MAURY USCG vessel records Sign in
← All vessels

FREEDOM

FREEDOM is a 1981 passenger vessel (inspected). The Coast Guard has recorded 64 inspections since 1985, most recently in December 2025, along with 63 deficiencies and 3 casualty investigations between 2003 and 2011.

Records from 1985 to 2025. Most recent: inspection, 16 December 2025.

Built
1981
Last inspected
16 December 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ3526
Flag
UNITED STATES
368417620
Maury page id
psix-53058

Inspections, by type

…with no type recorded6
Years with a record 38 calendar years (1985–2025)
The 64 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)92.2 ft × 43.5 ft × 9.0 ft
Registered tonnagegross 98 / net 80
ITC dimensions (L × B × D)92.2 ft × 43.5 ft × 9.0 ft
ITC tonnagegross 313 / net 155
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1981
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPHILADELPHIA, PA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 May 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
313 - Convention (Subpart B), Gross Ton
46 - Dead Weight, Gross Ton
230 - Displacement, Gross Ton
80 - Regulatory (Subpart C or D), Net Ton
155 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ3526MMSI 368417620 · active · compulsorily equipped · granted 6 May 2025, expires 6 May 2035
WDH9715MMSI 367670870 · cancelled · compulsorily equipped · granted 7 May 2015, cancelled 5 May 2025
WDG8387MMSI 366883710 · cancelled · compulsorily equipped · granted 30 May 2013, cancelled 18 April 2023
WDG7901MMSI 367571980 · expired · compulsorily equipped · granted 25 April 2013, cancelled 15 July 2023
WDB3128MMSI 366883710 · expired · compulsorily equipped · granted 4 March 2003, cancelled 4 May 2013
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 64

16 December 2025 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8284419
27 May 2025 Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8141298
21 August 2024 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7932752
22 May 2024 MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7916922
5 July 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7733408
14 June 2023 Deficiency Check · Annual Inspection · MTSA Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7712908
8 June 2022 MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7472064
4 April 2022 Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7423983
26 May 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7207553
18 June 2020 Deficiency Check · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6977068
14 May 2019 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6683389
9 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6505927
15 May 2018 Administrative Inspection · MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6407890
23 March 2018 Internal Structural Exam · Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6377466
8 May 2017 DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6136947
18 May 2016 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5880129
4 June 2014 MTSA Verification · DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4879504
27 January 2012 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4232823
1 December 2011 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4199597
5 July 2011 Deficiency Check · Damage Survey
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4070035
5 July 2011 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 4070170
22 April 2009 MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3458019
23 April 2008 MTSA Verification · COI Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3189215
23 April 2008 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3191281
24 April 2007 Annual Inspection · MTSA/ISPS Verification
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2914287
13 July 2006 In-Service Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2711723
27 June 2006 MTSA Verification · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 2692733
11 April 2005 MTSA Verification · Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2330953
28 October 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2230293
18 October 2004 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2222996
28 April 2004 Annual Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 2059778
29 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1978089
1 October 2003 In-Service Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1947187
26 March 2003 COI Inspection · In-Service Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1763405
18 March 2003 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1760758
30 January 2003 Inclining Experiment · Hull Examination · COI Inspection · Construction Oversight
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1737468
30 May 2002 Construction Oversight · Hull Examination · Internal Structural Exam
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1622649
28 June 2001 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1461428
31 July 2000 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1439089
27 June 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1077601
17 September 1998 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 800100
4 May 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 792296
5 May 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1098050
30 October 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 862892
9 May 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1082896
12 May 1995 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186244
13 May 1994 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1320961
2 July 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 850946
18 June 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 847608
23 March 1993 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 837832
7 April 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1269773
10 December 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 961602
25 March 1991 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 900719
2 April 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 928087
12 July 1989 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031068
4 April 1989 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1340593
8 June 1988 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1206206
28 March 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1342446
7 December 1987 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1308530
30 March 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1328448
27 October 1986 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1329184
12 September 1986 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1003713
17 April 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1303814
17 April 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 983950

Deficiency record · 63

01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 December 2025 Resolved
A Certificate of Inspection may be suspended and withdrawn or revoked by the cognizant OCMI at any time for noncompliance with the requirements of this subchapter. Eight (08) deficiencies remain outstanding from the 05/28/2025 Annual Inspection. These deficiencies are significantly passed due and the vessel is considered not in compliance with the terms and conditions of its Certificate of Inspection. The vessel may not operate in the carriage of passengers until all outstanding requirements are addressed satisfactorily. CITE: 46 CFR 176.107(c)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2026
Resolution: Cleared deficiencies
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 27 May 2025 Resolved
Each vessel must be provided with a visual and audible alarm at the operating station to indicate a high water level. Aft Compartment Bilge Alarm Doesn't Sound in the Fwd Pilothouse. Repair fwd pilothouse bilge alarm for aft compartment. 46 CFR §119.530
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2025
Resolved 13 April 2026
Resolution: Fixed alarm
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 27 May 2025 Resolved
Each hand portable fire extinguisher should be inspected for excessive corrosion and general condition. Fire Extinguisher in ER is out of svc, currently ordered for replacement by Fire Extinguishing Svc. Provide receipt of new extinguisher's delivery. 46 CFR §115.810(a)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 13 April 2026
Resolution: Extinguisher was serviced
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 May 2025 Resolved
A Certificate of Documentation is req'd for vsl operations in certain trades .... The vsl's COD is in process of updating owner/operator. Provide evidence of new, valid COD's receipt. 46 CFR §67.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 June 2025
Resolved 28 June 2026
Resolution: Vsl received new COD.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2025 Resolved
All electrical equipment and circuits must be clearly marked and identified. Circuit labels inside the breaker boxes is almost illegible. Re-label circuits inside breaker boxes. 46 CFR §120.220(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 13 April 2026
Resolution: Circuits relabeled.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 27 May 2025 Resolved
Draft stops must be fitted ... at each deck level in the vertical direction. Fire dampers for ER ventilation can only be operated during dischg of CO2 or during servicing & could not be exercised during inspection. Provide copy of tech report noting that the 'tween deck fire dampers were tested.46 CFR §116.415(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 June 2025
Resolved 21 April 2026
Resolution: Received tech report and view video of dampers closing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 27 May 2025 Resolved
Connections must be made to battery terminals with permanent type connectors. Spring clips or other temporary type clamps are prohibited, incl wing nuts. Wing nuts are in use on the battery terminal lugs. Replace w/ hex nuts.46 CFR §120.350(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 13 April 2026
Resolution: Replaced with hex nuts
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 27 May 2025 Resolved
Electrical equipment exposed to the weather must be watertight. The GFI outlet housing on the upper deck, aft, stbd side is broken & not weather tight. Replace receptacle box. 46 CFR §120.210(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 13 April 2026
Resolution: Receptacles boxes replaced
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 27 May 2025 Resolved
Each lighting fixture globe, lens, or diffuser must have a guard or be made of high strength material .... Two light glob guards are missing from fixtures on the upper deck, stbd side. Replace both missing globe guards.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 June 2025
Resolved 13 April 2026
Resolution: Globe guards added
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 May 2024 Resolved
Each life ring must be marked with Type II retroreflective material. Apply retro to all life rings on vessel. 46 CFR 122.604(i)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 June 2024
Resolved 5 June 2024
Resolution: Retro placed on all ring buoys.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 22 May 2024 Resolved
Vessel must have on board the original Certificate of Documentation currently in effect. COD expired on 31Jan2024. Provide COD with new ownership when recieved. 46 CFR 67.313(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 June 2024
Resolved 18 September 2024
Resolution: COD being processed through NVDC
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2023 Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels...Vsl's Hire Rite Certificate of Enrollment was expired. Provide picture of valid Certificate of Enrollment and proof that vessel's masters and crew members are in full compliance with drug testing requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 26 June 2023
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 June 2023 Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected... Multiple buttons on the fire detection panel were nonoperational. Provide a plan to mitigate any associated risks with the current state of the fire detection panel. Provide service report once fire detection panel is fully operational.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 5 July 2023
Resolution: Received service report from Keystone fire attesting to the operation of the fire alarm panel.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 8 June 2022 Resolved
A vessel must comply with the applicable requirements for any radio installation. VHF radios had MMSI numbers which did not match the FCC Station License or each other.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 14 June 2023
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 8 June 2022 Resolved
The Vessel Security Officer must maintain a TWIC. VSO's TWIC was expired, provide proof of either application to renew or valid TWIC.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 14 June 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 May 2021 Resolved
Employers shall establish programs for the chemical testing for dangerous drugs on a random basis. There was no record of what crew members were enrolled in a random testing program.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2021
Resolution: Operator submitted roster of enrolled members.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 26 May 2021 Resolved
Fire pump seal is leaking which creates an accumulation of bilge water that requires proper disposal under 33 CFR. Repair or renew fire pump seal.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 23 June 2021
Resolution: Operator submitted video of fire pump operating with no leak at pump. Video included water being sprayed through on deck hoses.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 May 2021 Resolved
Each connection to a conductor must be made in an enclosure. Bilge high level alarm connections are not in enclosures. Enclose connections; twist on connections (if used) must be secured to prevent loosening.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
Resolution: Operator submitted proof, in the form of photographs, of the bilge high level alarm connections being placed in enclosures.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 May 2021 Resolved
An audible and visual alarm is required during occurrence of a low oil level in any oil reservoir of a hydraulic, power-operated steering-gear system. Provide procedures to test this alarm and test to the satisfaction of the attending marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 9 June 2021
Resolution: Operator submitted video proof of actuating of steering low level alarm via float switch.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 May 2021 Resolved
Aft peak bilge valve was unable to be actuated. Corrected prior to the end of the inspecting by using hand tools.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 May 2021
Resolution: Corrected prior to end of inspection with hand tools.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 18 June 2020 Resolved
During a test of the fixed gas extinguishing (CO2) system, the installed 30 second time delay did not discharge until 39 seconds had elapsed. Prove operation of 30 second time delay with a tolerance of +20/-0 seconds.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 October 2020
Resolution: Time delay was replaced and tested satisfactory in presence of marine inspector.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 June 2020 Resolved
Vessel electrical shore tie was observed to have multiple points of damage repaired by electrical tape. Provide new in kind shore tie cable and fit with chaffing gear to prevent damage.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 2 October 2020
Resolution: Electrical shore tie was cut back to eliminate damaged portions.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 May 2019 Resolved
The Vessel Security Officer or the Company Security Officer must ensure an audit of the VSP is conducted annually. The personnel conducting the audit must not have regularly assigned security duties and be independent of the security measures being audited. Conduct audit by 31 Jul 2019.
Action required: 705 - Other - as specified
Due 31 July 2019
Resolved 17 July 2019
Resolution: Vessel completed required annual Security Audit.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 May 2019 Resolved
Replace aft life ring buoy on main deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 June 2019
Resolved 28 August 2019
Resolution: Vessel purchased a new life ring and replaced the old one.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 9 August 2018 Resolved
Vsl is broadcasting: Invalid MMSI, invalid Call Sign, no static draft information, and not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 September 2018
Resolved 14 May 2019
Resolution: Verified that the AIS was broadcasting correctly during the annual inspection.
Fire Fighting › Structural - Horizontal Zones › General
Issued 8 May 2017 Resolved
For each fire door onboard provide class A/B and fire rating
Condition: Improper/Lack of Maintenance
Due 22 May 2017
Resolved 19 May 2017
Fire Fighting › Means of Escape › Doorways
Issued 8 May 2017 Resolved
Resubmit fire control plan for review to evaluate/update the following: areas of safe refuge, passenger count, types of boundaries and class of spaces.
Condition: Improper/Lack of Maintenance
Due 22 May 2017
Resolved 19 May 2017
Engineering › Steering Gear System › Valve
Issued 8 May 2017 Resolved
There is a hydraulic leak on aft steering hydraulic piping. Repair piping to satisfaction of USCG Marine Inspector
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 19 May 2017
Engineering › Fuel Oil Service System › Tank
Issued 18 May 2016 Resolved
Remove Vinyl sight glass on both fuel tanks.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 May 2016
Resolution: Tubing was removed and valve mechanically plugged while onboard.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 May 2016 Resolved
Fire doors do not close in the proper order and do not latch. Doors must close in a specific order for the jamb to fully seal. Doors close in opposite order.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 1 June 2016
Resolution: Doors were serviced by fire company and now properly close.
Documentation › Certificates/Documents › FCC SSL
Issued 18 May 2016 Resolved
Provide valid FCC Certificates.
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 1 June 2016
Resolution: Vessel has all current and required certs onboard.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 May 2016 Resolved
First aid kit is missing ammonia inhalant and asprin is expired.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 1 June 2016
Resolution: All required items are present.
Lifesaving › Lifebuoys › Serviceable
Issued 18 May 2016 Resolved
Both upper deck life rings need replaced. Heaving line on lower aft ring needs renewed around the body of the ring. lower fwd ring requires a new line for the water light.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 1 June 2016
Resolution: Worn rings have been replaced with new life rings.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 18 May 2016 Resolved
Provide drug and alcohol pre-employment teting and test strips.
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 1 June 2016
Resolution: All required documentation has been presented and accepted.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 18 May 2016 Resolved
Properly label upper deck life jacket stowage.
Action required: 705 - Other - as specified
Due 18 June 2016
Resolved 1 June 2016
Resolution: Stowage benches are now properly labeled.
Fire Fighting › Fire Pumps › Pressure
Issued 4 June 2014 Resolved
Firepump tested and was not capable of producing the min req PSI of 60 (46CFR181.10-1 (a-d). Pump was only able to produce 25-30 PSI. Per CID vessel is required to repair/replace pump to meet regulations and in the interm must hv portable fire pump onboard in lieu of fixed pump AND/ OR submit alt FF action plan to [name withheld] 05Jun2014
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 16 June 2014
Resolution: 6/5/2014: Alt FF Plan recived via email. Vessel was instructed to schedule follow up exam NLT 16June2014 to fully clear def. 6/13/2014: Pump was tested at 80 PSI.
Documentation › Markings/Placards › Lifejacket Placard
Issued 4 June 2014 Resolved
Vsl must post PFD donning placard on both port/starbord bulkheads on both decks so that is easily visable to all PAX.
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 13 June 2014
Resolution: Placards Posted per req.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 4 June 2014 Resolved
1.Vsl must obtain a copy of the companys DAPI Policy statement and retain onboard. 2.Vsl must post required EAP Placard (Hotline) in space accessible to ALL crew.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 June 2014
Resolved 13 June 2014
Resolution: Policy Statement posted/EAP Placard posted.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 December 2011 Resolved
The Coast Guard amended its regulations governing the maximum weight and the number of passengers that may safely be permitted on board a passenger vessel based on a new Assumed Average Weight per Person (AAWPP) of 185lbs per person. The new regulations came into effect on December 01, 201. Based on the new AAWPP your vessel has been restricted to the following passenger count: 517 passengers 6
Action required: 705 - Other - as specified
Resolved 27 February 2012
Resolution: New stability letter issued by MSC COI Ammended by SDB. Cleared 835.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 5 July 2011 Resolved
Not to use shore-tie till it could be properly inspected for damage and insulation was repaired.
Action required: 705 - Other - as specified
Resolved 17 July 2011
Resolution: new shore-tie purchased, cleared 835 SAT.
Electrical › Lighting (service) › Lighting Fixture
Issued 5 July 2011 Resolved
Not to operate main deck port side forward lighting fixture till it could be replaced.
Action required: 705 - Other - as specified
Resolved 17 July 2011
Resolution: light replaced, cleared SAT.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 23 April 2008 Resolved
Forward pilothouse bilge alarm panel was not working properly. All compartment bilge high level alarms were tested and the aft pilot house bilge alarm panel worked properly.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 May 2008
Resolved 2 May 2008
Resolution: Forward pilothouse bilge alarm panel tested, all SAT.
Fire Fighting › Fire Hoses › Condition
Issued 21 April 2008 Resolved
50 ft fire hose connected to fire station #2 had a hole and was leaking.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2008
Resolved 2 May 2008
Resolution: New hose conected to fire station #2, all SAT.
Lifesaving › Lifejacket/PFD (Type IV) › Retroreflective Material
Issued 27 June 2006 Resolved
Provide reflective tape on fwd ring bouy.
Action required: 705 - Other - as specified
Due 15 July 2006
Resolved 25 July 2006
Resolution: Witnessed new tape.
Engineering › Freshwater System (jacketwater cooling) › Storage Tank
Issued 27 June 2006 Resolved
Repair leak on fwd (#2) main engine expansion tank.
Action required: 705 - Other - as specified
Due 8 August 2006
Resolved 6 September 2006
Resolution: New tank was fabricated & installed.
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 27 June 2006 Resolved
Repair #1 MDE oil pressure gauge.
Action required: 705 - Other - as specified
Due 25 July 2006
Resolved 25 July 2006
Resolution: Witnessed proper operation.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 27 June 2006 Resolved
Prove approval of engine room CO2 extinguisher.
Action required: 705 - Other - as specified
Due 15 July 2006
Resolved 25 July 2006
Resolution: Witnessed removal of old extinguisher.
Communications › Alarms/Indicators › Fire Alarm
Issued 27 June 2006 Resolved
Prove operation of heat detection system.
Action required: 705 - Other - as specified
Due 26 July 2006
Resolved 26 July 2006
Resolution: Witnessed test.
Lifesaving › Lifejacket/PFD (General)
Issued 2 January 2003 Resolved
Properly stow all life preservers on board prior to operating with passengers.
Due 3 January 2003
Resolved 21 March 2003
Resolution: Life preservers properly stowed.
Engineering › Steering Gear System
Issued 2 January 2003 Resolved
Provide a CG approved steering gear and equipment plan that reflect the as built system.
Due 2 February 2003
Resolved 26 March 2003
Resolution: Plan proved.
Accommodation/Occupational Safety › Occupational Safety
Issued 2 January 2003 Resolved
Provide adequate guards IWO fwd and aft shafts within each void space.
Due 2 February 2003
Resolved 21 March 2003
Operations/Management › Vessel Safety Management
Issued 2 January 2003 Resolved
Provide Station Bill for examination and signature of CG Marine Inspector. (more than four crew?)
Due 2 February 2003
Resolved 26 March 2003
Resolution: Station bill provided.
Documentation › Certificates/Documents
Issued 2 January 2003 Resolved
Provide on board a valid FCC Safety Radio Certificate and Station License.
Due 2 February 2003
Resolved 21 March 2003
Resolution: Provided License.
Documentation › Certificates/Documents
Issued 2 January 2003 Resolved
Provide and post valid Stability letter prior to operating with passengers.
Due 3 January 2003
Resolved 20 March 2003
Resolution: Provided Stability letter.
Lifesaving › Embarkation Appliances/Stations
Issued 2 January 2003 Resolved
Conduct sat Man overboard drill in presence of CG Marine Inspector prior to operating with passengers.
Due 3 January 2003
Resolved 26 March 2003
Resolution: Conducted Drills.
Operations/Management › Drug and Alcohol Testing
Issued 2 January 2003 Resolved
Conduct Drug and Alchohol Program Audit.
Due 2 February 2003
Resolved 21 March 2003
Resolution: Audit conducted.
Operations/Management
Issued 2 January 2003 Resolved
Contact Local OCMI and conduct "new-to-zone" inspection prior to operating with passengers.
Due 2 January 2003
Resolved 26 March 2003
Resolution: Conducted new to zone inspection.
Navigation › Piloting/Steering
Issued 2 January 2003 Resolved
Aft P/H compass deemed unstable by adjuster. Requires to be Reswung. LEGACY COMPONENT DESC: Compass Deviation Table
Due 2 March 2003
Resolved 26 March 2003
Resolution: Reswung compass.
Lifesaving
Issued 31 July 2000 Resolved
Provide 2 way communications between operating station and engineroom as per 46 CFR 184.602.
Condition: Unknown
Due 31 July 2000
Resolved 31 July 2000
Lifesaving
Issued 9 May 1996 Resolved
PROVIDE 6 RED HAND FLARES, VESSEL RESTRICTED TO DAYLIGHT OPERATIONS UNTIL _x001C_THIS REQUIREMENT IS CLEARED.
Condition: Unknown
Due 9 May 1996
Resolved 9 May 1996
Lifesaving
Issued 9 May 1996 Resolved
PROPVIDE PROPER LINE FOR RING BUOYS.
Condition: Unknown
Due 9 May 1996
Resolved 9 May 1996
Lifesaving
Issued 9 May 1996 Resolved
PROPERLY MARK DISTRESS SIGNAL CONTAINER.
Condition: Unknown
Due 9 May 1996
Resolved 9 May 1996
Deck/Cargo
Issued 17 April 1985 Resolved
INSTALL ADEQUATE DUCTED SUPPLY AND EXHAUST VENTILATION FOR MACHINERY SPACE IN ACCORDANCE WITH 46 CFR 182.20-45.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985

Casualty record · 3

18 March 2003Routine · role: Involved in a Marine Casualty · activity 1760758
7 July 2010Significant Marine Casualty · role: Subject of Search and Rescue · serious marine incident, as classified · 2 dead · 8 injured · activity 3789262
5 July 2011Routine · role: Involved in a Marine Casualty · activity 4070170
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.