Records from 1985 to 1990. Most recent: inspection, 4 June 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 13
4 June 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 929981
13 January 1990
Examination of Repairs · Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 916699
7 November 1989
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1235458
8 September 1989
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 897739
27 January 1989
Deficiency Check · Damage Survey · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 895324
7 December 1988
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1208862
14 October 1988
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1199117
9 September 1988
Hull Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1205661
12 November 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1026538
19 February 1986
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1292715
5 February 1986
Credit Drydock
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 988412
27 November 1985
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 989416
5 September 1985
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1294760
Lifesaving
Issued 13 January 1990
Resolved
REVISE THE LIFESAVING FIRE CONTROL PLAN TO REFLECT CURRENT LOCATION OF ALL LIFESAVING EQUIPMENT.
Condition: Unknown
Due 13 March 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Electrical
Issued 13 January 1990
Resolved
PROVIDE COPY OF MEGGAR READINGS FOR ALL EXTERIOR MOTORS, CABLE RUNS, LIGHTING CIRCUITS, AND VENT MOTORS.
Condition: Unknown
Due 13 March 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Construction/Loadline
Issued 13 January 1990
Resolved
REINSTALL STBD LEG ANCHORED JACKING GEAR UNIT #2, VERIFY OPERATION, AND PROVIDE RESULTS TO [name withheld], HI.
Condition: Unknown
Due 13 March 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Lifesaving
Issued 13 January 1990
Resolved
PRIOR TO JACKING UP AT THE NEXT DRILLING LOCATION, RETURN THE FOUR D/L L/R'S TO THEIR PROPER STATIONS FROM THEIR TEMP VOYAGE STORAGE LOCATION. TWO25-MAN THROW OVER L/R'S TO BE MOUNTED IN A FLOAT-FREE ARRANGEMENT PRIOR TO DEP SINGAPORE. VSL LIMITED TO 50 PERS UNTIL D/L L/R'S RET TO PROP STATIONS.
Condition: Unknown
Due 13 March 1990
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 7 November 1989
Resolved
PROVIDE U.L. OR F.M. DOCUMENTATION OF APPROVAL FOR FORKLIFT.
Condition: Unknown
Due 7 November 1989
Resolved 7 November 1989
Construction/Loadline
Issued 8 September 1989
Resolved
INSTALL A HAND RELIEVING TYPE RELIEF VALVE ON THE RIG FLOOR AIR RECEIVER. SET AND TEST THE VALVE TO RELIEVE AT OR BELOW THE MAWP OF 135 PSI.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Accommodation/Occupational Safety
Issued 8 September 1989
Resolved
INSTALL NEW HATCH ON SCR ROOM ESCAPE TRUNK.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Documentation
Issued 8 September 1989
Resolved
PROVIDE EVIDENCE OF ANNUAL CRANE INSPECTION.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Fire Fighting
Issued 8 September 1989
Resolved
INSTALL AND DEMONSTRATE IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR, THE MAIN FIRE PUMP.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Fire Fighting
Issued 8 September 1989
Resolved
PROVIDE EVIDENCE THAT FIXED AND PORTABLE FIRE EXTINGUISHING SYSTEMS HAVE BEEN INSPECTED AND SERVICED INCLUDING ANALYSIS OF STORED FOAM.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Unknown
Issued 9 September 1988
Resolved
CONDUCT FIRE AND BOAT DRILLS PRIOR TO DEPARTING SINGAPORE.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Electrical
Issued 9 September 1988
Resolved
PROVIDE SUITABLE LINING FOR BOXES CONTAINING LEAD ACID BATTERIES ABOVE CONTROL ROOM.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Construction/Loadline
Issued 9 September 1988
Resolved
DISMANTLE AND CLEAN STARBOARD SEA CHEST VALVES FOR INSPECTION.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Unknown
Issued 9 September 1988
Resolved
RENEW OR REPLACE 12" MASTER MUD PIT DUMP VALVE.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Fire Fighting
Issued 9 September 1988
Resolved
REPAIR AND DEMONSTRATE PROPER OPERATION OF RELIEF VALVE FOR FIRE PUMP LOCATED IN THE MUD PUMP ROOM.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Accommodation/Occupational Safety
Issued 9 September 1988
Resolved
INSTALL NEW GASKETS IN VENT COVERS LOCATED AT FORWARD MAIN DECK ACCOMMODATION SPACE ENTERING BULKHEAD.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Construction/Loadline
Issued 9 September 1988
Resolved
COMPLETE DDX INSPECTION BY MAKING SPUD CANS, PRELOAD DUMP VALVES AND CRITICAL CONNECTIONS AVAILABLE FOR INSPECTION BY A USCG MARINE INSPECTOR.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Fire Fighting
Issued 9 September 1988
Resolved
SUBMIT DRAWINGS OF FIXED FOAM SYSTEMS TO USCG MARINE SAFETY CENTER FOR APPROVAL.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Unknown
Issued 9 September 1988
Resolved
SUBMIT DRAWINGS OF HELICOPTER FUEL TRANSFER EQUIPMENT AND STORAGE FACILITIES TO USCG MARINE SAFETY CENTER FOR APPROVAL.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Deck/Cargo
Issued 9 September 1988
Resolved
PROVIDE EVIDENCE OF ANNUAL CARGO GEAR INSPECTION.
Condition: Unknown
Due 9 September 1988
Resolved 9 September 1988
Unknown
Issued 12 November 1986
Resolved
LIFEBOATS NUMBER 1 AND NUMBER 2 ARE TO BE LOWERED TO THE WATER, RELEASED, AND OPERATED IN THE PRESENCE OF A U. S. COAST GUARD INSPECTOR.
Condition: Unknown
Due 12 November 1986
Resolved 12 November 1986
Unknown
Issued 12 November 1986
Resolved
SERVICE THE VESSEL'S PORTABLE, SEMI-PORTABLE AND FIXED FIRE EXTINGUISHING EQUIPMENT. THE LINES FOR THE FIXED CO2 SYSTEM ARE TO BE BLOWN THROUGH AND RELATED PULL CABLES, ALARMS AND VENTILATION SHUTDOWNS ARE TO BE TESTED.
Condition: Unknown
Due 12 November 1986
Resolved 12 November 1986
Lifesaving
Issued 5 February 1986
Resolved
LOCATE AND INSTALL LIFERING BOUY, LIGHT AND SMOKE SIGNAL IN VICINITY OF PORT SIDE LIFEBOAT.
Condition: Unknown
Due 5 February 1986
Resolved 5 February 1986
Lifesaving
Issued 5 February 1986
Resolved
PROVE 58 PERSON WATERCRAFT LIFEBOAT INSTALLATION AND WEIGHT TEST AT 110 PERCENT DURING NEXT JACKED LOCATION.
Condition: Unknown
Due 5 February 1986
Resolved 5 February 1986
Unknown
Issued 5 February 1986
Resolved
LIFESAVING FIRE CONTROL PLAN K 3590007 #1-4 SHALL BE CORRECTED SHOWING NEW QUARTERS MODIFICATIONS AND LIFESAVING EQUIPMENT CHANGES. SUBMIT FOR U. S. COAST GUARD APPROVAL.
Condition: Unknown
Due 5 February 1986
Resolved 5 February 1986
Unknown
Issued 5 February 1986
Resolved
MAKE PERMANENT REPAIRS TO THE FORWARD #1 CAN "K" BRACE TO CAN INTERIOR SUPPORTING "H" BEAM STANCHIONS W12X31, PORT, STARBOARD AND AFT. SEE LEG TO CAN STRUCTURE DWG L-861-110-1. REPAIRS SHALL BE MADE DURING NEXT RIG MOVE.
Condition: Unknown
Due 5 February 1986
Resolved 5 February 1986
Lifesaving
Issued 5 February 1986
Resolved
STARBOARD #3 INFLATABLE LIFERAFT CONTAINER IS DAMAGED AND SHALL BE REPAIREDOR RENEWED.
Condition: Unknown
Due 5 February 1986
Resolved 5 February 1986
Unknown
Issued 27 November 1985
Resolved
RECHARGE THE EMPTY AIR BOTTLE IN THE PORT MOTOR LIFEBOAT.
Condition: Unknown
Due 27 November 1985
Resolved 27 November 1985
Unknown
Issued 27 November 1985
Resolved
RELOCATE ALL FOUR INFLATABLE LIFERAFTS TO THE POSITIONS INDICATED ON THE RIGS FIRE AND SAFETY PLAN. THIS REQUIREMENT DOES NOT CHANGE THE REQUIRE- MENT TO INSTALL DAVIT LAUNCHED LIFERAFTS PREVIOUSLY ISSUED.
Condition: Unknown
Due 27 November 1985
Resolved 27 November 1985
Unknown
Issued 5 September 1985
Resolved
REMOVE PRESENT HYDROSTATIC RELEASE DEVICES ON ALL FOUR 25 MAN LIFERAFTS, REPLACE WITH SAME THAT HAVE BEEN TESTED WITHIN LAST 12 MONTHS.
Condition: Unknown
Due 5 September 1985
Resolved 5 September 1985
Unknown
Issued 5 September 1985
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 September 1985
Resolved 5 September 1985
Unknown
Issued 5 September 1985
Resolved
REPLACE ALL EXISTING THROWOVER INFLATABLE LIFERAFTS WITH DAVIT LAUNCHED LIFERAFTS. PLANS SHALL BE SUBMITTED FOR APPROVAL PRIOR TO INSTALLATION.
Condition: Unknown
Due 5 September 1985
Resolved 5 September 1985
Unknown
Issued 5 September 1985
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 5 September 1985
Resolved 5 September 1985
Unknown
Issued 5 September 1985
Resolved
REPAIR OR REPLACE O/S TRIP ON #1 SERVICE GENERATOR AND SHOW PROPER OPERATION TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 5 September 1985
Resolved 5 September 1985
Unknown
Issued 5 September 1985
Resolved
REPAIR OR REPLACE LOW L/O SHUTDOWN ON #3 SERVICE GENERATOR AND SHOW PROPER OPERATION TO ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 5 September 1985
Resolved 5 September 1985
Unknown
Issued 5 September 1985
Resolved
SUBMIT A REVISED FIRE CONTROL PLAN FOR APPROVAL.
Condition: Unknown
Due 5 September 1985
Resolved 5 September 1985
Unknown
Issued 5 September 1985
Resolved
RECHARGE AIR BOTTLE IN STARBOARD LIFEBOAT.
Condition: Unknown
Due 5 September 1985
Resolved 5 September 1985
Unknown
Issued 5 September 1985
Resolved
SERVICE ALL FOUR THROWOVER INFLATABLE LIFERAFTS AT A COAST GUARD APPROVED SERVICING FACILITY.
Condition: Unknown
Due 5 September 1985
Resolved 5 September 1985