Records from 1981 to 2024. Most recent: inspection, 18 January 2024.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 56
18 January 2024
Uninspected Passenger Vessel
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7852552
12 August 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6780831
17 May 2019
Explosive Handling Operation-Commercial
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6686692
10 January 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6603474
21 June 2016
Internal Structural Exam · Administrative Inspection · Drydock Exam · COI Inspection · Examination of Repairs · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5908483
10 November 2015
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5761514
16 August 2015
Type not recorded
No type recorded · Station Venice · USCG Heartland District (CGD-H) · Activity 5217677
20 October 2014
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5008571
16 May 2014
Annual Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4856450
22 May 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4312083
30 March 2009
Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3439689
17 June 2008
Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3232533
14 June 2007
Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2961764
23 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2938156
23 May 2007
Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2938436
10 May 2007
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2927074
26 April 2007
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2915980
19 March 2007
Type not recorded
No type recorded · Station Grand Isle · USCG Heartland District (CGD-H) · Activity 2891377
19 March 2007
In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2897359
13 July 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2711335
1 July 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2711264
17 February 2006
COI Inspection · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2587248
18 October 2000
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1057230
9 September 1999
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1386597
27 October 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457606
16 October 1997
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409766
5 December 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 190242
5 December 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 770820
7 November 1996
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 875215
7 November 1996
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1355999
20 August 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 190241
20 August 1996
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 760574
7 November 1995
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1398348
28 October 1993
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1152364
30 October 1992
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1463744
30 October 1991
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1312699
30 October 1990
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 901299
10 April 1990
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1216806
21 December 1989
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 931336
14 December 1989
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1212246
3 November 1988
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 892259
1 December 1987
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1027597
10 December 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1025013
14 October 1986
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1024319
9 April 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 999160
10 December 1985
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 992002
26 July 1985
Examination of Repairs · Damage Survey
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 982192
24 July 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 977808
7 June 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983028
28 March 1985
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 981893
11 December 1984
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1284540
6 December 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 971239
17 October 1983
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 963565
9 December 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 969839
9 August 1982
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 968363
10 December 1981
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 967135
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 10 January 2019
Resolved
The two QAWTD's located between the e/r and the workshop, and bewteen the workshop and the crew accomodations when inspected the gaskets did not properly seal. Replace gaskets and prove doors are water tight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 January 2019
Resolved 15 January 2019
Resolution: Both QAWTD gaskets noted were replaced and chalk tested. Doors were proven to be watertight. Inspected satisfactory.
Stability › Watertight Integrity › General
Issued 26 June 2014
Resolved
Replace watertight door gaskets on Engine Room doors prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2014
Stability › Watertight Integrity › General
Issued 26 June 2014
Resolved
Adjust two (2) quick-acting watertight doors prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2014
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 26 June 2014
Resolved
Provide blank for Engine Room distribution panel prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 June 2014
Electrical › Electrical Distribution System (service) › Switchboard
Issued 26 June 2014
Resolved
Make operable main switchboard ground fault indicator.
Action required: 705 - Other - as specified
Due 26 July 2014
Resolved 7 August 2014
Resolution: Attended vessel M/I observed and accepted satisfactory repairs to vessels main ground detection indicator.
Stability › Watertight Integrity › General
Issued 26 June 2014
Resolved
Make welding repairs to Engine Room overhead plating by cap welding to areas marked.
Action required: 705 - Other - as specified
Due 26 July 2014
Resolved 7 August 2014
Resolution: Attended vessel M/I observed and accepted satisfactory repairs to overhead.
Stability › Watertight Integrity › General
Issued 16 May 2014
Resolved
Cap vent hole STND Engine Room emergency escape prior to sailing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2014
Communications › Alarms/Indicators › Bilge Alarm
Issued 17 June 2008
Resolved
The bilge alarm system was not properly working. Show proper operation of the vessels bilge alarm system to attending MI
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2008
Communications › Alarms/Indicators › General Alarm
Issued 17 June 2008
Resolved
There is no way for the General Alarm to be heard or seen in the Machinery Space. Provide way for proper operation of the general alarm system availability in the machinery space to the satisfaction of the attending MI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2008
Construction/Loadline › Hull › Hull Plating
Issued 17 June 2008
Resolved
Frwd STBD scupper walls are completely wasted away. Crop and renew wasted metal on the STBD forward scupper
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2008
Engineering › Bilge Water Management System › Valve
Issued 17 June 2008
Resolved
During operational test of remote bilge valve the reach rod broke at the base. Make proper repair the reach rod on the forepeak bilge system
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2008
Lifesaving › Lifefloat › Lifeline
Issued 17 June 2008
Resolved
There are metal twist ties on the Life float lifelines. Replace the twist ties on the life float lifeline with breakaway ties
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 June 2008
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 14 June 2007
Resolved
The navigation rules book was missing.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2007
Operations/Management › Drills/Instruction › Fire
Issued 14 June 2007
Resolved
All quarterly drills were not being logged properly.
Action required: 705 - Other - as specified
Resolved 17 June 2008
Lifesaving › Lifefloat › Lifeline
Issued 14 June 2007
Resolved
The lifefloats were not tethered together.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2007
Communications › Alarms/Indicators › Bilge Alarm
Issued 14 June 2007
Resolved
The bilge alarm system did not function properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 June 2007
Resolution: Valure Offshore & Marine, Inc made repairs
Stability › Weathertight Integrity › General
Issued 14 June 2007
Resolved
Several windows in the pilot house has leaking gaskets.
Due 30 June 2007
Resolved 14 June 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 14 June 2007
Resolved
An updated light list was not onboard.
Due 30 June 2007
Resolved 29 June 2007
Communications › Public Address System › Broadcast Location
Issued 14 June 2007
Resolved
An emergency broadcast placard was not onboard.
Due 30 June 2007
Resolved 14 June 2007
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 14 June 2007
Resolved
The emergency instructions were not posted in the pilot house.
Due 30 June 2007
Resolved 14 June 2007
Engineering › Steam System (auxiliary) › Lagging/Insulation
Issued 14 June 2007
Resolved
Exhaust lagging was missing on part of the port engine exhaust.
Due 30 June 2007
Resolved 18 June 2007
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 June 2007
Resolved
The A/C unit installed above the pilot house was not properly secured.
Due 30 June 2007
Resolved 29 June 2007
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 March 2007
Resolved
Replace 2 electrical junction box under bridge station
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Junction boxes were in place.
Communications › Alarms/Indicators › Fire Alarm
Issued 19 March 2007
Resolved
Renew batteries in all smoke alarms
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: All smoke alarms operate correctly.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 March 2007
Resolved
Renew stbd outboard lifefloat light
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Lifefloat light in place and working.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 March 2007
Resolved
Properly mount life ring line on bridge wing
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Life ring line mounted correctly.
Lifesaving › Lifefloat › Paddle
Issued 19 March 2007
Resolved
Lash down 2 paddles to each lifefloat.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Paddles properly attached to lifefloat
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 19 March 2007
Resolved
Remark each lifering with vessel name and port
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Life rings correctly marked with name and port.
Lifesaving › Lifefloat › Float Free
Issued 19 March 2007
Resolved
Properly lash lifefloats to painter attached to vessel
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Painter attached correctly to lifefloat.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 19 March 2007
Resolved
Remove paint overspray from mast navigation lights.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: All nav lights completely renewed.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 March 2007
Resolved
Replace chair on aft bridge inspection
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Chair replaced with operating chair.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 19 March 2007
Resolved
Remark all emergency exits
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Emergency exits were marked.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 19 March 2007
Resolved
Reservice all portable fire extinguishers on board (exp Nov 2006)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Fire extinguishers inspected by contractor for annual service.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 19 March 2007
Resolved
Renew emergency lighting in accomidation areas
46 CFR 184.30-5
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Emergency lighting is operational in accomodation areas.
Stability › Watertight Integrity › General
Issued 19 March 2007
Resolved
Renew watertight door gasket & adjust all doors in engine space
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2007
Resolution: New gaskets installed in watertight doors.
Electrical › Lighting (service) › Switch
Issued 19 March 2007
Resolved
Cover open light switch box in engineer's cabin
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Exposed light switch was covered correctly.
Stability › Watertight Integrity › General
Issued 19 March 2007
Resolved
Reseal engine room watertight bulkhead cable and other penetrations
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: New stuffing tubes were mounted on bulkhead to make pentrations watertight.
Accommodation/Occupational Safety › Other Accommodation Spaces › Laundry
Issued 19 March 2007
Resolved
Rig dryer vent hose to remove lint from E/R & clean lint from behind dryer.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Dryer lint catch was added to hose. Lint cleaned out from behind dryer.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 March 2007
Resolved
Replace light guard over washer/dryer
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Light guard was replaced on light fixture.
Electrical › Electric Generation Source (service) › Switch
Issued 19 March 2007
Resolved
Remount generator switch box
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Generator switch box remounted.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 19 March 2007
Resolved
Place rubber mat in front of electrical switch board
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Rubber mat was installed near switchboard.
Electrical › Electric Supply System (service) › Battery Installation
Issued 19 March 2007
Resolved
Place port battery in covered battery box
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Battery was placed in battery box.
Stability › Watertight Integrity › General
Issued 19 March 2007
Resolved
Place valve on A/C line WTB penetration piping in engine room so flow can be closed from both sides of the bulkhead
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Valve was installed in A/C line forward of bulkhead.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 19 March 2007
Resolved
Replace missing blanks in E/R electrical breaker box
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Blanks installed in breaker box.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 19 March 2007
Resolved
Remove bucket of oil from under port generator and dispose of properly
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Bucket was removed.
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 19 March 2007
Resolved
Clean generator armatures
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Generators were cleaned by contracted electricians.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 March 2007
Resolved
Remove or repair dead wiring from stbd engine .
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Wires were removed or reconnected.
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 19 March 2007
Resolved
Remove paint cans and spare battery from engine room deck and stow properly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Flammables removed from engine room.
Electrical › Electrical Distribution System (service) › Switch
Issued 19 March 2007
Resolved
Replace cover on stbd air compressor switch
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2007
Resolution: Cover was replaced on switch for compressor.
Engineering › Bilge Water Management System › Pump
Issued 19 March 2007
Resolved
Remount electrical wiring on ballast pump
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Wiring for ballast pump rewired.
Engineering › Diesel Engine (propulsion-reduction gear) › Injector (fuel injection)
Issued 19 March 2007
Resolved
Repair oil leak on port engine
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Oil leaks repaired on engines.
Engineering › Fuel Oil Service System › Piping
Issued 19 March 2007
Resolved
Repair fuel system leaks at elbows in piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Fuel leaks repaired in piping.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 March 2007
Resolved
Renew light cover over port engine
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Light cover replaced on lights.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 19 March 2007
Resolved
Mount cover over electrical junction box inside stack house
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Junction box covered with cover.
Fire Fighting › Remote Fuel Shutoff › General
Issued 19 March 2007
Resolved
Remark location of emergency fuel shutoffs
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Fuel shutdowns marked at shutdowns.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 19 March 2007
Resolved
Renew vent/ventcovers on both stacks
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Vent covers renewed on stacks.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 19 March 2007
Resolved
Remove gear from port stack house ladder area
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Geared stowed in stack house was removed.
Electrical › Lighting (service) › Lighting Fixture
Issued 19 March 2007
Resolved
Renew light cover for light in port stack house
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Light cover in stackhouse renewed.
Fire Fighting › Nozzles › Condition
Issued 19 March 2007
Resolved
Renew proper fire nozzles in working condition for marine inspector and demonstrate proper use.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: New hoses were installed and proper operation of nozzles displayed.
Stability › Unintentional Flooding › General
Issued 19 March 2007
Resolved
preoceed directly to dry-dock to make approved repairs to wasted rudder posts & mounts. Remove both rudders & make available for inspection by USCG marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Rudder tubes were completely renewed and reinstalled.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 19 March 2007
Resolved
Vessel is operating under the COI without a licenced master in charge of the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 May 2007
Resolution: Qualified master is onboard and operating vessel.
Lifesaving
Issued 9 September 1999
Resolved
DEMONSTRATE COMPLIANCE WITH CCGD8 POLICY FOR RESCUE BOAT REQUIREMENTS FOR OFFSHORE SUPPLY VESSELS DATED 12 NOV 98 TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 9 October 1999
Resolved 17 September 1999
Construction/Loadline
Issued 30 October 1991
Resolved
REMOVE OR PROVE PROPER OPERATION OF E/R BILGE ALARM.
Condition: Unknown
Due 30 November 1991
Resolved 6 November 1991
Electrical
Issued 30 October 1991
Resolved
PROVIDE COVER FOR EXPOSED FLUORESCENT LIGHT IN LOWER BERTHING COMPARTMENT.
Condition: Unknown
Due 30 November 1991
Resolved 6 November 1991
Lifesaving
Issued 30 October 1991
Resolved
STENCIL "EMERGENCY ESCAPE KEEP CLEAR" WARNING ON DECK ABOVE E/R EMERG ESCAPE HATCH AND IN E/R BELOW HATCH.
Condition: Unknown
Due 30 November 1991
Resolved 6 November 1991
Lifesaving
Issued 30 October 1990
Resolved
REPAIR OR REPLACE SSB RADIO.
Condition: Unknown
Due 30 October 1990
Resolved 30 October 1990
Navigation
Issued 14 December 1989
Resolved
REPAIR STERN NAVIGATIONAL LIGHT.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Deck/Cargo
Issued 14 December 1989
Resolved
RENEW FLAME SCREENS ON SEWAGE TANK AND BOW TANK BEFORE TAKING ON FUEL.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Documentation
Issued 14 December 1989
Resolved
PROVIDE EVIDENCE OF CURRENT DOCUMENT.
Condition: Unknown
Due 14 December 1989
Resolved 14 December 1989
Documentation
Issued 1 December 1987
Resolved
PROVIDE EVIDENCE OF CURRENT CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 1 December 1987
Resolved 1 December 1987
Electrical
Issued 11 December 1984
Resolved
REPLACE THE BATTERY BOX WITH A SUITABLE LINED BOX.
Condition: Unknown
Due 11 December 1984
Resolved 11 December 1984
Unknown
Issued 17 October 1983
Resolved
THE FOLLOWING DEFICIENCIES ARE FOR THE SALLIE MCCALL, DN629684.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Unknown
Issued 17 October 1983
Resolved
REMOVE THE BILGE DRAIN PIPE VALVE AND WELD THIS PIPING SHUT IN BOTH COMPARTMENTS.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Unknown
Issued 17 October 1983
Resolved
MAKE ALL OF THE BULKHEAD PENETRATIONS WATERTIGHT.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983
Unknown
Issued 17 October 1983
Resolved
VENTILATE THE RUDDER COMPARTMENT TO THE ATMOSPHERE.
Condition: Unknown
Due 17 October 1983
Resolved 17 October 1983