Records from 1981 to 2009. Most recent: inspection, 8 July 2009.
Inspection history · 93
8 July 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3527802
31 July 2008
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3397658
28 February 2008
Hull Examination
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3142731
10 July 2007
Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2990336
28 August 2006
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2762015
5 December 2005
Re-Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2545941
17 April 2005
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2338263
30 March 2005
Underwater Inspection in lieu of Drydock
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2325044
4 October 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2212928
12 May 2004
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2070375
20 October 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1933562
1 April 2003
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1788176
28 March 2003
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1764276
14 November 2002
Annual Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1705280
27 June 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1640023
11 October 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1075565
15 August 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1384861
13 May 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1064148
28 August 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 823858
21 August 2000
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468987
8 July 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 820136
14 June 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 818709
13 May 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817771
13 May 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1049461
29 April 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 817204
18 April 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 819229
20 March 2000
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1412064
12 November 1999
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 806334
24 August 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 780062
18 August 1999
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1388885
13 October 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472233
17 March 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1446607
18 February 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1113135
12 January 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 785777
21 August 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 787076
20 August 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380972
4 August 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 781936
4 August 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1117315
9 July 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778985
16 June 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1110773
31 March 1997
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1093907
11 December 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1093371
31 October 1996
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1416396
25 October 1996
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 851694
27 October 1995
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1424158
31 August 1995
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398320
31 July 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1184959
8 June 1995
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1422522
22 March 1995
Hull Examination · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1377364
9 December 1994
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1143873
1 November 1994
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1460754
12 July 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 676086
30 June 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 67768
30 June 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 188177
21 March 1994
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 855728
9 February 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 852459
8 February 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1163215
19 October 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 843187
11 September 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1716
1 September 1993
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1468298
16 July 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 844279
3 June 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1135200
22 April 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1135515
24 March 1993
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1359522
28 July 1992
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 958128
20 November 1991
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1247030
25 October 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1255549
5 September 1991
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1006571
7 November 1990
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1236211
26 July 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1235533
13 July 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1217089
3 July 1990
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 929118
28 March 1990
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 922891
14 September 1989
Drydock Extension · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1352821
6 October 1988
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1195007
15 February 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1024895
21 January 1988
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1014579
8 October 1987
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1320940
18 September 1987
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1332633
15 October 1986
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1317151
25 October 1985
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 995186
27 June 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1291446
28 April 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 980178
28 February 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 990967
11 December 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1285206
25 July 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1280507
5 April 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1281872
24 February 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1278958
26 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967920
29 November 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1271191
5 October 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 964888
11 August 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1274424
27 October 1981
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283300
Construction/Loadline › Hull › Hull Plating
Issued 28 February 2008
No resolution recorded
Complete Phase II of SEILOD during next rig move and send report to local OCMI.
Action required: 705 - Other - as specified
Construction/Loadline › Hull › Hull Plating
Issued 30 March 2005
Resolved
Mulltiple repairs noted during inspection, SEE MINS for details.
Due 30 June 2005
Resolved 5 July 2005
Resolution: Cleared by ABS on June 14, 2005 report in file.
Construction/Loadline › Hull › Hull Plating
Issued 30 March 2005
Resolved
Complete Phase II of UWILD (mat and legs)
Due 30 June 2005
Resolved 5 July 2005
Resolution: Completed June 14, 2005 witnessed by ABS
Construction/Loadline
Issued 1 April 2003
Resolved
Multiple callouts for hull repairs issued. See narrative for specific items
Extended due date May 7, 2003.
Due 16 May 2003
Resolved 23 May 2003
Construction/Loadline › Structures
Issued 14 November 2002
Resolved
INSERT (18" X 18") THE WASTED SECTION OF THE DECKHOUSE BULKHEAD WHERE IT MEETS THE MAIN DECK. LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 14 December 2002
Resolved 19 November 2002
Resolution: Received a fax from rig OIM attesting to the completion of the requirement.
Fire Fighting
Issued 15 August 2001
Resolved
CONDUCT FIRE AND ABANDON RIG DRILL.
Condition: Unknown
Due 15 August 2001
Resolved 15 August 2001
Lifesaving
Issued 21 August 2000
Resolved
ALL BREATHING AIR BOTTLES IN BOTH LIFEBOATS NEED TO BE HYDRO'D.
Condition: Unknown
Due 21 August 2000
Resolved 21 August 2000
Construction/Loadline
Issued 20 March 2000
Resolved
Submit copy of diver's written report and video tape(s) and ABS UWILD survey report to MSO New Orleans.
Condition: Unknown
Due 20 March 2000
Resolved 20 March 2000
Construction/Loadline
Issued 20 March 2000
Resolved
Conduct final portion of Phase II of Special Examination in Lieu of Drydocking (diver's swim-by of mat and underside of mat skirt) at next rig move.
Condition: Unknown
Due 20 March 2000
Resolved 20 March 2000
Construction/Loadline
Issued 20 March 2000
Resolved
Conduct representative ultrasonic gaugings on lowest longitudinal and associated lower section of of sideshell plating in no. 3 stbd salt water tank. Submit gauging repor to [name withheld].
Condition: Unknown
Due 20 March 2000
Resolved 20 March 2000
Lifesaving
Issued 13 October 1998
Resolved
CONDUCT 1.1 OPERATIONAL TEST OF THE LIFEBOATS RELEASE GEARS OR ALTERNATE TEST SUBJECT TO THE APPROVAL OF THE COGNIZANT OCMI.
Condition: Unknown
Due 13 October 1998
Resolved 13 October 1998
Construction/Loadline
Issued 17 March 1998
Resolved
Prove proper operation of all watertight doors and build up gasket materialor replace as necessary. Repair as original, lower coaming of weathertightand watertight doors where wasted and coaming to engine room hatch on main deck.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Construction/Loadline
Issued 17 March 1998
Resolved
Submit repair proposal to [name withheld] on deficiencies issued by ABS surveyor dated 17MAR98 from Intermediate Survey, in ballast tanks No.7 starboard and No.3 port concerning wasted and pitted stiffeners and bulkheads.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Lifesaving
Issued 17 March 1998
Resolved
Renew three deteriorated life ring buoys on main deck. Replace missing ring buoy at port-forward station. Replace missing waterlight brackets at ring buoy stations.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Construction/Loadline
Issued 17 March 1998
Resolved
Crop and renew, wasted underdeck drill floor stiffeners and repair previousdeck plate insert at kelly chuck by tieing in new insert to weld seam and providing proper stress relief cutbacks. Make full penetration weld. Finalrepairs to be witnessed by attending marine inspector.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Engineering
Issued 17 March 1998
Resolved
Crop and renew as original, wasted fuel vent riser and sounding tube standpipe on main deck behind fire station No.5.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Construction/Loadline
Issued 17 March 1998
Resolved
Conduct NDE of leg-to-mat critical connections in presence of attending marine inspector and conduct mat swim-by. Submit dive report and video to [name withheld].
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Construction/Loadline
Issued 17 March 1998
Resolved
Repair as original, ruptured overboard heat exchanger line in void tank No.6 starboard. After repairs, make tank ready for inspection for attending marine inspector.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Construction/Loadline
Issued 17 March 1998
Resolved
In No.5 starboard void, gauge internal bulkheads approximately 24 inches from bottom plate where pitted. Gauge bottom stiffeners. Submit report with original nominal thicknesses to [name withheld] and renew lower portion of sounding tube and striker pad.
Condition: Unknown
Due 17 March 1998
Resolved 17 March 1998
Lifesaving
Issued 20 August 1997
Resolved
REVISE POLICY TO COMPLY WITH THE APPLICABLE PORTIONS OF THE REVISIONS TO 46CFR107-109. REFERENCE FEDERAL REGISTER VOL. 61, NO. 98, DATED MAY 20, 1996.
Condition: Unknown
Due 20 August 1997
Resolved 20 August 1997
Fire Fighting
Issued 20 August 1997
Resolved
INSTALL FIRE DOOR BETWEEN GALLEY/MESS AND PASSAGEWAY.
Condition: Unknown
Due 20 August 1997
Resolved 20 August 1997
Construction/Loadline
Issued 20 August 1997
Resolved
REPLACE MISSING OR BROKEN STUDS THAT SECURE MANHOLE COVER IN MECHANIC'S SHOP.
Condition: Unknown
Due 20 August 1997
Resolved 20 August 1997
Fire Fighting
Issued 20 August 1997
Resolved
CROP AND RENEW FIREMAIN PIPING AT STATION #5.
Condition: Unknown
Due 20 August 1997
Resolved 20 August 1997
Lifesaving
Issued 31 October 1996
Resolved
PROVIDE MISSING DATA PLATE FOR #1 LIFEBOAT DAVIT.
Condition: Unknown
Due 31 October 1996
Resolved 31 October 1996
Accommodation/Occupational Safety
Issued 31 August 1995
Resolved
REPLACE OR SEND IN FOR ADJUSTING AND RETAGGING, FOUR P-TANK RELIEF VALVES (MUST BE SENT TO ASME AUTHORIZED SHOP FOR RESETTING AND RESTAMPING OF LABELTO 40 PSI).
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Electrical
Issued 31 August 1995
Resolved
MAKE REAPIRS TO AND PROVE PROPER OPERATIONN OF BOTH SERVICE GENERATOR REVERSE POWER RELAYS.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Fire Fighting
Issued 31 August 1995
Resolved
MAKE REPAIRS TO FIREMAIN TO MUDPIT SALT WATER ISOLATION VALVE (ELECTRO- PNEUMATIC) SO THAT VALVE FULLY CLOSES AND OPENS FROM BOTH REMOTE SWITCH LOCATIONS.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Lifesaving
Issued 31 August 1995
Resolved
RELOCATE RING BUOY AND FIRE STATION #11 ON STARBOARD AFT SIDE SO THAT THEY ARE READILY ACCESSIBLE WITHOUT CLIMBING OVER OR UNDER NEWLY INSTALLED PIPING.
Condition: Unknown
Due 31 August 1995
Resolved 31 August 1995
Construction/Loadline
Issued 8 June 1995
Resolved
Crop and renew wasted outboard side longitudinals in port forward saltwatertank and also overhead deck stringers at forward and aft bulkheads where stringers are thinning at gusset connections.
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995
Construction/Loadline
Issued 8 June 1995
Resolved
Renew or repair check valves in saltwater overboard discharges in port and stbd voids.
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995
Construction/Loadline
Issued 8 June 1995
Resolved
Crop and renew wasted overhead deck stringers in stbd aft saltwater tank inoutboard bay.
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995
Construction/Loadline
Issued 8 June 1995
Resolved
Repair or renew broken valve guide (disc type valve) in main saltwater suction valve.
Condition: Unknown
Due 8 June 1995
Resolved 8 June 1995
Construction/Loadline
Issued 22 March 1995
Resolved
Conduct topside portion of SEILODD (Special Examination in Lieu of Drydocking) at next jack-up on location. Make available: all voids, pre- load tanks (salt water tanks), drill water tanks and associated overboard gate and/or check valves.
Condition: Unknown
Due 22 March 1995
Resolved 22 March 1995
Electrical
Issued 1 November 1994
Resolved
REPAIR/RENEW 4-WAY EXPLOSION-PROOF JUNCTION BOX AT FORWARD BULKHEAD OF MUDPIT ROOM (COVER MISMATCHED WITH HOUSING).
Condition: Unknown
Due 1 November 1994
Resolved 1 November 1994
Accommodation/Occupational Safety
Issued 1 November 1994
Resolved
DISCONNECT CROSS CONNECT FROM POTABLE WATER SYSTEM AND SANITARY WATER SYSTEM.
Condition: Unknown
Due 1 November 1994
Resolved 1 November 1994
Lifesaving
Issued 1 November 1994
Resolved
REPAIR SELF CLOSING GAS TIGHT DOORS (3 EACH) IN MUDPIT ROOM (GASKETS TOO THICK AND/OR COUNTERWEIGHT INSUFFICIENT).
Condition: Unknown
Due 1 November 1994
Resolved 1 November 1994
Lifesaving
Issued 1 November 1994
Resolved
MAKE REPAIRS TO STBD LIFEBOAT AS FOLLOWS: 1-REPAIR OUTBOARD STANCHION SUPPORT WHERE FIBERGLASS BROKEN/2-REPAIR LIFELINE AROUND OUTSIDE OF LIFEBOAT/3-HYDROSTATICALLY TEST AIR BOTTLES.
Condition: Unknown
Due 1 November 1994
Resolved 1 November 1994
Electrical
Issued 1 November 1994
Resolved
REPAIR/RENEW ALL WASTED EXPLOSION PROOF FITTINGS IN SHALE SHAKER AREA INCLUDING WASTED MOTOR CONTROLLERS, J-BOXES, EYS FITTINGS, ETC.
Condition: Unknown
Due 1 November 1994
Resolved 1 November 1994
Construction/Loadline
Issued 24 March 1993
Resolved
PROVIDE GAUGINGS AND ORIGINAL SCANTLINGS OF STARBOARD FWD WING VOID AND DECK OF MOTOR ROOM.
Condition: Unknown
Due 22 April 1993
Resolved 7 May 1993
Construction/Loadline
Issued 24 March 1993
Resolved
COMPLETE UNDERWATER SWIM-BY OF THE BOTTOM OF THE MAT.
Condition: Unknown
Due 24 March 1993
Resolved 24 March 1993
Deck/Cargo
Issued 5 September 1991
Resolved
PROVE PROPER OPERATION OF ALL DRY BULK TANK RELIEF VALVES
Condition: Unknown
Due 5 September 1991
Resolved 5 September 1991
Fire Fighting
Issued 5 September 1991
Resolved
PROPERLY MARK CO2 CONTROLS TO PAINT LOCKER
Condition: Unknown
Due 5 September 1991
Resolved 5 September 1991
Deck/Cargo
Issued 5 September 1991
Resolved
RESTENCIL GENERAL ALARM BELLS IN THE GENERATOR ROOM AND AIR COMPRESSOR ROOM
Condition: Unknown
Due 5 September 1991
Resolved 5 September 1991
Deck/Cargo
Issued 5 September 1991
Resolved
PROVE PROPER OPERATION OF THE GENERAL ALARM BELLS IN THE MUD-PUMP, GENERATOR & FIRE PUMP ROOM
Condition: Unknown
Due 5 September 1991
Resolved 5 September 1991
Lifesaving
Issued 5 September 1991
Resolved
PROVE PROPER OPERATION OF BOTH LIFEBOAT RELEASING MECHANISMS AND SPRINKLER SYSTEMS
Condition: Unknown
Due 5 September 1991
Resolved 5 September 1991
Electrical
Issued 5 September 1991
Resolved
PROPERLY REPACK SPEAKER WIRE NEAR SHAKER AND PROPERLY REMOUNT WIRES TO OVERHEAD OR BULKHEAD.
Condition: Unknown
Due 5 September 1991
Resolved 5 September 1991
Construction/Loadline
Issued 28 March 1990
Resolved
OPEN-UP MUD PIT DUMP VALVES FOR INSPECTION DURING NEXT RIG MOVE.
Condition: Unknown
Due 28 March 1990
Resolved 28 March 1990
Construction/Loadline
Issued 28 March 1990
Resolved
CONDUCT VISUAL UNDERWATER SWIM-BY INSPECTION OF MAT BOTTOM AND SCOUR-SKIRT-ING DURING NEXT RIG MOVE.
Condition: Unknown
Due 28 March 1990
Resolved 28 March 1990
Construction/Loadline
Issued 21 January 1988
Resolved
REPAIR APROX 25' OF MAIN DECK RAILING ON PORT SIDE AND APROX 10' OF SCUPPEREDGE THAT IS MISSING AND BENT
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Lifesaving
Issued 21 January 1988
Resolved
REPLACE 1 RING LIFEBOUY AND FLOAT LITE THAT IS MISSING DUE TO ACCIDENT
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Deck/Cargo
Issued 21 January 1988
Resolved
REINSTALLATION OF PORT CRANE TO CONFORM TO USCG REGULATIONS. ALL WELDING AND TESTING TO BE WITNESSED BY USCG AND CRANE CLASSIFICATION SOCIETY
Condition: Unknown
Due 21 January 1988
Resolved 21 January 1988
Lifesaving
Issued 18 September 1987
Resolved
MAKE OPERABLE THE PORT SIDE LIFEBOAT DAVIT LIMIT SWITCH.
Condition: Unknown
Due 18 September 1987
Resolved 18 September 1987
Construction/Loadline
Issued 18 September 1987
Resolved
REPAIR THE AIRTIGHT DOORS BETWEEN THE MUD PIT AND MUD PUMP ROOMS AND BETWEEN THE MUD PIT AND CHEMICAL STORAGE ROOMS.
Condition: Unknown
Due 18 September 1987
Resolved 18 September 1987
Lifesaving
Issued 18 September 1987
Resolved
PROVIDE ONBOARD ONE ADDITIONAL LIFECAPSULE WITH A MINIMUM CAPACITY OF 48 PERSONS AND MAKE CAPSULE AVAILABLE FOR INSPECTION OF EQUIPMENT AND SUPPLIESAND CONDUCT OPERATIONAL TEST OF SAME IN PRESENCE OF C. G. INFLATABLE LIFERAFTS WITH TOTAL CAPACITY OF 48 PERSONS MAY BE SUBSTITUTED.
Condition: Unknown
Due 18 September 1987
Resolved 18 September 1987
Construction/Loadline
Issued 15 October 1986
Resolved
COMPLETESPECIAL UNDERWATER SURVEY IN LIEU OF DRYDOCKING DURING NEXT RIG MOVE BUT NOT LATER THAN 25OCT87.
Condition: Unknown
Due 15 October 1986
Resolved 15 October 1986
Electrical
Issued 11 December 1984
Resolved
PROVIDE PROPER SEALS FOR MONITORING EQUIPMENT INTHE PIT ROOM.
Condition: Unknown
Due 11 December 1984
Resolved 11 December 1984
Electrical
Issued 11 December 1984
Resolved
MAKE ALL AIR PURGING ON THE DRILL FLOOR OPERATIONAL.
Condition: Unknown
Due 11 December 1984
Resolved 11 December 1984
Electrical
Issued 11 December 1984
Resolved
PROPERLY INSTALL ELECTRICAL CABLE WITH APPROVED SEALS (EYS) IN PIT VOLUME INDICATOR IN WAY OF DRILLERS CONSOLE.
Condition: Unknown
Due 11 December 1984
Resolved 11 December 1984
Electrical
Issued 11 December 1984
Resolved
INSTALL A PROPER EYS SEAL ON THE ELECTRIC PUMP MOTOR BELOW THE SHALE SHAKER
Condition: Unknown
Due 11 December 1984
Resolved 11 December 1984
Electrical
Issued 11 December 1984
Resolved
RENEW OR REPAIR INOPERATIVE EMERGENCY LIGHT IN MUD PIT ROOM.
Condition: Unknown
Due 11 December 1984
Resolved 11 December 1984
Construction/Loadline
Issued 11 December 1984
Resolved
MAKE SELF CLOSURES ON MUD PIT ROOM DOORS OPERATIONAL SO THAT DOORS CLOSE TO MAKE A GAS TIGHT SEAL.
Condition: Unknown
Due 11 December 1984
Resolved 11 December 1984
Electrical
Issued 11 December 1984
Resolved
RENEW FRACTURED EXPLOSION PROOF RECEPTICAL ON PORT SIDE OF DRILL FLOOR IN WAY OF DOORWAY.
Condition: Unknown
Due 11 December 1984
Resolved 11 December 1984
Electrical
Issued 11 December 1984
Resolved
RENEW MISSING BOLTS IN EXPLOSION PROOF ELECTRICAL PANELS AND FIXTURES IN SHALE SHAKER AREA AND ON DRILL FLOOR IN WAY OF DRILLERS CONSOLE.
Condition: Unknown
Due 11 December 1984
Resolved 11 December 1984
Unknown
Issued 24 February 1984
Resolved
THE FOLLOWING DEFICIENCY IS FOR THE J STORM XVII, DN641802.
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984
Unknown
Issued 24 February 1984
Resolved
CONDUCT A VIDEO EXAMINATION OF THE MAT BOTTOM AND SKIRT IN THE PRESENCE OF A COAST GUARD INSPECTOR.
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984
Unknown
Issued 26 October 1983
Resolved
CONDUCT AN OPERATIONAL TEST OF THE VESSEL'S ANCHOR WINDLASS.
Condition: Unknown
Due 26 October 1983
Resolved 26 October 1983
Unknown
Issued 26 October 1983
Resolved
DEMONSTRATE THE OPERATION OF THE EMERGENCY GENERATOR OVERSPEED TRIP.
Condition: Unknown
Due 26 October 1983
Resolved 26 October 1983
Unknown
Issued 26 October 1983
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE J. STORM XVII, DN641802.
Condition: Unknown
Due 26 October 1983
Resolved 26 October 1983
Unknown
Issued 26 October 1983
Resolved
CONDUCT A FIRE AND ABANDON RIG DRILL WITH THE FULL COMPLEMENT OF PERSONNEL ASSIGNED TO THE RIG.
Condition: Unknown
Due 26 October 1983
Resolved 26 October 1983
Unknown
Issued 26 October 1983
Resolved
CONDUCT AN OPERATIONAL TEST OF BOTH LIFE CAPSULES IN THE WATER.
Condition: Unknown
Due 26 October 1983
Resolved 26 October 1983