MAURY USCG vessel records Sign in
← All vessels

ABILITY

ABILITY is a 1981 passenger vessel (uninspected). The Coast Guard has recorded 28 inspections since 1986, most recently in June 2001, along with 51 deficiencies.

Records from 1986 to 2001. Most recent: inspection, 21 June 2001.

Built
1981
Last inspected
21 June 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

Flag
UNITED STATES
—
Maury page id
psix-53114

Inspections, by type

…with no type recorded1
Years with a record 16 calendar years (1986–2001)
The 28 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it4 - Regulatory (Subpart C or D), Net Ton
7 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 28

21 June 2001 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1067337
25 January 2000 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1432279
5 March 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 792200
22 January 1999 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1411802
2 March 1998 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1414944
3 April 1997 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1383484
4 March 1997 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1468403
8 March 1996 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1357497
4 May 1995 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 871233
23 March 1995 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 825637
10 March 1995 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1448623
24 March 1994 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 853218
4 February 1994 Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 852309
30 April 1993 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1141446
29 July 1992 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 961709
21 August 1991 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 942373
9 May 1991 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1235193
31 August 1990 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1232949
2 August 1990 COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 917368
22 September 1989 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 898947
8 September 1989 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 896445
24 August 1989 Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1032843
5 July 1989 Drydock Extension
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1210140
29 August 1988 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1039066
9 August 1988 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1037764
27 August 1987 Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1031486
9 September 1986 Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1309850
10 March 1986 Credit Drydock · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 985279

Deficiency record · 51

Navigation
Issued 25 January 2000 Resolved
Secure the pin connecting the hydraulic ram to the rudder.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Navigation
Issued 25 January 2000 Resolved
Provide updated light list.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Lifesaving
Issued 25 January 2000 Resolved
Attatch an 18 foot lanyard to the waterlight on buoyant apparatus.
Condition: Unknown
Due 7 March 2000
Resolved 7 March 2000
Documentation
Issued 3 April 1997 Resolved
Provide a Certificate of Documentation for the vessel or provide evidence that vessel is less than 5 net tons. (Admeasurement must be performed by ABS or DNV).
Condition: Unknown
Due 7 May 1997
Resolved 4 April 1997
Accommodation/Occupational Safety
Issued 8 March 1996 Resolved
Replace cracked window in pilothouse on starboard side.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Electrical
Issued 10 March 1995 Resolved
REPLACE WINGNUTS WITH HEX NUTS ON BATTERY.
Condition: Unknown
Due 10 March 1995
Resolved 10 March 1995
Electrical
Issued 10 March 1995 Resolved
PROVIDE PROPER GROUND FOR FUEL FILL PIPE.
Condition: Unknown
Due 10 March 1995
Resolved 10 March 1995
Fire Fighting
Issued 10 March 1995 Resolved
REPLACE WASTED AFT BRACKET FOR PORTABLE FIRE EXTINGUISHER.
Condition: Unknown
Due 10 March 1995
Resolved 10 March 1995
Construction/Loadline
Issued 10 March 1995 Resolved
PROVIDE POSITIVE SHUT OFF VALVES FOR EACH DISCHARGE LINE FROM RULE PUMPS.
Condition: Unknown
Due 10 March 1995
Resolved 10 March 1995
Unknown
Issued 24 March 1994 Resolved
PROVE SUFFICIENT RANDOM DRUG TEST PROGRAM; THIS ITEM TO BE COMPLETED PRIOR TO RE-ISSUE OF COI.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Lifesaving
Issued 24 March 1994 Resolved
ATTACH WATER LIGHT TO LIFE FLOAT WITH A LINE OF SUITABLE LENGTH; THIS ITEM TO BE COMPLETED PRIOR TO RE-ISSUE OF COI.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Navigation
Issued 24 March 1994 Resolved
PROVE PROPER OPERATION OF EMERGENCY STEERING; THIS ITEM TO BE COMPLETED PRIOR TO RE-ISSUE OF COI.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Electrical
Issued 24 March 1994 Resolved
PROVIDE A SUITABLE COVER FOR BATTERY BOX.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Construction/Loadline
Issued 24 March 1994 Resolved
SECURE "RULE" BILGE PUMP IN ENGINE COMPARTMENT BILGE.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Engineering
Issued 24 March 1994 Resolved
PROVIDE FLAME SHIELD FOR "RAYCOR" FUEL STRAINER.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Lifesaving
Issued 24 March 1994 Resolved
REPLACE OR REPAIR LIFE FLOAT TO MANUFACTURER'S SPECS; TO BE COMPLETED PRIORTO RE-ISSUE OF COI.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Navigation
Issued 24 March 1994 Resolved
PROVIDE ONBOARD CURRENT EDITION OF TIDE TABLES.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Electrical
Issued 24 March 1994 Resolved
TERMINATE OR REMOVE DEAD-END WIRE IN OVERHEAD BEHIND STEERING STAND.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Electrical
Issued 24 March 1994 Resolved
REMOVE DEFUNCT WIRING BUNDLE ON STARBOARD SIDE RUNNING FROM OPERATOR'S STAND TO ENGINE COMPARTMENT.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Electrical
Issued 24 March 1994 Resolved
RELABEL ALL ELECTRICAL BREAKERS.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Electrical
Issued 24 March 1994 Resolved
PROVIDE COVER FOR LIGHT FIXTURE IN PFD STORAGE LOCKER.
Condition: Unknown
Due 24 March 1994
Resolved 24 March 1994
Navigation
Issued 24 March 1994 Resolved
PROVIDE ONBOARD CURRENTLY CORRECTED CHARTS.
Condition: Unknown
Due 8 July 1994
Resolved 8 July 1994
Engineering
Issued 30 April 1993 Resolved
MAKE AVAILIABLE FOR INSPECTION THE MAIN DIESEL ENGINE, AFTER INSTALLATION._x001C_THIS ITEM IS TO BE COMPLETED PRIOR TO THE CARRIAGE OF PASSENGERS FOR HIRE.
Condition: Unknown
Due 30 April 1993
Resolved 30 April 1993
Lifesaving
Issued 21 August 1991 Resolved
PROVIDE ON BOARD SIX CURRENT ORANGE SMOKE FLARES PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 21 August 1991
Resolved 21 August 1991
Lifesaving
Issued 21 August 1991 Resolved
PROVIDE ONE ADDITIONAL CHILD SIZE LIFE PRESERVER. VESSEL LIMITED TO CARRYING 3 PERSONS WEIGHING LESS THAN 90 POUNDS.
Condition: Unknown
Due 21 August 1991
Resolved 21 August 1991
Electrical
Issued 21 August 1991 Resolved
PROVIDE GUARD FOR OVERHEAD LIGHT IN CABIN.
Condition: Unknown
Due 21 August 1991
Resolved 21 August 1991
Lifesaving
Issued 21 August 1991 Resolved
INSTALL A WEAK LINK OF PRPOER BREAKING STRENGTH FOR THE 25 PERSON LIFE FLOAT PRIOR TO GETTING THE VESSEL UNDERWAY.
Condition: Unknown
Due 21 August 1991
Resolved 21 August 1991
Lifesaving
Issued 21 August 1991 Resolved
PROPERLY INSTALL WATERLIGHT FOR LIFE FLOAT PRIOR TO GETTING VESSEL UNDERWAY.
Condition: Unknown
Due 21 August 1991
Resolved 21 August 1991
Engineering
Issued 2 August 1990 Resolved
REPAIR OR REPLACE VESSEL'S MAIN ENGINE TACHOMETER.
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Documentation
Issued 2 August 1990 Resolved
PROVIDE ON BOARD A VALID RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Fire Fighting
Issued 2 August 1990 Resolved
SERVICE VESSEL'S DRY CHEMICAL FIRE EXTINGUISHERS.
Condition: Unknown
Due 2 August 1990
Resolved 2 August 1990
Lifesaving
Issued 8 September 1989 Resolved
REPAIR TWO HOLED AREAS ON BUOYANT APPARATUS.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Lifesaving
Issued 8 September 1989 Resolved
REPLACE GRAB LINE ON RING LIFE BUOY.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Lifesaving
Issued 8 September 1989 Resolved
REPAIR OR REPLACE ONE ADULT PFD. VESSEL IS LIMITED TO 34 TOTAL PERSONS ALLOWED.
Condition: Unknown
Due 8 September 1989
Resolved 8 September 1989
Construction/Loadline
Issued 24 August 1989 Resolved
PERMANENTLY PLUG HOLES IN TRANSOM FROM OLD EXHAUST SYSTEM.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Construction/Loadline
Issued 24 August 1989 Resolved
PROPERLY REPAIR HOLES IN TRANSOM BELOW RUB RAIL.
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Construction/Loadline
Issued 24 August 1989 Resolved
MAKE AFT HATCH TO ENGINE SPACE WATERTIGHT IAW 46 CFR 171.124(A).
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Engineering
Issued 24 August 1989 Resolved
MAKE EXHAUST PIPE PENETRATIONS IN TRANSOM WATERTIGHT IAW 46 CFR 182.15-20(D).
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Engineering
Issued 24 August 1989 Resolved
PROVIDE MEANS OF PREVENTING ENTRY OF COLD WATER INTO ENGINE EXHAUST IAW 46 CFR 182.15-15(A)(2).
Condition: Unknown
Due 24 August 1989
Resolved 24 August 1989
Navigation
Issued 9 August 1988 Resolved
PROVE PROPER OPERATION OF PORT RUNNING LIGHT.
Condition: Unknown
Due 9 August 1988
Resolved 9 August 1988
Lifesaving
Issued 9 August 1988 Resolved
REPLACE MISSING PENDANTS AND MAKE REPAIRS TO NET SUPPORT STRAPS AND VARIOUSHOLES ON BUOYANT APPARATUS.
Condition: Unknown
Due 9 August 1988
Resolved 9 August 1988
Fire Fighting
Issued 9 August 1988 Resolved
SERVICE ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 9 August 1988
Resolved 9 August 1988
Navigation
Issued 9 August 1988 Resolved
PROVE PROPER OPERATION OF HORN.
Condition: Unknown
Due 9 August 1988
Resolved 9 August 1988
Lifesaving
Issued 9 August 1988 Resolved
PROVIDE SIX APPROVED RED FLARES.
Condition: Unknown
Due 9 August 1988
Resolved 9 August 1988
Construction/Loadline
Issued 27 August 1987 Resolved
LOCATION WHERE EXHAUST PIPES LEAVE THROUGH HULL AT TRANSOM NEED RESEALING.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Construction/Loadline
Issued 27 August 1987 Resolved
RUB RAIL SUPPORTS NEED TO BE REMOVED/REPLACED WHERE WELDS HAVE CRACKED AND/OR BROKEN ON PORT & STBD QUARTERS.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Construction/Loadline
Issued 27 August 1987 Resolved
STERN DECK WALK RAIL VOIDS NEED TO BE CLEANED OF WATER & MADE WATERTIGHT.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Electrical
Issued 27 August 1987 Resolved
ENGINE COMPARTMENT BILGE PUMP NEEDS TO BE REPLACED OR REPAIRED DUE TO MALFUNCTION.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Electrical
Issued 27 August 1987 Resolved
DECK FLOODLIGHTS NEED TO BE REPLACED/REPAIRED DUE TO MALFUNCTION.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Electrical
Issued 27 August 1987 Resolved
PUBLIC ADDRESS SYSTEM NEEDS TO BE REPAIRED/REPLACED SO THAT HORN WILL WORK.PA SYSTEM INOPERATIVE.
Condition: Unknown
Due 27 August 1987
Resolved 27 August 1987
Navigation
Issued 9 September 1986 Resolved
REPLACE CRACKED WINDOW STBD. SIDE WHEEL HOUSE.
Condition: Unknown
Due 9 September 1986
Resolved 9 September 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.