MAURY USCG vessel records
← All vessels

LEXINGTON

Built
2000
Last inspected
18 March 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 March 2026
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK5191
Flag
UNITED STATES
Maury page id
psix-5300

Documentation record

Registered dimensions (L × B × D)87.8 ft × 23.9 ft × 7.8 ft
Registered tonnagegross 86 / net 59
ITC dimensions (L × B × D)87.8 ft × 23.9 ft × 7.8 ft
ITC tonnagegross 165 / net 60
BuilderSCARANO BOATBUILDING INC · ALBANY, NY, UNITED STATES · built 2000
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Endorsements, as the file codes themcw_un
DocumentationValid · issued 24 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
165 - Convention (Subpart B), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
60 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 23 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

18 March 2026 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8327003
9 July 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8173002
31 January 2025 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8072698
11 June 2024 Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7913365
9 August 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7764308
10 January 2023 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7616350
10 August 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7600538
17 June 2021 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7227829
9 March 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7152599
14 August 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7032683
31 May 2019 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6705384
13 May 2019 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6682853
19 November 2018 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6583194
29 October 2018 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6570026
7 August 2018 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6502814
18 July 2017 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6212527
26 October 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038929
25 July 2016 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5952871
8 May 2016 Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 5937059

Deficiency record · 23

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2026 Resolved
Fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Aft Gen Fuel valve need adjusted it did not fully close during testing. Repair w/in 1 week 46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Due 25 March 2026
Resolved 26 March 2026
Resolution: Received video of the fuel shutoff valves closing remotely.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2026 Resolved
Fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. FWD gen emergency fuel shut off valve leaking. Repair w/ in 1 week. 46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Due 25 March 2026
Resolved 26 March 2026
Resolution: Received video of the fuel shutoff valves closing remotely.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 March 2026 Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of §§ 181.400 and 181.500 must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4). Vessel has recalled Heat Detector installed in the FWD Gen space. Additionally provide documentation describing what purpose or function this detector serves as there is no detection panel. 46 CFR 181.120
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2026
Resolved 27 March 2026
Resolution: Received photo of newly installed heat detector(System Sensor Model No. 5603)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2025 Resolved
In systems and applications where flexible hoses are permitted to be clamped:(1) Double hose clamping is required where practicable. The engine room generator muffler hose was missing a hose clamp. 46 CFR 146.182.410(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 15 January 2026
Resolution: received email with proof of rectification see photo in doc. tab under deficiencies
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2025 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The life jackets near the operating stations for adults and/or children were not marked. 46 CFR 185.604(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 15 January 2026
Resolution: received email with proof of rectification see photo in doc. tab under deficiencies
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 January 2025 Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not undergone a drydock examination within the last two years. Complete drydock examination.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2025
Resolution: attended vessel for dry dock inspection
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 June 2024 Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant [name withheld] side chock is damaged and is beginning to damage surrounding fiberglass. Mooring line going through chock could become damaged from chaffing. Vessel shall repair chock on STBD side. 46 CFR 184.300
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 30 July 2024
Resolution: Vessel has reapaired STBD chock. This deficency has been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2024 Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessels FWD ring life buoy is displaying signs of failure. Vessel shall replace FWD ring life buoy. 46 CFR 176.808 (b)
Action required: 705 - Other - as specified
Due 18 June 2024
Resolved 1 July 2024
Resolution: FWD life buoy has been replaced. This deficency has been resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 August 2023 Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessel is required two fixed power pumps, and at the time of inspection only had 1 working bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2021 Resolved
A vessel of 12 meters or more shall be provided with a whistle. Whistle is inoperable. Rectify w/in 4 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2021
Resolved 19 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 June 2021 Resolved
Extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. Fire extinguisher for main deck not readily accessible or clearly visible within space. Rectify w/in 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2021
Resolved 28 June 2021
Resolution: Operator provide satisfactory pictures rectifying deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2021 Resolved
Each child lifejacket must be separated from adult lifejackets. Adult and child lifejackets stowed in same space without divider. Rectify w/in 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2021
Resolved 28 June 2021
Resolution: Operator provide satisfactory pictures rectifying deficiency
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2021 Resolved
Pressure vessels that have a net internal volume of less than 5 cubic feet and do not contain hazardous materials must be stamped with either the ASME "U" or "UM" symbol. Provide proof compressor meets above standard. Rectify w/in 90 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2021
Resolved 14 September 2021
Resolution: Operator provided proof of installation of approved compressor and pressure vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 May 2019 Resolved
The vessel's machinery space is not fitted with emergency lights. Install emergency lights in accordance with 46CFR183.432
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 14 June 2019
Resolution: Emergency lights illume as designed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 May 2019 Resolved
The vessel is fitted with a pre-engineered fire extinguishing system in the machinery space. The activation of the system did not shut down the aft generator, all combustion engines within the space are required to shut down. The vessel is restricted from using the aft generator until fixed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 14 June 2019
Resolution: fire system test shut down aft generator.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 November 2018 Resolved
Vessel shall have B-15 Class fire boundaries surrounding galley's. Additionally, an integrated smoke or fire detector shall be installed in the galley area and an additional 40B:C fire extinguisher shall be maintained in the galley. 46CFR177.410(c)(1) 46CFR1821.500(b)/46CFR181.405(b); G-MSE PFM 1-99
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2018
Resolved 19 November 2018
Resolution: During an Admin inspection, the attending MI's confirmed removal of the griddle system.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 July 2017 Resolved
Provide 2017 Coast Pilot and Light List publications.
Due 18 August 2017
Resolved 7 August 2017
Resolution: Received photo documentation of new 2017 Coast Pilot and Light List publications.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 July 2017 Resolved
Provide eye wash/dressing and aspirin as per 46 CFR 160.041-4.
Due 18 August 2017
Resolved 7 August 2017
Resolution: Received photo documentation of new eye wash, gauze dressing, and aspirin for first aid kit.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 18 July 2017 Resolved
Prove pre-employment drug testing for all employees.
Due 18 August 2017
Resolved 7 August 2017
Resolution: Received proof of pre-employment drug testing for all employees.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 July 2017 Resolved
Make all high-water alarm wires enclosed in junction boxes.
Due 18 August 2017
Resolved 7 August 2017
Resolution: Received photo documentation of required junction box assemblies for high water alarm wires.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 July 2017 Resolved
Blank off open fuse in distribution panel.
Due 18 August 2017
Resolved 7 August 2017
Resolution: Received photo documentation of correct blanked off fuse in distribution panel.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 25 July 2016 Resolved
Provide sewage valve locking mechanism in accordinace with 33CFR 159.7.
Due 12 August 2016
Resolved 4 August 2016
Resolution: Owner provided a valve locking mechanism on sewage system. See attached "Lexington Def Pictures" document.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 July 2016 Resolved
Provide light bulb guards in forward space and on 2nd deck space.
Due 12 August 2016
Resolved 4 August 2016
Resolution: Light bulb guards were provided in the two spaces mentioned above. The owner provided pictures. See attached "Lexington Def Pictures" document.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.