MAURY USCG vessel records Sign in
← All vessels

DYNAMYTE II

DYNAMYTE II is a 1960 passenger vessel (inspected). The Coast Guard has recorded 34 inspections since 1985, most recently in April 2007, along with 32 deficiencies.

Records from 1985 to 2007. Most recent: inspection, 23 April 2007.

Built
1960
Last inspected
23 April 2007
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WVT9777
Flag
UNITED STATES
—
Maury page id
psix-53059

Inspections, by type

…with no type recorded2
Years with a record 21 calendar years (1985–2007)
The 34 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it14 - Regulatory (Subpart C or D), Net Ton
17 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 34

23 April 2007 Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2913971
21 July 2006 COI Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2716239
18 July 2005 Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2480982
7 March 2005 Hull Examination · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2315034
16 July 2004 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2142100
1 April 2004 Hull Examination · Annual Inspection · Administrative Inspection · Internal Structural Exam
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2035312
27 July 2003 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2035339
26 July 2001 COI Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1428067
25 August 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 779704
11 May 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 794822
26 April 1999 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1128170
4 April 1999 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 785737
22 January 1999 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1122407
19 May 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1126220
3 June 1997 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 774404
12 November 1996 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1172494
6 June 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1085760
26 June 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1190605
26 May 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1185196
22 September 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1177379
2 June 1994 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 867064
17 June 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1152834
24 July 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 955696
12 June 1991 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1251242
23 October 1990 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 924859
26 June 1990 Hull Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1213583
11 January 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1214018
15 June 1989 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236798
20 June 1988 Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1195912
24 June 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031004
26 August 1986 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1310702
4 November 1985 Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1306157
10 July 1985 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 998420
18 June 1985 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 998416

Deficiency record · 32

Fire Fighting › Ventilation Systems › Ducts
Issued 18 July 2005 Resolved
Install ventilation intake and exhaust openings to meet a min. of 12 sq. inches.
Due 18 July 2005
Resolved 1 August 2005
Resolution: Installation verified.
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 18 July 2005 Resolved
Bond port and stbd fuel hose to fill pipe and fuel tank
Due 18 July 2005
Resolved 1 August 2005
Resolution: Installation verified.
Engineering › Fuel Oil Service System › Hose
Issued 16 July 2004 Resolved
Prove proper hose type for fuel line indicated at inspection.
Due 30 July 2004
Resolved 30 July 2004
Resolution: Resolved.
Documentation › Markings/Placards › Warning Signs
Issued 16 July 2004 Resolved
Move radio emergency placard to area in proximity of radio.
Due 30 July 2004
Resolved 30 July 2004
Resolution: Moved.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 16 July 2004 Resolved
[name withheld] life jacket storage area including number oif jackets.
Due 30 July 2004
Resolved 30 July 2004
Resolution: Completed.
Engineering › Bilge Water Management System › Hose
Issued 16 July 2004 Resolved
Replace bilge dx hose with correct type and double clamp.
Due 30 July 2004
Resolved 30 July 2004
Resolution: Resolved.
Documentation › Markings/Placards › Capacity Marking
Issued 16 July 2004 Resolved
Mark passengers allowed for upper deck IAW Stability letter.
Due 30 July 2004
Resolved 30 July 2004
Resolution: Completed.
Engineering › Steering Gear System › Actuator
Issued 16 July 2004 Resolved
Slight Leak at qaudrant - steering bracket. water protruding into steering compt when going astern. will be reassed at drydock in Apr 2005. Operator to check prior to getting U/W and make 30 minute rounds.
Action required: 705 - Other - as specified
Resolved 21 July 2006
Resolution: No leaks during current inspection, def closed.
Fire Fighting
Issued 22 January 1999 Resolved
Submit plans for review and approval for the installation of a Fixed Fire Fighting System in the machinery spaces in accordance with 46 CFR 181.115(b) and 46 CFR 181.400
Condition: Unknown
Due 8 May 1999
Resolved 8 May 1999
Fire Fighting
Issued 22 January 1999 Resolved
Install a Fixed Fire Fighting System in machinery spaces in accordance withU.S. Coast Guard approved plans.
Condition: Unknown
Due 8 May 1999
Resolved 8 May 1999
Fire Fighting
Issued 22 January 1999 Resolved
Vessel is not to be operated with passengers for hire after March 11, 1999,until the above requirements have been cleared to the satisfaction of an attending U.S. Coast Guard Marine Inspector.
Condition: Unknown
Due 8 May 1999
Resolved 8 May 1999
Lifesaving
Issued 6 June 1996 Resolved
PROVIDE PROPER LINE FOR RING BUOY.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Engineering
Issued 6 June 1996 Resolved
POST POLLUTION PREVENTION PLACARD.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Electrical
Issued 6 June 1996 Resolved
PROVIDE BATTERY BOX COVERS.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Lifesaving
Issued 6 June 1996 Resolved
PROPERLY MARK DISTRESS SIGNAL CONTAINER.
Condition: Unknown
Due 6 June 1996
Resolved 6 June 1996
Fire Fighting
Issued 2 June 1994 Resolved
PROVIDE ONE ADDITIONAL FIRE EXTINGUISHER BRACKET.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Engineering
Issued 2 June 1994 Resolved
LABEL PORT SIDE REMOTE FUEL SHUT OFF.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Lifesaving
Issued 2 June 1994 Resolved
PROVIDE EVIDENCE OF COMPLIANCE WITH CHEMICAL TESTING REGULATIONS.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Lifesaving
Issued 2 June 1994 Resolved
LABEL LIFEJACKET STORAGE BINS.
Condition: Unknown
Due 2 June 1994
Resolved 2 June 1994
Lifesaving
Issued 26 June 1990 Resolved
PROVIDE 6 ORANGE SMOKE SIGNALS.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Construction/Loadline
Issued 26 June 1990 Resolved
STENCIL NAME ON PORT & STBD BOWS.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Accommodation/Occupational Safety
Issued 26 June 1990 Resolved
PROVIDE 3 COURSE RAILING ON UPPER DECK.
Condition: Unknown
Due 26 June 1990
Resolved 26 June 1990
Unknown
Issued 15 June 1989 Resolved
PROVIDE 1 ADDITIONAL LIFE PRESERVER, PRIOR TO COMPLETING THIS REQUIREMENT; NOT MORE THAN 24 PERSONS ARE ALLOWED ONBOARD.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Documentation
Issued 20 June 1988 Resolved
POST THE VESSEL'S STABILITY LETER ONBOARD.
Condition: Unknown
Due 20 June 1988
Resolved 20 June 1988
Lifesaving
Issued 20 June 1988 Resolved
PROVIDE ONE ADDITIONAL ADULT LIFE PRESERVER PRIOR TO COMPLETION OF THIS REQUIREMENT NOT MORE THAN 22 PERSONS ARE ALLOWED ONBOARD.
Condition: Unknown
Due 20 June 1988
Resolved 20 June 1988
Accommodation/Occupational Safety
Issued 20 June 1988 Resolved
INSTALL ADDITIONAL HANDRAIL COURSES ON UPPER DECK PRIOR TO COMPLETION OF THIS REQUIREMENT; PASSENGERS ARE NOT PERMITTED ON THE UPPER DECK.
Condition: Unknown
Due 20 June 1988
Resolved 20 June 1988
Construction/Loadline
Issued 24 June 1987 Resolved
PROVE PROPER OPERATION OF BELT DRIVEN JABSCO BILGE PUMP.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Lifesaving
Issued 24 June 1987 Resolved
REPLACE 3 ORANGE DISTRESS FLARES.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Documentation
Issued 24 June 1987 Resolved
OPROVIDE VALID FCC SHIP STATION LICENSE FOR VHF RADIO.
Condition: Unknown
Due 24 June 1987
Resolved 24 June 1987
Lifesaving
Issued 18 June 1985 Resolved
PROVIDE 1 ADDITIONAL USCG APPROVED TYPE F PFD.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985
Electrical
Issued 18 June 1985 Resolved
REMOVE ALL 110V ELECTRICAL WIRING THROUGHOUT THE VESSEL.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985
Electrical
Issued 18 June 1985 Resolved
SECURE EXISTING 12V WIRING WHICH IS NOT SECURE WITHIN ELECTRICAL JUNCTION BOXES OR PROPERLY SOLDER AND TAPE EACH CONNECTION.
Condition: Unknown
Due 18 June 1985
Resolved 18 June 1985

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.