Records from 2016 to 2022. Most recent: inspection, 16 August 2022.
Documentation record
Registered dimensions (L × B × D)34.5 ft × 12.0 ft × 6.1 ft
Registered tonnagegross 13 / net 10
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderEVERGREEN STATE COLLEGE · OLYMPIA, WA, UNITED STATES · built 1981
Hull materialWood
PropulsionAuxiliary Sail
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portPORT TOWNSEND, WA
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it13 - Regulatory (Subpart C or D), Gross Ton
10 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 11
16 August 2022
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7535630
16 August 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7289391
20 May 2021
Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7255207
25 January 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7130157
5 March 2020
COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6921558
30 December 2019
COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6872832
7 November 2019
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6851564
20 August 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6518235
23 August 2017
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6250510
22 June 2017
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6163433
12 August 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5949572
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 August 2021
Resolved
Seawulff failed to complete DDX/ISE by deadline date of 30Jun21.
Action required: 701 - Prior to carriage of passengers/cargo
Due 25 August 2021
Resolved 25 August 2021
Resolution: Performed DDX/ISE inspection.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 March 2020
Resolved
Must permanently fix heat exchange to engine block.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 April 2020
Resolved 21 May 2020
Resolution: Vessel rep sent photo verifying engine block mounted
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 December 2019
Resolved
FCC Safety Radiotelephony certificate is expired.
47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2020
Resolved 5 March 2020
Resolution: Vessel rep provided valid FCC Safety Radiotelephony certificate
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 30 December 2019
Resolved
Vessel must maintain adequate and up-to-date charts and publications to include: Coast Pilot [name withheld], Tides, and Currents. Unknown when the Coast Pilot was last updated. The Light List was from 2015. The Tides Table was for 2019. There was no currents table. Required all the above publications to be updated.
46 CFR 184.420 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2020
Resolved 5 March 2020
Resolution: Vessel rep provided up-to-date charts and publications listed
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 December 2019
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. The plug on the ring buoy was deteriorated from the sun and easily disintegrated upon touching it. Ring Buoy must be replaced and the line connecting the life line to the ring buoy was disintegrating and must be replaced. Master plans to splice a new line.
Ring buoy must be replaced prior to departure.
46 CFR 176.808 (b)
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2020
Resolved 5 March 2020
Resolution: Vessel rep purchased new operable ring buoy and replaced line
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 30 December 2019
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:(1) A light to indicate discharge;(2) An audible alarm that sounds upon discharge; and (3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section. The Fireboy installed in the engine/machinery space was unable to shut the engines down and did not alarm at the operating station. Required to rewire the system as per manufacturers instructions and perform operational test in presence of marine inspector prior to departure.
46 CFR 181.420
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2020
Resolved 21 May 2020
Resolution: Vessel rep sent video of properly functioning fireboy, see MISLE activity #: 6921558
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 December 2019
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant OCMI.
The second means of escape for the below deck accommodation space does not have a sign on the main deck side of the hatch. Required to place the above markings on the hatch.
46 CFR 185.606
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 January 2020
Resolved 5 March 2020
Resolution: Vessel rep marked second means of escape with two new signs
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 December 2019
Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. Handles and securing devices must be permanently installed and not capable of being easily removed. A door, hatch or scuttle must open towards the expected direction of escape from the space served. The secondary emergency escape in the accommodation area leads up to the main deck. The hatch is fairly heavy and the jib boom is directly over the hatch opening and prevents the hatch from being fully opened. Discussed the concerns with the Master, Master plans to rig the topping lift and boom at a higher angle which will allow the hatch to open enough for persons to escape. Also required a post to be installed to hold the hatch in place when opened.
Required to fix the above prior to departure.
46 CFR 177.500 (h)
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2020
Resolved 5 March 2020
Resolution: Vessel rep demonstrated that modifications to escape hatch can be operated by one person and can remain open with installed hinge spring.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 December 2019
Resolved
Footholds, handholds, ladders, and similar means provided to aid escape, must be suitable for use in emergency conditions, of rigid construction, and permanently fixed in position, unless they can be folded, yet brought into immediate service in an emergency. Currently, it is difficult to push the secondary emergency escape hatch in the accommodation space open and climb out on to the main deck. Required to install a step for easier and universal accessibility.
Required to fix the above prior to departure.
46 CFR 177.500 (m)
Action required: 17 - Rectify deficiencies prior to departure
Due 30 January 2020
Resolved 5 March 2020
Resolution: Vessel rep demonstrated that modifications to escape hatch can be operated by one person and can remain open with installed hinge spring, steps were also installed to assist in egress.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 22 August 2018
Resolved
Provide an updated chart. Last update completed 5 Dec 2014.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2018
Resolution: Provided new charts
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 22 August 2018
Resolved
Provide a first aid kit with contents listed in 46 CFR 160.041-4
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 September 2018
Resolved 6 September 2018
Resolution: Provided new 1st aid kit.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 August 2018
Resolved
Provide at least (6) distress flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 September 2018
Resolution: Provided required flares.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 August 2018
Resolved
Provide DAPI information to include employee assistance information, hotline numbers, and DER/Crew training.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 November 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 August 2018
Resolved
Provide a working floating light for the ring buoy. Restricted to daylight operations.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 6 September 2018
Resolution: provided a working floatlight.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 22 August 2018
Resolved
Provide a fixed fire extinguishing system for the engine room.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2018
Resolved 10 January 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 August 2018
Resolved
Provide (02) adult life jackets. Total persons allowed reduced to 10.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 6 September 2018
Resolution: provided 2 new LJ.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 August 2018
Resolved
Provide a rigging inventory and maintenance inspection program IAW NVIC 02-16.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 December 2018
Resolved 10 January 2019