1995 Resolved
PROVIDE ADEQUATE CLOSURES AND SAFETY CHAINS FOR MAIN DECK DOORS AFT.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Construction/Loadline
Issued 20 October 1995 Resolved
POST WARNING LABEL MAIN DECK DOOR AFT, DO NOT OPEN WHEN PASSENGERS ARE ON BOARD.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Engineering
Issued 20 October 1995 Resolved
LABEL FUEL AND WATER FILL PIPES AND VENTS.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Documentation
Issued 20 October 1995 Resolved
PROVIDE VALID FCC RADIO TELEPHONE SAFETY CERTIFICATE.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Documentation
Issued 20 October 1995 Resolved
PRODUCE VALID FCC RAQDIO TELEPHONE OPERATORS LICENSE.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Lifesaving
Issued 20 October 1995 Resolved
PROVIDE PROPER WEAK LINKS FOR LIFE FLOATS.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Lifesaving
Issued 20 October 1995 Resolved
DEMONSTRATE THE ABILITY TO LIFT A PERSON FROM THE WATER TO THE RAIL DURING DRILLS.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Lifesaving
Issued 20 October 1995 Resolved
LABEL LIFE JACKET STORAGE LOCKERS.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Lifesaving
Issued 20 October 1995 Resolved
PERMENANTLY MOUNT BRACKETS FOR LIFE FLOAT WATERLIGHTS.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Navigation
Issued 5 July 1994 Resolved
REMOVE INOPERABLE RADAR FM PILOT HOUSE.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Unknown
Issued 5 July 1994 Resolved
PROVIDE EVIDENCE OF ENROLLMENT IN CHEMICAL TESTING PROGRAM IAW 46 CFR SUBCHAPTER A.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Electrical
Issued 5 July 1994 Resolved
REMOVE DEAD END WIRES IN PILOT HOUSE, [name withheld], OFFICE, ENGINE ROOM AND STORAGE ROOM.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Navigation
Issued 5 July 1994 Resolved
REPLACE RUDDER ANGLE INDICATOR IN ENGINE ROOM.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Electrical
Issued 5 July 1994 Resolved
PROVIDE ADDITIONAL EMERGENCY LIGHT IN ENG ROOM.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Lifesaving
Issued 5 July 1994 Resolved
PROVIDE I ADDITONAL ADULT SIZE LIFE JACKETS. VSL PROHIBITED FROM OPERATINGWITH MORE THAN 161 PERSONS UNTIL REQUIREMENT CLEARED.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Lifesaving
Issued 5 July 1994 Resolved
MARK EMERGENCY EXIT IN CAPTAIN'S CABIN.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Construction/Loadline
Issued 5 July 1994 Resolved
REPAIR REACH ROD IN FORE PEAK.
Condition: Unknown
Due 5 July 1994
Resolved 5 July 1994
Lifesaving
Issued 13 December 1993 Resolved
PROVIDE ON BOARD COAST GUARD APPROVED LIFE FLOATS OR BOUYANT APPARATUS._x001C_ VESSEL IS RESTRICTED TO SERVICE NOT MORE THAN ONE MILE FROM LAND.
Condition: Unknown
Due 13 December 1993
Resolved 13 December 1993
Lifesaving
Issued 9 December 1993 Resolved
PROVIDE RESCUE BOAT WHEN PASSENGERS ARE ABOARD AND VESSEL IS ENGAGED IN DOCKSIDE RESTAURANT OPERATIONS.
Condition: Unknown
Due 9 December 1993
Resolved 9 December 1993
Lifesaving
Issued 8 July 1993 Resolved
Repair or replace both life floats.
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Accommodation/Occupational Safety
Issued 8 July 1993 Resolved
Replace existing dryer vent (plastic) with metal type vent.
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Engineering
Issued 8 July 1993 Resolved
Remove and replace existing plastic tubing on fuel oil service to port generator prime mover with hard piping.
Condition: Unknown
Due 8 July 1993
Resolved 8 July 1993
Electrical
Issued 7 July 1992 Resolved
REMOVE LOOSE DEAD-END CIRCUIT IN GENERATOR/STEERING SPACE BELOW WATERTIGHT DOOR.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Navigation
Issued 7 July 1992 Resolved
MAKE PROPER REPAIRS TO STBD HYDRAULIC STEERING RAM TO STOP LEAKAGE OF HYDRAULIC FLUID.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Navigation
Issued 7 July 1992 Resolved
PROVIDE VSL WITH USCG APPROVED, OR UL TO CURRENT STANDARDS, NAVIGATION LIGHTS.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Lifesaving
Issued 7 July 1992 Resolved
REMOVE OIL FROM BILGE AND DISPOSE AT PROPER SHORE SIDE FACILITY.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Electrical
Issued 7 July 1992 Resolved
PROVIDE GLOBE AND PLASTIC COVER FOR LIGHTING FIXTURES IN ENGINE ROOM.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Accommodation/Occupational Safety
Issued 7 July 1992 Resolved
CLEAN STOVE HOOD SCREENS IN GALLEY AND REPLACE (1) MISSING SCREEN.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Lifesaving
Issued 7 July 1992 Resolved
POST EMERGENCY CHECK-OFF LIST AND PFD DONNING INSTRUCTIONS.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Electrical
Issued 7 July 1992 Resolved
PROVIDE COVER FOR ELECTRICAL CONNECTION/JUNCTION BOX ON STBD HULL IN ENGINEROOM.
Condition: Unknown
Due 11 September 1992
Resolved 11 September 1992
Navigation
Issued 7 July 1992 Resolved
MAKE PROPER REPAIRS TO PORT STEERING RUDDER STUFFING TO STEM FLOW OF WATER DRIPPING INTO COMPARTMENT.
Condition: Unknown
Due 20 August 1992
Resolved 20 August 1992
Engineering
Issued 23 July 1991 Resolved
PROVIDE FUEL FILTER FLAME REFLECTOR AND VACUUM GAUGE ON STBD GENERATOR.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Construction/Loadline
Issued 23 July 1991 Resolved
REMOVE OIL WASTE FROM BILGE.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Engineering
Issued 23 July 1991 Resolved
PROVIDE 30 X 30 MESH SCREENS ON ALL FUEL VENTS.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Construction/Loadline
Issued 23 July 1991 Resolved
REPAIR FOREPEAK BILGE VALVE AND PROVE PROPER OPERATION.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Lifesaving
Issued 23 July 1991 Resolved
PROVIDE THE FOLLOWING FOR THE LIFE FLOATS:1-OAR, REPLACE TEHTER LINE, PROPERLY FASTEN WEAK LINK TO VESSEL, PROPERLY FAKE PAINTER.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Fire Fighting
Issued 23 July 1991 Resolved
PROVIDE TWO TYPE:B SIZE:II FIRE EXTINGUISHERS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Navigation
Issued 23 July 1991 Resolved
PROVIDE UP TO DATE CHARTS & T-BOAT REGULATIONS. _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Fire Fighting
Issued 23 July 1991 Resolved
LABEL FIRE STATIONS #2 AND #3.
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Fire Fighting
Issued 23 July 1991 Resolved
PROVIDE FIRE EXTINGUISHER BRACKET FOR EXTINGUISHER LOCATED IN ENGINE ROOM._x001C__x001C_ _x001C_
Condition: Unknown
Due 15 August 1991
Resolved 15 August 1991
Navigation
Issued 18 June 1990 Resolved
PROVIDE A NEW BATTERY FOR EPIRB.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Lifesaving
Issued 18 June 1990 Resolved
PROVIDE 6 HAND RED FLARE DISTRESS SIGNALS.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Navigation
Issued 18 June 1990 Resolved
PROVIDE UPDATED COAST PILOT ACCORDANCE WITH 46 CFR 185.20-35.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Engineering
Issued 18 June 1990 Resolved
VESSEL'S TWO AIR RECEIVERS MUST BE VISUALLY INSPECTED OR HYDROTESTED.
Condition: Unknown
Due 18 June 1990
Resolved 18 June 1990
Construction/Loadline
Issued 30 June 1989 Resolved
PROVIDE PORT & STARBOARD BOW MARKINGS WHICH DISPLAY VESSEL NAME CLEARLY ANDCONTRASTING TO THE HULL IN MINIMUM 4" LETTERS.
Condition: Unknown
Due 30 June 1989
Resolved 30 June 1989
Electrical
Issued 19 June 1989 Resolved
REMOVE ALL HOUSEHOLD SCREWED WIRE FITTINGS ON UPPER DECK INSIDE BAR AREA, REPLACE WITH CRIMPED/SOLDERED TYPE.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Lifesaving
Issued 19 June 1989 Resolved
REPLACE ALL DETERIORATED TAG LINES AND WATERLIGHT LINES ON LIFEFLOATS.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Lifesaving
Issued 19 June 1989 Resolved
PROVIDE 8 ADULT LIFE PRESERVERS USCG APPROVED. UNTIL THIS REQUIREMENT IS SATISFIED TOTAL NUMBER OF PERSONS ALLOWED IS REDUCED TO 154.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Electrical
Issued 19 June 1989 Resolved
REPAIR AS NEEDED AND PROVE OPERATION OF EMERGENCY LIGHTING ON UPPER DECK.
Condition: Unknown
Due 19 June 1989
Resolved 19 June 1989
Engineering
Issued 23 June 1988 Resolved
INSTALL FLAME SHIELDS ON ALL FUEL OIL FILTERS FOR MAIN ENGINES AND GENERATORS.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Electrical
Issued 23 June 1988 Resolved
REMOVE OR PROPERLY INSTALL BATTERY CHARGERS IN THE GENERATOR ROOM.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Engineering
Issued 23 June 1988 Resolved
PROVE PROPER OPERATION OF THE BILGE SUCTION VALVE FORWARD OF THE COLLISION BULKHEAD.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Electrical
Issued 23 June 1988 Resolved
PROVE PROPER OPERATION OF ALL EMERGENCY LIGHTING ON THE MAIN AND UPPER DECKS PRIOR TO PLACING THE VESSEL IN OPERATION.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Navigation
Issued 23 June 1988 Resolved
PROVIDE COPIES OF THE COAST PILOT AND CURRENT TIDE TABLES.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Lifesaving
Issued 23 June 1988 Resolved
POST EMERGENCY CHECK-OFF LIST.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Navigation
Issued 23 June 1988 Resolved
PLACE PROPER LIGHT BULBS IN ALL NAVIGATION LIGHTS.
Condition: Unknown
Due 23 June 1988
Resolved 23 June 1988
Documentation
Issued 20 November 1987 Resolved
CORRECT SPELLING OF VESSEL'S NAME ON DOCUMENT.
Condition: Unknown
Due 20 November 1987
Resolved 20 November 1987
Electrical
Issued 25 June 1987 Resolved
SUBMIT TO [name withheld] PLANS DETAILING NEW ELECTRICAL INSTALLATIONS AS PER CONVERSION.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Lifesaving
Issued 25 June 1987 Resolved
PRIOR TO CARRYING PASSENGERS PROVIDE TWO (2) ADDITIONAL CHILD PERSONNEL FLOTATION DEVICES.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Unknown
Issued 21 December 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL PATRICE LIRETTE DN636835.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Deck/Cargo
Issued 21 December 1984 Resolved
PROVIDE AN ADEQUATE WINCH TO RAISE AND LOWER THE VESSEL'S ANCHOR.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Unknown
Issued 21 December 1984 Resolved
PLACE BOTH MARINE SANITATION DEVICES (MSD) IN PROPER WORKING ORDER.
Condition: Unknown
Due 21 December 1984
Resolved 21 December 1984
Lifesaving
Issued 12 October 1982 Resolved
SERVICE BOTH INFLATABLE LIFE RAFTS.
Condition: Unknown
Due 12 October 1982
Resolved 12 October 1982

Casualty record · 2

8 June 2004Routine · role: Involved in a Marine Casualty · activity 2109346
10 October 2010Routine · role: Involved in a Marine Casualty · activity 3868266
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.