MAURY USCG vessel records Sign in
← All vessels

SPILL SPOILER I

SPILL SPOILER I is a 1974 passenger vessel (inspected). The Coast Guard has recorded 65 inspections since 1985, most recently in November 2020, along with 82 deficiencies and 1 casualty investigation in 2012.

Records from 1985 to 2020. Most recent: inspection, 10 November 2020.

Built
1974
Last inspected
10 November 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-53082

Inspections, by type

…with no type recorded1
Years with a record 29 calendar years (1985–2020)
The 65 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it46 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WXN2249MMSI not assigned · expired · voluntarily equipped · granted 2 March 1999, cancelled 2 May 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 65

10 November 2020 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7104698
15 July 2020 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7001233
1 July 2019 Internal Structural Exam · Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6732584
4 June 2019 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6702574
5 June 2018 Internal Structural Exam · Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6435263
1 May 2018 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6403425
31 May 2017 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6166203
22 June 2016 Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5915290
26 May 2016 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5900573
25 June 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4396106
2 June 2008 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3213708
13 June 2007 Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2962967
17 July 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2715860
17 August 2005 Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2464067
21 July 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2393646
14 July 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2130448
8 October 2003 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1912036
2 September 2003 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1883163
14 July 2003 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1846413
19 June 2003 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1818954
8 August 2001 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1464404
31 July 2001 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1069586
12 June 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1384799
24 July 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1469976
28 September 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1424810
30 July 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1442876
29 July 1998 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1129666
6 October 1997 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1027834
29 July 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1462588
16 August 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1087766
12 August 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1355903
23 July 1996 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1031656
5 July 1996 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1092924
29 February 1996 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 885578
11 August 1995 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1192916
8 September 1994 Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 864580
16 August 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 847197
11 August 1994 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1174564
2 May 1994 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 858553
29 April 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 858772
28 January 1994 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1165393
8 December 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1458124
22 September 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1358173
18 May 1993 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1151251
27 October 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1262879
23 October 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1256216
24 September 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 935817
24 August 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 949523
8 July 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 958586
6 August 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1251652
9 July 1991 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1246938
6 August 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1239984
28 August 1989 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1194814
27 July 1989 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1350895
27 June 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 897457
3 February 1989 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 897895
12 September 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1040427
5 July 1988 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1206366
4 December 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1000561
14 October 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1322042
23 July 1987 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1020451
25 June 1987 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1009864
25 June 1987 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1328284
1 July 1986 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1304701
21 June 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 981867

Deficiency record · 82

09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 15 July 2020 Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters: "EMERGECY EXIT, KEEP CLEAR". Engine room emergency escapes are not marked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 August 2020
Resolution: Saw signage
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 2 June 2008 Resolved
Remove PFD's from protective coverings in order to make them readily accessible.
Due 3 June 2008
Resolved 2 June 2008
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Immediately Available
Issued 2 June 2008 Resolved
Replace shackle attachment device with snap-hook in order to make waterllight easily removable.
Due 3 June 2008
Resolved 2 June 2008
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 18 July 2006 Resolved
Install properly sized batteries into waterlights. Existing batteries were the heavy duty ones that made the waterlights sink below the surface.
Action required: 705 - Other - as specified
Resolved 18 July 2006
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 July 2006 Resolved
Install detachable corrosion resistant clip onto life ring with 3 ft line connected to watertight.
Action required: 705 - Other - as specified
Resolved 18 July 2006
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 July 2006 Resolved
Provide updated navigation publications (light list and Coast Pilot).
Action required: 705 - Other - as specified
Resolved 18 July 2006
Lifesaving › Lifefloat › Retroreflective Material
Issued 18 July 2006 Resolved
Renew retro reflective tape on life float.
Action required: 705 - Other - as specified
Resolved 18 July 2006
Stability › Watertight Integrity › General
Issued 18 July 2006 Resolved
Make fwd port compartment watertight in way of electrical stuffing tube on aft bulkhead.
Action required: 705 - Other - as specified
Resolved 18 July 2006
Construction/Loadline › Structures › Scuttle
Issued 17 August 2005 Resolved
Renew gaskets for the port and starboard generator void scuttles.
Due 17 September 2005
Resolved 24 August 2005
Engineering › Thrusters › Piping
Issued 17 August 2005 Resolved
Provide plans to renew worn port and starboard bow thruster wear rings and make thruster tube available for inspection upon removal of wear rings prior to receiving credit for dry dock.
Due 17 September 2005
Resolved 24 August 2005
Engineering › Thrusters › Bearing
Issued 17 August 2005 Resolved
Provide end play specification for port and starboard bow thrusters.
Due 17 September 2005
Resolved 24 August 2005
Resolution: Bow thruster shafts renewed.
Construction/Loadline › Penetrations › Bottom Plug
Issued 17 August 2005 Resolved
Properly seal abandoned thru-hull penetration in forepeak.
Due 17 September 2005
Resolved 17 August 2005
Resolution: Expandable test plug removed and replaced with metallic plug.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 21 July 2005 Resolved
Provide proof of current COD.
Action required: 705 - Other - as specified
Resolved 25 July 2005
Resolution: OCMI resended.
Documentation › Manuals/Policy Documentation › Stability Instructions
Issued 21 July 2005 Resolved
Properly post stability letter at operating station.
Action required: 705 - Other - as specified
Resolved 21 July 2005
Resolution: Policy letter posted. Exempt from Stability test.
Lifesaving › Lifefloat › Float Free
Issued 21 July 2005 Resolved
Make L/F float free in way of painter line.
Action required: 705 - Other - as specified
Resolved 21 July 2005
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 21 July 2005 Resolved
Make waterlight operational in way of batteries.
Action required: 705 - Other - as specified
Resolved 21 July 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 July 2004 Resolved
Install guard on port main engine alternator as indicated by the attending marine inspector.
Action required: 705 - Other - as specified
Due 15 August 2004
Resolved 15 July 2004
Construction/Loadline › Structures › End Bulkhead
Issued 8 October 2003 Resolved
Make bulkhead penetration in way of electrical stuffing tube at number 2 bulkhead in each sponson watertight.
Action required: 705 - Other - as specified
Due 8 October 2003
Resolved 8 October 2003
Resolution: Correct sized packing installed into bulkhead stuffing tube.
Documentation › Certificates/Documents
Issued 19 June 2003 Resolved
Provide current radio operator permit (FCC).
Due 19 July 2003
Resolved 1 July 2003
Resolution: Reasearch revealed, the opeator does not meet the requirements for a marine operators permit IAW FCC rules and regulations. This vessel is less than 300 gross tons and carries less than 6 passengers for hire.
Documentation › Certificates/Documents
Issued 19 June 2003 Resolved
Provide current radio safety certificate (FCC).
Due 19 July 2003
Resolved 1 July 2003
Resolution: Research revealed, vessel is not required to have a radio safety certificate, vessel does not operate more than 20 nm from safe refuge and does not carry a mediam frequency radio onboard.
Operations/Management › Drug and Alcohol Testing
Issued 19 June 2003 Resolved
Provide proof of drug testing results.
Due 19 July 2003
Resolved 20 June 2003
Accommodation/Occupational Safety › Medical/First Aid
Issued 19 June 2003 Resolved
Re-supply first aid kit contents IAW 46 CFR 184.710. LEGACY COMPONENT DESC: Medicine Chest
Due 19 July 2003
Resolved 2 September 2003
Navigation › Piloting/Steering
Issued 19 June 2003 Resolved
Provide up to date charts for area of operation IAW 46 CFR 184.420. LEGACY COMPONENT DESC: Marine Charts
Due 19 July 2003
Resolved 2 September 2003
Navigation › Piloting/Steering
Issued 19 June 2003 Resolved
Provide current Coast Pilot and Light List IAW 46 CFR 184.420.
Due 19 July 2003
Resolved 2 September 2003
Communications › Radio Communications
Issued 19 June 2003 Resolved
Provide emergency broadcast placard for radios in way of pilothouse IAW 46 CFR 184.506.
Due 19 July 2003
Resolved 2 September 2003
Engineering › Bilge Water Management System
Issued 19 June 2003 Resolved
Provide proof of operation for high water alarm stbd engine room.
Due 19 July 2003
Resolved 2 September 2003
Electrical › Electrical Distribution System (service)
Issued 19 June 2003 Resolved
Label all 110vac breakers in pilothouse panel. LEGACY COMPONENT DESC: Panelboard
Due 19 July 2003
Resolved 2 September 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 19 June 2003 Resolved
Service B II fire extinguisher located port side maindeck adjacent to port side gear locker.
Due 19 July 2003
Resolved 2 September 2003
Electrical
Issued 19 June 2003 Resolved
Remove or tape, fold back and label dead end wiring in way of head.
Due 19 July 2003
Resolved 2 September 2003
Engineering › Generator (propulsion-electric)
Issued 19 June 2003 Resolved
Replace port generator fuel supply hose between manifold and primary fuel filter with hose meeting J 1942 standards, 46 CFR 182.720.
Due 19 July 2003
Resolved 2 September 2003
Electrical › Electric Supply System (service)
Issued 19 June 2003 Resolved
Provide plan and drawings for replacement of starting battery cables to main propulsion engines and generators in way of port and stbd engine rooms. Cable to be marine grade battery type.
Due 19 July 2003
Resolved 2 September 2003
Engineering › Bilge Water Management System
Issued 19 June 2003 Resolved
Provide plans for installation of high water alarm sensors in way of stbd forepeak, port and stbd center voids.
Due 19 July 2003
Resolved 2 September 2003
Engineering › Bilge Water Management System
Issued 19 June 2003 Resolved
Prove proper operation of bilge suction in way of port forepeak, stbd engine room and stbd voids.
Due 19 July 2003
Resolved 2 September 2003
Lifesaving
Issued 19 June 2003 Resolved
Vessel restricted to 6 persons until proper size life float is provided IAW 46 CFR 180.205 (b)
Due 19 July 2003
Resolved 1 July 2003
Resolution: Owner has opted to reduce total capacity to no more than 6, amended max pax to reflect change.
Deck/Cargo
Issued 12 August 1996 Resolved
REPLACE CORRODED AND FISHHOOKED SECTION OF CRANE CABLING IWO THIMBLE. THIS REQUIREMENT TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 September 1996
Resolved 22 August 1996
Construction/Loadline
Issued 12 August 1996 Resolved
ENSURE WATERTIGHTNESS OF FOREPEAK AFT BULKHEADS IN BOTH HULLS TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 September 1996
Resolved 22 August 1996
Construction/Loadline
Issued 12 August 1996 Resolved
REPLACE GASKET IN DECK SCUTTLE ADJACENT TO DECK CRANE TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 September 1996
Resolved 22 August 1996
Documentation
Issued 12 August 1996 Resolved
PROVIDE EVIDENCE OF PARTICIPATION IN A DOT APPROVED DRUG TESTING PROGRAM TOTHE SATISFACTION OF THE ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 September 1996
Resolved 22 August 1996
Construction/Loadline
Issued 11 August 1994 Resolved
PROPERLY MARK NET TONNAGE ON VESSEL.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Construction/Loadline
Issued 11 August 1994 Resolved
PRIOR TO 30 SEPTEMBER 1994, ACCOMPLISH A SATISFACTORY DRY DOCKING IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 9 September 1994
Resolved 9 September 1994
Fire Fighting
Issued 8 December 1993 Resolved
PROVIDE SUFFICANT HOSES TO REACH ALL AREAS OF THE VESSEL FOR THE HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 8 December 1993
Resolved 8 December 1993
Fire Fighting
Issued 22 September 1993 Resolved
REPLACE BROKEN HAND FIRE/BILGE PUMP.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Engineering
Issued 22 September 1993 Resolved
INSTALL FLAME IMPINGEMENT BOWLS ON BOTH FUEL FILTERS
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Unknown
Issued 22 September 1993 Resolved
CLEAN OILY WATER FROM BILGES OF ENGINE ROOMS.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Deck/Cargo
Issued 22 September 1993 Resolved
INSTALL FLAME SCREENS(30X30 MESH) TO BOTH DIESEL OIL TANKS FOR BELT SYSTEMS
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Fire Fighting
Issued 22 September 1993 Resolved
SERVICE PORTABLE AND FIXED FIRE EXTINGUISHER'S.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Lifesaving
Issued 22 September 1993 Resolved
MOVE GAS CAN TO A LOCATION NEAR THE SIDE OF THE VESSEL AND STORE FOR EASY JETTISON IN CASE OF FIRE.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Construction/Loadline
Issued 22 September 1993 Resolved
PROVE OPERATION OF STBD BILGE PUMP.
Condition: Unknown
Due 22 September 1993
Resolved 22 September 1993
Deck/Cargo
Issued 24 September 1992 Resolved
PROVIDE PRESSURE GAUGE FOR CARGO TRANSFER PUMP IAW 46 CFR 32.50-5(b).
Condition: Unknown
Due 24 September 1992
Resolved 24 September 1992
Unknown
Issued 24 September 1992 Resolved
PROVIDE PORTABLE COMBUSTIBLE GAS METER IAW MVI POLICY LTR 03-92.
Condition: Unknown
Due 24 September 1992
Resolved 24 September 1992
Accommodation/Occupational Safety
Issued 24 September 1992 Resolved
PROVIDE P/V VENT FOR RECOVERY TANKS IAW MVI POLICY LTR 03-92.
Condition: Unknown
Due 24 September 1992
Resolved 24 September 1992
Documentation
Issued 24 August 1992 Resolved
PROVIDE RADIO OPERATORS PERMIT.
Condition: Unknown
Due 27 October 1992
Resolved 27 October 1992
Accommodation/Occupational Safety
Issued 24 August 1992 Resolved
PROPERLY SECURE MSD O/B DISCHARGE VALVE WITH SECURING DEVICE.
Condition: Unknown
Due 5 October 1992
Resolved 5 October 1992
Engineering
Issued 24 August 1992 Resolved
REPAIR STBD EMERGENCY FUEL SHUT-OFF VALVE.
Condition: Unknown
Due 5 October 1992
Resolved 5 October 1992
Lifesaving
Issued 24 August 1992 Resolved
PROVIDE 8 IMMERSION SUITS.
Condition: Unknown
Due 30 November 1992
Resolved 23 October 1992
Documentation
Issued 24 August 1992 Resolved
PROVIDE CURRENT DEVIATION CARD.
Condition: Unknown
Due 5 October 1992
Resolved 5 October 1992
Lifesaving
Issued 24 August 1992 Resolved
REPLACE RING BUOY ON STBD AFT OF VSL.
Condition: Unknown
Due 5 October 1992
Resolved 5 October 1992
Lifesaving
Issued 24 August 1992 Resolved
REPLACE PADDLES TO LIFE FLOAT. ENSURE NEW ONES ARE AT LEAST 4 FT. LONG.
Condition: Unknown
Due 5 October 1992
Resolved 5 October 1992
Documentation
Issued 24 August 1992 Resolved
PROVIDE RADIO TELEPHONY CERTIFICATE.
Condition: Unknown
Due 5 October 1992
Resolved 5 October 1992
Navigation
Issued 24 August 1992 Resolved
REPAIR HYDRAULIC LEAK ON THE TOP OF THE STBD STEERING AND BUCKET CONTROL HYDRAULIC PUMP.
Condition: Unknown
Due 5 October 1992
Resolved 5 October 1992
Fire Fighting
Issued 24 August 1992 Resolved
SERVICE ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 4 September 1992
Resolved 4 September 1992
Documentation
Issued 24 August 1992 Resolved
PROVIDE VSL WITH CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 24 August 1992
Resolved 24 August 1992
Construction/Loadline
Issued 9 July 1991 Resolved
PROPERLY GASKET ENGINE ROOM HATCHES.
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Documentation
Issued 9 July 1991 Resolved
PROVIDE A COPY OF DRUG TESTING PROGRAM IAW 46 CFR 16.401.
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Engineering
Issued 9 July 1991 Resolved
PROPERLY MARK FUEL SHUT-OFF VALVES.
Condition: Unknown
Due 9 July 1991
Resolved 9 July 1991
Engineering
Issued 27 July 1989 Resolved
INSTALL CHAFE FOR STEERING HYDRAULIC LINES IN STBD MACHINERY SPACE.
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Fire Fighting
Issued 27 July 1989 Resolved
REPLACE CREWS QUARTER B-I FIRE EXTINGUISHER WITH A B-II FIRE EXTINGUISHER.
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Lifesaving
Issued 27 July 1989 Resolved
RENEW ALL FLARES: 6 RED AND 6 ORANGE (FLARES ONBOARD EXPIRE 8/89.
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Lifesaving
Issued 27 July 1989 Resolved
RENEW RING LIFE BUOY STATIONED AT WHEELHOUSE. (SERVICABLE BUT DETERIORATING
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Lifesaving
Issued 27 July 1989 Resolved
REPLACE BATTERY IN LIFEFLOAT WATER LIGHT.(WEAK)
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Lifesaving
Issued 27 July 1989 Resolved
RENEW GRABLINES ON LIFE FLOAT WHERE DETERIORATING.
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Lifesaving
Issued 27 July 1989 Resolved
RESTENCIL VESSEL NAME ON LIFE FLOAT PADDLES WHERE FADED.
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Construction/Loadline
Issued 27 July 1989 Resolved
REPAIR OR REPLACE PORT FOREPEAK SCUTTLE WHERE CRACKED (3) AND WARPED.
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Construction/Loadline
Issued 27 July 1989 Resolved
REPLACE OR REGLUE GASKET FOR PORT FOREPEAK SCUTTLE.
Condition: Unknown
Due 27 July 1989
Resolved 27 July 1989
Engineering
Issued 12 September 1988 Resolved
PROPERLY MARK THE LOCATION OF THE EMERGENCY FUEL OIL SHUT OFF VALVES.
Condition: Unknown
Due 12 September 1988
Resolved 12 September 1988
Fire Fighting
Issued 12 September 1988 Resolved
SERVICE ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 12 September 1988
Resolved 12 September 1988
Fire Fighting
Issued 12 September 1988 Resolved
SERVICE 50# CO2 BOTTLES FOR FIXED FIRE FIGHTING SYSTEM. HYDRO TEST THE STARBOARD CO2 BOTTLE.
Condition: Unknown
Due 12 September 1988
Resolved 12 September 1988
Electrical
Issued 14 October 1987 Resolved
PROVE OPERATION OF GAS DETECTION SYSTEM TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 14 October 1987
Resolved 14 October 1987
Electrical
Issued 25 June 1987 Resolved
PROVIDE PROPER LINING FOR BATTERY BOXES UTILIZING LEAD OR FIBERGLASS.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Lifesaving
Issued 25 June 1987 Resolved
PROVIDE WATERTIGHT CONTAINER FOR DISTRESS SIGNALS.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Electrical
Issued 25 June 1987 Resolved
PROVIDE PROTECTIVE COVERS FOR BATTERY TERMINALS.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987
Lifesaving
Issued 25 June 1987 Resolved
STENCIL VESSEL NAME ON ONE ADULT LIFE PRESERVER AS DIRECTED.
Condition: Unknown
Due 25 June 1987
Resolved 25 June 1987

Casualty record · 1

29 September 2012Routine · role: Involved in a Marine Casualty · activity 4455612
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.