Records from 1981 to 2018. Most recent: inspection, 10 October 2018.
Inspection history · 59
10 October 2018
Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6558464
8 October 2018
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6558456
7 August 2018
Drydock Exam · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6496795
11 July 2017
Deficiency Check · COI Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6201119
27 July 2016
Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5948449
29 April 2016
Type not recorded
No type recorded · USCGC CYPRESS (WLB 210) · USCG Heartland District (CGD-H) · Activity 5887072
10 July 2012
Deficiency Check · Drydock Exam · COI Inspection · DAPI Audit
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4349246
21 July 2009
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3535281
17 July 2008
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3269887
10 July 2008
Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3254760
12 July 2007
COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2992477
10 July 2006
Re-Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2708636
8 March 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2598630
24 October 2005
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2520914
21 October 2005
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2522586
20 October 2005
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2565758
12 July 2005
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2410180
8 July 2004
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2054466
19 May 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2072203
28 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2072120
3 March 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2017890
1 July 2003
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1832258
22 March 2003
Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 1761468
15 November 2002
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1718071
9 July 2002
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1640295
17 July 2001
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466786
26 September 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1054014
21 September 2000
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 821981
20 September 2000
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 822221
19 September 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 138833
21 July 2000
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1427869
27 July 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1384212
2 July 1999
Damage Survey
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1095416
23 September 1998
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 804698
23 July 1998
Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1411718
7 December 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 777650
25 July 1997
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456503
25 July 1996
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1448791
26 July 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421002
26 July 1994
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1363025
5 July 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 111042
14 September 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 833149
20 July 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1466847
24 July 1992
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1415759
25 July 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1247373
10 January 1991
Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1240509
8 August 1990
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212843
29 January 1990
Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1218945
8 August 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1339997
22 December 1988
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1349738
11 August 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1345468
28 June 1988
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1343648
12 August 1987
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1003587
10 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1310600
10 May 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281059
26 May 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 968410
4 March 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275117
2 June 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1276704
29 May 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 963822
Lifesaving › Lifefloat › Serviceable
Issued 11 July 2017
Resolved
One of the 25-man lifefloats was found unserviceable due to a severe crack in it. MAX allowed persons onboard is reduced to 25 until lifefloat is replaced in kind or repaired to the satisfaction of attending USCG Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 11 August 2017
Resolved 3 August 2017
Resolution: Life float was repaired and verified by attending marine inspector.
Fire Fighting › Portable Foam Applicators › General
Issued 11 July 2017
Resolved
Installed foam eductor is of the variable concentration type and was found with setting markings unreadable and adjustment knob stuck in place. Vessel restricted from carrying portable tanks containing hazmat as per 46 CFR 172.101 until the adjustable prtion is replaced in kind.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 July 2017
Resolved 3 August 2017
Resolution: Eductor was replaced.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 27 July 2016
Resolved
Vessel does not have any smoke detecotrs in accomadation spaces. Provide proof of installation of CFR rquired smoke detectors to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 6 August 2016
Resolution: Received proof of CFR required smoke detectors installed in accomodation spaces.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 27 July 2016
Resolved
Vessel is missing lagging on port and stbd outboard engines. Place appropriate lagging on exposed piping.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 24 August 2016
Resolution: Received proof of proper lagging placed on both port and starboard outboard engine exhaust piping.
Electrical › Electric Supply System (service) › Cable
Issued 27 July 2016
Resolved
Electrical cabling in the the engine room was inadequately supported by a plastic zip ties. Provide proof of proper installation of metal cable supports to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 August 2016
Resolved 6 August 2016
Resolution: Received proof of proper metal cable supports for inadequately supported areas of cabling in engine room.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 July 2016
Resolved
Remove exposed wires for previously installed radio in galley to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2016
Resolved 5 August 2016
Resolution: Vessel personnel installed a junction box in the place of the exposed wiring.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 10 July 2012
Resolved
Provide proper panels for electrical breaker boxes (also identify amperage & circuit for each breaker).
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Electrical › Electrical Distribution System (service) › Wiring
Issued 10 July 2012
Resolved
Remove abandoned/unused wiring on Starboard Maine Diesel Engine.
Action required: 705 - Other - as specified
Due 13 August 2012
Resolved 16 July 2012
Construction/Loadline › Hull › Hull Plating
Issued 17 July 2008
Resolved
Fractures around the Port Gen Exhaust need to be repaired
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 July 2008
Construction/Loadline › Penetrations › Weld
Issued 17 July 2008
Resolved
Several fractures in the Hatch. Hatch repairs during visit did not meet standards required to crop and renew hatch
Action required: 17 - Rectify deficiencies prior to departure
Due 18 July 2008
Resolved 18 July 2008
Engineering
Issued 20 September 2000
Resolved
MAKE PERMANENT REPAIRS TO PORT MAIN DIESEL ENGINE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR. VESSEL NOT TO BE OPERATED AS PER C.O.I. UNTIL REPAIRS MADE.
Condition: Unknown
Due 20 September 2000
Resolved 20 September 2000
Engineering
Issued 20 September 2000
Resolved
MAKE BREPAIRS TO FIRE DAMAGED AREA AROUND PORT ENGINE, ie; EXHAUST LAGGING AND TURBO COVERS.
Condition: Unknown
Due 20 September 2000
Resolved 20 September 2000
Construction/Loadline
Issued 2 July 1999
Resolved
MAKE PERMENANT REPAIRS TO STBD INBOAD STRUT ASSEMBLY BY CROPPING OUT OLD STRUT UP THRU HULL AND INSTALLING NEW (ALL ONE PIECE) STRUT AS ORIGINAL. 4 NEW CUMMINGS REPLACED OLD DETROITS APPROX 3 YRS AGO ADDING 1000 H.P. DOES NEW STRUT & PRESENT ONES REQUIRE MODIFICATION TO STRENGTH MEMBERS?
Condition: Unknown
Due 2 July 1999
Resolved 2 July 1999