Records from 1981 to 1999. Most recent: inspection, 27 June 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 62
27 June 1999
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1078531
3 November 1998
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 148932
14 July 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1128498
17 June 1998
Re-Inspection · Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1409914
26 May 1998
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1462664
22 September 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 776302
25 August 1997
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 159319
26 April 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1104141
22 April 1997
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1421311
12 August 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1086682
11 June 1996
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1430221
13 May 1996
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446339
18 April 1996
Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1446327
8 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1185495
7 December 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1184862
27 October 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 26187
17 July 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1183854
13 June 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1187219
6 June 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 150917
28 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 182934
26 April 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1436978
29 March 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 845183
25 August 1994
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 866857
25 May 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1407326
13 April 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1167722
23 March 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 855860
9 February 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1165479
30 August 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 650095
16 August 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1151838
11 August 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 846579
11 August 1993
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 847484
19 July 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 848330
16 July 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 847910
7 July 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1152327
23 June 1993
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 842994
10 June 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 834386
5 May 1993
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415831
29 April 1993
Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1415832
12 December 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 147746
7 October 1992
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1258562
8 September 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 49036
26 June 1992
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1267425
3 June 1992
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1267558
17 May 1991
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 912045
2 May 1991
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1213602
27 September 1990
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 915568
2 June 1988
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1199588
31 January 1986
Credit Drydock
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1305178
22 April 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1290035
26 February 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 974436
8 January 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 977027
23 March 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 973409
17 January 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971666
4 January 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1280605
4 January 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1283338
19 December 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971241
16 September 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1274330
2 September 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 965096
2 March 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 963331
17 December 1982
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 964471
16 December 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965702
28 December 1981
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1277221
Electrical
Issued 17 June 1998
Resolved
PROVIDE AND E-LIGHT TO ILLUMINATE THE MAIN DECK ACCOMODATIONS SPACE STAIR TOWER.
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Fire Fighting
Issued 17 June 1998
Resolved
RETEST/RECERTIFY VIA 3RD PARTY, FIXED FIRE-FIGHTING HALON SYSTEM IN ENGINE ROOM. PAYING PARTICULAR ATTENTION TO REPLACEMENT ITEMS (CONTROL VALVE) TO ER #2 SYSTEM.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Engineering
Issued 17 June 1998
Resolved
STENCIL FUEL TRANSFER HOSE WITH MAWP AND WITH F.O. SERVICE MARKED ON IT.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Lifesaving
Issued 17 June 1998
Resolved
PROVE PROPER OPERATION OF GENERAL ALARM IN SHALE SHAKER HOUSE, DRILL FLOOR,LEGS WELLS, AND BELOW MAIN DECK.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Construction/Loadline
Issued 17 June 1998
Resolved
PROVIDE MISSING SELF-CLOSING DEVICE FOR STAIRTOWER DOOR LEADING TO JACKING HOUSE.
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Fire Fighting
Issued 17 June 1998
Resolved
REPLACE MISSING APPLICATOR CHAIN FOR F/F STAION #2.
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Fire Fighting
Issued 17 June 1998
Resolved
PROVIDE BATTERY FOR PORTABLE SMOKE DETECTOR IN PASSAGEWAY, MAIN DECK. EXISITING BATTERY FOUND INOPERABLE.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Electrical
Issued 17 June 1998
Resolved
MARK "E" FOR EMERGENCY LIGHTING IN ACCOMODATIONS STAIRTOWER.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Navigation
Issued 17 June 1998
Resolved
PROVE OPERATION OF BLUE HELO PERIMETER LIGHTING.
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Lifesaving
Issued 17 June 1998
Resolved
PROVIDE INTERIOR LIGHTING FOR LIFEBOATS #1 AND 2.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Electrical
Issued 17 June 1998
Resolved
PROVE PROPER OPERATION OF ACCOMODATION STAIRTOWER E-LIGHT.
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Lifesaving
Issued 17 June 1998
Resolved
MARK " WORK VEST ONLY" ON WORK VEST BOX ON THE MAIN DECK, STARBORD SIDE.
Condition: Unknown
Due 3 August 1998
Resolved 3 August 1998
Electrical
Issued 17 June 1998
Resolved
REMOVE ALL OVERHEAD PLASTIC TIES WRAPS AND REPLACE WITH IEEE STD-45 RECOMMENDED STEEL BAND WRAPS ON THE DRILL FLOOR.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Electrical
Issued 17 June 1998
Resolved
REPAIR ALL SPRING LOADED SELF CLOSING OUTLET CAPS IN THE MUD PIT ROOM AND ON THE DRILLING FLOOR.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Electrical
Issued 17 June 1998
Resolved
RENEW AS ORIGINAL ALL FRAYED ARMOR CABLE THROUGH SHALE SHAKER/MUD PIT HAZARDOUS LOCATIONS.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Accommodation/Occupational Safety
Issued 17 June 1998
Resolved
PROVIDE RACK LIGHT FOR MIDDLE TOP RACK IN STATE ROOM 01-103; NO RACK LIGHT PROVIDED.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Documentation
Issued 17 June 1998
Resolved
HAVE RIG MANAGER/OIM SIGN MUSTER LISTS THROUGHOUT RIG.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Accommodation/Occupational Safety
Issued 17 June 1998
Resolved
PROVIDE 3 LOCKERS FOR STATEROOM 01-103 TO PROVIDE A TOTAL OF ONE PER EACH PERSON ROOM IS ELIGIBLE TO HOLD.
Condition: Unknown
Due 4 August 1998
Resolved 4 August 1998
Construction/Loadline
Issued 22 April 1997
Resolved
PROVE PROPER OPERATION OF UPPER AND LOWER DOORS TO ACCOMODATION STAIRWELL AND ENSURE BOTH LATCH CLOSED.
Condition: Unknown
Due 22 May 1997
Resolved 1 May 1997
Fire Fighting
Issued 22 April 1997
Resolved
VERIFY FIRE DAMPERS IN EMD AND MUD PUMP ROOMS (4 DAMPERS) AND UPDATE FIRE PLAN. ENSURE ALL FOUR DAMPERS OPERATE PROPERLY.
Condition: Unknown
Due 22 May 1997
Resolved 1 May 1997
Lifesaving
Issued 11 June 1996
Resolved
Repair broken seat/cover on aft engine compartment and clean/lube aft limitswitch and replace limit switch arm on lifeboat no. 2.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Lifesaving
Issued 11 June 1996
Resolved
Replace missing jacknife in lifeboat no. 1.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Fire Fighting
Issued 11 June 1996
Resolved
Repair relief valve on discharge side of auxiliary fire pump (mud pump room). Label on valve shows 125 psi set pressure; during shutoff test, pressure climbed past 200 psi.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Fire Fighting
Issued 11 June 1996
Resolved
Fabricate and mount placards for Halon systems in engine rooms 1 and 2, SCRroom, and mud pump rooms that direct personnel to location of Halon cylinder stowage in case of failure of system to activate from remote activation station.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Lifesaving
Issued 11 June 1996
Resolved
Rewire mud pit room loss-of-ventilation alarm so that it is wired independently from ventilation fan motors or controllers.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Fire Fighting
Issued 11 June 1996
Resolved
Renew or submit for hydrostatic testing the nitrogen cylinders form remote Halon activation stations; mud pump room (2 of 2), SCR room (1 of 1), engine room no. 1 (1 of 2).
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Accommodation/Occupational Safety
Issued 11 June 1996
Resolved
Repair one broken and one wasted support tube on starboard netting around helo deck. Replace any bad netting (chain link fencing) around helo deck.
Condition: Unknown
Due 11 June 1996
Resolved 11 June 1996
Construction/Loadline
Issued 18 April 1996
Resolved
CONDUCT SWIMBY OF BOTTOM OF MAT FOR SPECIAL EXAM IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Construction/Loadline
Issued 18 April 1996
Resolved
CONDUCT TOPSIDE PORTION OF SPECIAL EXAM IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 18 April 1996
Resolved 18 April 1996
Fire Fighting
Issued 26 April 1995
Resolved
SUBMIT REVISED FIRE CONTROL PLAN, WITH SUMMARY OF CHANGES, TO [name withheld] FOR APPROVAL.
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Accommodation/Occupational Safety
Issued 25 May 1994
Resolved
CONDUCT INTERNAL EXAM OF THE FOLLOWING AIR RECEIVERS:_x001C_ 1. DRILL FLOOR AIR _x001C_ 2. RIG AIR_x001C_ _x001C_
Condition: Unknown
Due 25 May 1994
Resolved 25 May 1994
Construction/Loadline
Issued 16 July 1993
Resolved
REPLACE 6" CHECK VALVE FOR BARITE OVERBOARD DUE TO ERRODED SEAT.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Accommodation/Occupational Safety
Issued 16 July 1993
Resolved
INSTALL RELIEF VALVE SET AT OR BELOW MAWP (150 PSI) FOR DRILL FLOOR AIR RECEIVER. ENSURE RELIEF VALVE IS EQUIPPED WITH HAND RELIEVING DEVICE.
Condition: Unknown
Due 16 July 1993
Resolved 16 July 1993
Documentation
Issued 5 May 1993
Resolved
SUBMIT COPIES OF DIVER'S REPORT AND VIDEOTAPES OF ALL PHASES OF UNDERWATER EXAMINATION TO (USCG)MSO NEW ORLEANS, LOUISIANA.
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Construction/Loadline
Issued 5 May 1993
Resolved
COMPLETE UNDERWATER SURVEY OF MAT UNDERSIDE AND SKIRT IN PRESCENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 5 May 1993
Resolved 5 May 1993
Accommodation/Occupational Safety
Issued 29 April 1993
Resolved
REPLACE POTABLE WATER AND SANITARY WATER TANK RELIEF VALVES WITH VALVES RATED < 100PSI AND EQUPPED WITH HAND RELIEFS, OR MAKE AVAILABLE FOR INTERNAL INSPECTION.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Construction/Loadline
Issued 29 April 1993
Resolved
READJUST AND PROVE PROPER SEALING OF WTD IN SACK ROOM.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Construction/Loadline
Issued 29 April 1993
Resolved
REPAIR AND PROVE OPERATION OF MISADJUSTED/STICKING WTD OPEN/CLOSE INDICATORMICROSWITCHES.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Documentation
Issued 29 April 1993
Resolved
SUBMIT HAZARDOUS LOCATION PLAN TO COGNIZANT OCMI FOR APPROVAL.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Accommodation/Occupational Safety
Issued 29 April 1993
Resolved
INSTALL VENT CLOSURES ON TWO (2) VENTS AT QUARTERS ON STBD SIDE AT LEFT SIDE OF ENTRY TO MACHINERY SPACE.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Navigation
Issued 29 April 1993
Resolved
LEVEL AND CLEAN LENSE ON OBSTRUCTION LIGHT PORT AFT CORNER.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Construction/Loadline
Issued 29 April 1993
Resolved
MAKE VESSEL AVAILABLE FOR UNDERWATER SURVEY OF MAT AND MAT TO LEG CONNECTIONS.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Accommodation/Occupational Safety
Issued 29 April 1993
Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION THE DRILL FLOOR AIR RECEIVER, RIG AIR RECEIVER, AND TEST RELIEF VALVES ON BOTH.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Engineering
Issued 29 April 1993
Resolved
REMOVE BRASS PETCOCKS FROM #1 GENSET F/O FILTER (RACOR) OR REPLACE WITH STEEL VALVES.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Electrical
Issued 29 April 1993
Resolved
REMOVE "SO" TYPE ELECTRICAL CABLE FROM THIRD PARTY EQUIPMENT IN MUD PIT ROOM AND DRILL FLOOR/SHAKER AREA.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Construction/Loadline
Issued 29 April 1993
Resolved
PROVIDE MORE POSITIVE DOOR CLOSURE ACTION ON MUD PIT ROOM DOORS.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Deck/Cargo
Issued 29 April 1993
Resolved
LABEL CRANE REFUELING STATIONS AND INSTALL "NO SMOKING" SIGNS.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Construction/Loadline
Issued 29 April 1993
Resolved
MAKE MUD DUMP VALVES AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Fire Fighting
Issued 29 April 1993
Resolved
REPAIR GENERAL ALARM BELLS AND/OR ROTATING LIGHTS IN FOLLOWING AREAS: STBD AFT STOREROOM,MUDPUMP ROOM (AFT), HYDRAULIC PUMP ROOM & LIGHT, STBD LEG JACKHOUSE, SHAKER AREA, DRILL FLOOR & LIGHT, AND BESIDE EMERGENCY GENERATORDOOR.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Electrical
Issued 29 April 1993
Resolved
REPAIR MUD PIT VENT ALARM BLUE LIGHT PORT SIDE MAIN DECK.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Accommodation/Occupational Safety
Issued 29 April 1993
Resolved
MOVE MUD ENGINEER'S TESTING TABLE AND APPLIANCES OUTSIDE HAZARDOUS LOCATIONAREA.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Electrical
Issued 29 April 1993
Resolved
PROVIDE LOSS OF AIR PURGE ALARM/INDICATOR ON MUD FLOW/PIT LEVEL CONSOLE AT DRILLER'S CONSOLE.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Accommodation/Occupational Safety
Issued 29 April 1993
Resolved
REPLACE HOT WATER HEATER TEMP/PRESS RELIEF VALVES WITH PROPERLY RATED ONES (210DEG/100PSI).
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Engineering
Issued 29 April 1993
Resolved
RENEW F/O HOSES ON #2,3, & 4 GENSETS WITH HOSES IAW 46 CFR 56.60-25(c).
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Electrical
Issued 29 April 1993
Resolved
REPLACE EMERGENCY LIGHTING IN GENERATOR ROOM #1.
Condition: Unknown
Due 11 May 1993
Resolved 11 May 1993
Engineering
Issued 3 June 1992
Resolved
TEST ALL MAIN GENERATOR OVERSPEED TRIPS.
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Accommodation/Occupational Safety
Issued 3 June 1992
Resolved
TEST PRESSURE RELIEF VALVES ON THE TWO HIGH PRESSURE AIR RECIEVERS AND ON ALL SIX DRY BULK TANKS.
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Lifesaving
Issued 3 June 1992
Resolved
PROVDE OXYGEN AND LEL METER FOR #1 FIREMANS OUTFIT.
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Electrical
Issued 3 June 1992
Resolved
TEST FOR PROPER OPERATION REMOTE SHUTDOWNS FOR VENTILATION AND ALL MAIN GENERATOR SHUTDOWNS.
Condition: Unknown
Due 12 August 1992
Resolved 12 August 1992
Unknown
Issued 2 May 1991
Resolved
SUBMIT OPERATION MANUAL AND CONSTRUCTION PORTFOLIO FOR COAST GUARD APPROVAL_x001C_
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Unknown
Issued 2 May 1991
Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL SHUTDOWN FOR ALL S/S GENERATORS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Unknown
Issued 2 May 1991
Resolved
PROVE PROPER OPERATION OF ALL NECESSARY TESTS AND SHUTDOWNS ON EMERGENCY GENERATOR.
Condition: Unknown
Due 2 May 1991
Resolved 2 May 1991
Electrical
Issued 2 June 1988
Resolved
#2 GENERATOR NOT TO BE RUN UNTIL PROPER OPERATION OF LOW LUBE OIL SHUTDOWN AND DEMOMSTRATION WITH RIG SHUTDOWN IS CODUCTED.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Electrical
Issued 2 June 1988
Resolved
DEMONSTRATE PROPER OPERATION OF LOSS OF VENTILATION ALARM TO THE MUD PITS PRIOR TO DRILLING OPERATIONS.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Unknown
Issued 2 June 1988
Resolved
MAKE THE LEG-TO-MAT CONNECTIONS AVAILABLE FOR VISUAL INSPECTION OR UNDERWATER VIDEO TO RE-EVALUATE CRACKS DISCOVERED IN ALL TAPERED LEG RACK EXTENSIONS.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Unknown
Issued 2 June 1988
Resolved
INSTALL OILY WATER SEPARATOR FOR THE BILGE SYSTEM. ALL BILGE SLOPS TO BE RETAINED ON BOARD.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Lifesaving
Issued 2 June 1988
Resolved
PROVIDE APPROVED FISHING KITS FOR #1 AND #2 LIFEBOATS.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Electrical
Issued 2 June 1988
Resolved
PROPERLY AFFIX LIGHT COVERS FOR LIFEBOAT EMBARKATION LIGHTS (2) ON THE PORT SIDE.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Electrical
Issued 2 June 1988
Resolved
INSTALL LOSS OF VENTILATION ALARM TO THE MUD PITS AT THE DRILLERS CONSOLE ON THE RIG FLOOR.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Electrical
Issued 2 June 1988
Resolved
SHAKER UNIT ELECTRICAL INSTALLATION TO BE EXAMINED PRIOR TO DRILLING OPERATIONS.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Unknown
Issued 2 June 1988
Resolved
CONDUCT SPECIAL UNDER WATER EXAM IN LIEU OF DRYDOCKING.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Lifesaving
Issued 2 June 1988
Resolved
PROVIDE AN APPROVED FIRST AID KIT FOR THE HOSPITAL SPACE.
Condition: Unknown
Due 2 June 1988
Resolved 2 June 1988
Construction/Loadline
Issued 31 January 1986
Resolved
MAKE PERMANENT REPAIRS TO THE VERTICAL STIFFENER AND ASSOCIATED BRACKETS IN BALLAST TANK B-9 LOCATED AT THE FORWARD PORT CORNER OF THE VESSEL.
Condition: Unknown
Due 31 January 1986
Resolved 31 January 1986
Deck/Cargo
Issued 31 January 1986
Resolved
REPLACE THE MISSING SWITCH ON THE ANCHOR WINCH.
Condition: Unknown
Due 31 January 1986
Resolved 31 January 1986
Electrical
Issued 8 January 1985
Resolved
REINSTALL HANDRAILS ON THE FRONT OF THE MAIN GENERATOR SWITCHBOARD.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Electrical
Issued 8 January 1985
Resolved
REPAIR THE BROKEN LIGHT LENSES (18) LOCATED THROUGHOUT THE RIG.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Unknown
Issued 8 January 1985
Resolved
REPAIR THE AIR PURGE SYSTEM FOR THE EMERGENCY SHUTDOWN PANEL ON THE DRILL FLOOR.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Electrical
Issued 8 January 1985
Resolved
PROVIDE AN APPROVED ELECTRICAL CONNECTION FOR THE PUBLIC ADDRESS SPEAKER IN THE MUD PIT ROOM.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Navigation
Issued 8 January 1985
Resolved
MAKE BOTH SIDE LIGHTS OPERABLE PRIOR TO ANY RIG MOVEMENT.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Electrical
Issued 8 January 1985
Resolved
MAKE THE GENERAL ALARM BELL ON THE PORT AFTER CORNER OF THE LIVING QUARTERSAND THE BELL ON THE FIRST LEVEL OF THE QUARTERS OPERABLE.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Lifesaving
Issued 8 January 1985
Resolved
RELABEL BOTH LIFEBOATS WITH THE CORRECT NUMBER, CAPACITY AND HOMEPORT.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Lifesaving
Issued 8 January 1985
Resolved
PROVIDE IN DATE ORANGE SMOKES (2), HAND-HELD RED FLARES (12), AND PARACHUTERED FLARES (12) FOR LIFEBOAT NUMBER ONE.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Lifesaving
Issued 8 January 1985
Resolved
PROVIDE A COAST GUARD APPROVED FISHING KIT FOR LIFEBOAT NUMBER ONE.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Lifesaving
Issued 8 January 1985
Resolved
CHANGE THE FUEL IN LIFEBOAT NUMBER ONE.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Lifesaving
Issued 8 January 1985
Resolved
REPLACE THE TWO LIFERINGS ON THE AFTER CORNERS.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Documentation
Issued 8 January 1985
Resolved
PUT THREE MORE QUALIFIED LIFEBOATMEN ON BOARD THE VESSEL.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Lifesaving
Issued 8 January 1985
Resolved
PROVIDE 500' AUXILIARY LINE OF 3 INCH MANILLA OR EQUIVALENT FOR THE LINE THROWING GUN.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Fire Fighting
Issued 8 January 1985
Resolved
PROVIDE ONE ADDITIONAL 50 FOOT FIRE HOSE.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Navigation
Issued 8 January 1985
Resolved
CLEAN THE PORT SIDE LIGHT AND REPAINT BOTH SIDE LIGHT SCREENS FLAT BLACK PRIOR TO ANY RIG MOVEMENT.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Deck/Cargo
Issued 8 January 1985
Resolved
REPAIR OR REPLACE THE INOPERABLE RELIEF VALVE ON THE AIR RECEIVER UNDER THEDRILL FLOOR.
Condition: Unknown
Due 8 January 1985
Resolved 8 January 1985
Lifesaving
Issued 23 March 1984
Resolved
REPAIR OR REPLACE PORT LIFE CAPSULE, PORT DAVIT LIMIT SWITCH AND CATWALK. MAKE AVAILABLE FOR COAST GUARD INSPECTION UPON COMPLETION.
Condition: Unknown
Due 23 March 1984
Resolved 23 March 1984
Unknown
Issued 23 March 1984
Resolved
THE FOLLOWING DEFICIENCY IS FOR THE [name withheld], DN643745.
Condition: Unknown
Due 23 March 1984
Resolved 23 March 1984
Unknown
Issued 4 January 1984
Resolved
CONDUCT A FIRE AND BOAT DRILL IN THE PRESENCE OF A COAST GUARD INSPECTOR PRIOR TO DEPARTING PORT.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Unknown
Issued 4 January 1984
Resolved
THE FOLLOWING DEFICIENCY IS FOR THE [name withheld], DN643745.
Condition: Unknown
Due 4 January 1984
Resolved 4 January 1984
Accommodation/Occupational Safety
Issued 16 December 1982
Resolved
REPLACE RELIEF VALVE ON DRILL FLOOR AIR RECIEVER, MAXIMUM 150 PSI WITH HANDRELIEVING GEAR.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Documentation
Issued 16 December 1982
Resolved
PROVIDE PERMANENT STABILITY LETTER AND LOADLINE ON BOARD.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Lifesaving
Issued 16 December 1982
Resolved
PROVIDE 500 FT. AUXILIARY LINE FOR LINE THROWING GUN.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Electrical
Issued 16 December 1982
Resolved
PROPERLY INSTALL LIGHTING SYSTEM IN MECHANICS SHOP.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Electrical
Issued 16 December 1982
Resolved
MOUNT JUNCTION BOX AT HATCH IN SACK ROOM AND PROPERLY SUSPEND WIRING.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Electrical
Issued 16 December 1982
Resolved
REWIRE OR PROPERLY SPLICE CABLE ABOVE SANITARY WATER TANK.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Construction/Loadline
Issued 16 December 1982
Resolved
REPAIR SELF CLOSURES TO MUD PIT DOORS FOR PROPER OPERATION.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Fire Fighting
Issued 16 December 1982
Resolved
REPAIR THE FOLLOWING GENERAL ALARM BELLS: SACK ROOM, MUD JACKING PUMP ROOMAND FLASHING LIGHT IN PUMP ROOM.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Fire Fighting
Issued 16 December 1982
Resolved
PROVIDE ENCLOSURE SECURITY BOXES AROUND ALL GENERAL ALARM CONTACT MAKERS EXCEPT TOOLPUSHERS OFFICE.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Construction/Loadline
Issued 16 December 1982
Resolved
REPLACE CONTACT ARMS FOR ALL WATERTIGHT DOOR ALARM SWITCHES.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Lifesaving
Issued 16 December 1982
Resolved
PROVIDE 4 PARACHUTE FLARES.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Fire Fighting
Issued 16 December 1982
Resolved
REPAIR OR REPLACE OXYGEN INDICATOR S/N C-0182.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Documentation
Issued 16 December 1982
Resolved
SUBMIT CONSTRUCTION PORTFOLIO TO [name withheld] DISTRICT (MMT) FOR APPROVAL.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Documentation
Issued 16 December 1982
Resolved
SUBMIT HAZARDOUS LOCATIONS PLAN TO [name withheld], FOR APPROVAL.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Documentation
Issued 16 December 1982
Resolved
PROVIDE 2 ADDITIONAL CERTIFICATED LIFEBOATMEN PER HITCH OR ASSIGN ALL PERSONNEL TO 1 BOAT FOR ABANDON RIG STATIONS.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Accommodation/Occupational Safety
Issued 16 December 1982
Resolved
REPAIR QUARTERS AIR CONDITIONER SHUT DOWN.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Accommodation/Occupational Safety
Issued 16 December 1982
Resolved
RELOCATE PURGE AIR INDICATOR OUTSIDE DRILLERS CONSOLE.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Accommodation/Occupational Safety
Issued 16 December 1982
Resolved
REPAIR PURGE AIR SYSTEM TO GENERAL ALARM SWITCH AND SENSOR INTERFACE ON DRILL FLOOR.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Electrical
Issued 16 December 1982
Resolved
REPAIR ALL EMERGENCY LIGHTS AS REQUIRED THROUGHT RIG.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Fire Fighting
Issued 16 December 1982
Resolved
PROPERLY MARK ALL GENERAL ALARM BELLS AND FLASHING LIGHTS.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Lifesaving
Issued 16 December 1982
Resolved
PROVIDE LIGHTS AND WHISTLES ON ALL PFD'S NOT EQUIPPED WITH SAME.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Fire Fighting
Issued 16 December 1982
Resolved
MARK ALL PORTABLE FIRE EXTINGUISHER STATIONS TO CORRESPOND TO EXTINGUISHER NUMBERS.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Lifesaving
Issued 16 December 1982
Resolved
REPAIR LIMIT SWITCHES ON #1 LIFEBOAT.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Lifesaving
Issued 16 December 1982
Resolved
REPLACE RING LIFE BUOY AT PORT SIDE FUELING STATION.
Condition: Unknown
Due 16 December 1982
Resolved 16 December 1982
Documentation
Issued 28 December 1981
Resolved
PROVIDE ON BOARD THE VESSEL AN APPROVED CONSTRUCTION PORTFOLIO PRIOR TO 1 MAY 1982.
Condition: Unknown
Due 1 May 1982
Resolved 28 December 1981
Electrical
Issued 28 December 1981
Resolved
EFFECT PERMANENT REPAIRS TO INOPERATIVE REMOTE SHUTDOWNS FOR THE QUARTER'S AIR CONDITIONING SYSTEM PRIOR TO 15 JANUARY 1982.
Condition: Unknown
Due 31 January 1982
Resolved 28 December 1981