Records from 1985 to 1990. Most recent: inspection, 19 November 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
19 November 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1300668
26 August 1990
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 909606
21 August 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1235910
12 September 1989
Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 900293
13 June 1989
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1338226
28 April 1989
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1043634
3 February 1989
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1350623
14 September 1988
Re-Inspection · Drydock Extension
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1208725
3 November 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1328162
20 October 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1324535
1 October 1987
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1324470
23 September 1987
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1319572
12 September 1987
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1024984
6 September 1987
Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1013439
4 November 1986
Deficiency Check · Re-Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1007718
28 February 1986
Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1303762
13 November 1985
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1003198
Construction/Loadline
Issued 12 September 1989
Resolved
CROP AND RENEW SIDE SHELL AND ASSOCIATED INTERNALS IN NO. 2 PORT SEA WATER BALLAST PRELOAD TANK IN WAY OF INDENT LOCATED BETWEEN FRAMES 2 & 3 AT THE TURN OF THE BILGE.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Construction/Loadline
Issued 12 September 1989
Resolved
CROP/RENEW WASTED SIDE LONGITUDINALS, UNDERDECK LONGITUDINALS AND SWASH BULKHEAD IN NO. 1 SEA WATER BALLAST PRELOAD TANK. WASTAGE LOCATED IN UPPERHALF OF PORT SIDE OF TANK. PRIOR TO REPAIR PROVIDE COPY OF U.T. REPORT ANDREPAIR PLAN FOR REVIEW/APPROVAL OF [name withheld].
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Lifesaving
Issued 12 September 1989
Resolved
CONDUCT WEIGHT TEST ON STARBOARD LIFEBOAT IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Fire Fighting
Issued 12 September 1989
Resolved
SEND OUT FOR HYDROSTATIC TEST AND SERVICING TWELVE PORTABLE CO2 FIRE EXTINGUISHERS WITH HYDRO DATES OF OVER 5 YEARS. PROVIDE COPY OF SERVICING REPORT.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Construction/Loadline
Issued 12 September 1989
Resolved
PROVIDE COPY OF FINAL DIVER'S REPORT CONCERNING UNDERWATER SURVEY.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Construction/Loadline
Issued 12 September 1989
Resolved
PROVIDE COPY OF FINAL M.P.I. REPORT FROM BIXINDO UTAMA INSPECTION SERVICES CONCERNING HULL SURVEY AND WELD REPAIRS.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Lifesaving
Issued 12 September 1989
Resolved
TEST WATER SPRAY CURTAIN ON PORT AND STARBOARD LIFEBOATS IN THE PRESENCE OFA COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Lifesaving
Issued 12 September 1989
Resolved
RENEW PORT LIFEBOAT ENGINE THROTTLE CONTROL CABLE.
Condition: Unknown
Due 12 September 1989
Resolved 12 September 1989
Engineering
Issued 14 September 1988
Resolved
MAKE THE RIGS SIX DRY BULK TANKS AVAILABLE FOR INTERNAL INSPECTION BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 September 1988
Resolved 14 September 1988
Electrical
Issued 1 October 1987
Resolved
PRIOR TO COMMENCING DRILLING OPERATIONS, NOTIFY MSO HONOLULU OF THE SATIS- FACTORY OPERATION OF THE EMERGENCY GENERATOR UNDER LOAD AND TEST RESULTS OFTHE OVERSPEED TRIP, LOW LUBE OIL TRIP AND ALARM, AND THE HIGH TEMPERATURE ALARM.
Condition: Unknown
Due 1 October 1987
Resolved 1 October 1987
Fire Fighting
Issued 12 September 1987
Resolved
PROVIDE A REPORT OF THE FIRE FIGHTING FOAM ANALYSIS TO THE [name withheld], HAWAII
Condition: Unknown
Due 12 September 1987
Resolved 12 September 1987
Electrical
Issued 12 September 1987
Resolved
OPERATE AND TEST THE ALARMS AND SHUTDOWNS ON NUMBER ONE (1) GENERATOR AND THE EMERGENCY GENERATOR.
Condition: Unknown
Due 12 September 1987
Resolved 12 September 1987
Accommodation/Occupational Safety
Issued 12 September 1987
Resolved
PROVIDE A MESA OR MSHA APPROVED FIRST-AID KIT.
Condition: Unknown
Due 12 September 1987
Resolved 12 September 1987
Lifesaving
Issued 12 September 1987
Resolved
RENEW THE FALLS FOR LIFE RAFT WINCHES 1 AND 2.
Condition: Unknown
Due 12 September 1987
Resolved 12 September 1987
Lifesaving
Issued 12 September 1987
Resolved
RENEW THE OUTDATED SMOKE FLARES; PORT & STARBOARD.
Condition: Unknown
Due 12 September 1987
Resolved 12 September 1987
Fire Fighting
Issued 12 September 1987
Resolved
PROVIDE A COPY OF THE FIRE FIGHTING EQUIPMENT SERVICING REPORT FOR THE SERVICING CONDUCTED 10-11 SEP 87. MAIL A COPY TO THE [name withheld], HI.
Condition: Unknown
Due 12 September 1987
Resolved 12 September 1987
Fire Fighting
Issued 12 September 1987
Resolved
RENEW THE EXTINGUISHER HOOKS AND BRACKETS PER THE LIST PROVIDED BY THE UNITOR SERVICING REPORT OF 11 SEP 87.
Condition: Unknown
Due 12 September 1987
Resolved 12 September 1987
Unknown
Issued 13 November 1985
Resolved
CONDUCT INTERNAL EXAMINATION OR HYDROSTATIC TEST OF RIG FLOOR AIR RECEIVERS
Condition: Unknown
Due 13 November 1985
Resolved 13 November 1985
Fire Fighting
Issued 13 November 1985
Resolved
CONDUCT SERVICING OF ALL FIRE PROTECTION SYSTEMS.
Condition: Unknown
Due 13 November 1985
Resolved 13 November 1985
Unknown
Issued 13 November 1985
Resolved
CONDUCT SATISFACTORY TEST OF RIG FLOOR AIR RECEIVER SAFETY RELIEF VALVE.
Condition: Unknown
Due 13 November 1985
Resolved 13 November 1985
Unknown
Issued 13 November 1985
Resolved
PROVIDE CURRENT FOAM SAMPLE TEST REPORT.
Condition: Unknown
Due 13 November 1985
Resolved 13 November 1985