LEXINGTON
Passenger (Inspected) · Passenger Ship class · Built 2000s · USCG Northeast District (CGD-NE) · Other hulls named LEXINGTON
LEXINGTON is a 2000 passenger vessel (inspected). The Coast Guard has recorded 35 inspections since 2000, most recently in March 2026, along with 107 deficiencies, 1 operational control and 1 casualty investigation in 2019.
Records from 2000 to 2026. Most recent: inspection, 18 March 2026.
- Built
- 2000
- Last inspected
- 18 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 107 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2019
Identity
1095291
WDK5191
5300
Flag
UNITED STATES
367305460, 368062540
Maury page id
psix-5300
Inspections, by type
…with no type recorded2
Years with a record
22 calendar years (2000–2026)
The 35 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)87.8 ft × 23.9 ft × 7.8 ft
Registered tonnagegross 86 / net 59
ITC dimensions (L × B × D)87.8 ft × 23.9 ft × 7.8 ft
ITC tonnagegross 165 / net 60
BuilderSCARANO BOATBUILDING INC · ALBANY, NY, UNITED STATES · built 2000
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it86 - Regulatory (Subpart C or D), Gross Ton
165 - Convention (Subpart B), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
60 - Convention (Subpart B), Net Ton
165 - Convention (Subpart B), Gross Ton
59 - Regulatory (Subpart C or D), Net Ton
60 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK5191MMSI 368062540 · active · compulsorily equipped · granted 17 October 2018, expires 17 October 2028
WDD8986MMSI 367305460 · active · compulsorily equipped · granted 9 May 2017, expires 28 July 2027
WDA7472MMSI 366843690 · expired · compulsorily equipped · granted 23 March 2002, cancelled 26 May 2012
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 35
18 March 2026
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8327003
9 July 2025
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8173002
31 January 2025
Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8072698
11 June 2024
Deficiency Check · Internal Structural Exam · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7913365
9 August 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7764308
10 January 2023
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7616350
10 August 2022
Internal Structural Exam · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7600538
17 June 2021
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7227829
9 March 2021
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7152599
14 August 2020
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7032683
31 May 2019
Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 6705384
13 May 2019
DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6682853
19 November 2018
Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 6583194
29 October 2018
Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6570026
7 August 2018
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6502814
18 July 2017
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6212527
26 October 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6038929
25 July 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5952871
8 May 2016
Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 5937059
23 July 2012
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4387587
15 July 2011
Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 4082486
18 August 2008
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3302314
9 November 2007
Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3099542
25 July 2007
Annual Inspection · Deficiency Check · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3007629
16 August 2006
MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2755111
14 November 2005
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2534422
21 June 2005
COI Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2397405
13 September 2004
Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2194345
22 January 2004
Internal Structural Exam · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1990045
9 July 2003
MARPOL Annex V Examination · Annual Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1840411
10 July 2002
Deficiency Check · MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1647779
11 April 2002
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1761330
2 May 2001
Hull Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1436564
10 July 2000
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1381957
7 July 2000
COI Inspection · Plan Review "T" Boat · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1381947
Deficiency record · 107
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2026
Resolved
Fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. Aft Gen Fuel valve need adjusted it did not fully close during testing. Repair w/in 1 week
46 CFR 182.455(b)(4)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 March 2026
Resolved
Fuel shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. FWD gen emergency fuel shut off valve leaking. Repair w/ in 1 week.
46 CFR 182.455(b)(4)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 March 2026
Resolved
Fire extinguishing equipment installed on a vessel in excess of the requirements of §§ 181.400 and 181.500 must be designed, constructed, installed, and maintained in accordance with a recognized industry standard acceptable to the Commandant (CG-ENG-4). Vessel has recalled Heat Detector installed in the FWD Gen space. Additionally provide documentation describing what purpose or function this detector serves as there is no
detection panel.
46 CFR 181.120
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 July 2025
Resolved
In systems and applications where flexible hoses are permitted to be clamped:(1) Double hose clamping is required where practicable. The engine room generator muffler hose was missing a hose clamp.
46 CFR 146.182.410(d)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 July 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The life jackets near the operating stations for adults and/or children were not marked.
46 CFR 185.604(f)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 31 January 2025
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel has not undergone a drydock examination within the last two years. Complete drydock examination.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 June 2024
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. The ground tackle and mooring lines provided must be satisfactory for the size of the vessel, the waters on which the vessel operates, subject to the approval of the cognizant [name withheld] side chock is damaged and is beginning to damage surrounding fiberglass. Mooring line going through chock could become damaged from chaffing. Vessel shall repair chock on STBD side.
46 CFR 184.300
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 11 June 2024
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Vessels FWD ring life buoy is displaying signs of failure. Vessel shall replace FWD ring life buoy.
46 CFR 176.808 (b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 August 2023
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). Vessel is required two fixed power pumps, and at the time of inspection only had 1 working bilge pump.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2021
Resolved
A vessel of 12 meters or more shall be provided with a whistle. Whistle is inoperable.
Rectify w/in 4 days.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 17 June 2021
Resolved
Extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. Fire extinguisher for main deck not readily accessible or clearly visible within space.
Rectify w/in 7 days.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2021
Resolved
Each child lifejacket must be separated from adult lifejackets. Adult and child lifejackets stowed in same space without divider.
Rectify w/in 7 days.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 17 June 2021
Resolved
Pressure vessels that have a net internal volume of less than 5 cubic feet and do not contain hazardous materials must be stamped with either the ASME "U" or "UM" symbol. Provide proof compressor meets above standard.
Rectify w/in 90 days.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 May 2019
Resolved
The vessel's machinery space is not fitted with emergency lights. Install emergency lights in accordance with 46CFR183.432
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 May 2019
Resolved
The vessel is fitted with a pre-engineered fire extinguishing system in the machinery space. The activation of the system did not shut down the aft generator, all combustion engines within the space are required to shut down. The vessel is restricted from using the aft generator until fixed.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 14 November 2018
Resolved
Vessel shall have B-15 Class fire boundaries surrounding galley's. Additionally, an integrated smoke or fire detector shall be installed in the galley area and an additional 40B:C fire extinguisher shall be maintained in the galley.
46CFR177.410(c)(1)
46CFR1821.500(b)/46CFR181.405(b); G-MSE PFM 1-99
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 July 2017
Resolved
Provide 2017 Coast Pilot and Light List publications.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 July 2017
Resolved
Provide eye wash/dressing and aspirin as per 46 CFR 160.041-4.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 18 July 2017
Resolved
Prove pre-employment drug testing for all employees.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 18 July 2017
Resolved
Make all high-water alarm wires enclosed in junction boxes.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 18 July 2017
Resolved
Blank off open fuse in distribution panel.
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 25 July 2016
Resolved
Provide sewage valve locking mechanism in accordinace with 33CFR 159.7.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 July 2016
Resolved
Provide light bulb guards in forward space and on 2nd deck space.
Electrical › Electric Generation Source (service) › Ground Detection
Issued 23 July 2012
Resolved
JR 05- Remove household surge protector and 2 prong electronics over 100Volts
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 23 July 2012
Resolved
Replace two water light batteries with proper type.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 23 July 2012
Resolved
Obtain Light List and Coast Pilot
Accommodation/Occupational Safety › Refrigeration (air conditioning) › General
Issued 23 July 2012
Resolved
Remove old AC piping in chair room.
Communications › Public Address System › Cable Run
Issued 23 July 2012
Resolved
Remove dead end wires in beverage space and engine space
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 15 July 2011
Resolved
Provide proof of compliance with DAPI program.
Navigation › Piloting/Steering › Marine Charts
Issued 15 July 2011
Resolved
Provide updated charts for area of operatons.
Communications › Radio Communications › EPIRB
Issued 15 July 2011
Resolved
Replace EPIRB batteries with valid expiration date. Vessel is restricted to no more than 3 nautical miles from shore.
Documentation › Certificates/Documents › FCC SSL
Issued 25 July 2007
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Documentation › Certificates/Documents › FCC SSL
Issued 25 July 2007
Resolved
Provide FCC Safety Radio Certificate onboard vessel. Vessel is resticted to within 1000ft from shore until complete.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 25 July 2007
Resolved
Provide proof of crew enrollement in a drug testing program IAW 46 CFR Part 16, prior to carrying passengers for hire.
Lifesaving › Lifefloat › Serviceable
Issued 25 July 2007
Resolved
Make repairs to lifefloats as indicated by Marine Inspector, using manufacturers approved repair kit.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 25 July 2007
Resolved
Prove proper operation of floating waterlight in way of 22 person lifefloat.
Communications › Radio Communications › EPIRB
Issued 25 July 2007
Resolved
Replace antenna in way of 406MHz EPIRB.
Communications › Alarms/Indicators › High Water Alarm
Issued 25 July 2007
Resolved
Prove proper operation of visual highwater alarms at operation station for steering space, engine space and tank space.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 July 2007
Resolved
Prove proper operation of anchor light prior to carrying passengers for hire.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 August 2006
Resolved
Attach lanyard to forward chain locker hatch cover.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2006
Resolved
Properly dead end / reattach loose green wire in laz
Construction/Loadline › Structures › End Bulkhead
Issued 16 August 2006
Resolved
Make forward bulkhead in lazarette watertight.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2006
Resolved
Properly terminate dead end wires underneath bridge console.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 16 August 2006
Resolved
Remove debris / clean out area underneath bridge console.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 21 June 2005
Resolved
Provide current/valid CG Light List.
Navigation › Piloting/Steering › US Coast Pilot
Issued 21 June 2005
Resolved
Provide current/valid Coast Pilot.
Documentation › Markings/Placards › Warning Signs
Issued 21 June 2005
Resolved
Post Emergency Broadcast Placard by master operating station.
Communications › Radio Communications › EPIRB
Issued 21 June 2005
Resolved
Register EPIRB with NOAA - Route shall be limited to 3NM until registration renewed.
Communications › Radio Communications › EPIRB
Issued 21 June 2005
Resolved
Install new battery onto EPRIB - limited to 3NM until battery replaced.
Lifesaving › Lifefloat › Retroreflective Material
Issued 21 June 2005
Resolved
Replace retro - tape on Lifefloat.
Lifesaving › Lifebuoys › Stowage
Issued 21 June 2005
Resolved
Switch retention clip/splice on ring buoy.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Location
Issued 21 June 2005
Resolved
Relocate B-II fire extinguisher closest to warmer (oven) in galley.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 21 June 2005
Resolved
Remove tables stored in galley, escape access.
Electrical › Electrical Distribution System (service) › Wiring
Issued 21 June 2005
Resolved
Secure cabling/wiring in galley overhead in proximity to heat exhaust fan.
Accommodation/Occupational Safety › Heating › Catch Pan
Issued 21 June 2005
Resolved
Remove (griddle) in galley permanently -or- install proper grease extraction hood/fan to include a fixed firefighting system.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 September 2004
Resolved
Waterlight is not not working. Bulb is blown. Vsl limited withing 3 NM until cleared.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 13 September 2004
Resolved
Expired hydro release on EPIRB. Paz count is reduced to 132 during night ops until cleared.
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 9 July 2003
Resolved
Ice maker PVC pipe connection broken. LEGACY COMPONENT DESC: Ice maker PVC pipe leaking
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 9 July 2003
Resolved
Retaining ring for shore tie cracked.
Electrical › Electric Supply System (service) › Cable
Issued 9 July 2003
Resolved
Dead end cable required to be properly terminated in junction box in tank room.
Engineering › Fuel Oil Service System › Filter
Issued 9 July 2003
Resolved
Gaskets under flame impingement bowls leaking.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 9 July 2003
Resolved
Improper hose betweem MSD tank and overboard discharge.
Lifesaving
Issued 9 July 2003
Resolved
Inop water lights on two life floats. LEGACY COMPONENT DESC: Water Lights
Fire Fighting › Fire Pumps
Issued 9 July 2003
Resolved
Inoperable pressure guage on fixed fire pump. LEGACY COMPONENT DESC: Pressure Guage
Stability › Watertight Integrity
Issued 9 July 2003
Resolved
Main deck water leak through bolt hole into engine room only during heavy rain. LEGACY COMPONENT DESC: Main deck water leak
Personnel › Training
Issued 9 July 2003
Resolved
Unable to conduct MOB drill due to master hospitalization. LEGACY COMPONENT DESC: MOB Drill
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 July 2003
Resolved
Expired meds.
Documentation › Certificates/Documents
Issued 10 July 2002
Resolved
Post stability letter and emergency instructions in wheelhouse and post COI in conspicuous location visible to passengers. Post lifejacket donning placard on each deck.
Documentation › Certificates/Documents
Issued 10 July 2002
Resolved
Provide copy of valid FCC safety certificate. Vessel is restricted to no more than 1000 ft from shore until corrected. LEGACY COMPONENT DESC: FCC SSL
Electrical › Lighting (service)
Issued 10 July 2002
Resolved
Permanently install anchor light (UL 1104). LEGACY COMPONENT DESC: Lighting Fixture
Lifesaving
Issued 10 July 2002
Resolved
Renew hydrostatic release for EPIRB and renew registration.
Accommodation/Occupational Safety › Occupational Safety
Issued 10 July 2002
Resolved
Secure glassware crates in galley.
Electrical › Lighting (emergency)
Issued 10 July 2002
Resolved
Prove proper operation of port main deck exit light. LEGACY COMPONENT DESC: Lighting Fixture
Lifesaving
Issued 10 July 2002
Resolved
Repair upper aft lifefloat body IAW manufacturers recommendations (6" tear).
Electrical › Electrical Distribution System (service)
Issued 10 July 2002
Resolved
Install junction box cover beneath stairs. LEGACY COMPONENT DESC: Junction Box
Electrical › Lighting (emergency)
Issued 10 July 2002
Resolved
Install seperate visual indicators for bilge high level alarms at operating station. LEGACY COMPONENT DESC: Lighting Fixture
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 10 July 2002
Resolved
Install device to automatically shut down main engines prior to release of fixed fire extinguishing system in E/R. LEGACY COMPONENT DESC: Operating Controls
Fire Fighting › Ventilation Systems
Issued 10 July 2002
Resolved
Install closure device to engine room vent. LEGACY COMPONENT DESC: Duct Hatches
Fire Fighting › Fire Hoses
Issued 10 July 2002
Resolved
Provide new fire hose which meets UL19 standard. LEGACY COMPONENT DESC: Condition
Accommodation/Occupational Safety › Occupational Safety
Issued 10 July 2002
Resolved
Provide portable hand bilge pump capable of reaching bilge of compartment #1.
Engineering › Compressed Air System (start air)
Issued 10 July 2002
Resolved
Remove unapproved pressure vessel from fuel tank compartment (must be ASME U or ASME UM approved). LEGACY COMPONENT DESC: Receiver/Bottle
Electrical › Lighting (service)
Issued 10 July 2002
Resolved
Install blank to old light fixture in tank space. LEGACY COMPONENT DESC: Lighting Fixture
Electrical
Issued 7 July 2000
Resolved
PROVIDE METAL WIRE SUPPORTS FOR ENGINE ROOM WIRING AND GENERAL SUPPORTS THROUGHOUT VESSEL AT NO MORE THAN 24 INCH INTERVALS.
Construction/Loadline
Issued 7 July 2000
Resolved
INSTALL 316 STAINLESS STEAL WASTAGE ROD IN CEMENT KEEL AT NEXT COAST GUARD INSPECTED DRYDOCK.
Navigation
Issued 7 July 2000
Resolved
PROVIDE SHIP'S BELL WITH A MINIMUM 200MM (7.9IN) OPENING AS PER ANNEX III OF COLREGS
Fire Fighting
Issued 7 July 2000
Resolved
PROVIDE FIXED FIREFIGHTING PLANS FOR FIREBOY SYSTEM TO BOSTON MSO.
Lifesaving
Issued 7 July 2000
Resolved
PERMANENTLY STENCIL DRAFT MARKINGS ON VESSEL IN PLACE OF DUCT TAPE.
Construction/Loadline
Issued 7 July 2000
Resolved
PROVIDE ACCEPTABLE BULKHEAD PENNETRATION SEALANT MATERIAL TO SATISFACTION OF BOSTON MSO. PLANS APPROVED USING 3M5200. VSL BUILT USING SIKAFLEX291.
Lifesaving
Issued 7 July 2000
Resolved
VESSEL NOT TO CARRY PASSENGERS UNTIL SATISFACTORY FIRE AND BOAT DRILLS CONDUCTED IN PRESENCE OF BOSMS MARINE INSPECTOR.
Accommodation/Occupational Safety
Issued 7 July 2000
Resolved
PROVIDE A LADDER WITH RISERS BETWEEN 8 AND 12 INCHES FOR ACCESS TO PILOT HOUSE FROM OFFICE AREA/CHANGING ROOM.
Lifesaving
Issued 7 July 2000
Resolved
DURING PERIODS DETERMINED BY MSO BOSTON TO BE COLD WATER MONTHS, VESSEL TOTAL CAPACITY REDUCED TO 154 UNLESS PRIMARY LIFESAVING INCREASED TO 157.
Lifesaving
Issued 7 July 2000
Resolved
MAX CAPACITY OF VESSEL IS RESTRICTED TO 154UNTIL PRIMARY LIFESAVING COVERS 157 TOTAL PERSONS.
Navigation
Issued 7 July 2000
Resolved
HARD MOUNT AIR HOSE FOR SHIPS WHISTLE.
Construction/Loadline
Issued 7 July 2000
Resolved
PROVIDE VAPORTIGHT DOOR PLANS TO BOSTON MSO AND PROOVE DOOR VAPORTIGHT.
Accommodation/Occupational Safety
Issued 7 July 2000
Resolved
MOUNT TANK ROOM AIR CONDITIONER COOLING PUMP.
Construction/Loadline
Issued 7 July 2000
Resolved
SEAL BULKHEAD PENNETRATIONS FROM BOTH SIDES. CAULKING FROM ONE SIDE IS UNSAT.
Engineering
Issued 7 July 2000
Resolved
INSTAL BELT GUARD ON STARBOARD ENGINE FRONT.
Engineering
Issued 7 July 2000
Resolved
DOUBLE CLAMP ALL SMOOTH SLEEVE FLEX HOSE CONNECTIONS FOR VITAL SYSTEMS (IE EXHAUST, MSD, ENGINES...)
Construction/Loadline
Issued 7 July 2000
Resolved
REPAIR LEAKING JABSCO PUMP DISCHARGE ELBOW.
Fire Fighting
Issued 7 July 2000
Resolved
MOUNT PRIMARY FIRE PUMP.
Navigation
Issued 7 July 2000
Resolved
PLANS FOR AUTO PILOT TO BE SUBMITTED TO BOSTON MSO PRIOR TO OPERATION, INCLUDING ELECTRICAL AND MATERIAL INSTALLATION.
Navigation
Issued 7 July 2000
Resolved
PROVIDE TIDE / CURRENTS TABLES, LIGHT LIST, AND COAST PILOT OR ELDRIDGE FOROPERATING AREA.
Lifesaving
Issued 7 July 2000
Resolved
MARK UPPER DECK FOR 112 PASSENGERS MAX CAPACITY.
Navigation
Issued 7 July 2000
Resolved
PROPERLY MOUNT MAGNETIC COMPASS AND PROPER OPERATION OF COMPASS LIGHT.
Deck/Cargo
Issued 7 July 2000
Resolved
PROOVE ACCEPTABILITY OF ANCHOR/GEAR TO BOSTON MSO.
Accommodation/Occupational Safety
Issued 7 July 2000
Resolved
HARD MOUNT GREY WATER FLEX HOSE IN COMPARTMENT #2 IN WAY OF VALVES AND FITTINGS.
Electrical
Issued 7 July 2000
Resolved
INSTAL CURRENT TRANSFORMER ON AC GENERATOR NEUTRAL TO GROUND.
Casualty record · 1
31 May 2019Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6705384
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.