Inspection history · 19
18 March 2026
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8327003
9 July 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8173002
31 January 2025
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8072698
11 June 2024
Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7913365
9 August 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7764308
10 January 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7616350
10 August 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7600538
17 June 2021
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7227829
9 March 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7152599
14 August 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7032683
31 May 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6705384
13 May 2019
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6682853
19 November 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6583194
29 October 2018
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6570026
7 August 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6502814
18 July 2017
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6212527
26 October 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038929
25 July 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5952871
8 May 2016
Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 5937059
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2026
Resolved
Fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Aft Gen Fuel valve need adjusted it did not fully close during testing. Repair w/in 1 week
46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Due 25 March 2026
Resolved 26 March 2026
Resolution: Received video of the fuel shutoff valves closing remotely.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2026
Resolved
Fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. FWD gen emergency fuel shut off valve leaking. Repair w/ in 1 week.
46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Due 25 March 2026
Resolved 26 March 2026
Resolution: Received video of the fuel shutoff valves closing remotely.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 March 2026
Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of §§ 181.400 and 181.500 must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4). Vessel has recalled Heat Detector installed in the FWD Gen space. Additionally provide documentation describing what purpose or function this detector serves as there is no
detection panel.
46 CFR 181.120
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 April 2026
Resolved 27 March 2026
Resolution: Received photo of newly installed heat detector(System Sensor Model No. 5603)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2025
Resolved
In systems and applications where flexible hoses are permitted to be clamped:(1) Double hose clamping is required where practicable. The engine room generator muffler hose was missing a hose clamp.
46 CFR 146.182.410(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 15 January 2026
Resolution: received email with proof of rectification see photo in doc. tab under deficiencies
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The life jackets near the operating stations for adults and/or children were not marked.
46 CFR 185.604(f)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 July 2025
Resolved 15 January 2026
Resolution: received email with proof of rectification see photo in doc. tab under deficiencies
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 January 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not undergone a drydock examination within the last two years. Complete drydock examination.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2025
Resolution: attended vessel for dry dock inspection
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 June 2024
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant [name withheld] side chock is damaged and is beginning to damage surrounding fiberglass. Mooring line going through chock could become damaged from chaffing. Vessel shall repair chock on STBD side.
46 CFR 184.300
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 June 2024
Resolved 30 July 2024
Resolution: Vessel has reapaired STBD chock. This deficency has been resolved.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessels FWD ring life buoy is displaying signs of failure. Vessel shall replace FWD ring life buoy.
46 CFR 176.808 (b)
Action required: 705 - Other - as specified
Due 18 June 2024
Resolved 1 July 2024
Resolution: FWD life buoy has been replaced. This deficency has been resolved.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 August 2023
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessel is required two fixed power pumps, and at the time of inspection only had 1 working bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 August 2023
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2021
Resolved
A vessel of 12 meters or more shall be provided with a whistle. Whistle is inoperable.
Rectify w/in 4 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2021
Resolved 19 June 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 June 2021
Resolved
Extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. Fire extinguisher for main deck not readily accessible or clearly visible within space.
Rectify w/in 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2021
Resolved 28 June 2021
Resolution: Operator provide satisfactory pictures rectifying deficiency
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2021
Resolved
Each child lifejacket must be separated from adult lifejackets. Adult and child lifejackets stowed in same space without divider.
Rectify w/in 7 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2021
Resolved 28 June 2021
Resolution: Operator provide satisfactory pictures rectifying deficiency
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2021
Resolved
Pressure vessels that have a net internal volume of less than 5 cubic feet and do not contain hazardous materials must be stamped with either the ASME "U" or "UM" symbol. Provide proof compressor meets above standard.
Rectify w/in 90 days.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2021
Resolved 14 September 2021
Resolution: Operator provided proof of installation of approved compressor and pressure vessel.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 May 2019
Resolved
The vessel's machinery space is not fitted with emergency lights. Install emergency lights in accordance with 46CFR183.432
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 14 June 2019
Resolution: Emergency lights illume as designed.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 May 2019
Resolved
The vessel is fitted with a pre-engineered fire extinguishing system in the machinery space. The activation of the system did not shut down the aft generator, all combustion engines within the space are required to shut down. The vessel is restricted from using the aft generator until fixed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 14 June 2019
Resolution: fire system test shut down aft generator.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 November 2018
Resolved
Vessel shall have B-15 Class fire boundaries surrounding galley's. Additionally, an integrated smoke or fire detector shall be installed in the galley area and an additional 40B:C fire extinguisher shall be maintained in the galley.
46CFR177.410(c)(1)
46CFR1821.500(b)/46CFR181.405(b); G-MSE PFM 1-99
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 December 2018
Resolved 19 November 2018
Resolution: During an Admin inspection, the attending MI's confirmed removal of the griddle system.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 July 2017
Resolved
Provide 2017 Coast Pilot and Light List publications.
Due 18 August 2017
Resolved 7 August 2017
Resolution: Received photo documentation of new 2017 Coast Pilot and Light List publications.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 July 2017
Resolved
Provide eye wash/dressing and aspirin as per 46 CFR 160.041-4.
Due 18 August 2017
Resolved 7 August 2017
Resolution: Received photo documentation of new eye wash, gauze dressing, and aspirin for first aid kit.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 18 July 2017
Resolved
Prove pre-employment drug testing for all employees.
Due 18 August 2017
Resolved 7 August 2017
Resolution: Received proof of pre-employment drug testing for all employees.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 July 2017
Resolved
Make all high-water alarm wires enclosed in junction boxes.
Due 18 August 2017
Resolved 7 August 2017
Resolution: Received photo documentation of required junction box assemblies for high water alarm wires.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 July 2017
Resolved
Blank off open fuse in distribution panel.
Due 18 August 2017
Resolved 7 August 2017
Resolution: Received photo documentation of correct blanked off fuse in distribution panel.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 25 July 2016
Resolved
Provide sewage valve locking mechanism in accordinace with 33CFR 159.7.
Due 12 August 2016
Resolved 4 August 2016
Resolution: Owner provided a valve locking mechanism on sewage system. See attached "Lexington Def Pictures" document.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 July 2016
Resolved
Provide light bulb guards in forward space and on 2nd deck space.
Due 12 August 2016
Resolved 4 August 2016
Resolution: Light bulb guards were provided in the two spaces mentioned above. The owner provided pictures. See attached "Lexington Def Pictures" document.